• Title/Summary/Keyword: Internal filling

Search Result 195, Processing Time 0.027 seconds

Analysis of Left Ventricular Diastolic Function in Coronary Artery Disease with Gated Blood Pool Scan (관상동맥질환에서 Gated Blood Pool Scan을 이용한 좌심실 확장기능의 분석)

  • Choi, Chang-Woon;Lim, Sang-Moo;Chung, June-Key;Lee, Myung-Chul;Park, Young-Bae;Seo, Joung-Don;Lee, Young-Woo;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.20 no.2
    • /
    • pp.39-45
    • /
    • 1986
  • Resting gated blood pool scan was used to derive left ventricular functional changes in normals (N=13, mean age=43) and in patients with coronary artery disease (N=50, mean age=53). Peak filling rates, average filling rates, and ejection fractions were significantly depressed in coronary artery disease. (p<0.0005, each other). And in coronary artery disease with normal ejection fraction (N=21), peak filling rates and average filling rates were depressed also, and peak filling rates of coronary artery disease with normal ejection fraction were abnormal in 61.2% and average fillin rates were abnormal in 71.4%. It appears that (1) resting peak filling rates and average filling rates were sensitive and easily obtainable parameters of the diastolic dysfunction assosiated with coronary artery disease, (2) a significant proportion of coronary artery disease patients without any evidence of abnormal systolic function have depressed resting peak filling rates and average filling rates of the left ventricle.

  • PDF

A study on the filling imbalances in hot-runner mold for internal gear based on injection molding (내측 기어 성형용 핫러너 금형에서의 충전불균형에 관한 연구)

  • No, Byung-Soo;Jea, Duck-Gun;Jeong, Yeong-Deug
    • Design & Manufacturing
    • /
    • v.2 no.3
    • /
    • pp.1-5
    • /
    • 2008
  • Plastic parts are molded for the purpose of mass production in injection molding. Therefore designer is usually designing molds that has geometrically balanced hot runner lay-out for filling balance at cavities. Although, mold is manufactured with geometrically balanced runner lay-out, there are actually filling imbalances in cavities. These filling imbalances phenomenon are caused by complicated interaction between melt and mold. In this paper, filling imbalances for internal gear based on injection molding in hot-runner mold were investigated by CAE and injection molding experiences.

  • PDF

An Experimental Study on Internal Temperature Changes of Type Ⅳ Cylinder according to Filling with Compressed Hydrogen Gas (압축수소가스 충전에 따른 타입 IV 용기의 온도 변화에 관한 실험적 연구)

  • Lee, Seung-Hoon;Kim, Youn-Gyu;Yoon, Kee-Bong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.644-647
    • /
    • 2009
  • In this paper, the study is researched for related safety standards having experiments concerning temperature changes in type IV cylinder of the Hydrogen fuel cell vehicle. Experiments were performed to acquire temperature data of type IV cylinder according to filling time. The experimental results are shown that internal temperatures of type Ⅳ vessel are over $85^{\circ}C$ at all measured points after 5 minutes at filling 35 MPa and the highest temperature is getting lower when the residual gases are more remained. Consequently, the safety standards need properly limited value through further study for filling flow rate and filling time.

  • PDF

COMPARISON OF CANAL FILLING EFFICIENCY ON THE INTERNALLY RESORBED ROOT ACCORDING TO CANAL FILLING TEHNIQUES (근관충전방법에 따른 내흡수 치근의 근관충전 효율성 비교)

  • Ha, Sang-Yoon;Shin, Dong-Hoon;Hong, Chan-Ui
    • Restorative Dentistry and Endodontics
    • /
    • v.20 no.2
    • /
    • pp.789-801
    • /
    • 1995
  • Canals with artificially made internal resorption were filled with 4 techniques(Lateral condensation, Ultrafil, Obtura II, Thermafil) to compare the efficacy of canal filling according to the filling techniques. After canal filling, radiographic examination, dye penetration through the apical portion and percentage of G-P filled area on the internal resorption area were evaluated. To examine the degree of crystal-like structure and the interface between filled G-P and canal wall, SM and SEM images were taken too. The results were as follows : 1. There was no statistically significant difference in apical microleakage among the 4 root canal filling techniques. 2. As a result of radiographic examination, Ultrafil was the best and Obtura II was acceptable but Lateral condensation and Thermafil showed unfavorable canal filling pattern similarly. 3. Ultrafil filled most of artificially made internal resorption area and Obtura II, Lateral condensation, Thermafil in that order filled unfavorably. 4. Degree of crystal like structure was the highest in the group filled with Ultrafil and those of Obtura II and Thermafil were similar and that of gutta percha used in Lateral condensation showed the lowest value. 5. Penetration of gutta percha into the dentinal tubules couldn't be seen in all groups. In the contact surface between the filled G-P and the canal wall, Lateral condensation showed relatively close sealing, Obtura II and Thermafil had irregular contact surface and Ultrafil showed regular filling pattern. 6. Contact surface between the core of Thermafil and the gutta percha showed close relationship without gap formation.

  • PDF

Automatic Calculation of Interior Volume of Refrigerator by Hole Filling Algorithm (분해모델과 구멍 메움 알고리즘을 이용한 냉장고 내부 용적의 자동 계산)

  • Park, Raesung;Fu, Jianhui;Jung, Yoongho;Park, Mingeun
    • Korean Journal of Computational Design and Engineering
    • /
    • v.22 no.1
    • /
    • pp.59-69
    • /
    • 2017
  • Internal capacity of a refrigerator is an important indicator for design and purchasing criteria. The components facing the internal space may have holes or gaps between parts. In traditional way, design engineers manually remodeled the parts to fill the holes and the gaps for enclosed boundary of the internal space. Then they calculated internal volume by subtracting the assembly of parts from its enclosing volume. However, filling holes and gaps is not an automated process requiring a plenty of labor and time. In this research, we have developed a voxel-based method to estimate the internal volume of a refrigerator automatically. It starts transforming all components facing the interior space into voxels and fills all holes and gaps automatically by the developed hole-filling algorithm to form a completely closed boundary of the assembly. Then, it identifies the boundary voxels that are facing to the internal voxels with any part of the component. After getting the intersection points between the boundary voxels and the surfaces of components, it generates the boundary surface of triangular facets with the intersection points. Finally, it estimates the internal volume by adding volume of each tetrahedron composed of a triangle of boundary surface and an arbitrary point.

Basic Research on 3D Cultural Heritage Packaging Technology Using Thermoplastic Polyurethane Elastomers

  • Oh, Seung-Jun;Wi, Koang-Chul
    • Journal of Conservation Science
    • /
    • v.37 no.1
    • /
    • pp.55-62
    • /
    • 2021
  • This study investigated mechanical property changes by measuring compression factors, resilience, and compressive strength according to packaging pattern and filling rate to identify the applicability of cultural heritage packaging using thermoplastic polyurethane elastomers (TPU). Research results indicate that the cross-shaped 3D pattern showed the best resilience when the internal filling rate was 20%, while the octet pattern was the best when the filling rate was either 40 and 60%. The octet pattern had the best mechanical properties and stability with resistance capacities of 20.79 kgf/cm2, 40.40 kgf/cm2, and 82.23 kgf/cm2 at 38%, 39%, and 40% recovery speeds, respectively, depending on the internal filling rate (20, 40, 60%). Based on these results, basic data on the applicability, stability, and reliability of 3D cultural heritage packaging materials using TPU materials were obtained.

Effect of Gastric Filling on the Images of Hepatic Scintigraphy (위의 충만유무에 의한 간신티그램영상의 변화)

  • Lee, J.S.;Choi, M.S.;Sung, C.M.;Lee, J.Y.;Lee, K.H.;Sohn, I.
    • The Korean Journal of Nuclear Medicine
    • /
    • v.23 no.2
    • /
    • pp.189-193
    • /
    • 1989
  • To observe the effect of gastric filling on the images of hepatic scintigraphy, we performed hepatic scintigraphy using $^{99m}Tc-tin$ colloid in twenty patients both in the fasting state and after meal, and made the visual comparison of both images. We found that gastric filling could cause some of the following changes in individual patients. 1) In the anterior view, the distance between the liver and the spleen increased and the interlobar notch of the inferior hepatic border was obliterated. The spleen was displaced downwards, its radioactivity in the upper medial part was reduced, and its upper pole was laterally displaced. 2) In the posterior view, the left lobe of the liver was separated from the spleen and the distance between the liver and the spleen increased. 3) In the right lateral view, the notch separating the right and the left lobes of the liver was well demarcated. 4) In the left lateral view, the spleen was separated from the liver and the distance between the liver and the spleen increased. The shape of the spleen was also changed. In case of the follow-up study, above changes should make one consider the possibility of the effect of gastric filling.

  • PDF

A Study on Heat Transfer Performance with the Changes of Working Fluid Filling Ratio for Thermosyphon with Internal Groove (내부 그루브를 가진 열사이폰의 작동유체 봉입량 변화에 따른 열전달 성능에 관한 연구)

  • Ye, S.S.;Han, K.I.
    • Journal of Power System Engineering
    • /
    • v.4 no.3
    • /
    • pp.19-24
    • /
    • 2000
  • This study concerns the performance of the heat transfer of the thermosyphon having 80 internal groove in which boiling and condensation occur. Distilled water has been used as a working fluid. The liquid filling as the ratio of working fluid volume to total volume of thermosyphon has been used as the experimental parameters. The heat flux and heat transfer coefficient at the condenser are estimated from the experimental results. The experimental results have been assessed and compared with the existing theories. As a result of the experimental investigation, the maximum heat flow rate in the thermosyphon is proved to be dependent upon the liquid fill quantity. relatively high rates of heat transfer have been achieved operating in the thermosyphon with the internal groove. Also, a thermosyphon with the internal groove can be used to achieve some inexpensive and compact heat exchangers in low temperature. In addition, overall heat transfer coefficients and the characteristics as an operating temperature are obtained for the practical applications.

  • PDF

A Study on Optimal Design of CNG Charging Nozzle Considering Flow Characteristics (유동특성을 고려한 CNG 충전 노즐의 최적 설계에 관한 연구)

  • Gwak, Gi-Myung;Baek, Jin-Uk;Kim, Nam-Yong;Cho, Yong-Min;Lyu, Sung-Ki
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.21 no.6
    • /
    • pp.15-21
    • /
    • 2022
  • This study considered the internal flow considering the internal shape of the CNG filling nozzle, which is widely distributed in Korea. The CNG filling nozzle is the last part to pass through in the CNG filling process and has a significant influence on the filling efficiency. The mechanism was identified by disassembling the CNG filling nozzle and performing a flow analysis according to the mechanism. Consequently, the energy loss owing to eddy currents in the flow was determined, and modeling was proposed to reduce the energy loss by simplifying the shape and parts.

A Study on Site to Build Hydrogen Multi Energy Filling Station in Domestic LPG Station (국내 LPG 충전소 내 수소 융·복합충전소 구축 가능 부지 연구)

  • PARK, JIWON;HUH, YUNSIL;KANG, SEUNGKYU
    • Journal of Hydrogen and New Energy
    • /
    • v.28 no.6
    • /
    • pp.642-648
    • /
    • 2017
  • The use of fossil is causing enviromental all over the world. So hydrogen energy is attracting attention as one of the alternative. The government announced that 30% of the air pollution is because of the Internal Combustion Engine Vehicle. In addition, they plans to reduce Internal Combustion Engine Vehicles by 2030 and increase (electric vehicles, EV) or (fuel cell vehicle, FCV). The FCV is evaluated as a next-generation green car because it has a long driving distance and short charging time. However, the hydrogen industry is not able to expand due to the lack of refueling infrastrucutre. This paper predicts the site of hydrogen refueling stations for the expansion of the hydrogen industry and proposes a method to supply hydrogen multi energy filling stations.