• 제목/요약/키워드: Internal heating technique

검색결과 16건 처리시간 0.019초

유체에 잠겨있는 가는 열전대의 시간상수 측정 (Time Constant of a Fine-Wire Thermocouple Immersed to Fluids)

  • 송치성
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제22권2호
    • /
    • pp.190-199
    • /
    • 1998
  • a new measuring method is suggested to determine the time constant of a thermocouple wire to be applied for the measurement of the true fluid temperatures in varying flow states. Based on the techniques of internal heating which are commonly used to measure mean time constants we extend the existing method to measure instantaneous time constants continuously. A method of measurement and analysis is presented and verified experimentally.

  • PDF

고속 비행체 전자 장비의 안전성 예측을 위한 열해석 모델 구축 (The Development of Thermal Model for Safety Analysis on Electronics in High-Speed Vehicle)

  • 이진관;이민정;황수권
    • 한국항공우주학회지
    • /
    • 제49권5호
    • /
    • pp.437-446
    • /
    • 2021
  • 비행체의 속도가 빨라질수록, 비행 시 발생하는 공력 가열이 커진다. 고속 비행체의 속도가 빨라지면서 비행체의 외피는 수백 ℃까지 가열되기도 하며, 동시에 동체 내부의 전자장비들도 함께 가열되어 상대적으로 사용온도가 낮은 전자장비들의 열적 안전성이 위협받기 시작하였다. 이에 따라 개발 단계에서 전자장비의 온도 예측 및 외부시스템을 이용한 온도 조절 등 장비의 열적 안전성을 예측하고, 이를 확보하기 위한 다양한 시도가 있었다. 본 논문에서는 일회성 고속 비행체 내 장비의 열적 안전성을 예측할 수 있는 열 해석 모델을 구축하는 기술을 개발하였다. 장비 내부의 열전달 특성을 파악하기 위한 간단한 지상 모사실험을 수행하였고, 그 결과를 바탕으로 열전달 특성을 모사한 열 해석모델을 구축하였다. 이 기술을 활용하여 장비 열 해석 모델을 구축한다면, 비행 시장비 내부 구성품별 온도 변화를 예측할 수 있고, 더 나아가 열에 가장 취약한 특정 소자의 온도를 예측할 수 있기 때문에 더 정밀한 열적 안전성 예측이 가능하다.

한국형 패시브하우스를 위한 단열블럭시스템의 난방에너지소비 특성 (A Characteristic Heating-Energy Expend of Insulation Block System for Korea Type Passive House)

  • 강재식;최경석;양관섭;이승언
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.603-607
    • /
    • 2009
  • About a Structure is performance external insulation is fundamantal performance for enrgy-saving. these day, most of residential structures have constructed by internal insulation method structure. The method structure internal insulation have construction and economical efficiency, but on the other hand, be generated heat loss by heat bridge especially, be generated loss heat-energy logical consequence in structure ondol. The external insulation structure method has a mert able to minimum to loss heat about heat-bridge. But the external insulation technique is unsatisfactory statues within the know-how and method of construction and materials compared with developed countries. The recently, the requirement of market related to the external insulation technique is resulted by the energy efficiency system, but it can lead to the lack of alternative technique In study on the korea type passive house building design for insulation block method of wall system has to experimental characteristic heat-energy of practice building. In result field-experimental, the heat-bridge appeared to characteristic spent heat-energy of blow 2L class and have a suffience performance it.

  • PDF

Thermal Shock Resistance of $Al_{2}O_{3}$- and Fe-$Al_{2}TiO_{5}$-based Castable Refractories

  • Liu, T.;Latella, B.A.;Bendeich, P.
    • The Korean Journal of Ceramics
    • /
    • 제4권4호
    • /
    • pp.345-351
    • /
    • 1998
  • Thermal shock resistance of $Al_2O_3$- and Fe-$Al_2TiO_5$-based Castable Refractories was studied using a central heating technique. Ring type specimens, 10mm thick and 20 and 100mm inner and outer diameters, respectively, were rapidly heated on the internal surface of the centre hole using a high power electrical heating element. The temperature field was measured experimentally and modelled using finite element analysis (FEA). The thermal stress field was also modelled using FEA. A radial notch was introduced to the ring specimens to enable calculation of the thermal stress intensity factors (SIF). A special LVDT device was incorporated in the thermal shock tester to monitor crack mouth opening displacement (COD). The thermal shock fracture initiation and crack propagation behaviour of the castable refractories were ascertained using the COD measurements and the fracture mechanics analysis data.

  • PDF

Investigation of the effect of internal curing as a novel method for improvement of post-fire properties of high-performance concrete

  • Moein Mousavi;Habib Akbarzadeh Bengar
    • Computers and Concrete
    • /
    • 제33권3호
    • /
    • pp.309-324
    • /
    • 2024
  • Internal curing, a widely used method for mitigating early-age shrinkage in concrete, also offers notable advantages for concrete durability. This paper explores the potential of internal curing by partial replacement of sand with fine lightweight aggregate for enhancing the behavior of high-performance concrete at elevated temperatures. Such a technique may prove economical and safe for the construction of skyscrapers, where explosive spalling of high-performance concrete in fire is a potential hazard. To reach this aim, the physico-mechanical features of internally cured high-strength concrete specimens, including mass loss, compressive strength, strain at peak stress, modulus of elasticity, stress-strain curve, toughness, and flexural strength, were investigated under different temperature exposures; and to predict some of these mechanical properties, a number of equations were proposed. Based on the experimental results, an advanced stress-strain model was proposed for internally cured high-performance concrete at different temperature levels, the results of which agreed well with the test data. It was observed that the replacement of 10% of sand with pre-wetted fine lightweight expanded clay aggregate (LECA) not only did not reduce the compressive strength at ambient temperature, but also prevented explosive spalling and could retain 20% of its ambient compressive strength after heating up to 800℃. It was then concluded that internal curing is an excellent method to enhance the performance of high-strength concrete at elevated temperatures.

초음파 서모그래피를 적용한 피스톤 스커트 절단균열에 대한 비파괴 신뢰성 평가 (The Nondestructive Reliability Evaluation which it Applies Ultrasound Thermography about Cutting Crack of Piston Skirt)

  • 양용하;마상동;김재열
    • Tribology and Lubricants
    • /
    • 제26권6호
    • /
    • pp.336-340
    • /
    • 2010
  • Ultrasound thermography detects defects by radiating 20 ~ 30 kHz ultrasound waves to the samples and capturing the heat generated from the defects with the use of an infrared thermographic camera. This technology is being spotlighted as a next-generation NDE for the automobile and aerospace industries because it can test large areas and can detect defects such as cracks and exfoliations in real time. The heating mechanism of the ultrasound vibration has not been accurately determined, but the thermomechanical coupling effect and the surface or internal friction are estimated to be the main causes. When this heat is captured by an infrared thermographic camera, the defects inside or on the surface of objects can be quickly detected. Although this technology can construct a testing device relatively simply and can detect defects within a short time, there are no reliable data about the factors related to its detection ability. In this study, the ultrasound thermography technique was used to manufacture gasoline and diesel engine piston specimens, and nondestructive reliability tests to verify the applicability and validity of the ultrasound thermography technique.

회전하는 터빈 블레이드 내부 이차냉각유로에서 엇갈린요철과 평행요철이 열/물질전달에 미치는 영향 (Effect of Cross/Parallel Rib Configurations on Heat/Mass Transfer in Rotating Two-Pass Turbine Blade Internal Passage)

  • 이세영;이동호;조형희
    • 대한기계학회논문집B
    • /
    • 제26권9호
    • /
    • pp.1249-1259
    • /
    • 2002
  • The present study investigates the convective heat/mass transfer inside a cooling passage of rotating gas-turbine blades. The rotating duct has various configurations made of ribs with 70。 attack angle, which are attached on leading and trailing surfaces. A naphthalene sublimation technique is employed to determine detailed local heat transfer coefficients using the heat and mass transfer analogy. The present experiments employ two-surface heating conditions in the rotating duct because the surfaces, exposed to hot gas stream, are pressure and suction side surfaces in the middle passages of an actual gas-turbine blade. In the stationary conditions, the parallel rib arrangement presents higher heat/mass transfer characteristics in the first pass, however, these characteristics disappear in the second pass due to the turning effects. In the rotating conditions, the cross rib present less heat/mass transfer discrepancy between the leading and the trailing surfaces in the first pass. In the second pass, the heat/mass transfer characteristics are much more complex due to the combined effects of the angled ribs, the sharp fuming and the rotation.

분자간 충돌과정에 따른 병진-회전-진동에너지의 이완율 (The Effect of the Collision Process Between Molecules on the Rates of Thermal Relaxation of the Translational-Rotational-Vibrational Energy Exchange)

  • 허중식
    • 대한기계학회논문집B
    • /
    • 제28권12호
    • /
    • pp.1494-1500
    • /
    • 2004
  • A zero-dimensional direct simulation Monte Carlo(DSMC) model is developed for simulating diatomic gas including vibrational kinetics. The method is applied to the simulation of two systems: vibrational relaxation of a simple harmonic oscillator and translational-rotational-vibrational energy exchange process under heating and cooling. In the present DSMC method, the variable hard sphere molecular model and no time counter technique are used to simulate the molecular collision kinetics. For simulation of diatomic gas flows, the Borgnakke-Larsen phenomenological model is adopted to redistribute the translational and internal energies.

구조용 집성재 제조용 접착제(Phenol-Resorcinol-Formaldehyde Resin) 유전 가열을 위한 고주파 전기장 세기 추산 (Estimation of Radio Frequency Electric Field Strength for Dielectric Heating of Phenol-Resorcinol-Formaldehyde Resin Used for Manufacturing Glulam)

  • 양상윤;한연중;박용건;엄창득;김세종;김광모;박문재;여환명
    • Journal of the Korean Wood Science and Technology
    • /
    • 제42권3호
    • /
    • pp.339-345
    • /
    • 2014
  • 집성재의 생산성 향상을 위한 고주파 가열 경화기술에 대해 연구하였다. 고주파가 유전체에 가해지면 내부에서 에너지 손실에 의한 발열이 발생한다. 집성재를 구성하는 라미나와 접착제는 유전체이므로 집성재에 고주파를 주사하면 내부에서 발열이 발생한다. 집성재 제조에 이용되는 대부분의 상온 경화형 접착제는 고온에서 빠른 경화가 이루어지므로 고주파 가열 기술을 이용하면 집성재 내부 접착층의 온도를 상승시킴으로써 빠른 경화를 유도할 수 있다. 본 연구에서는 낙엽송재와 phenol-resorcinol-formaldehyde (PRF) 접착제의 유전 특성을 평가하고, 집성재 내부의 접착층의 빠른 경화를 유도하는 고주파 가열 경화 기작을 이론적으로 분석하였다. 연구 결과, 온도상승인자인 PRF 접착제의 상대손실계수가 낙엽송재의 상대손실계수에 비해 높았으나, 온도상승저해인자인 밀도와 비열도 높았다. 그러나 상대손실계수의 비율이 온도상승저해인자의 비율보다 높기 때문에 고주파 가열에 의한 발열량은 접착제에서 더 높을 것으로 예상된다. 이러한 실험 결과를 이용한 이론적 접근을 바탕으로, 접착층이 목표온도까지 상승하기 위한 ISM 영역의 고주파 주파수 별 전기장의 상대 세기를 추정하였다.

수주지열정의 지하수 유동 및 지열 이동 예측을 위한 수치 모델링 기법 개발 (Development of a Numerical Modeling Technique for Predicting Groundwater flow and Heat Transport in a Standing Column Well)

  • 박성민;황기섭;문종필;김중휘
    • 지질공학
    • /
    • 제26권4호
    • /
    • pp.461-471
    • /
    • 2016
  • 수주지열정의 지하수 유동 및 지열 이동 현상을 모사할 수 있는 수치 모델링 기법을 제시하기 위하여 열-수리학적 모델인 TOUGH2를 기반으로 한 모듈을 개발하였고 두 유형의 수주지열정에서의 냉방 및 난방 운영을 수치 모의하였다. 수치 모델링 결과들은 수주지열정의 냉난방 운영이 주변 지층 및 지하수와의 열교환 및 유체 혼합에 크게 영향을 받으며, 특히 PVC 또는 PE 파이프 내부와 수주지열정 내부에서 서로 반대방향으로 유동하는 유입수와 유출수 간의 열교환이 중요한 요소임을 보여준다. 또한 본 연구에서 개발 및 제안된 수치 모델링 기법이 수주지열정의 내부 구조 및 유체 유동과 열 이동 현상을 합리적으로 모사할 수 있음을 보여준다. 이러한 수치 모델링 기법은 수주지열정의 설계, 시공 및 운영 단계에서 열교환 성능을 정량적으로 분석할 때 유용하게 활용될 수 있을 것으로 기대된다.