• 제목/요약/키워드: Internal discharge

검색결과 646건 처리시간 0.027초

Li4Ti5O12(LTO) 배터리 등가회로 모델링을 위한 내부 파라미터 체계적 해석 (Systematic Approach of Internal Parameters for Equivalent Electrical-Circuit Modeling(EECM) of a Li4Ti5O12(LTO) cell)

  • 이평연;윤창오;박진형;김종훈
    • 전력전자학회논문지
    • /
    • 제23권3호
    • /
    • pp.174-181
    • /
    • 2018
  • This study introduces a systematic approach to selecting the internal parameters applied to the equivalent electrical-circuit model (EECM) of a lithium titanium oxide ($Li_4Ti_5O_{12}$; LTO) rechargeable cell. Based on the dynamic characteristic of the cell, a simplified EECM consisting of an open-circuit voltage (OCV), an ohmic resistance, and an RC ladder is fabricated. To select the internal parameters of a simplified EECM, experiments on discharge capacity, OCV, and discharge/charge resistances are performed using hybrid pulse power characterization and direct current internal resistance (DCIR) measurements over the full state-of-charge (SOC) range. The experimental results of the LTO rechargeable cell highlight the importance of correct selection of internal parameters that can reduce EECM errors. This study clearly provides experimental procedures, internal parameters results, and EECM guidelines for adaptive control-based SOC estimation for LTO rechargeable cells.

고압전동기 고정자 권선의 PRPD 부분방전 결함신호 해석 (Analysis on Partial Discharge Fault Signals of PRPD for High Voltage Motor Stator Winding)

  • 박재준;이성룡;문대철
    • 한국전기전자재료학회논문지
    • /
    • 제19권10호
    • /
    • pp.942-946
    • /
    • 2006
  • We simulated insulation defects of stator winding wire on high voltage generator by 5 types. 4 types have one discharge source and other one has multi discharge source by simulation. For accurate decision, measurements used to PRPD pattern to occurred partial discharge source of various types. In this research, when PRPD pattern carried out or analyzed pattern recognition of discharge source, it used to powerful tools. In this result, PRPD Pattern defined to have single discharge source of 4 types by insulation defect. When insulation defect simulated, all the defected winding have not the same result. Errors for a little different can make mistakes from a subtle distinction. The difference between internal and void discharge have magnitude of pulse amplitude of inner discharge bigger than void discharge and have a shape of bisymmetry. But void discharge has a shape of bisymmetry against maximum value on polarity respectively. In cases of slot and surface discharge, we confirmed to show similar results those other researchers. In case of multi-discharge, as a result of we could classify not perfect match with occurred patterns in single discharge eachother. In the future, we will have to recognize and classify with results of multi-discharge.

몰드 변압기의 절연 진단을 위한 로고우스키형 부분방전 센서의 설계 및 제작 (Design and Fabrication of Rogowski-type Partial Discharge Sensor for Insulation Diagnosis of Cast-Resin Transformers)

  • 이경렬;김성욱;길경석
    • 한국전기전자재료학회논문지
    • /
    • 제35권6호
    • /
    • pp.594-602
    • /
    • 2022
  • Cast-resin transformers are widely installed in various electrical power systems because of their low operating cost and low influence on external environmental factors. However, when they have an internal defect during the manufacturing process or operation, a partial discharge (PD) occurs, and eventually destroys the insulation. In this paper, a Rogowski-type PD sensor was studied to replace commercial PD sensors used for the insulation diagnosis of power apparatus. The proposed PD sensor was manufactured with four different types of PCB-based winding structures, and it was analyzed in terms of the detection characteristics for standard calibration pulses and the changes of the output voltage according to the distance. The output increased linearly in accordance with the applied discharge amount. It was confirmed that the hexagon structure sensor had the highest sensitivity, because the winding cross-sectional area of the sensor was larger than others. In addition, as the distance from the defect increased, the output voltage of the sensors decreased by 7.32% on average. It was also confirmed that the attenuation rate according to the distance decreased as the input discharge amount increased. For the application of this new type sensor, PD electrode system was designed to simulate the void defect. Waveforms and PRPD patterns measured by the proposed PD sensors at DIV and 120% of DIV were the same as the results measured by MPD 600 based on IEC 60270. The proposed PD sensors can be installed on the inner wall of the transformer tank by coating its surfaces with a non-conductive material; therefore, it is possible to detect internal defects more effectively at a closer distance from the defect than the conventional sensors.

무성방전의 중첩을 이용한 다중방전형 오존발생기의 오존생성수율 개선 (Improvement of Ozone Yield by a Multi-Discharge Type Ozonizer Using Super position of Silent Discharge Plasma)

  • 송현직;이동헌;오진훈;박성욱;서영택
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.88-91
    • /
    • 2004
  • In order to improve ozone generation, we experimentally investigated the silent discharge plasma and ozone generation characteristics of a multi-discharge type ozonizer. Ozone in a multi-discharge type ozonizer is generated by superposition of a silent discharge plasma, which is simultaneously generated in separated discharge spaces. A multi-discharge type ozonizer is composed of three different kinds of superposed silent discharge type ozonizers, depending on the method of applying power to each electrode. We observed that the discharge period of the current pulse for a multi-discharge type ozonizer can be longer than that of silent discharge type ozonizer with two electrodes and one gap.Hence, ozone generation is improved up to 17185 ppm and 783 g/kwh for the superposed silent discharge type ozonizer for which an AC high voltages with a 180 phase difference were applied to the internal electrode and the external electrode, respectively, with the central electrode being ground

  • PDF

Hole drilling angle이 가솔린 직접 분사식 인젝터의 내부 유동에 미치는 영향 (Effects of Hole Drilling Angle on Internal Flow of Gasoline Direct Injection Injector)

  • 김휘준;박성욱
    • 한국분무공학회지
    • /
    • 제26권4호
    • /
    • pp.197-203
    • /
    • 2021
  • In gasoline direct injection injectors, cavitation can be generated inside the hole because of their high injection pressure. In this paper, the effects of cavitation development in injector were investigated depending on the various hole drilling angles were investigated by a numerical method. In order to verify the internal flow model, injection rate and injection quantity of individual holes were measured. The BOSCH long tube method was used to measure the injection rate. As a result, even if the hole diameters were the same, the discharge coefficient differed by up to 10% depending on the hole angle. Moreover, if the hole drilling angle became greater than 30°, the area coefficient and the discharge coefficient decreased as the nozzle outlet was blocked due to cavitation.

GIS 내 금속입자의 부상전압과 부분방전특성 연구 (Lift-Off Voltage and Partial Discharge Characteristics of Free Metallic Particles in GIS)

  • 윤진열;한상옥
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권2호
    • /
    • pp.127-132
    • /
    • 1999
  • Both motion of free metallic particles from which most GIS internal failures are caused and partial discharges from the particles were examined using EHV GIS test chamber. Effects from particle length and gas pressure which are main factors to lead to breakdown failure were investigated theoretically and experimentally. Magnitude of both lift-off voltage and partial discharge inception voltage were measured respectively and, through these measurements, this paper showed the possibility of predicting breakdown fault and of taking action to prevent the fault in advance. The measurement of partial discharge when the particles began to move could be adopted to decide minimum sensitivity in developing predictive diagnostic equipments. Both the amount of apparent discharge and real discharge in GIS were examined theoretically and experimentally, then experimental results were analyzed on the basis of the theory.

  • PDF

Off-line PD Model Classification of Traction Motor Stator Coil Using BP

  • Park Seong-Hee;Jang Dong-Uk;Kang Seong-Hwa;Lim Kee-Joe
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제5C권6호
    • /
    • pp.223-227
    • /
    • 2005
  • Insulation failure of traction motor stator coil depends on the continuous stress imposed on it and knowing its insulation condition is an issue of significance for proper safety operation. In this paper, application of the NN (Neural Network) as a scheme of the off-line PD (partial discharge) diagnosis method that occurs at the stator coil of a traction motor was studied. For PD data acquisition, three defective models were made; internal void discharge model, slot discharge model and surface discharge model. PD data for recognition were acquired from a PD detector. Statistical distributions and parameters were calculated to perform recognition between model discharge sources. These statistical distribution parameters are applied to classify PD sources by the NN with a good recognition rate on the discharge sources.

변압기 부분방전에 의한 초음파 신호의 발생형태 (Patterns of the Ultrasonic Signal caused by Partial Discharge in Transformer)

  • 권동진;최인혁;정길조;박찬영;나현석;박재준
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 하계학술대회 논문집
    • /
    • pp.581-584
    • /
    • 2000
  • Generally, it is known that many partial discharges are occurred in one voltage cycle. In this case, it is not easy to distinguish between ultrasonic signals caused by the partial discharge. We describes a pattern of the ultrasonic signal by the partial discharge in transformer. The test setup for ultrasonic signal measurement was to simulate a internal partial discharge by using a needle to plane electrodes. We compared the number of partial discharge and ultrasonic signal in one voltage cycle. The results showed that it was possible to distinguish between ultrasonic signals by analysing partial discharge detection method and ultrasonic signal on time domain.

  • PDF

액체 점도에 따른 Y-jet 노즐 내부 유동 및 분무 특성의 변화 (Effect of liquid viscosity on internal flow and spray characteristics of Y-jet atomizers)

  • 송시홍;이상용
    • 대한기계학회논문집B
    • /
    • 제20권12호
    • /
    • pp.4053-4061
    • /
    • 1996
  • Internal flow characteristics within Y-jet atomizers and the local drop size distribution and cross-sectional averaged drop size at the outside were investigated with the liquid and air injection pressures, mixing port length of atomizers, and the liquid properties taken as parameters. To examine the effect of the liquid viscosity, glycerin-water mixtures were used in this study. The liquid viscosity plays only a minor role in determining the internal flow pattern and the spatial distribution shape of drops, but the drop sizes themselves generally increase with increasing of the liquid viscosity. An empirical correlation for the liquid discharge coefficient at the liquid port was deduced from the experimental results; the liquid discharge coefficient strongly depends on the liquid flow area at the mixing point which is proportional to the local volumetric quality(.betha.$_{Y}$), and the volumetric quality was included in the correlation. Regardless of the value of the liquid viscosity, the compressible flow through the gas port was well represented by the polytropic expansion process(k=1.2), and the mixing point pressure could be simply correlated to the aspect ratio( $l_{m}$/ $d_{m}$) of the mixing port and the air/liquid mass flow rate ratio( $W_{g}$/ $W_{f}$) as reported in the previous study.udy.udy.y.

3상 전압인가형 중첩방전 오존발생기의 오존생성 상승효과 (Ozone Generation Synergy Effects of Three-Phase Voltage Apply Type Superposed Discharge Ozonizer)

  • 이병준;이상근;송현직;김영훈;박원주;이광식
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제49권8호
    • /
    • pp.468-476
    • /
    • 2000
  • Nowadays, ozone is mainly utilized for water treatment and home equipments. Although the demand for ozone is increasing, the ozone yield of silent discharge type ozonizer is low. Therefore, it is expected to improve the energy efficiency and ozone yield of an ozonizer. In this paper, a new ozone generation system is proposed. The 60[Hz] three-phase voltage is applied to three-phase superposed discharge type ozonizer(3PSDO) which has three electrodes(central, internal and external electrodes). There is no discharge pause time when three-phase voltage is applied due to 120-degree phase difference of applied voltage. The synergy effect of the three-phase superposed discharge type ozonizer is investigated by comparing with the three sort of single-phase discharge type ozonizer(1PDO). So, three-phase superposed discharge type ozonizer is able to obtain high ozone yield, and optimize discharge space, because this can increase the discharge power at low applied voltage.

  • PDF