믹서의 가동 수 및 각도 변화에 따른 유동형 지붕 탱크의 유동특성 (Flow Characteristics of Floating Roof Tank with Varying the Number of Operation and Angle)

  • 김노형
    • 한국유체기계학회 논문집
    • /
    • 제18권3호
    • /
    • pp.20-25
    • /
    • 2015
  • In this study, there are 6 mixers that are installed in a 600,000 barrel tank. We identified internal flow characteristics of floating roof tank with varying the number of operation from 4 to 6 because mixer is a variable that influence flow characteristics of the tank. And while varying an angle from Right $60^{\circ}$, Right $30^{\circ}$, Left $30^{\circ}$ to Left $60^{\circ}$, we identified internal flow characteristics of the tank. As a result, maximum velocity of flow was 0.02m/s stationarily when we changed the number of operation from 4 to 6. Maximum velocity of flow by change of an angle was from 0.42m/s to 0.47m/s. Therefore, we identified that these factors don't have a great influence on internal flow characteristics of a tank by investigating results with varying the number of operation and an angle.

내부 부상형 저장탱크(IFRT) 화재·폭발사고 원인 분석: OO송유관공사 저유소 화재·폭발사건을 중심으로 (Analysis of Cause of Fire and Explosion in Internal Floating Roof Tank: Focusing on Fire and Explosion Accidents at the OO Oil Pipeline Corporation)

  • 구채칠;최재욱
    • 한국화재소방학회논문지
    • /
    • 제34권2호
    • /
    • pp.86-93
    • /
    • 2020
  • 본 연구는 옥외저장탱크에서 발생한 화재·폭발사고의 근본적인 사례분석을 통해 저장탱크의 안전을 유지할 목적으로 수행되었다. 이 사고는 저장탱크 야드에 사업장 외에서 날아온 풍등이 저장탱크 주변 잔디에 떨어지며 발생한 잔재 화재가 서서히 확산되어 탱크 내부의 유증기와 만나 폭발·화재로 이어진 사고였다. 사고의 원인을 밝혀내기 위하여 CCTV영상분석을 통한 대기확산 조건 도출, 전산유체역학을 이용한 풍향 분석, 플러팅 루프가 최저 위치일 때의 탱크 내부 유증기 발생량, 최고 위치일 때의 탱크 내부 유증기 거동을 통하여 저장탱크의 폭발이 일어난 원인을 밝혀내어 저장탱크의 레벨을 내부부상형 지붕 이하로 유지했을 경우 위험물이 충전되면서 그 공간에 있던 유증기가 내부 부상지붕위에 정체될 가능성이 있으므로 저장탱크의 Low liquid level이 폰튠 서포트 밑에 위치하지 않도록 운전절차를 개선하고, 오픈 벤트에는 화염방지기를 설치하여 화염이 저장탱크로 유입하지 못하도록 하는 대책을 제시하고자 한다.

사고사례 정밀분석을 통한 상압저장탱크의 안전에 관한 연구 (A Study on Safety of Atmospheric Storage Tank through Detailed Analysis of Accident Case)

  • 임지표;박수율
    • 한국안전학회지
    • /
    • 제34권4호
    • /
    • pp.41-48
    • /
    • 2019
  • In October 2018, a large fire occurred after an explosion in an internal floating roof tank (IFRT) that stores gasoline by wind lantern in Goyang city, Gyeonggi-do. Although there was no casualty damage, the fire inside the tank lasted for 17 hours, and caused a great wave socially, and it was a chance to review the safety of the atmospheric storage tank. In this study, the necessity of installing a flame arrester at peripheral vents was examined through the calculation of the size of ventilation pipe and ventilation rate of internal floating roof tanks in terms of the function of the peripheral vent. Next, the necessity of the emergency shut-off valve linked with the high-level alarm to prevent the overflow of the atmospheric storage tank was confirmed by LOPA. Finally, safety measures to prevent overpressure, flame propagation and overflow which cause major accidents in atmospheric storage tank are suggested.

내부 부상형저장탱크(IFRT) 화재·폭발 예방대책에 관한 연구 (Study of Fire and Explosion Prevention of an Internal Floating Roof Tank)

  • 구채칠;최재욱
    • 한국화재소방학회논문지
    • /
    • 제33권1호
    • /
    • pp.45-49
    • /
    • 2019
  • 본 연구는 옥외저장탱크에서 발생한 화재의 근본적인 원인분석을 통해 저장탱크의 안전을 유지할 목적으로 수행되었다. 옥외저장탱크는 위험물을 장기간 저장하기 위한 고정장치로 탱크본체 및 부속장치로 구성되며, 부속장치는 벤트 시스템, 브레더 밸브, 화염방지기 등으로 구성된다. 화염방지기는 옥외저장탱크의 화재 폭발을 방지하기 위해 필요한 안전장치이다. 하지만 최근 발생한 옥외저장탱크 화재를 계기로 기존에 설치되어 운용중인 옥외저장탱크에 안전성 확보 차원에서 화염방지기를 의무적으로 설치해야 하는지 국내 외 기준을 비교 분석하여 화염방지기 설치가 필요함을 제시하였고, 화염방지기의 성능을 검증할 수 있는 국내기준이 부족하므로 외국 기준을 참고하여 보완할 필요성이 있다.