• 제목/요약/키워드: Internal noise

검색결과 617건 처리시간 0.032초

Influence of time-of-day on respiratory function in normal healthy subjects

  • Kwon, Yong Hyun
    • The Journal of Korean Physical Therapy
    • /
    • 제25권6호
    • /
    • pp.374-378
    • /
    • 2013
  • Purpose: Human body have biological rhythmic pattern in a day, which is affected by internal and external environmental factors. We investigated whether respiratory function was fluctuated according to the influence of time-of-day (around at 9 am, 1 pm, and 6 pm) in health subjects, using pulmonary function test (PFT). Methods: Eighteen healthy volunteers (8 men, mean ages; $22.4{\pm}1.6$, mean heights; $166.61{\pm}9.60$, mean weight; $59.3{\pm}10.3$) were recruited. Pulmonary function test (PFT) was measured at three time points in day, around 9 am, 1 pm, and 6 pm in calm research room with condition of under 55dB noise level, using a spirometer (Vmax 229, SensorMecis, USA). Forced vital capacity (FVC), forced expiratory volume at one second (FEV1), FVC/FEV1, and peak expiratory flow (PEF) were acquired. Results: In comparison of raw value of PFT among three time points, subjects showed generally better respiratory function at 9 am, than at other points, although no significance was found. In comparison of distribution of ranking for respiratory function in each individual, only PEF showed significant difference. In general, distributional ratio of subjects who showed best performance of respiratory function in a day was high. Conclusion: These findings showed that circadian rhythm by diurnal pattern was not detected on respiratory function throughout all day. But, best performance on respiratory function was observed mostly in the morning, although statistical significance did not exist.

Development of FPGA-based Programmable Timing Controller

  • Cho, Soung-Moon;Jeon, Jae-Wook
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.1016-1021
    • /
    • 2003
  • The overall size of electronic product is becoming small according to development of technology. Accordingly it is difficult to inspect these small components by human eyes. So, an automation system for inspecting them has been used. The existing system put microprocessor or Programmable Logic Controller (PLC) use. The structure of microprocessor-based controller and PLC use basically composed of memory devices such as ROM, RAM and I/O ports. Accordingly, the system is not only becomes complicated and enlarged but also higher price. In this paper, we implement FPGA-based One-chip Programmable Timing Controller for Inspecting Small components to resolve above problems and design the high performance controller by using VHDL. With fast development, the FPGA of high capacity that can have memory and PLL have been introduced. By using the high-capacity FPGA, the peripherals of the existent controller, such as memory, I/O ports can be implemented in one FPGA. By doing this, because the complicated system can be simplified, the noise and power dissipation problems can be minimized and it can have the advantage in price. Since the proposed controller is organized to have internal register, counter, and software routines for generating timing signals, users do not have to problem the details about timing signals and need to only send some values about an inspection system through an RS232C port. By selecting theses values appropriate for a given inspection system, desired timing signals can be generated.

  • PDF

관형 연소기의 열-음향 진동에 의한 소음 특성 예측 (Prediction of Thermo-acoustic Oscillation Characteristics in a Ducted Combustor)

  • 김재헌;이정한;이수갑;정인석
    • 한국음향학회지
    • /
    • 제18권7호
    • /
    • pp.56-66
    • /
    • 1999
  • 일반 내연기관이나 산업용로, 로켓 엔진 등의 기본적인 형상이라고 할 수 있는 관형 연소기에서 발생하는 연소 소음은 열-음향 되먹임 현상에 의해 야기되는 형태가 지배적이며. 심할 경우 시스템의 파괴를 야기할 수도 있는 중요한 문제이다. 본 연구에서는 열-음향 진동중에서도 열-기인 음향 진동으로 분류될 수 있는 현상에 초점을 맞추어 유동장, 음향장 및 연소 반응을 수치적으로 해석하여 여러 주어진 조건에 따른 정상적인 해석뿐만 아니라 음압 수준이나 기본 주파수 예측과 같은 정량적인 결과 도출을 효과적으로 수행할 수 있는 수치적 기법의 개발을 목적으로 하였다. 다양한 당량비를 가진 혼합기에 대해 수치 해석을 수행한 결과 실험 측정치의 경향과 잘 일치할 뿐만 아니라 정량적인 면에서도 상당히 정확한 예측을 할 수 있음을 확인하였다.

  • PDF

Performance and Flow Condition of Cross-Flow Wind Turbine with a Symmetrical Casing Having Side Boards

  • Shigemitsu, Toru;Fukutomi, Junichiro;Toyohara, Masaaki
    • International Journal of Fluid Machinery and Systems
    • /
    • 제9권2호
    • /
    • pp.169-174
    • /
    • 2016
  • A cross-flow wind turbine has a high torque coefficient at a low tip speed ratio. Therefore, it is a good candidate for use as a self-starting turbine. Furthermore, it has low noise and excellent stability; therefore, it has attracted attention from the viewpoint of applications as a small wind turbine for an urban district. However, its maximum power coefficient is extremely low (10 %) as compared to that of other small wind turbines. In order to improve the performance and flow condition of the cross-flow rotor, the symmetrical casing with a nozzle and a diffuser are proposed and the experimental research with the symmetrical casing is conducted. The maximum power coefficient is obtained as $C_{pmax}=0.17$ in the case with the casing and $C_{pmax}=0.098$ in the case without the casing. In the present study, the power characteristics of the cross-flow rotor and those of the symmetrical casing with the nozzle and diffuser are investigated. Then, the performance and internal flow patterns of the cross-flow wind turbine with the symmetrical casings are clarified. After that, the effect of the side boards set on the symmetrical casing is discussed on the basis of the analysis results.

가솔린 예혼합 압축 착화 엔진의 농후 한계에서 연소와 노킹 특성 (Knocking and Combustion Characteristics at Rich Limit of Gasoline HCCI Engine)

  • 염기태;장진영;배충식
    • 한국자동차공학회논문집
    • /
    • 제14권6호
    • /
    • pp.9-16
    • /
    • 2006
  • Variable valve timing is one of the attractive ways to control homogeneous charge compression ignition (HCCI) engine. Hot internal residual gas which can be controlled by variable valve timing(VVT) device, makes fuel evaporated easily, and ignition timing advanced. Regular gasoline was used as main fuel and di-methyl ether(DME) was used as ignition promoter in this research. HCCI engine operating range is limited by high combustion peak pressure and engine noise. High combustion pressure can damage the engine during operation. To avoid engine damage, the rich limits have to define using various methods. Peak combustion pressure, rate of cylinder pressure rise was considered to determine rich limit of engine operating range. Knock probability was correlated with the rate of cylinder pressure rise as well as the peak combustion pressure.

유한요소법을 이용한 수중 예인 선배열의 모델링 및 VIM 진동 해석 (Modeling of Towed Line Array Using Finite Element Method and Vibration Analysis of VIM)

  • 함일배;배수룡;정의봉
    • 소음진동
    • /
    • 제7권6호
    • /
    • pp.993-1000
    • /
    • 1997
  • This paper presents a new technique of mathematical treatment using a finite element model for analyzing the vibration of the towed line array. Since the towed line array has the axisymmetricity, axisymmetric elements are used in finite element modeling for the towed array structure. The fluid-structure interaction is also considered. The array consists of a series of identical substructures which can include internal structures such as spacers, hydrophones and ropes. That periodicity of substrucutres permits the substructure synthesis technique using characteristic wave guide for analyzing the response of towed array system. This synthesis technique can reduce the cost of computing the array response. It is suggested that a response of towed array can be computed by the finite element method and substructure synthesis technique using wave guide. Several experiments for towed array were performed to verify the present computation technique. The predicted vibration for the towed array shows good agreement with the measured result.

  • PDF

간접 힘 측정 방법과 가상 역행렬을 이용한 힘 예측 (Forces Prediction by Indirect Force Measurement and Pseudo-inverse Technique)

  • 안병하;심재술
    • 한국정밀공학회지
    • /
    • 제19권6호
    • /
    • pp.43-50
    • /
    • 2002
  • In the design of structure, the forces acting on tai structure are key parameter fur noise and vibration control. However, in the complex structure, the forces at the injection point on the structure cannot be measured directly. So, it is necessary to find out Indirect force evaluation method. In this paper, forces have been measured with In-situ vibration responses and system information. And, three existing techniques of indirect force measurement, vita. direct inverse. principal component analysis and regularization have been compared. This paper shows that multi-vibration responses are essential for talc precise estimation of the forces. To check these conditions, rotary compressor is adopted as test sample, because it is very difficult to measure the injection forces from internal excitation to shell. It alas also been obtained that relatively higher force is transmitted through three welding paths to the compressor shell. It shows a good agreement between direct and indirect force evaluation with curvature shell and plate.

HPLC를 이용한 랫트 혈장중의 딜타아젬 및 데아세틸딜티아젬의 정량 (HPLC Determination of Diltiazem and Deacetyldiltiazem in Rat Plasma)

  • 이용희;심창구;이민화;김신근
    • Journal of Pharmaceutical Investigation
    • /
    • 제22권4호
    • /
    • pp.317-321
    • /
    • 1992
  • A high-performance liquid chromatographic (HPLC) method was developed for the determination of diltiazem (DTZ) and its major metabolite, deacetyldiltiazem (DAD), in rat plasma. DTZ, DAD and imipramine, the internal standard, were selectively fractionated from plasma on a $C_{18}$ reversedphase column $({\mu}-Bondapak,\;10\;{\mu}m\;silica,\;300{\times}3.9\;mm\;ID)$. The composition of the mobile phase was methanol: acetonitrile: 0.04 M ammonium bromide: triethylamine (40:24:36:0.06 in volume). The pH of the mobile phase of their method was lowered to 6.4. The eluents from the column were detected for DTZ and DAD using a UV detector at 237 nm. The recovery was >85% for DTZ and DAD, and average intra-day and inter-day coefficients of variation were <6% for DTZ and DAD at the concentration ranges of 20-1000 ng/ml. Detection limit of DTZ and DAD in plasma was 20 ng/ml with signal-to-noise ratio of 3. This method would be applicable to practical pharmacokinetic studies without detriment to the HPLC column.

  • PDF

VISUALIZATION OF THE INTERNAL WATER DISTRIBUTION AT PEMFC USING NEUTRON IMAGING TECHNOLOGY: FEASIBILITY TEST AT HANARO

  • Kim Tae-Joo;Jung Yong-Mi;Kim Moo-Hwan;Sim Cheul-Muu;Lee Seung-Wook;Jeon Jin-Soo
    • Nuclear Engineering and Technology
    • /
    • 제38권5호
    • /
    • pp.449-454
    • /
    • 2006
  • Neutron imaging technique was used to investigate the water distribution and movement in Polymer Electrolyte Membrane Fuel Cell (PEMFC) at HANARO, KAERI. The Feasibility tests were performed in the first and second exposure rooms at the neutron radiography facility (NRF) at HANARO in order to check the ability of each exposure room, respectively. The feasibility test apparatus was composed of water and pressurized air before making up the actual test apparatus. Due to the low neutron intensity in the second exposure room, the exposure time was too long to investigate the transient phenomena of PEMFC. Although the exposure time was improved to 0.1 sec in the first exposure room, it was difficult to discriminate detail water movement at the channel due to the high noise level. Therefore, the experimental setup must be optimized according to the test conditions. Water discharge characteristics were investigated under different flow field geometries by using feasibility test apparatus and the neutron imaging technique. The water discharge characteristics of a 3-parallel serpentine are superior to those of a 1-parallel serpentine, but water at Membrane Electrode Assembly (MEA) was not removed, regardless of the flow field type.

Audiometric Calibration of Aural Acoustic Immittance Instrument: A Review of Acoustic Immittance Instrument's Calibration

  • Kim, Jin-Dong
    • 대한의생명과학회지
    • /
    • 제22권4호
    • /
    • pp.115-126
    • /
    • 2016
  • Audiometric calibration is a prerequisite for securing the reliability of audiometric test results by checking the internal consistency of the relevant instrument. The purpose of this review is to help instrument operators understand the calibration procedure of aural acoustic immittance instrument which is frequently used for objective assessment. By referring to the latest international standards and the national standards relevant to the aural acoustic immittance instrument, the following parameters will be reviewed: 1) introduction of performance characteristics, 2) detailed procedure of the calibration method. According to the newest international and national standards [IEC 60645-5 (2004), ANSI S3.39-1987 (R2012)], the aural acoustic immittance instrument basically includes six components: 1) calibration cavity, 2) acoustic immittance analysis system, 3) probe assembly/unit and signal, 4) pneumatic air-pressure pump system, 5) acoustic reflex activator system and 6) tympanogram and acoustic reflex plotting system, each of these components should meet set standards. The result of behavioral hearing tests is influenced by various complex factors including the examinee's cooperation, background noise of the examination room, measurement method, skill level of the audiologist and calibration status, but the objective hearing tests is more influenced by the calibration status of the instrument than any other factors. The audiologist should take full responsibility for the reliability of the hearing test result, so he/she should carry out the calibration check and adjustments of aural acoustic immittance instrument periodically and maintain the instrument continuously by referring to the newest standards and the manufacturer's instruction manual.