• Title/Summary/Keyword: Internal discharge

Search Result 642, Processing Time 0.031 seconds

Applied Sound Frequency Monitoring in the Transformer Oil Using Fiber Optic Sagnac Interferometer (사냑형 간섭계 광섬유 센서를 이용한 변압기유 내에서의 외부 음향 주파수 모니터링)

  • Lee, Jongkil;Lee, Seunghong
    • The Journal of the Acoustical Society of Korea
    • /
    • v.34 no.4
    • /
    • pp.288-294
    • /
    • 2015
  • The fiber optic Sagnac interferometer is well established as a sensor for detection of physical perturbations such as acoustic and vibration. In this paper acoustic signals generated in the cylindrical cavity submerged in transformer oil were measured by the fiber optic sensor array in one Sagnac loop. Two different external sound frequencies, $f_1$ and $f_2$, were applied to the sensor array simultaneously by using piezoelectric with frequency range from 5 kHz to 90 kHz. Based on the experimental results, fiber optic sensor detected harmonic series of applied sound frequency such as $f_1$, $f_2$, $2f_1$, $2f_2$, ${\mid}f_1-f_2{\mid}$, ${\mid}f_1+f_2{\mid}$. Suggested fiber optic sensor array can be applied to monitor physical quantities such as internal sound pressure and vibration due to partial discharge in the real electric transformer system.

Performance of R430A on Refrigeration System of Domestic Water Purifiers (대체냉매 R430A를 적용한 정수기 냉동시스템의 성능 평가)

  • Park, Ki-Jung;Lee, Yo-Han;Jung, Dong-Soo;Kim, Kyoung-Kee
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.2
    • /
    • pp.109-117
    • /
    • 2009
  • In this study, thermodynamic performance of R430A is examined both numerically and experimentally in an effort to replace HFC134a used in the refrigeration system of domestic water purifiers. Even though HFC134a is used predominantly in such a system these days, it needs to be phased out in the near future in Europe and most of the developed countries due to its high global warming potential. To solve this problem, cycle simulation and experimental measurements are carried out with a new refrigerant mixture of 76%R152a124% R600a using actual domestic water purifiers. This mixture is numbered and listed as R430A by ASHRAE recently. Test results show that the system performance with R430A is greatly influenced by the amount of charge due to the small internal volume of the refrigeration system of the domestic water purifiers. With the optimum amount of charge of 21 to 22 grams, about 50% of HFC134a, the energy consumption of R430A is 13.4% lower than that of HFC 134a. The compressor dome and discharge temperatures and condenser center temperature of R430A are very similar to those of HFC134a at the optimum charge. Overall, R430A, a new long term environmentally safe refrigerant, is a good alternative for HFC134a requiring little change in the refrigeration system of the domestic water purifiers.

Clinical Studies on 5 Cases of Acute Viral Hepatitis A Treated by Oriental Medicine (급성 바이러스성 A형 간염의 한방치료 5례에 관한 임상보고)

  • Ie, Jae-Eun;Heo, Su-Jung;Kim, Hyun-Jin;Cho, Hyun-Ju;Kim, Hyuck
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.23 no.6
    • /
    • pp.1480-1485
    • /
    • 2009
  • We conducted this study to report the clinical manifestations of 5 acute viral hepatitis type A treated by oriental medical treatment. Five hepatitis A patients who visited OO oriental hospital from May 2008 to July 2009 were treated by oriental medical treatment, including herbal acupuncture, acupuncture and herbal medicine and western medical treatment, including fluid therapy and peroral medicine. Prodromes were similar to influenza and duration from symptom onset to first visit were $5.0\;{\pm}\;1.6$ days. Chief symptoms included jaundice, itching, dark urine, anorexia, fatigue, nausea, vomiting, abdominal discomfort. The mean values of the initial laboratory test were serum total bilirubin(TB) of $3.62\;{\pm}\;2.77\;mg/dL$, aspartate aminotransferase(AST) of $729\;{\pm}\;422\;IU/L$, alanine aminotransferase(ALT) $774\;{\pm}\;754\;IU/L$. The peak mean values of those were $6.30\;{\pm}\;2.13\;mg/dL$, $2177\;{\pm}\;2573\;IU/L$, $2238\;{\pm}\;1682\;IU/L$ respectively. The mean duration of hospitalization were $15\;{\pm}\;3$ days. Follow-up at 3 weeks after discharge showed that all patients recovered without complications. Treatment of oriental medicine has effectiveness on acute viral hepatitis type A. Further study is needed.

Unusual Tc-99m MDP Uptake in the Keloid Developed after Subtotal Gastrectomy

  • Lim, Seok-Tae;Park, Soon-Ah;Sohn, Myung-Hee;Yim, Chang-Yeol
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.5
    • /
    • pp.436-437
    • /
    • 2000
  • A 63-year-old male who had subtotal gastrectomy for early gastric cancer three months ago underwent Tc-99m bone scintigraphy for the evaluation of skeletal metastases. He had no symptoms such as fever, tenderness, or wound discharge. On physical examination, the surgical scat along the midline of the upper abdomen had keloid formation and there was no radiographic evidence of calcification. Bone scintigraphy (Fig. 1A & 1B) demonstrated all unusual linear increased uptake along the midline of the upper abdomen that corresponded to the,skin incision for subtotal gastrectomy. Usually, an incisional scar will not be visualized in Tc-99m methylene diphosphate (MDP) scintigraphy beyond two weeks after surgery.$^{1)}$ Upon reviewing the literature, there were only a few reports where localization of Tc-99m MDP in surgical scars were found two months after surgery.$^{2)}$ It was also reported that a few cases with Tc-99m MDP uptake in the keloid scar developed after surgery. Although there are several potential mechanisms that may explain the uptake of Tc-99m MDP in scar tissue, the primary mechanism in older scars is suggested to be a result of pathological calcification.$^{2)}$ Siddiqui et al$^{3)}$ suggested it could be due to microscopic calcification in small resolving hematomas. However, the primary mechanism in keloid scar is not well-known. We should obtain oblique or lateral views to differentiate the uptake in healing surgical scars from the artifactual uptake.

  • PDF

Degradation Diagnosis of Complex System Using Regression Analysis (회귀분석을 이용한 복합 시스템의 열화진단)

  • 김성홍;박재준;김재환
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.1
    • /
    • pp.39-45
    • /
    • 1999
  • Because of internal voids in insulators give rise to partial discharge(PD), which cause local breakdown and even entire insulation breakdown. Treeing due to PD is one of the main causes of breakdown of the insulating materials and nrluction of the insulation life. 1berefore the necessity for establishing a rrethod to diagnose the aging of insulation materials and to predict the breakdown of insulation has becorne irrportant. From this viewpoint, our studies diagnose insulation degradation using the rrethod of computer sensing system, which has PD and acoustic emission(AE) sensing system. To use advantages of these two methods can be used effectiveiy to search for treeing location and PD in sorre materials. In analysis rrethod of degradation, we analyzed the PD and AE pulses by regression analysis, corrpared to these obtained the correlation coefficient and retermination coefficient by T-distribution and saw that PD and AE pulses show a similar pattern on the whole. This has a similar teIlrency to the results of the research by Yoshimura and Fujita.Fujita.

  • PDF

Multi-Junction Space Solar Cell Health Checking Method using Electroluminescence Phenomena (전계발광현상을 이용한 우주용 다접합 태양전지의 건전성 평가기법)

  • Park, Je-Hong;Chang, Young-Keun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.37 no.10
    • /
    • pp.1017-1026
    • /
    • 2009
  • The solar cell system operates by facing the sun-light. Minor cracks, static discharge, and thermal shock that can happen during production/testing phase can lead to degradation in performance during operation, since solar cells are exposed to extreme thermal/mechanical environment in space. In order to detect small cracks and internal damages in the solar cells due to thermal shocks, which are the core units of a solar cell system, expensive equipment, complicated test process, and much time are required. Therefore, a qualitative method for easily and quickly testing the 'health' of solar cell functionality is required. This dissertation describes a theoretical and technical grounds for quickly and easily evaluating the health of solar cells using electroluminescence effect of Gallium-Arsenide solar cells that are most widely used by spacecrafts in recent years. Also described in the dissertation is the technical issues and constraining factors for applying the proposed method to actual space-rated solar cell systems.

The prophylactic uses of antibiotics for the prevention of surgical site infection and the effects: The 3-year experience in a tertiary hospital (수술 예방적 항생제의 사용 현황 및 관리전후 효과)

  • Yang, Jiyeon;Kim, Moon-Sook;Kim, Yu-Jeong;Lee, Eun-Bong
    • Quality Improvement in Health Care
    • /
    • v.18 no.1
    • /
    • pp.71-78
    • /
    • 2012
  • Background : The objective of this study was to examine the effect of management system for the appropriate prophylactic use of antibiotics in surgical patients at a tertiary hospital from 2007 to 2010. Methods : We collected clinical data of three different surgical procedures(colectomy, heart surgery, hysterectomy) for three months of 2007 and 2010, respectively. The number of total cases was 245(137, 54, 54) in 2007, 240(133, 42, 65) in 2010. We measured the rate of use of inappropriate prophylactic antibiotics, administration within 1 hour prior to the incision and the antibiotics prescription days after surgery. To evaluate the effectiveness of the management system, the results of the two groups(Group1=2007, Group2=2010) were compared by t-test, chi-square test or Fisher's exact test. Result : The rate of Aminoglycoside uses decreased drastically from 11.4% to 0.8%(P<.001). The selection of 3rd/4th Cephalosporin dropped from 11.8% to 5.8%(P=.020). The combination of antibiotics decreased from 27.8% to 11.7%(P<.001). The antibiotic prescription rate on discharge declined from 11.8% to 2.5%(P<.001) and the number of antibiotics prescription days after surgery was shortened from 4.2 days to 2.3 days(P<.001). No significant difference in the rate of administration within 1 hour between two groups was found. Through 3-year management, 5 out of 6 measures were significantly improved(except the administration within 1 hour). The rate of surgical site infection decreased from 2.4% to 1.3%(P=.504). Conclusion : The findings demonstrate that the management system for the prophylactic use of antibiotics in surgical patients was effective in decreasing the rate of surgical site infection during 3 years.

  • PDF

A Study on the Application of Phase Change Material for Electric Vehicle Battery Thermal Management System using Dymola (전기자동차 배터리팩 열관리시스템에서 상변화물질 적용에 관한 고찰)

  • Choi, Chulyoung;Choi, Woongchul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.12
    • /
    • pp.1889-1894
    • /
    • 2017
  • Global automobile manufacturers are developing electric vehicles (EVs) to eliminate the pollutant emissions from internal combustion vehicles and to minimize fossil fuel consumptions for the future generations. However, EVs have a disadvantage of shorter traveling distance than that of conventional vehicles. To answer this shortfall, more batteries are installed in the EV to satisfy the consumer expectation for the driving range. However, as the energy capacity of the battery mounted in the EV increases, the amount of heat generated by each cell also increases. Naturally, a better battery thermal management system (BTMS) is required to control the temperature of the cells efficiently because the appropriate thermal environment of the cells greatly affects the power output from the battery pack. Typically, the BTMS is divided into an active and a passive system depending on the energy usage of the thermal management system. Heat exchange materials usually include gas and liquid, semiconductor devices and phase change material (PCM). In this study, an application of PCM for a BTMS was investigated to maintain an optimal battery operating temperature range by utilizing characteristics of a PCM, which can accumulate large amounts of latent heat. The system was modeled using Dymola from Dassault Systems, a multi-physics simulation tool. In order to compare the relative performance, the BTMS with the PCM and without the PCM were modeled and the same battery charge/discharge scenarios were simulated. Number of analysis were conducted to compare the battery cooling performance between the model with the aluminum case and PCM and the model with the aluminum case only.

Performance Simulation of Flow Control Oil Pump for Auto Transmission According to Rotating Speed (자동변속기용 유량제어 오일펌프의 회전속도 변화에 따른 성능 해석)

  • Moon, Han-Byul;Cho, Hong-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.5
    • /
    • pp.3044-3050
    • /
    • 2015
  • The purpose of this study is to analyze the performance of the flow control oil pump for automatic transmission. The numerical model for analysis the performance of the flow control oil pump was develop and the characteristics of the internal flow, discharge flow rate, displacement of outer ring, driving torque, generation of cavitation was investigated according to rotating speed. As a result, the cavitation generation increased as the rotating speed increased. The volumetric efficiency was 90% for 2200 rpm and it decreased rapidly, then it decreased about 81% for 5000 rpm. Besides, the cavitation generation was 20%~30% for inlet of suction part, but it reduced below 13% owing to the compression. However, it shows higher cavitation generation for high rotating speed like 5000 rpm.

Unsteady Flow Analysis in the Youngsan River Using Explicit and Implicit Finite Difference Methods (양해법과 음해법을 이용한 영산강에서의 부정류해석)

  • Choi, Sung-Uk;Yeo, Woon-Kwang;Choo, Cheol;Kim, Chang-Wan;O, Yu-Chang
    • Water for future
    • /
    • v.24 no.4
    • /
    • pp.49-58
    • /
    • 1991
  • Flood routing in the Youngsan River was performed for the flood event of July, 1989 by two finite difference methods. The Saint Venant eq., a kind of hyperbolic partial differential equation is employed as governing equation and the explicit scheme (Leap Frog) and implicit scheme (Preissmann) are used to discretize the GE. As for the external boundary conditions, discharge and tidal elevation are upstream and downstream BC, respectively and estuary dam is included in internal BC. Lateral inflows and upstream discharges are the hourly results from storage function method, At Naju station, a Relatively upstream points in this river, the outputs are interpreted as good ones by comparing two numerical results of FDMs with the observed data and the calibrated results by storage function method. and two computational results are compared at the other sites, from middle stream and downstream points, and thus are considered reliable. Therefore, we can conclude from this research that these numerical models are adaptable in simulating and forecasting the flood in natural channels in Korea as well as existing hydrologic models. And the study about optimal gate control at the flood time is expected as further study using these models.

  • PDF