• Title/Summary/Keyword: Internal displacement

Search Result 543, Processing Time 0.029 seconds

Clinical and Radiological Analysis and Results after Anatomical Reduction and Bone Graft for Symptomatic Os Subfibulare (증상을 동반한 비골하 부 골에 대한 임상적 방사선학적 분석과 해부학적 정복술 및 골 이식술 후 결과)

  • Hwang, Pil-Sung;Kim, Do-Young;Park, Yong-Wook;Lee, Sang-Soo;Suh, Dong-Hyun;Kim, Hyong-Nyun
    • Journal of Korean Foot and Ankle Society
    • /
    • v.9 no.2
    • /
    • pp.162-166
    • /
    • 2005
  • Purpose: To analyze the clinical and radiological feature of Os subfibulare and to evaluate the results after anatomical reduction and internal fixation with bone graft for Os subfibulare. Materials and Methods: Forty-two cases, which underwent anatomic reduction and bone graft for Os subfibulare from October 1998 to September 2004 were reviewed. We analysed preopertive symptoms and onset of symptoms and radiologically measured the size and amounts of displacement of Os subfibulare under the inversion stress. Postoperatively we evaluated the clinical results measured by Hasegawa method and evidence of union. Results: Preoperatively there were only pain around the lateral malleolus in 16 cases, only instability of ankle joint in 3 cases, and pain and instability in 23 cases. The age of symptom onset averaged 23 years(range, 13-38 years). Radiographically Os sufibulare anteriorly located from lateral malleolus were in 40 cases, posteriorly situated in 2 cases. The size of Os subfibulare ranged from $1{\times}4\;mm$ to $8{\times}17\;mm$. In 22 cases of inversion stress view, displacement of the Os sbufibulare averaged $1.5{\pm}1.1\;mm$ (0 to 5 mm). The postoperative clinical results were excellent in 41 cases, poor in 1 case. There were complications of 1 case of irritation of sural nerve, 1 case of nonunion. Conclusion: Anatomic reduction and bone graft is effective treatment method for symptomatic Os subfibulare.

  • PDF

Structural Integrity Evaluation of Nozzle Assembly using Acoustic Emission Technique (음향방출법을 응용한 노즐 조립체의 구조건전성 평가)

  • 설창원;이기범
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.34 no.10
    • /
    • pp.32-39
    • /
    • 2006
  • An acoustic emission technique was applied to the structural strength test for the structural integrity evaluation of the nozzle assembly. These AE results were compared with data from the strain gages and displacement transducer. NDT using X-ray technique was performed to improve the test reliability before and after each test. In this structural integrity evaluation of the nozzle assembly, the internal crack initiation in the structure could not be precisely revealed by the strain and displacement results but the location and load level of the initiated crack could be precisely evaluated by using AE technique. From this test, it was proven that some new cracks can be generated in composite liner of nozzle assembly under the unexpected load due to interference between obturator and nozzle and these can be a cause of the unexpected abnormal failure.

Opitmal Design Technique of Nielsen Arch Bridges by Using Genetic Algorithm (유전자 알고리즘을 이용한 닐센아치교의 최적설계기법)

  • Lee, Kwang Su;Chung, Young Soo
    • Journal of Korean Society of Steel Construction
    • /
    • v.21 no.4
    • /
    • pp.361-373
    • /
    • 2009
  • Using the genetic algorithm, the optimal-design technique of the Nielsen arch bridge was proposed in this paper. The design parameters were the arch-rise ratio and the steel weight ratio of the Nielsen arch bridge, and optimal-design techniques were utilized to analyze the behavior of the bridge. The optimal parameter values were determined for the estimated optimal level. The parameter determination requires the standardization of the safety, utility, and economic concepts as the critical factors of a structure. For this, a genetic algorithm was used, whose global-optimal-solution search ability is superior to the optimization technique, and whose object function in the optimal design is the total weight of the structure. The constraints for the optimization were displacement, internal stress, and time and space. The structural analysis was a combination of the small displacement theory and the genetic algorithm, and the runtime was reduced for parallel processing. The optimal-design technique that was developed in this study was employed and deduced using the optimal arch-rise ratio, steel weight ratio, and optimal-design domain. The optimal-design technique was presented so it could be applied in the industry.

Differential diagnosis between odontogenic keratocyst and ameloblastoma by computed tomography (전산화단층사진을 이용한 치성각화낭과 법랑모세포종의 감별진단)

  • Eun Sang-A;Kim Kee-Deog;Park Chang-Seo
    • Imaging Science in Dentistry
    • /
    • v.32 no.2
    • /
    • pp.89-97
    • /
    • 2002
  • Purpose: The objective of this study is to find the differentiating characteristics of ameloblastomas and odontogenic keratocysts of the jaw by analyzing computed tomography (CT) images of the lesions, clarify radiological characteristics associated with jaw lesions, and to make a diagnsis based on these findings. Materials and Methods : Test subjects were chosen among the patients who were diagnosed as having an odontogenic keratocyst or ameloblastoma at the Yonsei University Dental Hospital from January 1996 to December 2000 and had CT scans taken preoperatively. The subject pool was comprised of 51 cases of odontogenic keratocyst and 37 cases of ameloblastoma. The following measures were used for image analysis of the lesion: the anatomic location, CT pattern, mesiodistal width, buccolingual width, the ratios between mesiodistal width and buccolingual width, height, CT number, homogeneity of radiodensity, the appearance of a sclerotic rim, continuity of adjacent cortical bone, and displacement and resorption of adjacent teeth. Results: Comparing the CT patten, mesiodistal width, buccolingual width, height, CT number, homogeneity, appearance of sclerotic rim, continuity of adjacent cortical bone, there were statistically significant differences between ameloblastoma and odontogenic keratocyst test subjects (p<0.05). Comparing the ratios between mesiodistal width and buccolingual width, displacement and resorption of adjacent teeth, there were no statistically significant differences (p>0.05). Conclusion: We compared odontogenic keratocysts and ameloblastomas in CT scans. They occurred most frequently in the posterior to the ramus of the mandible. The findings of patterns of the CT images showed that size and border of lesions were more aggressive in ameloblastomas than in odontogenic keratocysts. The internal contents represented an increased attenuation area (IAA) in odontopenic keratocyst. Odontogenic keratocysts were shown to have higher CT numbers than ameloblastomas.

  • PDF

EXPRESSION OF MATRIX METALLOPROTEINASE-1 AND -2 MRNA IN RETRODISCAL TISSUE OF THE TEMPOROMANDIBULAR JOINT (측두하악 관절원판 후조직의 MMP(matrix metalloproteinase)-1과 MMP-2 mRNA의 발현)

  • Huh, Jong-Ki;Park, Kwang-Kyun;Choi, Min-Ah;Kim, Hyung-Gon
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.29 no.4
    • /
    • pp.212-218
    • /
    • 2003
  • Matrix metalloproteinases (MMPs) play an important role in the normal morphogenesis, maintenance, and repair of matrix and also have important functions in pathologic conditions characterized by excessive degradation of extracellular matrix, such as rheumatoid arthritis, osteoarthritis, periodontitis and in tumor invasion and metastasis. In this study, expression of MMP-1 and -2 mRNA in retrodiscal tissue of the temporomandibular joint (TMJ) was examined and compared with magnetic resonance imaging (MRI) and surgical findings. MMP mRNAs in the retrodiscal tissue samples were detected by reverse transcription - polymerase chain reaction. TMJ internal derangement (ID) was categorized as normal disc position, disc displacement with reduction, early stage of disc displacement without reduction (DDsR) and late stage of DDsR. TMJ osteoarthrosis (OA) was classified with normal, mild and advanced OA. The amount of synovial fluid collection was divided into not detected, small, large and extremely large amount on MR T2-weighted imaging. Perforation and adhesion were examined during open surgery of the TMJ. Six out of 37 samples were excluded because of little amount of extracted total mRNA. MMP-2 mRNA was detected whole joints, and so the MMP-2 mRNA seems to be expressed normally in retrodiscal tissue. However, MMP-1 mRNA was expressed in 8 of 31 joints. Frequencies of MMP-1 mRNA expression according to the TMJ IDs, amount of synovial fluid and surgical findings made no significant difference. MMP-1 mRNA was detected more frequently in OA groups (7/16 joints, 43.8%) than in normal bony structure group (1/15 joints, 6.7%). Expression of MMP-1 mRNA in retrodiscal tissue might be related with OA of the TMJ.

The Short Term Outcome of Surgical Treatment for the Fifth Metatarsal Base Fracture Using a Headless Cannulated Compression Screw (제 5중족골 기저부 골절의 무두유관압박나사를 사용한 수술적 치료의 단기 추시 결과)

  • Chon, Je-Gyun;Choi, Hyun;Kim, Jun-Beom;Sun, Doo-Hun;Shin, Sang-Yeop
    • Journal of Korean Foot and Ankle Society
    • /
    • v.20 no.3
    • /
    • pp.131-134
    • /
    • 2016
  • Purpose: This study aimed to evaluate the outcomes, including the complications, of open reduction and internal fixation using a headless cannulated compression screw for a fifth metatarsal base fracture. Materials and Methods: We retrospectively investigated 11 patients with 5th metatarsal base fracture who were treated with a headless cannulated compression screw. The mean follow-up period was 13 months (8~15 months), and the mean age was 46.5 years (21~70 years). We analyzed the patients' sex, age, time to union, amount of fracture displacement, and complications. The American Orthopaedic Foot and Ankle Society (AOFAS) midfoot score was used for clinical assessment. Results: The average amount of displacement decreased significantly from 3.4 mm (2.1~5.2 mm), preoperatively, to 0.4 mm (0~1.3 mm), postoperatively (p<0.001). The average bone union time was 54.1 days (41~68 days). There were no complications, such as a metal failure, irritation, and loss of a reduction. The mean AOFAS midfoot score was 97.7 (90~100) at 6 months, postoperatively. Conclusion: We suggest that a headless cannulated compression screw for 5th metatarsal base fracture is a useful and alternative method for a firm fixation without complications.

Experimental Analysis on the Performance of a Solar Powered Water Pump (태양열 물펌프의 실험적 성능분석)

  • Kim Y. B.;Son J. G.;Lee S. K.;Kim S. T.;La W. J.;Lee Y. K.
    • Journal of Biosystems Engineering
    • /
    • v.29 no.6 s.107
    • /
    • pp.521-530
    • /
    • 2004
  • The solar powered water pump is very ideal equipment because solar power is more intensive when the water is more needed in summer and it is very helpful in the rural area, in which electrical power is not available. The average solar radiation power is $3.488\;kWh/(m^2{\cdot}day)$ in Korea. In this study, the experimental system of the water pump driven by the radiation energy were designed, assembled, tested and analyzed fur realizing the solar powered water pump. Energy conversion ken radiation energy to mechanical energy by using n-pentane as operating material was done and the water pumping cycles were able to be continued. The quantity of the water pumped per cycle ranged from 2 L to 10 L depending on the level of the valve open area far the vapour supply. The average quantity was about 4,366 cc. The thermal efficiency was about $0.018\%$. The pressure level of the n-pentane vapour in flash tank was about $110\~150\;kPa$ and that in the water tank was $93\~130\;kPa$. The pressure in the condenser during cycles was maintained as about 70 kPa. The condensation of the n-pentane vapour in the water tank was increased with the cycles even though the internal and external insulation were done. Air tank performance was better with increasing of the water piston displacement and the water could be pumped with the water piston displacement becoming higher than 6,500 cc.

Seismic Response Evaluation of Seismically Isolated Nuclear Power Plant Structure Subjected to Gyeong-Ju Earthquake (면진된 원자력발전소 구조물의 경주지진 응답평가)

  • Kim, Gwang-Jeon;Yang, Kwang-Kyu;Kim, Byeong-Su;Kim, Hyeon-Jeong;Yun, Su-Jeong;Song, Jong-Keol
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.20 no.7_spc
    • /
    • pp.453-460
    • /
    • 2016
  • The Gyeong-Ju earthquake in the magnitude of 5.8 on the Richter scaleoccurred in September 12, 2016. Because there are many nuclear power plants (NPP) near the epicenter of the Gyeong-Ju earthquake, the seismic stability of nuclear power plants is becoming a social problem. In order to evaluate the safety of seismically isolated NPP, the seismic response of a NPP subjected to the Gyeong-Ju earthquake was compared with those of 30 sets of artificial earthquakes corresponding to the nuclear standard design spectrum (NSDS). A 2-node model and a simple beam-stick model were used for the seismic analysis of seismically isolated NPP structures. Using 2-node model, the effect of internal temperature rise, decrease of shear stiffness, increase of lateral displacement and decrease of vertical stiffness according to nonlinear behavior of lead-rubber bearing (LRB) were evaluated. The displacement response, the acceleration response, and the shear force response of the seismically isolated nuclear containment structure were evaluated using the simple beam-stick model. It can be observed that the seismic responses of the isolated nuclear structure subjected to Gyeong-Ju earthquake is significantly less than those to the artificial earthquakes corresponding to NSDS.

Bending and free vibration analysis of laminated piezoelectric composite plates

  • Zhang, Pengchong;Qi, Chengzhi;Fang, Hongyuan;Sun, Xu
    • Structural Engineering and Mechanics
    • /
    • v.75 no.6
    • /
    • pp.747-769
    • /
    • 2020
  • This paper provides a semi-analytical approach to investigate the variations of 3D displacement components, electric potential, stresses, electric displacements and transverse vibration frequencies in laminated piezoelectric composite plates based on the scaled boundary finite element method (SBFEM) and the precise integration algorithm (PIA). The proposed approach can analyze the static and dynamic responses of multilayered piezoelectric plates with any number of laminae, various geometrical shapes, boundary conditions, thickness-to-length ratios and stacking sequences. Only a longitudinal surface of the plate is discretized into 2D elements, which helps to improve the computational efficiency. Comparing with plate theories and other numerical methods, only three displacement components and the electric potential are set as the basic unknown variables and can be represented analytically through the transverse direction. The whole derivation is built upon the three dimensional key equations of elasticity for the piezoelectric materials and no assumptions on the plate kinematics have been taken. By virtue of the equilibrium equations, the constitutive relations and the introduced set of scaled boundary coordinates, three-dimensional governing partial differential equations are converted into the second order ordinary differential matrix equation. Furthermore, aided by the introduced internal nodal force, a first order ordinary differential equation is obtained with its general solution in the form of a matrix exponent. To further improve the accuracy of the matrix exponent in the SBFEM, the PIA is employed to make sure any desired accuracy of the mechanical and electric variables. By virtue of the kinetic energy technique, the global mass matrix of the composite plates constituted by piezoelectric laminae is constructed for the first time based on the SBFEM. Finally, comparisons with the exact solutions and available results are made to confirm the accuracy and effectiveness of the developed methodology. What's more, the effect of boundary conditions, thickness-to-length ratios and stacking sequences of laminae on the distributions of natural frequencies, mechanical and electric fields in laminated piezoelectric composite plates is evaluated.

Optical Path Analysis for the Optical Encoder using Slit Internal Reflection (슬릿 내부 반사를 이용한 광학식 인코더의 광경로 해석)

  • Kweon, Yong-Min;Kweon, Hyun-Kyu;Park, Chang-Yong
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.16 no.5
    • /
    • pp.69-77
    • /
    • 2017
  • This paper introduces an optical encoder using the reflection in the slit. The digital optical encoder is a sensor to generate a pulse according to the displacement. An optical encoder is composed of 3 parts: light source, slit plate and light-receiving element. In a conventional encoder, one slit produces one signal. The resolution of the digital optical encoder is determined by the number of slits in the encoder plate. The small slit size is most important among the factors that determine the resolution in a generic-type optical encoder. However, a small slit has low productivity and technical difficulties, so analog optical encoders have emerged as an alternative. Nonetheless, this alternative requires additional circuitry and equipment because of the noise and drafts in the analog signals. A new sensor is presented in this paper with a high resolution and a slit of the same size using the reflection in the slit. Then, the path of the light that passes through the slit ccording to the shape was analyzed, and some paths were expressed in the mathematical expressions. In addition, the optical paths were analyzed in the rectangular, octagonal, and circular encoders, and shown the obtained number of signals per slit by using them. Thus, we confirm that this method has the best performance in circle-shaped slits.