• Title/Summary/Keyword: Internal displacement

Search Result 543, Processing Time 0.023 seconds

Changes in Medial Knee Displacement and Lower Extremity Kinematics in Subjects with Dynamic Knee Valgus Following Application of Non-elastic Tape to the Hip Joint while Performing an Overhead Squat (오버헤드 스쿼트를 실시하는 동안 비탄력 테이핑의 엉덩관절 적용에 따른 동적 무릎 밖굽이가 있는 대상자의 무릎 내측 전위와 하지의 운동형상학의 변화)

  • Go-eun Choi;Jong-chul Jung;Dong-yun Bae;Won-young Park;Da-in An;Young-il Shin;Sung-hwa Go;Jun-seok Kim;Soo-Yong Kim
    • PNF and Movement
    • /
    • v.21 no.3
    • /
    • pp.337-344
    • /
    • 2023
  • Purpose: The purpose of this study was to evaluate changes in the lower extremity kinematics of subjects with dynamic knee valgus after we applied non-elastic tape while they performed overhead squat. Methods: Twenty-five subjects (12 females, 13 males) with dynamic knee valgus participated in this study. Hip and knee joint kinematics and medial knee displacement were measured during overhead squat with and without hip correction taping. Results: Hip joint internal rotation, knee valgus, and medial knee displacement were significantly lower during overhead squat with hip correction taping than without hip correction taping, but there was no significant difference in hip joint flexion and abduction. Conclusion: Hip joint correction using non-elastic taping is recommended to subjects with dynamic knee valgus to improve their lower extremity movement and alignment during overhead squat.

Multi-dimentional Correction of the Scarf Osteotomy for the Treatment of Hallux Valgus (무지 외반증에 시행한 Scarf 절골술의 3차원적 변형 교정력에 관한 연구)

  • Moon, Gi-Hyuk;Ahn, Gil-Yeong;Yun, Ho-Hyun;Lee, Yeong-Hyun;Lee, Jung-Ick;Nam, Il-Hyun
    • Journal of Korean Foot and Ankle Society
    • /
    • v.11 no.1
    • /
    • pp.23-27
    • /
    • 2007
  • Purpose: Scarf osteotomy can provide the simultaneous correction of the hallux valgus angle (HVA), 1-2 intermetatarsal angle ($IMA_{1-2}$), DMAA and the plantar displacement of the fragment. The study was conducted to understand the multi-dimensional correction of the hallux valgus. Materials and Methods: Fourty eight patients who had undergone Scarf osteotomy with hallux valgus at more than $30^{\circ}$ of HVA and more than $15^{\circ}$ of $IMA_{1-2}$ were studied. Before an osteotomy, a reference K-wire was inserted to the 1st metatarsal head. After the osteotomy, the plantar fragment was moved laterally and the proximal end of the fragment was forced beyond the distal end which resulted in an internal rotation of the head fragment to correct the DMAA. Results: The HVA improved an average of $33.3^{\circ}$ to $7.7^{\circ}$ with the IMA1-2 respectively from $15.4^{\circ}$ to $6.5^{\circ}$. The DMAA improved an average of $19.5^{\circ}$ ($5.2-30.9^{\circ}$) to $4.5^{\circ}$ ($0.4-13.8^{\circ}$). By checking the angle, which was at an average of $25^{\circ}$ between the plantar surface of the foot and the osteotomy plane, the average distance of 1.9 mm (1.18-3.1 mm) of plantar displacement was measured using the value of sine (sin 25 = 0.422). Conclusions: It is possible to correct the HVA, IMA1-2 and DMAA simultaneously with one osteotomy making the lateral shift, the internal rotation and the plantar displacement of the plantar head fragment as desired. Despite the technicality and difficulty of the Scarf osteotomy, once familiarized through myriad procedures, all disadvantages are outweighed by the success and satisfaction of both patient and surgeon.

  • PDF

Using a Kirschner wire as an internal splint at nasal fractures accompanied fracture of frontal process of maxilla or perpendicular plate of ethmoid (상악골 전두돌기 골절 및 사골 수직판 골절을 동반한 비골 골절에서 K 강선을 이용한 내고정)

  • Rho, Kyoung Hwan;Yoon, Eul Sik;Yoon, Byung Min;Dhong, Eun Sang
    • Archives of Plastic Surgery
    • /
    • v.36 no.5
    • /
    • pp.623-628
    • /
    • 2009
  • Purpose: In cases where nasal fractures involve frontal process of maxilla or perpendicular plate of ethmoid, 4 - 5 days of nasal packing may not provide sufficient support for avoiding displacement after packing removal. Therefore a single Kirschner - wire(K - wire) is used as an internal splint when nasal fractures involve the above two areas. Methods: Thirty five patients during the last 3 practical years were treated with a K -wire pinning according to the anatomic locations of nasal fractures. We performed a retrospective study using 13 nasal fractures out of total 35 patients. Among 13 cases, 10 patients involved frontal process of maxilla, and 3 patients were diagnosed as bilateral nasal side wall fractures accompanied with fractures of perpendicular plate of ethmoid. One patient of the last three cases had been augmented with dorsal silicone implant long before the trauma. We analyzed the anteroposterior displacement of key stone area and the width between both lateral walls by comparing immediate postoperative radiographs with 2 month follow - ups. To reduce the errors, the same measurements were taken by two different inspectors, and the mean of each inspector's measurements was compared. Patient satisfaction was analyzed using a questionnaire regarding the esthetic and functional outcomes. Results: Ten patients underwent a longitudinal K - wire fixation in submucoperiosteal plane underneath the frontal process of maxilla. And three patients underwent a transverse K - wire fixation from the one side of lateral wall to the perpendicular plate of ethmoid and to the other side of lateral wall. The mean postoperative anteroposterior displacement of the key stone area measured by two inspectors were 1.84% and 3.06%; mean narrowing of bony pyramid were 1.33% and 1.48%, respectively. Subjective satisfaction scores regarding the esthetic appearance and the maintenance of nasal shape compared with immediate post - operative state with the long term ones were not different (p>0.05). Conclusion: K - wire pinning after closed reduction is a reliable and useful method for the treatment of nasal fractures involving frontal process of maxilla or perpendicular plate of ethmoid. This is because it achieves longer intranasal support after reduction. This method also leaves conspicuous external scar, and minimal soft - tissue injury.

Reconstruction of internal structures and numerical simulation for concrete composites at mesoscale

  • Du, Chengbin;Jiang, Shouyan;Qin, Wu;Xu, Hairong;Lei, Dong
    • Computers and Concrete
    • /
    • v.10 no.2
    • /
    • pp.135-147
    • /
    • 2012
  • At mesoscale, concrete is considered as a three-phase composite material consisting of the aggregate particles, the cement matrix and the interfacial transition zone (ITZ). The reconstruction of the internal structures for concrete composites requires the identification of the boundary of the aggregate particles and the cement matrix using digital imaging technology followed by post-processing through MATLAB. A parameter study covers the subsection transformation, median filter, and open and close operation of the digital image sample to obtain the optimal parameter for performing the image processing technology. The subsection transformation is performed using a grey histogram of the digital image samples with a threshold value of [120, 210] followed by median filtering with a $16{\times}16$ square module based on the dimensions of the aggregate particles and their internal impurity. We then select a "disk" tectonic structure with a specific radius, which performs open and close operations on the images. The edges of the aggregate particles (similar to the original digital images) are obtained using the canny edge detection method. The finite element model at mesoscale can be established using the proposed image processing technology. The location of the crack determined through the numerical method is identical to the experimental result, and the load-displacement curve determined through the numerical method is in close agreement with the experimental results. Comparisons of the numerical and experimental results show that the proposed image processing technology is highly effective in reconstructing the internal structures of concrete composites.

Combined Percutaneous and Minimal on Internal Fixation of Calcaneal Fractures Using Extensile Lateral Approach (광범위 외측 도달법을 이용한 종골 골절의 경피적 및 최소 내고정술)

  • Yu, Sun-O;Kim, Joo-Sung;Kim, Jong-Jin
    • Journal of Korean Foot and Ankle Society
    • /
    • v.6 no.2
    • /
    • pp.201-207
    • /
    • 2002
  • Purpose: To present the clinical analysis of the results obtained in 38 cases of displaced intraarticular calcaneal fractures undergone combined percutaneous axial pin fixation of calcaneal body and minimal internal fixation using extensile lateral approach. Materials and Methods: From March 2000 to February 2002, thirty-eight displaced intraarticular fractures of the calcaneus in 35 patients were fixed with 3.5mm cannulated screws and percutaneous 2.5mm K-wires. The extensile lateral approach was used in all cases. The average follow-up period was 16 months. Clinical evaluation was assessed according to the Ankle-Hind Foot Scale of American Orthopedic Foot and Ankle Society. Results: The clinical results were graded as excellent in 8 cases(21%), good in 22 cases(58%), fair in 6 cases(16%), and poor in 2 cases(5%). Two cases of poor result were type IV of Sanders classification. The postoperative reduction status of the articular surface was analyzed by computed tomography in all cases and was found to be less 2mm of step off in 30 cases and between 2 and 4mm in 8 cases. Unsatisfactory results were correlated with severity of articular comminution and failure to obtain accurate reduction of the articular surface. Using early functional postoperative care, all fractures healed without secondary displacement except 1 case on an average of ten weeks. Two cases had superficial necrosis of the wound margins, however, secondary wound healing was uneventful and skin grafting was not needed. Conclusion: Combined minimal internal fixation and percutaneous pin fixation using extensile lateral approach is useful operative method of intraarticular calcaneal fractures because providing enough stability to permit functional aftercare and allowing excellent anatomical reduction. In addition, this method diminishes the risk of lateral soft tissue problems.

  • PDF

A Study on the Characteristics of Shear Strength in Unsaturated Cohesive Soils (불포화 점성토의 전단강도 특성에 관한 연구)

  • 유범식;조덕현
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.23 no.3
    • /
    • pp.96-104
    • /
    • 1981
  • In order to investigate the characteristics of the shear strength of the unsaturated cohesive soils which has mean characters of sand and clay widely used for banking, I selected soil samples from An-sung district and, against it, performed direct shear test and unconfined compression test changing grain size, compaction energy and moisture content and also performed triaxial compression test under optimum moisture content. The results are as follows; 1.As the passing percent of the No. 200 sieve increased from 23.6% to 56.1%, cohesion increased from 0. 202kg/cm2 to 0. 398kg/cm2 under the direct shear test and from 0.38 kg/cm2 to 1. 05kg/cm2 under the tria4al compression test, internal friction angle decreased from 44. 78$^{\circ}$ to 34. 34$^{\circ}$ under the direct shear test and from 31. 88$^{\circ}$ to 13. 31$^{\circ}$ under the triaxial compression test. 2.Cohesion showed it's maximum value around OMC and internal friction angle showed a tendency to increase according to the decrease of water content but it's increasing ratio was relatively slow. 3.Decreasing ratio of cohesion and internal friction angle was relatively sensitive according to the decrease of compaction energy. 4.The smaller of the vertical stress and the coarser of the grain size of samples, changing of the volume showed a tendency to increase and as the increase of water content, the shear displacement (dh) at failure shear stress ($\tau$f) showed maximum and the $\tau$f-dh curve was gentle. 5.To synthesize the results of the direct shear test and the triaxial compression test, cohesion showed higher under the triaxial compression test and internal friction angle showed a tendeney to appear higher under the direct shear test. It seems that we can get correspondent results by removing the side friction of mold with soils and adjusting the vertical stress and shearing speed under the direct shear test.

  • PDF

Analysis of Internal Pressure Capacity of Modular Containment Structure for Small Modular Reactor (소형 원자로용 모듈화 격납구조의 내압성능 분석)

  • Park, Woo-Ryong;Yhim, Sung-Soon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.8
    • /
    • pp.362-370
    • /
    • 2019
  • The internal pressure capacity of a modular containment structure requires analysis to prevent the release of radioactive material in the case of an accident. To analyze the capacity, FEM models were prepared while considering the tendon arrangements and the contact surfaces between precast concrete modules, and then static analyses were carried out. The changing characteristics in the displacement and stress under step-wise loading were analyzed, along with the effects of selected parameters. For comparison, the capacity of a monolithic containment structure was also analyzed. Parametric analyses were done to suggest ranges of parameters such as the tendon force, tendon spacing, tendon location in concrete thickness direction, friction coefficient, and concrete thickness. The tendon force and frictional force provide a combined effect between contact surfaces of modules. The same level of internal pressure capacity can be secured even in the modular containment structure as in the monolithic containment structure by increasing the tendon force with additional tendons.

Packaging Design of EPS Cooling Box by Theoretical Heat Flow and Random Vibration Analysis (이론적 열유동 및 랜덤 진동 해석을 적용한 EPS 보냉용기의 포장설계)

  • Kim, Su-Hyun;Park Sang-Hoon;Lee, Min-A;Jung, Hyun-Mo
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.27 no.3
    • /
    • pp.175-180
    • /
    • 2021
  • Although it has recently been regulated for use as an eco-friendly policy in Korea, the use of EPS (Expanded Polystyrene) cooling boxes, which are used as cold chain delivery insulation boxes for fresh agricultural and livestock products, is also increasing rapidly as e-commerce logistics such as delivery have increased rapidly due to COVID-19. Studies were conducted to optimize the EPS cooling container through internal air heat flow of CFD (Computational Fluid Dynamics) analysis and FEM (Finite Element Method) random vibration analysis using domestic PSD (Power Spectral Density) profile of the EPS cooling box to which the refrigerant is applied in this study. In the analysis of the internal air heat flow by the refrigerant in the EPS cooling box, the application of vertical protrusions inside was excellent in volume heat flow and internal air temperature distribution. In addition, as a result of random vibration analysis, the internal vertical protrusion gives the rigid effect of the cooling box, so that displacement and stress generation due to vibration during transport are smaller than that of a general cooling container without protrusion. By utilizing the resonance point (frequency) of the EPS cooling box derived by the Model analysis of ANSYS Software, it can be applied to the insulation and cushion packaging design of the EPS product line, which is widely used as insulation and cushion materials.

Collapse-resistant performance of a single-story frame assembly and multi-story sub-frame under an internal column-removal scenario

  • Zhong, Wei-hui;Tan, Zheng;Tian, Li-min;Meng, Bao;Zheng, Yu-hui;Daun, Shi-chao
    • Steel and Composite Structures
    • /
    • v.41 no.5
    • /
    • pp.663-679
    • /
    • 2021
  • To elucidate the differences in the collapse behavior between a single-story beam-column assembly and multi-story frame, two 1/3-scale two-bay composite frames, including a single-story composite beam-column assembly and a three-story composite sub-frame, were designed and quasi-statically tested. The load-displacement responses, failure modes, and internal force development of the two frames were analyzed and compared in detail. Furthermore, the resistance mechanisms of the two specimens were explored, and the respective contributions of different load-resisting mechanisms to the total resistances were quantitatively separated to gain deeper insights. The experimental tests indicated that Vierendeel action was present in the two-dimensional multi-story frames, which led to an uneven internal force distribution among the three stories. The collapse resistance of TSDWA-3S in the flexural stage was not significantly increased by the structural redundancy provided by the additional story, as compared to that of TSDWA-1S. Although the development of the load response was similar in the two specimens at flexural stage, the collapse mechanisms of the multi-story composite frame were much more complicated than those of the single-story beam-column assembly, and the combined action between stories was critical in determining the internal force redistribution and rebalancing of the remaining structure.

Successful Management of Post-Traumatic Hydrocephalus and Pseudomeningocele Following Traumatic Brain Injury in a Cat

  • Hyoung-Won Seo;Jeong-Min Lee;Hae-Boem Lee;Yoon-Ho Roh;Tae-Sung Hwang;Kun-Ho Song;Joong-Hyun Song
    • Journal of Veterinary Clinics
    • /
    • v.40 no.1
    • /
    • pp.56-61
    • /
    • 2023
  • A 5-month-old female domestic short-haired cat presented with a history of seizure episodes for two months following an animal bite injury to the head. There were no remarkable findings on physical and neurological examination or blood analysis. Computed tomography revealed a fracture of the left parietal bone with an inward displacement of the bone fragment while magnetic resonance imaging revealed an enlarged temporal horn of the left lateral ventricle and a pseudomeningocele compressing the adjacent cerebral parenchyma. Subsequently, cerebrospinal fluid analysis results were normal. The patient was diagnosed with traumatic brain injury (TBI), with subsequent post-traumatic hydrocephalus (PTH) and pseudomeningocele. Despite treatment with phenobarbital and levetiracetam, seizures were not sufficiently controlled. Craniectomy for bone fragment removal and duraplasty were performed after a week. The patient then returned to normal condition with no further seizure activity. On repeated MRI two months after discharge, the hydrocephalus of the lateral ventricle and pseudomeningocele were enlarged; however, the patient maintained a good clinical status without any neurological signs. To the best of our knowledge, PTH and intracranial pseudomeningoceles have not yet been reported in cats. PTH and pseudomeningocele are among the complications of TBI and may not have any significant relevance with the clinical signs in this case. Thus, to broaden our knowledge about PTH and pseudomeningocele in cats, we describe serial changes in the clinical findings of this cat over the treatment period.