• Title/Summary/Keyword: Internal membrane

Search Result 537, Processing Time 0.032 seconds

Advanced Treatment of Wastewater from Food Waste Disposer in Modified Ludzack-Ettinger Type Membrane Bioreactor

  • Lee, Jae-Woo;Jutidamrongphan, Warangkana;Park, Ki-Young;Moon, Se-Heum;Park, Chul
    • Environmental Engineering Research
    • /
    • v.17 no.2
    • /
    • pp.59-63
    • /
    • 2012
  • This paper proposes a modified Ludzack-Ettinger (MLE) type membrane bioreactor (MBR) as a method of treatment for wastewater from food waste disposer. Micro-membrane filtration allows for an extremely low concentration of suspended solids in the effluent. The effluent of the reactor in question is characterized by a relatively high level of non-biodegradable organics, containing a substantial amount of soluble microbial products and biomass. Results obtained in this paper by measurement of membrane fouling are consistent with biomass concentration in the reactor, as opposed to chemical oxygen demand (COD). The MLE process is shown to be effective for the treatment of wastewater with a high COD/N ratio of 20, resulting in are markedly high total nitrogen removal efficiency. Denitrification could be improved at a higher internal recycle ratio. Despite the low concentration of influent phosphorus, the phosphorus concentration of the outflow is seen to be relatively high. This is because outflow phosphorous concentration is related to COD consumption, and the process operates at along solids retention time.

Shengmaisan Regulates Pacemaker Potentials in Interstitial Cells of Cajal in Mice

  • Kim, Byung Joo
    • Journal of Pharmacopuncture
    • /
    • v.16 no.4
    • /
    • pp.36-42
    • /
    • 2013
  • Objectives: Shengmaisan (SMS) is a traditional Chinese medicine prescription widely used for the treatment of diverse organs in Korea. The interstitial cells of Cajal (ICCs) are pacemaker cells that play an important role in the generation of coordinated gastrointestinal (GI) motility. We have aimed to investigate the effects of SMS in the ICCs in the mouse small intestine. Methods: To dissociate the ICCs, we used enzymatic digestions from the small intestine in a mouse. After that, the ICCs were identified immunologically by using the anti-c-kit antibody. In the ICCs, the electrophysiological whole-cell patch-clamp configuration was used to record pacemaker potentials in the cultured ICCs. Results: The ICCs generated pacemaker potentials in the mouse small intestine. SMS produced membrane depolarization with concentration-dependent manners in the current clamp mode. Pretreatment with a $Ca^{2+}$ free solution and thapsigargin, a $Ca^{2+}$-ATPase inhibitor in the endoplasmic reticulum, stopped the generation of the pacemaker potentials. In the case of $Ca^{2+}$-free solutions, SMS induced membrane depolarizations. However, when thapsigargin in a bath solution was applied, the membrane depolarization was not produced by SMS. The membrane depolarizations produced by SMS were inhibited by U-73122, an active phospholipase C (PLC) inhibitors. Furthermore, chelerythrine and calphostin C, a protein kinase C (PKC) inhibitors had no effects on SMS-induced membrane depolarizations. Conclusions: These results suggest that SMS might affect GI motility by modulating the pacemaker activity through an internal $Ca^{2+}$- and PLC-dependent and PKC-independent pathway in the ICCs.

REMOVAL OF DISSOLVED OXYGEN USING PVDF HOLLOW FIBER MEMBRANE CONTACTOR

  • Lee, Ki-Sub;Park, You-In;Yeon, Sun-Hwa;Sung, Kyung-Soo;Rhim, Ji-Won;Lee, Kew-Ho
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 2003.07a
    • /
    • pp.133-135
    • /
    • 2003
  • The removal of dissolved oxygen(DO) from water was studied using a poly(vinyliene fluoride)(PVDF) hollow fiber membrane contactor(HFMC) with the vacuum degassing process(VDP), Asymmetric porous PVDF hollow fiber membranes (HFM) for membrane contactor were prepared by a wet phase inversion method. In spinning of these PVDF hollow fibers, dimethy lacetamide (DMAc), LiCl and pure water were used as a solvent, a pore-forming additive and internal/external coagulant, respectively. The characteristics of the structure(pore size, porosity etc.) of the prepared PVDF HFMs as a function of concentration of pore-forming additive in polymer dope solution were studied. Also, the removal efficiency of DO from water according to flow rates of water, using PVDF HFMC with VDP, was studied. The performance of the asymmetric porous PVDF HFMC and a symmetric porous PP HFMC commercialized were compared. As a result, the asymmetric porous PVDF HFMC showed higher removal efficiency of DO than that of a symmetric porous PP HFMC.

  • PDF

Adjustment of Initial Shape for Spoked Wheel Cable Structures Considering Retractable Membrane's Tension (개폐식 막 장력을 고려한 스포크-휠 케이블 구조의 설계 형상 조절 기법)

  • Ha, Hyeonju;Shon, Sudeok;Lee, Seungjae
    • Journal of Korean Association for Spatial Structures
    • /
    • v.19 no.1
    • /
    • pp.109-116
    • /
    • 2019
  • In this paper, the shape adjustment algorithm of the spoked wheel cable structures with retractable membrane system is studied. The initial tension of the membrane or cable is necessary to form the structure and its value is determined by the design shape. However, due to internal and external environmental influences, its shape may be different from the initial designed shape. In the case of the cable structures covered in this study, tension adjustment is necessary to maintain the designed shape because it influences the tension of the cable depending on the state of the retractable membrane. Therefore, we proposed an adjustment algorithm of an initial shape based on the force method. The effectiveness and validity of the methodology were examined through the applicable cable structures. The results of the shape adjustment analysis of the symmetric spoked wheel cable model were reliable and accurate results were obtained.

Relationship Between Vascularity and Other Remodeling Parameters in Asthmatic Airway (기관지천식환자에서 기도내 혈관분포정도(vascularity) 및 다른 기도 재구성 소견과의 연관성)

  • Kim, Seung Joon;Lee, Sook Young;Kim, Myoung Sook;Lo, Dae Keun;Kwon, Soon Seog;Kim, Young Kyoon;Kim, Kwan Hyoung;Moon, Hwa Sik;Song, Jeong Sup;Park, Sung Hak
    • Tuberculosis and Respiratory Diseases
    • /
    • v.54 no.2
    • /
    • pp.191-198
    • /
    • 2003
  • Background : The pathological features in asthmatic airway remodeling are diverse. The aim of this study was to examine the degree of airway vascularity in relation to the other remodeling parameters in asthmatics. Methods : Bronchial biopsies were done in 34 asthmatic patients, and 6 control subjects. The basement membrane thickness and the subepithelial thickness were measured in the hematoxylin-eosin stained tissue, and the degree of vascularity was measured using type IV collagen immunostaining. Results : 1) Compared to the control subjects, the asthmatics showed a significant increase in the basement membrane thickness ($6.92{\pm}2.01{\mu}m$ vs $9.67{\pm}2.84{\mu}m$, p<0.05) and the subepithelial thickness ($44.49{\pm}31.92{\mu}m$ vs $121.22{\pm}72.79{\mu}m$, p<0.05). 2) Compared to the control subjects, the asthmatics showed a significant increase in the vascular area per unit submucosal area ($4.51{\pm}2.13%$ vs $10.32{\pm}6.08%$, p<0.05). In addition, the number of vessels per unit submucosal area showed an increased tendency without statistical significance. 3) In the asthmatics, the number of vessels and the vascular area per unit submucosal area showed no correlation with the basement membrane thickness, the subepithelial thickness, the severity, the forced expiratory volume in 1 second($FEV_1$), and the methacholine provocative concentration 20($PC_{20}$). Conclusion : This study showed that vascularity was an important parameter in asthmatic airway remodeling but it was not related to the other remodeling parameters such as the basement membrane thickness and the subepithelial thickness. Each of these asthmatic remodeling parameters may have a different clinical significance. Therefore, further studies will be needed.

A case of Bronchial Web (천식증상을 동반한 기관지 Web 1예)

  • Bae, Si-Hyun;Kim, Chi-Hong;Kim, Young-Kyoon;Kwon, Soon-Seog;Kim, Kwan-Hyoung;Han, Ki-Don;Moon, Hwa-Sik;Song, Jeong-Sup;Park, Sung-Hak
    • Tuberculosis and Respiratory Diseases
    • /
    • v.39 no.2
    • /
    • pp.176-179
    • /
    • 1992
  • Bronchial webs are rare lesions which often go unrecognized. A 36-year-old female was admitted to our hospital for recurrent cough and dyspnea. A diagnosis of bronchial asthma was made and she was treated with conventional therapy. She did not respond to drug therapy. On the physical examination, there was localized wheezing on the left lung field. By the bronchogram, we found a membrane-like structure in the left main bronchus. A bronchoplasty was performed and now the patient leads her normal life without any medications for asthma.

  • PDF

Internal Resorption의 증례보고

  • Hahm, Jhong-Dai;Cho, Kyew-Jeung;Kim, Doo-Hyun
    • The Journal of the Korean dental association
    • /
    • v.12 no.5
    • /
    • pp.357-359
    • /
    • 1974
  • 1. The author experienced a case of internal resorption of mandibular right second premolar. 2. The patient was 19 years old male. 3. Clinically the tooth had pinkish discoloration and extra cusp at crown portion 4. On X-ray picture, the tooth showed an ovoid shaped resorption at middle third portion of root canal and a thickening of periodontal membrane.

  • PDF

A Case of Goodpasture's Syndrome with Normal Renal Function (정상 신기능을 보인 Goodpasture 증후군 1예)

  • Kim, Sung Kyoung;Lee, Jin Kook;Joo, Kyeo Rae;Hur, Sung Eun;Kim, Jeong Hoon;Kim, Young Kyoon;Lee, Sook Young;Kim, Seung Joon;Kim, Chi Hong;Song, So Hyang;Park, Sung Hark;Choi, Young Jin
    • Tuberculosis and Respiratory Diseases
    • /
    • v.59 no.1
    • /
    • pp.86-92
    • /
    • 2005
  • Goodpasture's syndrome is a disease that is characterized by hemoptysis, anemia, and glomerulonephritis with renal failure. Goodpasture reported a case of a young man who expired as a result of a pulmonary hemorrhage and glomerulonephritis at the recovery phase after an influenza infection in 1919. In 1958, Stanton et al. described a combined case of these two diseases as Goodpasture's syndrome. Since then, antiglomerular basement membrane antibody(anti-GBM Ab) has been confirmed to play an important role in the mechanism of this syndrome, and it was reported that this syndrome was an autoimmune disease. The triad of alveolar hemorrhage, glomerulonephritis and circulating anti-GBM Ab forms the basis of a diagnosis of Goodpasture's syndrome. When patients are affected by disease, the relief of symptoms can be accomplished by eliminating the anti-GBM Ab from the circulatory system through hemodialysis, plasmapheresis and immunoabsorption. However, the patients usually die from a massive pulmonary hemorrhage when the diagnosis or treatment is delayed. The incidence of Goodpasture's syndrome is common in the western world, but it is extremely rare in Korea with only five cases being reported. In three of these cases, pulmonary hemorrhage and renal failure was the initial manifestation. Therefore, hemodialysis or plasmapheresis were absolutely essential treatments. We report a case of Goodpasture's syndrome in Korea with a normal renal function.

Design and Evaluation of a Lung Assist Device for Patients with Acute Respiratory Syndrome using Hollow Fiber Membranes (중공사 막을 이용한 급성호흡곤란증후군 환자용 폐 보조 장치의 설계와 평가)

  • Lee, Sam-Cheol;Kwon, O-Sung;Kim, Ho-Cheol;Hwang, Young-Sil;Lee, Hyun-Cheol
    • Membrane Journal
    • /
    • v.15 no.3
    • /
    • pp.224-232
    • /
    • 2005
  • The use of the lung assist device (LAD) would be well suited for acute respiratory failure (ARF) patients, combining the simplicity of mechanical ventilation with the ability of extracoporeal membrane oxygenators (ECMO) to provide temporary relief for the natural lungs. This study's specific attention was focused on the effect of membrane vibration in the LAD. Quantitative experimental measurements were performed to evaluate the performance of the device, and to identify membrane vibration dependence on blood hemolysis. We tried to decide upon excited frequency band of limit hemolysis when blood hemolysis came to through a membrane vibration action. The excited frequency of the module type 5, consisted of 675 hollow fiber membranes, showed the maximum gas transfer rate. We concluded that the maximum oxygen transfer rate seemed to be caused by the occurrence of maximum amplitude and the transfer of vibration to hollow fiber membranes. It was excited up to $25{\pm}5$ Hz at each blood flow rate of module type 5. We found that this frequency became the 2nd mode resonance riequency of the flexible in blood flow. Blood hemolysis was low at the excited frequency of $25{\pm}5$ Hz. Therefore, we decided that limit hemolysis frequency of this LAD was $25{\pm}5$ Hz.