• Title/Summary/Keyword: Internal loss

Search Result 1,362, Processing Time 0.029 seconds

Influence of Internal Partition of Simple Extension Chamber on the Acoustic Transmission Loss (단순 확장 관 내부 파티션이 음향 투과손실에 미치는 영향해석)

  • Park, Jeong-Pil;Jeong, Weui-Bong;Ahn, Se-Jin
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.690-692
    • /
    • 2014
  • To identify characterization of a simple extension chamber that have the two internal partition, produce the curve to estimate the transmission loss without the computer analysis. For helpful for internal optimum design, identify the characteristic of internal partition on transmission loss. Made estimated transmission loss curve by function of relationship of internal partition and transmission. Check the similarity of predicted transmission loss and analysis transmission loss. Usage of the predicted transmission loss made by relationship of internal partition and transmission loss is good information to place the internal partition so as to maximize the transmission loss on target frequency at optimal design on muffler.

  • PDF

The loss coefficient for fluctuating flow through a dominant opening in a building

  • Xu, Haiwei;Yu, Shice;Lou, Wenjuan
    • Wind and Structures
    • /
    • v.24 no.1
    • /
    • pp.79-93
    • /
    • 2017
  • Wind-induced fluctuating internal pressures in a building with a dominant opening can be described by a second-order non-linear differential equation. However, the accuracy and efficiency of the governing equation in predicting internal pressure fluctuations depend upon two ill-defined parameters: inertial coefficient $C_I$ and loss coefficient $C_L$, since $C_I$ determines the un-damped oscillation frequency of an air slug at the opening, while $C_L$ controls the decay ratio of the fluctuating internal pressure. This study particularly focused on the value of loss coefficient and its influence factors including: opening configuration and location, internal volumes, as well as wind speed and approaching flow turbulence. A simplified formula was presented to predict loss coefficient, therefore an approximate relationship between the standard deviation of internal and external pressures can be estimated using Vickery's approach. The study shows that the loss coefficient governs the peak response of the internal pressure spectrum which, in turn, will directly influence the standard deviation of the fluctuating internal pressure. The approaching flow characteristic and opening location have a remarkable effect on the parameter $C_L$.

A Study on Internal Loss Analysis of Totem Pole Bridgeless PFC and Efficiency Improvement using Parallel Switch (토템폴 브릿지리스 PFC의 내부 손실 분석과 병렬 스위치를 사용한 효율 개선에 관한 연구)

  • Yoo, Jeong Sang;Gil, Yong Man;Yu, Seung Hyup;Ahn, Tae Young
    • Journal of the Semiconductor & Display Technology
    • /
    • v.19 no.4
    • /
    • pp.22-27
    • /
    • 2020
  • In this paper, a generalized efficiency equation was proposed to estimate the internal loss of the SMPS (switched-mode power supply) with 3 variables. The first variable was an internal loss not related to the load current such as auxiliary power, the second was a loss proportional to the current such as diode loss, and the third was a loss proportional to square of the current such as conduction loss. Especially, theoretical internal losses of the totem pole bridgeless PFC which is widely used for high efficiency SMPS were expressed as output function to compare generalized efficiency equation. In addition, in order to reduce the conduction loss of the switch, when a multiple switch were paralleled, the correlation with the efficiency was analyzed and shown as a graph. In order to confirm the degree of the parallel switch structure on the efficiency improvement, a 2kW class totem pole bridgeless PFC was constructed and the effectiveness of the analysis was confirmed by comparing the generalized efficiency equation and theoretical loss analysis results with experimental data.

A Study on the Internal Loss and Efficiency Analysis by Loss Factors in PFC Switching Rectifier (PFC 스위칭 정류기에서 손실인자에 의한 내부손실과 효율분석에 관한 연구)

  • Tae Young Ahn
    • Journal of the Semiconductor & Display Technology
    • /
    • v.23 no.2
    • /
    • pp.50-54
    • /
    • 2024
  • In this paper, we propose a theoretical method to systematically analyze the power conversion efficiency of a single-phase PFC switching rectifier. Boost-type PFC was organized in order of highest correlation with load current using steady-state analysis results and introduced the concept of loss factor. The loss factors for each major element are summarized and presented in a table. This paper makes it easier to understand the internal loss and power conversion efficiency of the rectifier for loss factors. Lastly, to confirm the validity of the efficiency analysis results reflecting the loss factors, loss and efficiency analysis of the 2.5kW PFC rectifier was performed. The results were compared with data from a 2.5kW PFC circuit for evaluation. As a result, the usefulness of power conversion efficiency analysis reflecting the loss factors proposed in this paper was confirmed.

  • PDF

Vertigo and Sudden Hearing Loss Caused by Pontine Infarction (현훈과 돌발성 난청을 주소로 하는 뇌교경색)

  • Hyun, Min-Kyung;Sin, Won-Yong;Kim, Mi-Rang;Shin, Hyeon-Cheol;Jeong, Ji-Cheon;Yoon, Cheol-Ho;Jeong, Byoung-Mu
    • The Journal of Internal Korean Medicine
    • /
    • v.25 no.4
    • /
    • pp.200-206
    • /
    • 2004
  • Anterior inferior cerebellar artery(AICA) is a branch of the basilar artery which supplies the bloods for ventrolateral cerebellum and the lateral tegmentum of the lower two-thirds of pons. AICA occlusion can cause such symptoms as acute-onset unilateral deafness, vertigo, facial weakness and ataxia. A case of sudden hearing loss, facial palsy and vertigo caused by AICA territory infarction recently presented itself. Korean Oriental and Western medical therapy were applied in combination. Facial palsy and vertigo improved, but hearing loss did not improve. This case is reported with a brief overview of related literatures.

  • PDF

The Effect of Laser Geometry and Material Parameters on the Single Mode Gain Difference in Quarter Wavelength Shifted DFB Laser above Threshold Current (문턱전류이상에서 구조 및 재료 변수들이 $\lambda$/4위상천이 DFB 레이저의 단일모드 이득차에 미치는 영향)

  • 이홍석;김홍국;김부균;이병호
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.36D no.3
    • /
    • pp.75-84
    • /
    • 1999
  • Systematic studies for the effect of the linewidth enhancement factor, the confinement factor, the internal loss and the cavity length on the single mode gain difference and the frequency detuning are performed for $\lambda$/4 phase shifted DFB lasers above threshold. The above threshold characteristics are mainly determined by the linewidth enhancement factor, not by the confinement factor or the parameter defined by the product of the linewidth enhancement factor and the confinement factor. The normalized internal loss defined by the product of the internal loss and the cavity length mainly determines the above threshold characteristics compared to that of the internal loss or the cavity length alone. The effect of the cavity length on threshold characteristics is larger than that of the internal loss in the case of the same normalized internal loss. The above threshold characteristics of quantum well lasers are more resistant to the variations of the confinement factor and the normalized internal loss than those of bulk lasers due to the small linewidth enhancement factor.

  • PDF

Long-term effect of implant-abutment connection type on marginal bone loss and survival of dental implants

  • Young-Min Kim;Jong-Bin Lee;Heung-Sik Um;Beom-Seok Chang;Jae-Kwan Lee
    • Journal of Periodontal and Implant Science
    • /
    • v.52 no.6
    • /
    • pp.496-508
    • /
    • 2022
  • Purpose: This study aimed to compare the long-term survival rate and peri-implant marginal bone loss between different types of dental implant-abutment connections. Methods: Implants with external or internal abutment connections, which were fitted at Gangneung-Wonju National University Dental Hospital from November 2011 to December 2015 and followed up for >5 years, were retrospectively investigated. Cumulative survival rates were evaluated for >5 years, and peri-implant marginal bone loss was evaluated at 1- and 5-year follow-up examinations after functional loading. Results: The 8-year cumulative survival rates were 93.3% and 90.7% in the external and internal connection types, respectively (P=0.353). The mean values of marginal bone loss were 1.23 mm (external) and 0.72 mm (internal) (P<0.001) after 1 year of loading, and 1.20 mm and 1.00 mm for external and internal abutment connections, respectively (P=0.137) after 5 years. Implant length (longer, P=0.018), smoking status (heavy, P=0.001), and prosthetic type (bridge, P=0.004) were associated with significantly greater marginal bone loss, and the use of screw-cement-retained prosthesis was significantly associated (P=0.027) with less marginal bone loss. Conclusions: There was no significant difference in the cumulative survival rate between implants with external and internal abutment connections. After 1 year of loading, marginal bone loss was greater around the implants with an external abutment connection. However, no significant difference between the external and internal connection groups was found after 5 years. Both types of abutment connections are viable treatment options for the reconstruction of partially edentulous ridges.

Physical Characteristics of Internal Waves and the Effect of Short Depression Internal Wave on Acoustic Transmission in the East Sea (동해 내부파의 물리적 특성과 단주기 오목형 내부파가 음파전달에 미치는 영향)

  • Han, Bong-Wan;Lim, Se-Han;Park, Kyeong-Ju;Kim, Seong-Il
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.12 no.1
    • /
    • pp.37-43
    • /
    • 2009
  • Fluctuations in the ocean are closely related with the underwater acoustic propagation. Internal waves are generated by fluctuation of isopycnal layer in the upper part of the stratified ocean, which are propagated from offshore to coastal area. Physical characteristics of the internal waves existed in the East Sea were derived from the five field experimental data and the ocean monitoring buoy nearshore the mid-east coast of Korea. The dominant periods are appeared in the near-inertial period about $17{\sim}20hours$ and the short period about a few minutes. The wavelengths of them are $10{\sim}50km$ and $300{\sim}1000m$, and the phase speeds are $20{\sim}100cm/s$ and $30{\sim}70cm/s$, respectively The maximum amplitudes are about $20{\sim}25m$. Under the environment of short depression internal wave propagation, the variations of transmission loss field were investigated using an range-dependent acoustic transmission loss model(RAM). The result shows that the large irregular variations of transmission loss caused by progressing the internal wave from offshore toward coast.

Measurement of Near Field Sound Intensity and Loss Factor Using Plate Intensity Measurement (평판 인텐시티 측정을 통한 근접장 음향 인텐시티와 손실 계수 측정법)

  • 김용조;김양한
    • Journal of KSNVE
    • /
    • v.7 no.4
    • /
    • pp.589-596
    • /
    • 1997
  • A energy equation for a thin plate and surrounding fluid is derived. The equation essentially determines the relation between internal loss of thin plate, energy of acoustic radiation, and structure intensity. We attempted to use this relation to measure internal loss of thin plate. The significance of this approach is that internal loss at any point of a thin plate can be measured. The quality of this measure is dicated by the accuracy of associated measurement systems such as structure and acoustic intensity measurements. A strain gauge bridge system has been developed to measure structure intensity of thin plate. Its performance is tested by experiments.

  • PDF

Performance analysis of mixed-flow fans considering the low flow characteristics (저유량 특성을 고려한 사류 송풍기의 성능 해석)

  • Oh, Hyoung Woo;Kim, Kwang-Yong
    • 유체기계공업학회:학술대회논문집
    • /
    • 2000.12a
    • /
    • pp.110-115
    • /
    • 2000
  • The mean streamline analysis using the empirical loss correlations has been developed for performance prediction of industrial mixed-flow fan impellers in the present study. New simple, but effective, models for the additional Euler input work characteristic and an internal recirculation loss due to internal flow reversal under the low flowrate conditions are proposed in this paper. Comparison of overall performance predictions with six sets of test data of mixed-flow fans is accomplished to demonstrate the accuracy of the proposed models. Predicted performance curves by the present set of loss models agree fairly well with experimental data for a variety of mixed-flow fan impellers over the entire operating conditions. The prediction method presented herein can be used efficiently in the conceptual design phase of mixed-flow fan impellers.

  • PDF