• Title/Summary/Keyword: Internal flow analysis

Search Result 982, Processing Time 0.024 seconds

Analysis for Internal Flow of Tube on the Self Inflating Tire Using the FSI Method (FSI 기법을 이용한 Self Inflating Tire의 펌핑 튜브 내부 유동 해석)

  • Kim, Myeongjun;Seong, Inchul;Hwang, Inkyeong;Park, Taewon
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.24 no.6
    • /
    • pp.660-667
    • /
    • 2016
  • Maintaining proper tire air pressure is an essential element in ensuring vehicle safety. UHP Tires that boast of many safety features are increasing in the market. In particular, the development of "Self-Inflating Tire" technology is accelerating around the globe. Self-inflating tire refers to a technique for maintaining appropriate tire pressure. An internal regulator senses when tire inflation pressure has dropped below the set air pressure. The tire boosts air through the valve when rolling and compressed air enters into the tire. This procedure keeps the tire air pressure at an appropriate level and increases tire safety. Flow analysis of the internal tube is required to examine self-inflating tires. In this study, a method of tube flow analysis using the FSI Method is proposed. The valve system is also implemented to optimize the regulator and sensor.

Internal Flow Analysis on the Fuel Cell's Blower (연료전지용 연료승압블로어 내부유동장 평가)

  • Jang, C.M.;Choi, K.R.;Tak, B.Y.;Kim, C.G.
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.87.2-87.2
    • /
    • 2011
  • This paper describes internal flow of a fuel cell's blower, which is mainly used for detached house and apartment. Test blower is operated by a diaphragm, which has suction and discharge port on the top of the blower. For analyzing the internal flow of the blower, three-dimensional Navier-Stokes analysis is introduced in the present study. Hybrid grid system consisted of hexa hedral, tetra hedral and prism mesh is adopted to describe the complex geometry of the diaphragm blower. Throughout the numerical simulation, it is found that the present numerical modeling for analyzing the internal flow of the test blower is suitable for understanding the unsteady nature inside the cavity of the diaphragm. Detailed unsteady flow is analyzed using the results obtained by numerical simulation.

  • PDF

Mass transfer in cross-flow dialyzer with internal recycle

  • Yeh, Ho-Ming;Chen, Chien-Yu
    • Membrane and Water Treatment
    • /
    • v.4 no.4
    • /
    • pp.251-263
    • /
    • 2013
  • The internal reflux effect on dialysis through the retentate phase of a countercurrently cross-flow rectangular module is investigated. Theoretical analysis of mass transfer in cross-flow devices with or without recycling is analogous to heat transfer in cross-flow heat exchangers. In contrast to a device without reflux, considerable mass transfer is achievable if cross-flow dialyzers are operated with reflux, which provides an increase in fluid velocity, resulting in a reduction in mass-transfer resistance. It is concluded that reflux can enhance mass transfer, especially for large flow rate and feed-concentration operated under high reflux ratio.

Influence of guide vane shape on the performance and internal flow of a cross flow wind turbine

  • Son, Sung-Woo;Singh, Patrick Mark;Choi, Young-Do
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.2
    • /
    • pp.163-169
    • /
    • 2013
  • In order to make the vertical-axis cross flow wind turbine commercially feasible, a guide vane is adopted and the effect of the guide vane shape is examined in order to improve the wind turbine performance. CFD analysis on the performance and internal flow of the turbine is carried out for the wind turbine model. The result shows that when the guide nozzle is installed, almost over two times of power coefficient are achieved in comparison with the case of no guide nozzle installation. The guide nozzle acts as a role of suppressing the flow resistance at the blade passage, which is found when the guide nozzle is installed. Moreover, in this study, two kinds of the guide vane with a straight type and a curved type are adopted and compared. The curved guide vane nozzle produces higher power coefficient in comparison with that of straight guide vane nozzle.

Performance and Internal Flow Characteristics of an Axial Flow Pump for a Floating Type Water Treatment System (부유식 수처리시스템용 축류펌프의 성능 및 내부유동)

  • Singh, Patrick Mark;Choi, Young-Do
    • The KSFM Journal of Fluid Machinery
    • /
    • v.17 no.3
    • /
    • pp.52-58
    • /
    • 2014
  • The development of efficient systems for water quality improvement for water sources such as lakes, dams and reservoirs has become a necessity to provide not only a cleaner and safer water to the urban society, but also to provide a cleaner and safer environment for the aquatic organisms living in lakes, dams and reservoirs. This study concentrates on the outlet design and internal flow analysis of an axial flow pump used in a floating type water treatment system completely powered by renewable energy source. The treatment system is designed to raise water from depths of about 3~5m up to the water surface where it is naturally mixed with air as it is released back to the reservoir. The outlet of a typical axial flow pump is modified to suit the floating type water mixer. The performance of the axial flow pump is studied by investigating the internal flow of the system. Results show that the change in outlet shape does not alter the performance of the original pump at the maximum efficiency point as long as the cross sectional area of inlet is the same as the outlet. The axial pump for floating type water treatment system has good cavitation performance in the whole flow passage.

Analysis on the performance and internal flow of a tubular type hydro turbine for vessel cooling system

  • Chen, Zhenmu;Kim, Joo-Cheong;Im, Myeong-Hwan;Choi, Young-Do
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.10
    • /
    • pp.1244-1250
    • /
    • 2014
  • The temperature of the main engine cabin of commercial vessel is very high. The material SS-316L undergoes creep damage at temperatures exceeding $450^{\circ}C$. It is essential to maintain the highly stressed engine cabin below the creep regime. Hence, seawater is employed in this kind of maritime vehicles as cooling liquid. It obtains the thermal energy at the cooling pipe line after passing through main engine cooling system. To harness the energy in the seawater, a turbine can be installed to absorb the energy in the seawater before being released into the sea. In this study, a cooling pipe line is selected to apply the tubular type hydro turbine for transferring the energy. Numerical analysis for investigating the performance and the internal flow characteristics of the tubular turbine is conducted. The results show that the maximum efficiency of 85.8% is achieved although the efficiency drops rapidly at partial flow rate condition. The efficiency descends slowly at the condition of excess flow rate. There is a relatively wide operating range of flow rate of this turbine to keep high efficiency at the excess flow rate condition. For the internal flow of the turbine, there is uniform streamline on the suction and pressure sides of the blade at the design point. However, the secondary flow appears at the suction and pressure sidesat the excess flow rate.In addition, it appears only at pressure side at the partial flow rate condition.

A NUMERICAL ANALYSIS OF THE TRAIN WIND IN THE SUBWAY TUNNEL (지하철 터널 내 열차풍의 수치해석적 연구)

  • Lee, J.H.;Juraeva, M.;Song, D.J.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2010.05a
    • /
    • pp.496-500
    • /
    • 2010
  • Understanding train-wind is the best method to know how to optimize subway ventilation system. The capacity and efficiency of the subway ventilation system are known by pressure and velocity while train runs. Analysis of the internal flow in subway tunnel and around subway station are studied using numerical methods. Characteristics of internal flow and influence of subway ventilation system for the subway station with platform screen door and tunnel are analyzed by unsteady state analysis. Velocity and pressure of train wind transformation are compared at around subway ventilation system and the internal flow is investigated at the subway tunnel.

  • PDF

Free Vibration of Marine Riser System with the Inclusion of Internal Flow (내부 유체흐름을 포함한 Riser System의 자유진동)

  • Namseeg Hong
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.8 no.4
    • /
    • pp.287-296
    • /
    • 1996
  • A mathematical model for the dynamic analysis of the riser system is developed to investigate the effect of internal flow on the free vibration of marine riser system which includes a steady flow inside the pipe. A semi-analytical method using series expansion is employed to derive Eigenvalue problem to facilitate the evaluation of the system frequencies, and its validity is given through the comparison of the solutions with the conventional method using system matrices. The algorithm is implemented to develop computer programs for the estimation of the system frequency. The investigations of the effect of internal flow on system frequency are performed according to the change of parameters such as top tension, internal flow velocity, and so on. It is found that the effect of internal flow can be controlled by the increase of top tension. However, careful consideration has to be given in the design point, particularly for the long riser.

  • PDF

Numerical Analysis of Flow Distribution in the Scaled-down APR+ Using Two-Equation Turbulence Models (2방정식 난류모델을 이용한 축소 APR+ 내부 유동분포 수치해석)

  • Lee, Gong Hee;Bang, Young Seok;Cheong, Ae Ju
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.4
    • /
    • pp.220-227
    • /
    • 2015
  • Complex thermal hydraulic characteristics exist inside the reactor because the reactor internals consist of fuel assembly, internal structures and so on. In this study, to examine the effect of Reynolds-Averaged Navier-Stokes (RANS)-based two-equation turbulence models in the analysis of flow distribution inside a 1/5 scaled-down APR+, simulation was performed using the commercial computational fluid dynamics software, ANSYS CFX R.13 and the predicted results were compared with the measured data. It was concluded that reactor internal flow pattern was locally different depending on the turbulence models. In addition, the prediction accuracy of k-${\varepsilon}$ model was superior to that of other two-equation turbulence models and this model predicted the relatively uniform distribution of core inlet flow rate.

CFD Analysis on the Performance and Internal Flow of a Micro Cross-Flow Hydro Turbine in the Range of Very Low Specific Speed (극저비속도 영역 마이크로 횡류수차의 성능 및 내부유동 수치해석적 연구)

  • Choi, Young-Do;Son, Sung-Woo
    • The KSFM Journal of Fluid Machinery
    • /
    • v.15 no.6
    • /
    • pp.25-30
    • /
    • 2012
  • Renewable energy has been interested because of fluctuation of oil price, depletion of fossil fuel resources and environmental impact. Amongst renewable energy resources, hydropower is most reliable and cost effective way. In this study, to develop a new type of micro hydro turbine which can be operated in the range of very low specific speed, a cross-flow hydro turbine with simple structure is proposed. The turbine is designed to be used at the very low specific speed range of hydropower resources, such as very high-head and considerably small-flow rate water resources. CFD analysis on the performance and internal flow characteristics of the turbine is conducted to obtain a practical data for the new design method of the turbine. Results show that optimized arrangement of guide vane angle and inner guide angle can give contribution to the turbine performance improvement.