• Title/Summary/Keyword: Internal standard kit

Search Result 15, Processing Time 0.024 seconds

A Study on the Quality Control of 2-site Immunoradiometric Assay of Serum Ferritin (혈청(血淸) ferritin 측정(測定)의 정도관리(精度管理)에 관(關)한 고찰(考察))

  • Kim, Byoung-Kook;Seo, Il-Tack;Kim, Kwang-Won;Cho, Bo-Yeon;Koh, Chang-Soon;Lee, Mun-Ho
    • The Korean Journal of Nuclear Medicine
    • /
    • v.14 no.1
    • /
    • pp.9-16
    • /
    • 1980
  • A 2-site immunoradiometric assay for serum ferritin was evaluated with commercially available kit. The assay required 6 hours. The slope of the standard curve kept up ideal range with the calculation of maxium binding instead of total dose until expire date. The stage II washing was more important than the stage I washing on the modified washing procedure as the bead keeping to remain in the tube. With this modified mothod, three times of tube. washing was sufficient to reduce the significant errors The measured values of serially diluted sample with standard diluting buffer was proportional to the predicted values. In the experiment of serum effect on the assay. a linear relationship from 5 to 50% serum, but beyond 50% there was reduction in measured ferritin concentration. It has a sensitivity of 2.77 ng/ml, within-assay precision (CV) of 8.0%, and between-assay reproducibility(CV) of 7.4% (mean 174.8 ng/ml).

  • PDF

Use of Real-Time PCR and Internal Standard Addition Method for Identifying Mixed Ratio of Chicken Meat in Sausages (Real-Time PCR과 Internal Standard Addition법을 이용한 돼지고기 소시지에 혼합된 닭고기의 정량)

  • Lee, Namrye;Joo, Jae-Young;Yeo, Yong-Heon
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.46 no.9
    • /
    • pp.1097-1105
    • /
    • 2017
  • This study examined how much chicken meat was in sausage made with pork. Both real-time polymerase chain reaction (PCR) and internal standard addition were used. Fifty ng of chicken DNA was added to the sausages as an internal standard. The addition of standard DNA increased the amplification efficiency of PCR and confirmed the possibility of quantitative analysis. A QIAamp DNA Micro Kit was used to improve the DNA recovery and amplification efficiency. The density of template DNA and primer were suitable for $3.0{\sim}5.0{\mu}L$ and $0.5{\mu}L$, respectively. Each DNA of pig and chicken was diluted in 10-fold from steps 50 ng to 0.05 ng. The detection limit of both pig and chicken meat was more than 0.05 ng and the correlation coefficient of the standard curve was at least 0.98. The result of the quantitative analysis after heat treatment of 3 samples of pigs and chickens mixed at 70:30 showed a 5.7% difference (64.3:35.7) between the expected value and measured value. The quantitative value was changed by affecting the DNA according to the heat treatment ($70^{\circ}C$, 10 min). An analysis of the pork and chicken content in sausages showed that it was difficult to detect chicken meat and the quantitative value of DNA according to the Ct value was very low. On the other hand, when adding standard material (50 ng of chicken DNA) to the sausages, the Ct value decreased gradually with increasing chicken mixing ratio. Thus, the mixing ratio of chicken in sausages could be estimated.

Radioimmunoassay Using Quality Control Materials BIO-RAD of the Suggestions for Setting Acceptable Range (BIO-RAD 정도관리 물질을 이용한 방사면역측정법의 Acceptable Range 설정에 대한 제언)

  • Park, Hee-Won;Kim, Tae-Hoon;Roh, Gyeong-Un;Kim, Hyun-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.108-114
    • /
    • 2012
  • Purpose: Immunosorbent assay most commonly used in the laboratory and commercial third-party quality control material is a substance that provided by BIO-RAD. However, in Reference Sheet by radioimmunoassay test kit or a measuring device for the mention of Acceptable Range is somewhat lacking. Radioimmunoassay for the inspection of test results by setting Acceptable Range to increase the objectivity of the recommendations on the data accumulated by the manufacturer listed in the Reference Sheet is to be issued. Materials and Methods : In our hospital since 2009 partially BIO-RAD using quality control materials in 2011, excluding certain items, some items were most of the BIO-RAD third-party quality control materials are used. Thus, internal quality control data accumulated BIO-RAD's Unity Real Time program by using the items were measured. Results : BIO-RAD using quality control material items were about 50 of the 20 Point Data averages, standard deviations, variation coefficients were calculated to measure the Acceptable Range of kit, automated immunoassay attributed Roche Elecsys / E170 / cobas e Systems the measures and compared. Conclusions : BIO-RAD QC materials commonly used hospital and peer group by setting the measurement kit, suitable for laboratory equipment for radioimmunoassay of Acceptable Range manufacturer recommendation to increase the objectivity of the test results by national and international recognition for radioimmunoassay should seek to increase.

  • PDF

Effects of Anti-thyroglobulin Antibody on the Measurement of Thyroglobulin : Differences Between Immunoradiometric Assay Kits Available (면역방사계수법을 이용한 Thyroglobulin 측정시 항 Thyroglobulin 항체의 존재가 미치는 영향: Thyroglobulin 측정 키트에 따른 차이)

  • Ahn, Byeong-Cheol;Seo, Ji-Hyeong;Bae, Jin-Ho;Jeong, Shin-Young;Yoo, Jeong-Soo;Jung, Jin-Hyang;Park, Ho-Yong;Kim, Jung-Guk;Ha, Sung-Woo;Sohn, Jin-Ho;Lee, In-Kyu;Lee, Jae-Tae;Kim, Bo-Wan
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.4
    • /
    • pp.252-256
    • /
    • 2005
  • Purpose: Thyroglobulin (Tg) is a valuable and sensitive tool as a marker for diagnosis and follow-up for several thyroid disorders, especially, in the follow-up of patients with differentiated thyroid cancer (DTC). Often, clinical decisions rely entirely on the serum Tg concentration. But the Tg assay is one of the most challenging laboratory measurements to perform accurately owing to antithyroglobulin antibody (Anti-Tg). In this study, we have compared the degree of Anti-Tg effects on the measurement of Tg between availale Tg measuring kits. Materials and Methods: Measurement of Tg levels for standard Tg solution was performed with two different kits commercially available (A/B kits) using immunoradiometric assay technique either with absence or presence of three different concentrations of Anti-Tg. Measurement of Tg for patient's serum was also performed with the same kits. Patient's serum samples were prepared with mixtures of a serum containing high Tg levels and a serum containg high Anti-Tg concentrations. Results: In the measurements of standard Tg solution, presence of Anti-Tg resulted in falsely lower Tg level by both A and B kits. Degree of Tg underestimation by h kit was more prominent than B kit. The degree of underestimation by B kit was trivial therefore clinically insignificant, but statistically significant. Addition of Anti-Tg to patient serum resulted in falsely lower Tg levels with only A kit. Conclusion: Tg level could be underestimated in the presence of anti-Tg. Anti-Tg effect on Tg measurement was variable according to assay kit used. Therefore, accuracy test must be performed for individual Tg-assay kit.

Type-specific Amplification of 5S rRNA from Panax ginseng Cultivars Using Touchdown (TD) PCR and Direct Sequencing

  • Sun, Hun;Wang, Hong-Tao;Kwon, Woo-Saeng;Kim, Yeon-Ju;Yang, Deok-Chun
    • Journal of Ginseng Research
    • /
    • v.33 no.1
    • /
    • pp.55-58
    • /
    • 2009
  • Generally, the direct sequencing through PCR is faster, easier, cheaper, and more practical than clone sequencing. Frequently, standard PCR amplification is usually interpreted by mispriming internal or external regions of the target template. Normally, DNA fragments were eluted from the gel using Gel extraction kit and subjected to direct sequencing or cloning sequencing. Cloning sequencing has often troublesome and needs more time to analyze for many samples. Since touchdown (TD) PCR can generate sufficient and highly specific amplification, it reduces unwanted amplicon generation. Accordingly, TD PCR is a good method for direct sequencing due to amplifying wanted fragment. In plants the 5S-rRNA gene is separated by simple spacers. The 5S-rRNA gene sequence is very well-conserved between plant species while the spacer is species-specific. Therefore, the sequence has been used for phylogenetic studies and species identification. But frequent occurrences of spurious bands caused by complex genomes are encountered in the product spectrum of standard PCR amplification. In conclusion, the TD PCR method can be applied easily to amplify main 5S-rRNA and direct sequencing of panax ginseng cultivars.

Availability of Statistical Quality Control of Nuclear Medicine Blood Test Using Population Distribution (모집단 분포를 이용한 핵의학 혈액검사의 통계적 품질관리의 유용성)

  • Cheon, Jun Hong;Cho, Eun Bit;Yoo, Seon Hee;Kim, Nyeon Ok
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.1
    • /
    • pp.37-41
    • /
    • 2016
  • Purpose The importance of quality control by the error to a minimum, which for the purpose of enhancing the reliability of the examination is not be emphasized excess. Currently, most nuclear medicine laboratory are conducting the internal and external quality control, and they are applying the Levey-Jennings or Westgard Multi-Rules by using the commercialized quality control materials. The reliability of the nuclear medicine blood test which affects the diagnosis of patients and the treatment policy is being secured through this quality control activity. Therefore, researchers will evaluate the utility of the statistic quality control using the population distribution of the nuclear medicine blood test conducted targeting the checkup examinees by the additional technique of the reliability improvement. Materials and Methods A statistic analysis was performed about 12 items of the nuclear medicine blood test targeting 41,341 peoples who used the health screening and promotion center in Asan Medical Center from January, 2014 to December, 2014. The results of 12 items of the nuclear medicine blood test was divided into the monthly percentage of three groups: within reference values, over reference, and under reference to analyze the average value of the population distribution, standard deviation, and standard deviation index (SDI). Results The standard deviation of the population distribution mostly showed a result within ${\pm}2SD$ in all groups. However, When the standard deviation of the population distribution represented a result over ${\pm}2SD$, it was confirmed SDI was showing a result of SDI > -2 or SDI > 2. As a result of analyzing the population distribution of 12 items(AFP, CEA, CA19-9, CA125, PSA, TSH, FT4, Anti-Tg-Ab, Anti-TPO-Ab, Calcitonin, 25-OH-VitD3, Insulin) of the nuclear medicine blood part basic test, when SDI of the monthly percentage which deviated from the reference values was over ${\pm}2.0$, CA19-9 September was 2.2, Anti-Tg-Ab may was 2.2, Insulin January was 2.3, Insulin March was 2.4. It was confirmed these cases were attributed to the abnormality of the test reagent (maximum combination rate of isotope reagent declined) and the decline of the test response time. Conclusion The population distribution includes the entire attribute which becomes the study object. It is expected the statistic quality management using the population distribution which was conducted targeting the checkup examinees by dividing into three groups: within reference values, over reference, and under reference by means of this characteristics will be able to play a role of complementing the internal quality control program which is being carried out in the laboratory.

  • PDF

Efficient Application of Westgard Multi-Rules and Quality Control Implementation Improvement (Westgard Multi-Rules의 효율적 적용과 조치사항의 개선)

  • Jung, Heung Soo;Oh, Youn Jung;Bae, Jin Soo;Baek, Jin Young;Hwang, Bo ra;Shin, Yong Hwan
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.1
    • /
    • pp.60-64
    • /
    • 2017
  • Purpose Westgard multi-rules application based on test quality improvement and commercialized international standard has been widely used in quality control. However, it is difficult to applicate the Westgard multi-rules in nuclear medicine in vitro tests due to the larger sample sizes and the simultaneous measurement of quality control material and patient sample. This study investigated the usefulness of Westgard multi-rules application in nuclear medicine in vitro tests. Materials and Methods A total of 282 systematic error multi-rules (22s, 101s) recorded in the samsung medical center computer system from January 2013 to June 2016 along with 117 cases of corrective measure record was analyzed. The Quality control implementation is recorded in Hospital information system were divided into 4 high-level areas including quality control material error, experimental procedural error, Kit lot number management error, and others. To prevent quality control material error, the existing method that each staff used their own method was changed. The staff who in charge of managing the quality control material was designated and daily consumption amount of every test was strictly controlled by one person. To prevent other errors, every test step was standardized so that the entire test procedures are identically implemented. Results The total quality control implementation was 117 cases; As a result, 62 quality control material errors were 62 cases, experimental process errors were 24 cases, Kit lot number control errors were 18 cases, and other errors were 13 cases. The quality control material error was corrected and could be used fresh materials within 2 days after thawing. The cases of systemic error were decreased to causes as quality control material error. The quality control materials were reduced above 10 vials to a monthly average. In addition, these errors of experimental processing and Kit lot number were improved by test standardization. Consequently, the cases of 101s and 22s in systematic error rules decreased at least 2 cases to a monthly average. Conclusion To confirm of systematic error through multi-rules application quickly, it is necessary to base on management of the QC material, target values and standard deviation. Moreover, in the event of a systematic error, it was found important to record measures based on test cause analysis. The experiment results are expected to contribute to internal quality control improvement and prompt and accurate result reporting through error recording and causal analysis based on Westgard multi-rules analysis.

  • PDF

24hr Whole-Body Retension of $^{99m}Tc-Methylene$ Diphosphonate and Osteocalcin in patients with Hyperthyroidism (갑상선기능항진증에서 $^{99m}Tc-MDP$ 24시간 정체율과 Osteocalcin)

  • Yeoum, Kwang-Seop;Lee, Jin-Oh;Kang, Tae-Woong;Hong, Sung-Woon;Lim, Sang-Moo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.24 no.2
    • /
    • pp.222-228
    • /
    • 1990
  • The development of histomorphometric and histodynamic investigations has permitted the description of a specific and complex osteopathy in hyperthyroidism. The increased bone turnover rate in hyperthyroid patients may be accompanied by a considerable bone loss. These features are associated with both inclosed osteoclastic bone resorption and increased osteoblastric bone formation, with an accelerated calcification rate. Conventional biochemical markers of bone metabolism, i.e. serum calcium and alkaline phosphatase and urinary hydroxyproline and calcium are normal in most patients with hyperthyroidism. However, the correlation between serum BGP and serum concentration of thyroid hormon suggests that serum BGP may be a sensitive marker of increased bone formation due to the hypersecretion of thyroid hormones. Any increase in bone turnover, whether focal or diffuse, will result in an increase in $^{99m}Tc-methylenediphosphonate$ uptake (MDP). The measurement of this uptake in hyperthyroid patients by bone provides a sensitive and objective means of quantifying skeletal metabolism. Using a standard shadow-shield whole-body monitor and radioimmunoassay kit, we have measured whole-body retention of $^{99m}Tc-MDP$ up to 24hr and concentration of serum Osteocalcin in 20 patients with hyperthyroidism and in 42 normals. The results were as follows; 1) The average of serum Osteocalcin level in 42 patients with normals was $9.90{\pm}4.87(ng/ml)$ and in 20 patients with hyperthyroidism was $19.54{\pm}5.7(ng/ml)$. Both the averages of serum Osteocalcin and 24hr $^{99m}Tc-MDP$ uptakes in hyperthyroid patients were higher than those in normals. 2) $^{99m}Tc-MDP$ uptakes in skeletal system increased in proportion to normal ageing after 40 yrs old in 42 patients with normals. The average of $^{99m}Tc-MDP$ uptakes in hyperthyroid patients were higher than those in normals without related ageing. 3) A significant relationships between the $^{99m}Tc-MDP$ uptakes and serum Osteocalcin level were peformed (r=0.55, $y=17.58+6.7\times$). From the above results we concluded that the measurement of serum Osteocalcin and 24hr $^{99m}Tc-MDP$ uptakes can be used for evaluation of bone turnover as a specific marker in hyperthyroid patients.

  • PDF

Shear Bond Strength of Porcelain Repair Systems (도재 수리 시스템의 전단결합강도에 관한 연구)

  • Woo, Soo;Shin, Soo-Youn;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.22 no.3
    • /
    • pp.211-220
    • /
    • 2006
  • Need of porcelain-repair system is largely demanding as dental porcelain restorations are increased in clinical dentistry. This study investigated shear bond strength of commercial porcelain-repair systems on dental porcelain and their reliability. Experimental groups were as follows; Group A Super Bond C&B, Group B Porcelain repair kit, Group C Ceramic repair, and Group D Spectrum system as a control. Porcelain disks were fired and embedded in epoxy resin. Porcelain surface were ground using 220 grit SiC disk, then cleaned in ultrasonic bath. Then porcelain specimens were treated with each repair system. A clear polystyrene cylinder 3.5 mm in internal diameter was filled with composite resin. Then the resin cylinder was polymerized with a visible light curing unit. Thirty one specimens at each group were prepared and stored at $37^{\circ}C$ distilled water for 48 h. Specimens were tested in an Instron testing machine according to ISO TR 11405. Mean shear bond strength and standard deviation of each group was $15.7{\pm}4.1MPa$ (Group A), $12.8{\pm}4.9MPa$ (Group B), $7.2{\pm}3.0MPa$ (Group C) and $9.6{\pm}2.2MPa$ (Group D). ANOVA and Tukey HSD post-hoc test showed that there were significant differences between groups (p<0.05). Data of bond strength were analyzed with two-parameter Weibull distribution. Confidence interval of Weibull modulus (m-parameter) at 95% of Group A (3.5-6.3) and Group D (3.6-6.0) were significantly higher than Group B (2.2-3.7) and Group C (2.0-3.4). There was little correlation between mean shear bond strength and Weibull modulus. Results indicated that acid-etching of porcelain surface increased porcelain-resin shear bonding strength.