• Title/Summary/Keyword: Internal discharge

Search Result 646, Processing Time 0.027 seconds

The Characteristics of the Complex Discharge Type Ozonizer using Applied Voltage of a Inverse-Polarity and a Screw Type Electrode (역극성 전압인가와 나사형 전극을 이용한 복합방전형 오존발생기의 특성)

  • Song, Hyun-Jig
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.9
    • /
    • pp.80-85
    • /
    • 2011
  • In this paper, complex discharge type ozonizer with a screw type electrode has been designed and manufactured for environmental improvement using low power and high efficency ozoniazer. The complex discharge type ozonizer is equipped with three electrodes{central electrode(CE), internal electrode(IE) and external electrode(EE)}. Ozone of the complex discharge type ozonizer is generated by superposition of silent discharge and surface discharge in discharge space as a screw type CE and IE are respectively applied to AC high voltage of inverse-polarity has $180[^{\circ}]$ phase difference, EE is common electrode. In this time, when oxygen has been used as supplied gas, the maximum values of ozone concentration, ozone generation and ozone yield were obtained as 8,334[ppm], 3,249[mg/h] and 65.3[g/kwh].

A Basic Study on Detection of Internal Defects in Distribution Cable Splices (배전용 전력 케이블 접속재의 내부고장 검출에 관한 기초연구)

  • 박치영;진상범;곽희로;김상준;송일근;권동진
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1996.11a
    • /
    • pp.122-124
    • /
    • 1996
  • This paper describes a diagnosis of distribution cable splices by analysis of ultrasonic signals which are generated by partial discharge. A method of ultrasonic signal was used to detect internal defects in distribution cable splices. It is possible that analysis of ultrasonic signal predicts failure by partial discharge generated in distribution cable splices.

  • PDF

A 30 W Copper Vapor Laser Using a Vacuum Tube Based Pulse Generator (진공관 전원방식 30 W급 구리증기레이저)

  • 진정태;차병헌;김철중;이흥호
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.12
    • /
    • pp.568-572
    • /
    • 2003
  • A longitudinal discharge heated copper vapor laser with internal diameter 28 mm and discharge length 1.3 m has been constructed and tested. At the discharging voltage 15.2 kV, pulse repetition rate 10 kHz, buffer gas pressure 40 mbar, and internal temperature of the laser plasma tube $1520^{\circ}C$, it delivers more than 30 W average laser outputs.

A Patient Presenting Purulent Discharge From Open Window Thoracostomy (전폐절제술 후 흉강개구부의 화농성 분비물을 보인 환자)

  • Kang, In Sook;Jung, Ji-Min;Ryu, Yon Ju;Kim, Yookyung;Lee, Jin Hwa;Cheon, Eun Mee;Nam, Dong Ki;Chang, Jung Hyun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.57 no.1
    • /
    • pp.78-81
    • /
    • 2004
  • A 73-year-old man who had undergone a right pneumonectomy and open window thoracostomy due to tuberculous empyema, presented with purulent discharge from the previous operation site. The computed tomography of the chest showed diffuse pleural thickening and a low attenuated lesion, with air bubbles in a dependent portion of the right hemithorax. These air bubbles were revealed to be due to 7 pieces of retained surgical gauze by flexible bronchoscopy. The patient showed marked clinical improvement with diminished purulent discharge after removal of the foreign bodies.

A Method to Monitor Vacuum Degree Using Capacitive Partial Discharge Coupler

  • Sun, Jong-Ho;Youn, Young-Woo;Hwang, Don-Ha;Yi, Sang-Hwa;Kang, Dong-Sik
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.6
    • /
    • pp.959-964
    • /
    • 2012
  • Internal pressure of vacuum interrupter (VI) is one of the most important parameters in VI operation and may increase due to the outgassing from the materials inside VI or gas permeation through metal flange or ceramic vessel. The increase of the pressure above a certain level leads to the failures of switching or insulation. Therefore, an effective pressure check of VI is essential and an analysis of partial discharge (PD) characteristics is an effective monitoring method to identify the degree of the internal pressure of VI. This paper introduces a research work on monitoring the internal pressure of VI by analyzing PDs which were measured using a capacitive PD coupler. The authors have developed cost effective capacitive coupler based on the ceramic material that has an excellent insulation properties and the main component of the capacitive coupler is made by SrTiO3. Detectable internal pressure range and distinguishability of the internal pressure of VI were investigated. From the PD tests results, the internal pressure range, from $10^{-2}$ torr to 500 torr, can be monitored by PD measurements using the capacitive coupler and PD inception voltage (PDIV) follows the Paschen's law. In addition, rise time of PD pulse at 13.2kV decreases with the increase of the internal pressure of VI.

Partial Discharge Position Tracking Method using a GIS Partial Discharge Signal and Arrival Time Difference (GIS 부분방전 신호와 도착 시간차 분석을 통한 PD발생 위치 추적)

  • Choi, Mun-Gyu;Cha, Hanju
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.9
    • /
    • pp.1297-1301
    • /
    • 2013
  • This paper analyzes of PD occurrence position through an analysis of the arrival time difference between the GIS partial discharge signal. Because of GIS (Gas Insulated Switchgear) is a facility very important power equipment and as part of the equipment that make up the power system, the stabilization of the power industry, which accounted for 88.5% share of GIS substation in the form of a substation is an important equipment for power supply. In the situation where we are gradually expanding the need for preventive diagnosis in order to improve the efficiency of equipment management and failure prevention for Preventive diagnosis. In this paper as a method for extracting pre-defect of failure of GIS Apply the average value method of calculating the 5 times each using a pulse of the first time of the second pulse (${\Delta}t$) with an oscilloscope generation position PD(Partial Discharge). the results of GIS internal inspection, the partial discharge of the actual the position of the partial discharge was confirmed with an accuracy of about 82% of positions. Arrival time difference in the most effective manner if the partial discharge of GIS internal occurs by applying the averaging method and TOA(Time of arrival) method, the partial discharge occurs you through the measurement and analysis of PD signal occurs was confirmed in the experiment are presented and diagnostic methods location tracking.

Characteristics of the Internal Flow in the Scaled-Up Fuel Nozzle (연료 노즐을 확대한 모형노즐에서의 내부유동 특성)

  • 박장혁;홍성태;구자예
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.4 no.3
    • /
    • pp.199-210
    • /
    • 1996
  • The measurements of velocities of internal flow in a scaled-up nozzle were made by laser Doppler velocimetry in order to clarify the effect of internal flow on the characteristics of fuel spray. The investigated length to diameter ratio(L/d) of the orifice were 1, 3, 4, 5 and 8, and inlet radius to diameter ratio(r0/d) were 0 and 0.5. Mean and fluctuating velocities and discharge coefficients were obtained at various Reynolds number ranging between 15,000 and 28,000, and L/d ranging between 1 and 8 in sharp and round inlet nozzle. The turbulent intensity and turbulent kinetic energy at exit in a sharp inlet nozzle were higher than that in a round inlet nozzle. For sharp inlet nozzle, fluctuating velocities near exit were decreased with increasing L/d.

  • PDF

The Performance Analysis of Direct Current Electromagnetic Propulsion in Seawater

  • Kong, Yeong-Kyung;Park, Tai-In;Kim, Yun-Sik;Noh, Chang-Joo
    • Journal of Energy Engineering
    • /
    • v.2 no.1
    • /
    • pp.38-44
    • /
    • 1993
  • Electromagnetic seawater thrusters may be classified into four general categories : internal duct dc, external field dc, internal peristaltic ac, and external peristaltic ac. Internal duct dc thrusters offer the advantages of low magnetic field leakage, simple construction, and potentially high reliability. The most efficient internal duct configuration consists of converging inlet nozzle and a straight discharge duct. Ideal efficiency calculations based on the one-dimensional Bernoulli equation show that thrusters should be designed with large cross-sectional areas and operate at low discharge velocities. In practice, this may be accomplished by using multiple thruster ducts. Conductivity enhancement, high magnetic fields, and long electrodes will also improve efficiency.

  • PDF

The Design and Experiment of a Planar Patch Sensor for Partial Discharge Diagnostics in 6.6 kV Rotating Machine Stator Windings

  • Yang, Sang-Hyun;Park, Noh-Joon;Park, Dae-Hee;Kim, Hee-Dong;Lim, Kwang-Jin
    • Transactions on Electrical and Electronic Materials
    • /
    • v.10 no.5
    • /
    • pp.173-176
    • /
    • 2009
  • In the stator windings of a 6.6 kV rotating machine, internal discharges, slot discharges, and surface discharges are mainly caused by internal voids and insulation degradation. If a partial discharge(PD) occurs in an inner-part of the stator windings, it will cause electromagnetic pulses with wide frequency ranges. Discharge sparks and electromagnetic pulses generated from a discharge source, can be detected using various RF resonators like an EM sensor. In order to detect these types of electromagnetic sources, a planar patch sensor was designed and fabricated using a CST-MWS simulation, and PD signals from an artificially defected stator winding were also measured by the sensor proposed in this study. Furthermore, an HFCT was used as a reference sensor and compared with the proposed new planar patch sensor. In the results of the experiment, the planar patch sensor showed a similar performance to the HFCT sensor.

Reasons and Risk Factors for Readmission Following Hospitalization for Community-acquired Pneumonia in South Korea

  • Jang, Jong Geol;Ahn, June Hong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.83 no.2
    • /
    • pp.147-156
    • /
    • 2020
  • Background: Limited studies have been performed to assess readmission following hospitalization for community-acquired pneumonia (CAP) in an Asian population. We evaluated the rates, reasons, and risk factors for 30-day readmission following hospitalization for CAP in the general adult population of Korea. Methods: We performed a retrospective observational study of 1,021 patients with CAP hospitalized at Yeungnam University from March 2012 to February 2014. The primary end point was all-cause hospital readmission within 30 days following discharge after the initial hospitalization. Hospital readmission was classified as pneumonia-related or pneumonia-unrelated readmission. Results: During the study period, 862 patients who survived to hospital discharge were eligible for inclusion and among them 72 (8.4%) were rehospitalized within 30 days. In the multivariable analysis, pneumonia-related readmission was associated with para/hemiplegia, malignancy, pneumonia severity index class ≥4 and clinical instability ≥1 at hospital discharge. Comorbidities such as chronic lung disease and chronic kidney disease, treatment failure, and decompensation of comorbidities were associated with the pneumonia-unrelated 30-day readmission rate. Conclusion: Rehospitalizations within 30 days following discharge were frequent among patients with CAP. The risk factors for pneumonia-related and -unrelated readmission were different. Aspiration prevention, discharge at the optimal time, and close monitoring of comorbidities may reduce the frequency of readmission among patients with CAP.