• Title/Summary/Keyword: Internal flow control

Search Result 357, Processing Time 0.032 seconds

Analysis on the thermal development of radiatively participating pipe flow with nonaxisymmetric convective heat loss (비축대칭 대류열손실 경계조건하에서 원관내 복사에 관여하는 매질의 층류 열적 발달의 수치해석)

  • ;;Baek, Seung-Wook
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.11
    • /
    • pp.2995-3002
    • /
    • 1995
  • The cooling problem of the hot internal pipe flow has been investigated. Simultaneous conduction, convection, and radiation were considered with azimuthally varying convective heat loss at the pipe wall. A complex, nonlinear integro-differential radiative transfer equation was solved by the discrete ordinates method (or called S$_{N}$ method). The energy equation was solved by control volume based finite difference technique. A parametric study was performed by varying the conduction-to-radiation parameter, optical thickness, and scattering albedo. The results have shown that initially the radiatively active medium could be more efficiently cooled down compared with the cases otherwise. But even for the case with dominant radiation, as the medium temperature was lowered, the contribution of conduction became to exceed that of radiation.n.

An Investigationi into the Dynamic Characteristics of Turbine and Gear Motor Type Flowmeters (터빈형과 기어모터형 유량계의 동특성 검토)

  • 예용택
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.9 no.3
    • /
    • pp.83-89
    • /
    • 2000
  • In hydraulic control system turbine and gear motor type flowmeters are widely used to measure the flow rate under steady flow conditions. With the recent growth of interest in the measurement of instantaneous values of unsteady flow rate the test of the transient response of these flowmeters are in some significance. however an unsteady flow rate mea-surment and its calibration method with a fast response and a high accuracy have not beendeveloped. In this research particularly the dynamic characteristics of turbine and gear motor type flowmeters are investigated experimentally and simple mathematical models are proposed. The measured flow rate waveforms are compared with those by remote instan-taneous flow rate measurement method(RIFM) which has been developed by author and used for calibration As the result of frequency response test gain and phase between the measured flow rate waveforms by turbine type flowmeter and those estimated by RIFM are in good agreement up to 70Hz For the gear motor type flowmeter th simulated results by a math-ematical model proposed here agree well with the experiment nearly up to 100Hz. Also it if sound that the pressure drop across the flowmeter is increased in proportion to the frequency of the flow rate variation in a high frequency region of more than 100Hz. It can be explained that the dealy of gear motor type flowmeter in high frequency regionis mainly attributed to a first order delay consisting of the inertia of gears and internal leakage of the gear motor.

  • PDF

Performance Enhancement of Solar Thermal Storage Tank with Heat Exchange Coils (Part 1 : Verification Experiment) (열교환코일 내장형 태양열 축열조의 성능향상 (제1보 실증실험))

  • Lee, Uk-Jae;Hong, Hiki
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.4
    • /
    • pp.213-219
    • /
    • 2015
  • A thermal storage tank with internal heat exchange coils is commonly used in solar thermal systems with a collector area below $100m^2$. The coils are installed in the lower part of the tank because the temperature of the upper part of the tank can drop if the outlet temperature of the collector becomes lower than the upper temperature of the tank, which is a kind of temperature reversal. As an alternative to the well-mixed storage tank with lower coil only, we have proposed a tank with lower and upper coils and have achieved superior thermal stratification in the tank, which results in increased collector efficiency and solar fraction. But, the phenomenon of temperature reversal was often observed in the tank when the load or solar radiation changed rapidly. In the present work, revised control was successfully applied, i.e., to heat only the lower coil using a three way valve if temperature reversal occurs and to operate the collector at a low flow rate when the quality of solar radiation is not good.

Numerical Analysis of an Air-cooled Ammonia Condenser with Plate Fins

  • Kim, Young-Il;Kang, Byung-Ha
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.6
    • /
    • pp.104-112
    • /
    • 1998
  • Ammonia has been used as refrigerant for more than 100 years in absorption as well as in compression systems. Due to its poisonous and inflammable properties, however, its use has been mainly on heavy industrial plants in which regular maintenance is available. For these systems, condensers are generally water∼cooled. This is suitable for large systems over 20RT but is not suitable for small systems. In order to apply ammonia for a small system, it is important to adopt an air-cooled condenser. In this study, simple numerical analysis of an air-cooled condenser for an ammonia refrigeration system has been carried out. The condenser is designed as horizontal tubes with plate fins attached at the outer surface to enhance the air-side heat transfer rate. Effect of fin shape and arrangement are studied in detail. Since the local heat transfer coefficient is highest at the leading edge, heat flux is highest at the edge and decreases along the distance. Conditions of inlet air are also varied in the study and condenser length that is required for full condensation is calculated. The results show that it is important to enhance both the air-side and internal heat transfer coefficients.

  • PDF

Spray Characteristics of a Modulated Liquid Jet through 2nd Pulsed Control (2차 가진 제어 변조분사 특성 및 액체제트의 분무특성)

  • Kang, Young-Su;Lee, In-Chul;Koo, Ja-Ye
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.672-675
    • /
    • 2010
  • Spray characteristics for the modulation with a pulsed spray in low-frequency region were investigted by performing with additional internal pulsed injection. The 1st perturbative flow was generated by rotating-type pulsed device and the 2nd pulse source generated by the magnetic valve was used to modulate the 1st flow. A pattern of the modulated spray was observed through FFT result and visualization. In case of modulated spray with the 2nd pulse control, the width of up and down motion of the modulated spray is smaller than that of the spray without the 2nd pulse. Also, the depth of penetration of the down stream is higher than that of spray without the 2nd pulse.

  • PDF

Control of Subsurface Vortex on Cylindrical Sump Wall (원통형 펌프 흡입정 벽면에서 발생하는 수중 보텍스 제어)

  • Park, Young Kyu;Jeon, Joon Ho;Lee, Yoen Won
    • Journal of the Korean Society of Visualization
    • /
    • v.17 no.2
    • /
    • pp.73-82
    • /
    • 2019
  • The subsurface vortex - which occurs inside the cylindrical sump - was visualized through Computational Fluid Dynamics (CFD) and experiment. The analysis of subsurface vortex inside the cylindrical sump was already carried out using CFD techniques by the first author. To understand the subsurface vortex more clearly, an experimental analysis was carried out with a 1/5th scale model; and the flow rate was calculated according to the similarity law. The experimental results of vortex visualization matches well with the CFD results. The surface roughness model and Anti Vortex Device (AVD) model have been investigated to control the subsurface vortex. For the case of average surface roughness of 1mm and 5mm, the subsurface vortex appears and the vorticity is higher when compared to that of a smooth surface condition. However, for the AVD model, the subsurface vortex is completely removed and the internal flow is stabilized.

A Numerical Analysis on Flow and Strength of Ball Valve for petrochemistry (석유화학용 Ball Valve 유동 및 강도 수치해석)

  • Yi, Chung-Seub;Jeong, Hwi-Won;Jang, Sung-Cheol;Nam, Tae-Hee;Park, Jung-Ho;Yun, So-Nam
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.357-362
    • /
    • 2008
  • This study have goal with reverse engineering for petrochemistry of high pressure ball valve for localization. Ball valve for development accomplished with flow analysis based on provision of ANSI B16.34, ANSI B16.10, ANSI B16.25 In order to localize the petrochemistry high pressure control valve. Numerical simulation using CFD(Computational Fluid Dynamic) in order to predict a mass flow rate and a flow coefficient form flow dynamic point of view. The working fluid assumed the water($H_2O$). The valve inlet and outlet setup a pressure boundary condition. The outlet pressure was fixed by atmospheric pressure and calculated inlet velocity 5m/s. CFD solver used STAR-CCM+ which is commercial code. The result shows change of mass flow rate according to opening and closing angle of valve. Flow decrease observed open valve that equal percentage flow paten which is general inclination of ball valve. The structural analysis used ANSYS which is a commercial code. Stress analysis result of internal pressure in valve showed lower than yield strength. This is expect to need more detail design and verification for stem and seat structure.

  • PDF

The Effect of Magnolia Bark on the Metabolic Inflammation and Insulin Resistance of ob/ob Mice (후박(厚朴)이 ob/ob 마우스의 대사성 염증과 인슐린 저항성에 미치는 영향 및 관련기전에 대한 연구)

  • Kim, Hyo-jae;Kim, Eun-ji;Ma, Young-hoon;Han, Yang-hee
    • The Journal of Internal Korean Medicine
    • /
    • v.39 no.4
    • /
    • pp.751-763
    • /
    • 2018
  • Objective: This study was undertaken to investigate how magnolia bark extract affects ob/ob mouse in terms of metabolic inflammation and insulin resistance. Methods: Leptin-deficient ob/ob mice were divided into 2 groups (n=5): a normal saline treatment (=control) and magnolia bark treatment. Wild type mice were the lean group (n=5). After 5 weeks, we measured fasting blood sugar (FBS) and conducted oral glucose tolerance tests (OGTTs) in each group. After 6 weeks, we measured body weight, epididymal fat pad weight, liver weight, serum glucose, serum insulin, and gene expression of tumor necrosis factor-${\alpha}$, interferon-${\gamma}$, and interleukin-6. We characterized the phenotype of adipose tissue macrophages (ATMs) and analyzed fractions of the phenotype in each group by flow cytometry. Results: In the magnolia bark group, fasting blood sugar, oral glucose tolerance levels, and insulin resistance (HOMA-IR) were significantly decreased. The population and proportion of ATMs among leukocytes in adipose tissue were significantly decreased in the magnolia bark group. The population and proportion of M1 type ATMs among ATMs were significantly decreased in the magnolia bark group. Gene expression of tumor necrosis factor-${\alpha}$ was significantly decreased in the magnolia bark group. Conclusions: These results support a positive effect of magnolia bark on metabolic diseases such as insulin resistance and metabolic inflammation in leptin-deficient ob/ob mice.

Design of Integrated Control System for Combustion Type CO2 Generator with Solar Radiation Sensitiveness and Irrigation Supply (일사량 감응 및 관수공급이 가능한 연소형 CO2 발생기 통합 제어시스템의 설계)

  • Kim, Eung-Kon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.13 no.3
    • /
    • pp.617-622
    • /
    • 2018
  • Simultaneous control of blowers and heat exchangers affecting the air sealing and flow conditions inside the green house is essential to the management of $CO_2$ concentration. Currently, the demand for automation systems and integrated control is steadily increasing according to increasing of farm areas per person due to the reduction of agricultural population. This paper proposes the integrated control system that can control simultaneously the existing devices such as measurement switching devices which are important variables in the supply of $CO_2$, $CO_2$ generator fuel and combustion air mixture ratio(air-to-fuel ratio), and $CO_2$ supply control under internal and external conditions.

On the Introduction of the Internal Metering Policy in COSMOS (서울시 실시간 신호제어시스템(COSMOS)내 내부미터링 제어전략 도입 방안)

  • 이승환;이상수;이성호
    • Journal of Korean Society of Transportation
    • /
    • v.21 no.4
    • /
    • pp.79-90
    • /
    • 2003
  • Internal metering policy(IMP) is a control strategy to improve the quality of traffic flow within a network by avoiding queue spillback or intersection blockage. It is a more aggressive control strategy than the current control strategy employed in COSMOS. A preliminary study was made to incorporate the IMP logic within the COSMOS system to improve its' functionality at oversaturated conditions. From the study results, a set of guideline for real implementation was recommended : traffic conditions, detector configurations, and control procedures, etc. A simulation study was performed to evaluate the effectiveness of the proposed guidelines. It was shown that the occurrence of queue spillback was minimized. and overall network performance was also improved by applying IMP logic as compared to COSMOS control onl.