• Title/Summary/Keyword: Internal discharge

Search Result 642, Processing Time 0.026 seconds

전류변화에 따른 Over Cut에 관한 실험적 연구

  • 신근하
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1996.10a
    • /
    • pp.58-63
    • /
    • 1996
  • A study is drawn up its result's tables and graphs by measuring tools(outside micrometer cylinder gauge and dial caliper gauge) on the difference of diameter volumes from before-discharge and after-discharge under 52 Kind's experimental condition by cupper and graphite electrode of CNC EDM. The EDM is attached with A.V.R. and memory scope for keep up accuracy and the fixed table of work piece is used in order to eliminate the noise by the internal resistance of it and forcing to eradicate the discharge liquid. It is analyzed cutting conditions to compare its wave value and pulse time.(Ton Toff) through voltage and current for decreasing working error.

  • PDF

CAPACITY ANALYSIS OF THE SILVER OXIDE-ZINC CELL (PHASE 1)

  • 이완구
    • Journal of the Korean Professional Engineers Association
    • /
    • v.14 no.4
    • /
    • pp.15-25
    • /
    • 1981
  • Electrical behaviors of the divalent silver oxide-zinc cell were analyzed for imporving capacity and keeping electrodes from passivation or sharp increases of cell internal resistance in the course of discharge. One of primary factors in relation to lowering performance can be depicted by cell internal resistance increase being created by various routes, first by insufficiency and/or the carbonation of the electrolyte, secondly by barrier blockage, thirdly by electrode passivation which are due to improper material use of wrong processing, and by gassing as fourth cause. The carbonation causes electrobyte to have impedance up as well as poor amalgamation, resulting in vigorous corrosion reaction of copper plated inner top, evolving hydrogen gas. Electrical characteristics of the cell was reviewed to elucidate relationships between the discharge capacity and the cell internal resistance.

  • PDF

Unbalance load current of Operating in Parallel of Lead acid batteries connection condition (납 축전지 병렬운전시 발생하는 전류 불평형 현상분석 및 대책)

  • 반한식;곽철훈;최규하;목형수
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.210-213
    • /
    • 1999
  • A battery is the device that transforms the chemical energy into the direct-current electrical energy directly without a mechanical process. Unit cells are connected in series to obtain the necessary voltage, while being connected in parallel to organize capacity for load current and to decrease the internal resistance for corresponding the sudden shift of the load current. The circular-current, however, could be occurred when the system is driven in parallel. As a result, the new batteries are heated by over-change and discharge, and the over charge current makes to increase the rust of the positive grid and consequently the shortened life of the new batteris would be shown. In this paper, the internal resistance of charge and discharge will be balanced, through inserting the resistance into the system by way of calculation of the changed amount of internal resistance.

  • PDF

A Study on Structural Improvement of the Swashplate Axial Piston Pump Valve Block (2) (사판 식 축 피스톤 펌프 밸브블록의 구조개선에 관한 연구(2))

  • Kim, Jeong-Hwa;Shin, Mi-Jung;Kim, Myung-Kyu
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.17 no.1
    • /
    • pp.76-81
    • /
    • 2018
  • This study aims to provide ways to achieve structural improvements of the internal flow path of the discharge plenum of a swash plate piston pump valve block vulnerable to cracks. This paper corresponds to Part II, which consists of a structural interpretation of the internal flow path of the discharge plenum of the valve block. The simple model result reviewed in Part I was incorporated into the valve block model and five different design changes were reviewed as part of the study on the structural improvement of the internal flow path of the valve block.

A development of intelligent spacer built in the Internal type UHF partial discharge sensor (초고주파 광대역 부분방전 센서를 내장한 지능형 스페이서 개발)

  • Kim, Dong-Suk;Hwang, Chul-Min;Kim, Young-Noh;Choi, Jae-Ok;Seo, Wang-Byuk;Han, Bong-Soo;Choi, Soo-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2007.11a
    • /
    • pp.163-164
    • /
    • 2007
  • In this study, we developed intelligent spacer built in the internal type UHF PD sensors. 3-Dimensional electro-magnetic simulations were performed to analyze electric-field distribution of the single-phase GIS and three-phase GIS. After considering the spacer's specification, Sensor structures were designed and analyzed using the 3-D EM Simulator. As a result of the simulation the internal type UHF PD sensors were built in. Performance of the sensor built into real scale GIS spacer was measured in terms of return loss and detected Max voltage. And we identified a character of the intelligent spacer by using 5pC partial discharge ceil.

  • PDF

Properties of On-Line Partial Discharge in Hydrogenerator Stator Windings (수력발전기 고정자 권선의 운전중 부분방전 특성)

  • Kim, Byong-Han;Kim, Hee-Dong
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.4
    • /
    • pp.172-177
    • /
    • 2006
  • During normal machine operation, partial discharge(PD) tests were performed with partial discharge analyzer(PDA) in two hydrogenerators. Six cable couplers were installed in circuit ring bus and endwinding of three phases. PDA showed that the normalized quantity number(NQN) and the partial discharge magnitude$(Q_m)$ were very low in hydrogenerator #1 and #2, respectively. The trend analyses of NQN and $Q_m$ value are available for monitoring of the insulation condition in hydrogenerator stator windings. The insulation condition of stator winding can be assessed. Discharge at conductor surface was discovered in B phase(C2 coupler) of hydrogenerator #1. Internal discharges were generated in A and C phases(C2 coupler) of hydrogenerator #1 and in A, Band C phases(C1 and C2 couplers) of hydrogenerator #2. Slot discharges occurred in A, Band C phases(C1 coupler) of hydrogenerator #1. The stator windings of two hydrogenerators were in good condition.

Discharge and Ozone Characteristics of Multi Discharge Type Ozonizer (다중방전형 오존발생기의 방전 및 오존생성특성)

  • Chun, Byung-Joon;Mun, Kyung-Su;Song, Hyun-Gik;Kim, Keum-Yeung;Lee, Kwang-Sik
    • Proceedings of the KIEE Conference
    • /
    • 1999.11d
    • /
    • pp.1090-1092
    • /
    • 1999
  • In this paper, multi discharge type ozonizer has been designed and manufactured. The of ozonizer is equipped with three electrodes(central electrode of screw shape, internal electrode and external electrode). This paper describes the following two characteristics: (1) The characteristics of discharge with variation of output voltage of AC H.V source, flow rate of oxygen supplied gas and discharge voltage. (2) The characteristics of ozone generation by varying flow rate and discharge power.

  • PDF

Characteristics of a Superposed Discharge Type Ozonizer(III) (중첩방전형 오존방생기의 특성(III))

  • Song, Hyun-Jig;Lee, Kwang-Sik;Lee, Dong-In;Kim, Gi-Chae;Lee, Dong-Heon;Kim, Geum-Young;Lee, Chun-Ha;Jeun, Young-Ju
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1815-1817
    • /
    • 1998
  • In this paper, a superposed discharge type ozonizer(IESDO) has been designed and manufactured. IESDO is equipped with three electrodes(central, internal and external electrodes), and it is composed of two gaps. Ozone is generated by overlapping silent discharge, which is respectively came from two gaps. This paper describes the following characteristics : (1) The characteristics of discharge with variation of output voltage of AC H.V source, quantity of supplied gas and discharge voltage (2) the characteristics of ozone generation with variation of quantity of supplied gas, discharge power, operating number of IESDO.

  • PDF

Partial Discharge Properties of High Voltage Motor Stator Insulation using Partial Discharge Analyzer (PDA를 이용한 고압전동기 고정자 권선에서 부분방전 특성)

  • Kim, Hee-Dong;Lee, Sang-Kil
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.05c
    • /
    • pp.225-228
    • /
    • 2001
  • Partial discharge(PD) testing for different capacitive couplers was performed on a 6.6kV, 448kW pulverizer motor. The motor has been in service for twenty years. PD tests were measured using digital partial discharge detector(DPDD) and partial discharge analyzer(PDA), respectively. PDA is used to in the motor stator insulation, which three 80pF or three 500pF epoxy-mica couplers were installed, one per phase. The 500pF couplers did detect more normalized quantity number(NQN) than the 80pF couplers. DPDD and PDA showed that PD and NQN magnitudes increased with increase of ac voltage. Internal discharge was discovered in the motor stator insulation. DPDD and PDA test results are in accordance with the pattern and magnitude of PD.

  • PDF

Feature Extraction of Partial Discharge for Stator Winding of High Voltage Motor (고압전동기 고정자권선의 부분방전 특징추출)

  • Park, Jae-Jun;Kim, Hee-Dong;Lee, Dong-Yoon
    • Proceedings of the KIEE Conference
    • /
    • 2004.11a
    • /
    • pp.112-116
    • /
    • 2004
  • On-line monitoring of fault discharge is an important approach for indicating the condition of electrical insulation of stator winding in high voltage motor. In this paper, several key aspects of on-line monitoring system are discussed, involving the characteristics of fault discharge of stator winding in high voltage motor, spectrum analysis of four simulation fault signals, feature extraction of internal fault discharge from apply voltage to breakdown. The study of the partial discharge activities allows to highlight the ageing stage in the winding fault under test. During the life of the winding insulation fault, the shape of PD signal change relating to the ageing stage. The ageing of stator winding insulation fault of high voltage motor is investigated based on the characteristics of partial discharge pulse distribution and statistical parameters, such as maximum, skewness and kurtosis using discrete wavelet transform coefficients.

  • PDF