• Title/Summary/Keyword: Internal discharge

검색결과 646건 처리시간 0.025초

모의된 GIS에서 발생하는 부분방전에 관한 연구 (The Simulated study of different partial discharge sources in GIS)

  • 강대용;오광영;박대희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 E
    • /
    • pp.1737-1739
    • /
    • 1998
  • The paper presents experimental results of Partial Discharge(PD) in Gas Insulated Switchgear(GIS), obtained using a computer-aided PD measurement system. Different discharge sources are simulated and identified. These included internal, interface, surface and protrusion. For internal discharge, it showed symmetrical discharge type between positive and negative cycle. Interface discharge showed smaller number and higher peak than internal discharge but symmetrical discharge as well. For surface discharge, it showed small number and high peak in positive half cycle but large number and low peak in negative half cycle. For protrusion discharge, small number and high peak of discharge were shown only in negative half cycle.

  • PDF

다중방전형 오존발생기의 試作 및 特性(I) (Trial Manufacture and Characteristics of a Multi-discharge Type ozonizer(I))

  • 송현직;이광식;박원주;이동헌;김금영;김이국
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권7호
    • /
    • pp.533-541
    • /
    • 1999
  • Multi-discharge type ozonizer(MDO) using superposed silent discharge has been designed and manufactured. It consists of three electrodes( central electrode, internal electrode, and external electrode ) and double gaps( gap between central electrode and internal electrode, gap between internal electrode and external electrode ). Therefore, ozone is generated by superposing silent discharges generated between the gaps respectively. And the MDO consists of three types of superposed discharge ozonizers according to voltage appling method for each electrode ; A.C. high voltages are applied two of three electrodes with phase difference of 180[˚], the other electrode is a ground. This paper describes that discharge and ozone generation characteristics of MDO which comprising central electrode and internal electrode applied A.C. high voltages with phase difference of 180[˚] respectively, and the grounded external electrode. As a result, the maximum ozone concentration, generation, and yield can be obtained 10208[ppm], 6.4[g/h], and 280[g/kwh] respectively.

  • PDF

진공 방전관을 이용한 고농도 중첩방전형 오존발생기의 특성 (The Characteristics of a Superposed Discharge Type Ozonizer Using Vacuum Discharge Tube)

  • 송현직;이창호
    • 조명전기설비학회논문지
    • /
    • 제19권5호
    • /
    • pp.60-67
    • /
    • 2005
  • 본 논문에서는 진공방전관을 이용한 고농도 중첩방전형 오존발생기를 설계$\cdot$제작하였다. 3개의 전극(중심전극, 내부전극 및 외부전극)과 1개의 방전간극(내부전극과 외부전극 사이의 방전간극)으로 구성된 중첩방전형 오존발생기는 진공방전관내에 장착한 중심전극과 내부전극에 $180{[^\circ]}$의 위상차를 가진 2개의 교류고전압을 인가하고 외부전극을 공통접지함으로써 중심전극과 외부전극사이에서 발생되는 무성방전과 내부전극과 외부전극사이에서 발생되는 무성방전이 방전간극에서 중첩되는 구조이다. 이때 방전관의 진공도, 방전전력 및 산소원료가스 유량 변화에 따른 방전특성과 오존생성특성을 연구검토한 결과 최대 8840[ppm]의 고농도 오존을 얻을 수 있었다.

입원환자 한약투여와 약인성 간손상과의 관계 (Relationship between Herb-Medicine and Liver Damage)

  • 이시형;박정섭;여현수;최유경;전찬용;박종형;김동우
    • 대한한방내과학회지
    • /
    • 제27권3호
    • /
    • pp.572-578
    • /
    • 2006
  • Objectives : This study investigated whether taking herbal medicine over the long-term had any side effects of liver damage. Methods : We checked LFT levels of the 58 admitted patients. Results : When we compared admission LFT levels with discharge LFT levels, we found the levels of AST, ALT and LDH had decreased. This test showed statistically significant decrease. When we compared admission LFT levels with discharge LFT levels, we found the increases of discharge LFT levels fell within the standard deviation. When we compared admission LFT levels with discharge LFT levels, we found the levels of LFT did not increase as much as two standard deviations. Conclusions : According to the above results, taking herbal medicine over a long-term did not have any side effects of drug-induced liver damage.

  • PDF

3상전압을 이용한 중첩방전형 오존발생기의 특성 (The Characteristics of Superposed Ozonizer using Three-Phase Voltage)

  • 김영훈;전병준;송현직;윤영대;이광식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2259-2261
    • /
    • 1999
  • In this paper, an ozonizer, which can generate individual and superposed silent discharge, using three-phase voltage has been designed and manufactured. The ozonizer consists of 3 electrodes(Central Electrode, Internal Electrode and External Electrode) and 2 gaps(gap between Central Electrode and Internal Electrode, gap between Internal Electrode and External Electrode). Ozone is generated according to voltage supplying method to each electrode by individual silent discharge and three-phase superposed discharge. The characteristics of ozone generation were investigated with variation of discharge power and the quantity of supplied gas($O_2$). In case of individual silent discharge, the maximum values of ozone concentration, ozone generation and ozone yield were obtained between internal electrode and external electrode, and its values were 2300[ppm], 570[mg/h] and 745[g/kWh] respectively. Each maximum values was 5039[ppm], 1773[mg/h] and 851[g/kWh] respectively, when three-phase superposed silent discharge was employed. Therefore, characteristics of ozone generation with three-phase voltage are improved compared with single-phase voltage because silent discharge is generated continuously.

  • PDF

고주파전원형 오존발생기의 방전 캡 변화 특성 (Characteristics of Ozonizer with Variation of Vaccum in Internal Electrode)

  • 이창호;전병준;이상근;송현직;이광식
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2003년도 학술대회논문집
    • /
    • pp.381-385
    • /
    • 2003
  • In this paper, a co-axial type ozonizer varied with discharge gap was designed and manufactured for investigating $\circled1$ discharge characteristics with variation of output voltage power supply, flow rate and gap $\circled2$ ozone generation characteristics with variation of flow rate, gap and discharge power. pure oxygen was used as process gas of the co-axial type ozonizer. In this paper, a double cylindrical type superposed silent discharge type ozonizer which internal electrode can be produced a vacuum has been designed and manufactured. Discharge and ozone generation characteristics have been investigated in accordance with output voltage of power supply, flow-rate, discharge power and vacuum of internal electrode.

  • PDF

내부전극의 전공도 변화형 오존발생기의 특성 (Characteristics of Vaccum Variation Type Ozonizer of Internal Electrode)

  • 이창호;전병준;김영재;이광식
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2003년도 학술대회논문집
    • /
    • pp.387-391
    • /
    • 2003
  • In this paper, a double cylindrical type superposed silent discharge type ozonizer which internal electrode can be produced a vacuum has been designed and manufactured Discharge and ozone generation characteristics have been investigated in accordance with output voltage of power supply, flow-rate, discharge power and vacuum of internal electrode.

  • PDF

3상 전압을 사용한 중첩방전형 오존발생기의 오존생성 및 방전잡음특성 (The Ozone Generation and Discharge Noise Characteristics of Superposed Discharge Noise Characteristics of Superposed Discharge Type Ozonizer Using Three-Phase Voltage)

  • 전병준;송현직;김영훈;최상태;이광식
    • 조명전기설비학회논문지
    • /
    • 제14권2호
    • /
    • pp.59-67
    • /
    • 2000
  • 본 논문에서는 단목무성방전과 3상 전압을 사용한 중첩무성방전을 인가할 수 있는 오존발생기를 설계.제작하였다. 오존발생기는 3개의 전극(중심천극, 내부천극 및 외부전극)과 2개의 방전갭(중심전극과 내부전극 사이의 갭 및 내부전극과 외부전극 사이의 갭)으로 구성되어 있으며, 단목무성방전과 3상 중접방전이 인가되는 방식에 따라 오존화 가스가 생성된다. 이때 방전전력과 원료가스($O_2$)의 유량의 변화에 따른 오존생성특성을 연구한 결과, 단독무성방전의 경우, 최대 2300[ppm], 570[mg/h] 및 745[g/kWh]의 오존생성특성을 얻을 수 있었으며,3상 전압을 인가한 경우에는 5039[ppm], 1773[mg/h] 및 851[g/kWh]을 각각 얻을 수 있었다. 따라서 3상 중첩무성방전 이 단독무성방전에 비하여 오존생성특성올 향상시킬 수 있음을 확인하였다.

  • PDF

Implementation of an Inductively Coupled EM Probe System for PD Diagnosis

  • Kim, Hee-Dong;Park, Noh-Joon;Park, Dae-Hee
    • Journal of Electrical Engineering and Technology
    • /
    • 제6권1호
    • /
    • pp.111-118
    • /
    • 2011
  • In recent years, various types of partial discharge (PD) methods such as capacitive, inductive, electromagnetic, and acoustic coupling techniques have been developed for diagnosing rotating machines. An electromagnetic (EM) probe, which is an inductively coupled type of sensor, is required for detecting corona and internal discharges during off-line tests. In this study, a new technique for enhancing the measurement sensitivities for corona and internal discharge based on an EM inductive position sensor is proposed. An EM probe that winds wires around horseshoe-shaped and cylindershaped ferrites as helices is designed and optimized for the implementation of off-line PD monitoring of the stator winding of a rotating machine. The measurement system based on this design is implemented, and it is verified from the results of the experiment performed in this study that the probe provides similar performance as existing commercial products.

부싱에서 발생하는 부분방전 신호를 이용한 패턴분석(1) (Pattern Analysis by Using PD Signal generated in Bushings)

  • 이창준;박지훈;함길호;김혁태;김평중
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1951-1953
    • /
    • 2000
  • Partial Discharge is non-disruptive discharge, which can be discriminated to 3 kinds as firstly, internal discharge which is caused by internal voids inside of insulator, secondly, surface discharge which occurs from the surface of insulator and finally, corona discharge which is from the surface of an electrode. In this thesis, three kinds of defects are artificially made to the inside and the surface of the epoxy resine busing with internal voltage detection sensor, which is practically equipped into SF6 gas insulated switchgear for 22.9kV distribution line, so that discrimination of three kinds of PD signals by means of phi-q-n pattern analysis method was performed.

  • PDF