• Title/Summary/Keyword: Internal connection implant fixture

Search Result 48, Processing Time 0.023 seconds

A 3-dimensional finite element analysis of tapered internal connection implant system (Avana SS $III^{(R)}$) on different abutment connections (경사형 내부연결 임플란트 시스템 (SS $III^{(R)}$)에서 지대주 형태에 따른 응력분포의 3차원 유한요소 분석)

  • Lee, Hye-Sung;Kim, Myung-Rae;Park, Ji-Man;Kim, Sun-Jong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.3
    • /
    • pp.181-188
    • /
    • 2010
  • Purpose: The purpose of this study was to compare the stress distribution characteristics of four different abutment connections on SS-$III^{(R)}$ fixture under occlusal loading, using 3-dimensional finite element method. Materials and methods: The fixture of SS-$III^{(R)}$ (Osstem, Korea) with 4 mm diameter and 11.5 mm length and 4 types of abutments were analyzed; Solid, Com-Octa, ComOcta Gold, and Octa abutment. The models were placed in the area of first molar in the mandible. The 4 loading conditions were; (1) the vertical loading of 100 N on the central fossa, (2) the vertical loading of 100 N on the buccal cusp, (3) the $30^{\circ}$ inclined loading of 100 N to lingual side on the central fossa, and (4) the $30^{\circ}$ inclined loading of 100 N to the lingual side on the buccal cusp. The 3G.Author program was used, the von-Mises stress was calculated and the stress contours were plotted on each part of the implant systems and the surrounding bone structures. Results: Regardless of abutment types and loading conditions, higher stress concentration was observed at the cortical bone. In cancellous bone, the highest stress was observed at apical portion and the maximum stress occurred at the implant neck. The higher internal stress was observed in the fixtures than in the bone. The lowest stress was observed at loading condition 1 and the stress concentration was also lower than any other loading conditions. Conclusion: Within the limitation of the result of this study, it seems that the abutment connection type does not affect much on the stress distribution of bone structure.

Concept and application of implant connection systems: Part II. Placement and restoration of external connection implant and tissue level implant (임플란트 연결부의 개념과 적용: Part 2. 안착형 외부 및 내부 연결형 임플란트의 식립과 보철)

  • Ko, Kyung-Ho;Kang, Hyeon-Goo;Huh, Yoon-Hyuk;Park, Chan-Jin;Cho, Lee-Ra
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.4
    • /
    • pp.222-231
    • /
    • 2020
  • To use the external connection implant (EXT) appropriately, the inter-implant distance should be carefully considered during placement, and the bones raised above the implants should be trimmed during the second surgery. The hex abutment is more useful than the non-hex abutment. EXT is particularly useful when the inter-arch space is limited. The tissue level (TL, internal butt connection) implant has a biomechanical advantage of coronal wall thickness and a biological advantage of an inherent transmucosal smooth surface. During TL implant restoration, an abutment can be selected using the abutment and fixture margins with considerations for the inter-arch space. Since no single type of implant can satisfy all the cases, it is necessary to select the appropriate type, considering the occlusal force and the bone condition.

Clinical accuracy of impression technique using digital superimposition of customized abutment with subgingival margin: A case report (치은연하 변연을 가지는 맞춤형 지대주에서 디지털 중첩기술을 이용한 인상채득술의 임상 적용 증례)

  • Kim, Jin-Wan;Jeong, Chang-Mo;Yun, Mi-Jung;Lee, So-Hyoun;Lee, Hyeonjong;Huh, Jung-Bo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.2
    • /
    • pp.169-175
    • /
    • 2020
  • Traditionally, gingival retraction has been performed to obtain customized abutment impressions with subgingival margins of the implant supported prosthesis. However, gingival retraction may have side effects such as gingival recession and bleed, leading to an inaccurate impression. In order to prevent these problems, in this case, the new technique has been introduced; a customized abutment which is designed for superimposition is used. Before the connection of the abutment to the implant fixture, pre-scanned shape data are stored, and then the optical impression without gingival retraction is obtained after connecting to the fixture. The suprastructure is fabricated by superimposing the two data. This technique showed the clinical efficacy of fabricating the implant supported prosthesis with subgingival margin, which satisfied the aesthetics, convenience, and clinically acceptable marginal and internal fit.

Study on the stress distribution depending on the bone type and implant abutment connection by finite element analysis (지대주 연결 형태와 골질에 따른 저작압이 임프란트 주위골내 응력분포에 미치는 영향)

  • Park, Hyun-Soo;Lim, Sung-Bin;Chung, Chin-Hyung;Hong, Ki-Seok
    • Journal of Periodontal and Implant Science
    • /
    • v.36 no.2
    • /
    • pp.531-554
    • /
    • 2006
  • Oral implants must fulfill certain criteria arising from special demands of function, which include biocompatibility, adequate mechanical strength, optimum soft and hard tissue integration, and transmission of functional forces to bone within physiological limits. And one of the critical elements influencing the long-term uncompromise functioning of oral implants is load distribution at the implant- bone interface, Factors that affect the load transfer at the bone-implant interface include the type of loading, material properties of the implant and prosthesis, implant geometry, surface structure, quality and quantity of the surrounding bone, and nature of the bone-implant interface. To understand the biomechanical behavior of dental implants, validation of stress and strain measurements is required. The finite element analysis (FEA) has been applied to the dental implant field to predict stress distribution patterns in the implant-bone interface by comparison of various implant designs. This method offers the advantage of solving complex structural problems by dividing them into smaller and simpler interrelated sections by using mathematical techniques. The purpose of this study was to evaluate the stresses induced around the implants in bone using FEA, A 3D FEA computer software (SOLIDWORKS 2004, DASSO SYSTEM, France) was used for the analysis of clinical simulations. Two types (external and internal) of implants of 4.1 mm diameter, 12.0 mm length were buried in 4 types of bone modeled. Vertical and oblique forces of lOON were applied on the center of the abutment, and the values of von Mises equivalent stress at the implant-bone interface were computed. The results showed that von Mises stresses at the marginal. bone were higher under oblique load than under vertical load, and the stresses were higher at the lingual marginal bone than at the buccal marginal bone under oblique load. Under vertical and oblique load, the stress in type I, II, III bone was found to be the highest at the marginal bone and the lowest at the bone around apical portions of implant. Higher stresses occurred at the top of the crestal region and lower stresses occurred near the tip of the implant with greater thickness of the cortical shell while high stresses surrounded the fixture apex for type N. The stresses in the crestal region were higher in Model 2 than in Model 1, the stresses near the tip of the implant were higher in Model 1 than Model 2, and Model 2 showed more effective stress distribution than Model.

Retrospective Study of GS II Implant(Osstem) with an Internal Connection with Microthreads (Micro thread를 포함한 GSII RBM임플란트(Osstem)의 후향적 임상연구)

  • Chee, Young-Deok;Lee, Jae-Hwan;Oh, Sang-Chun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.4
    • /
    • pp.417-429
    • /
    • 2009
  • Since the introduction of the concept of osseointegration in dental implants, high long-term success rates have been achieved and accepted as viable option for the treatment of fully and partially edentulous patients. Although the use of domestic implants have increased dramatically, there are few studies on domestic implants with clinical and objective long-term data. 96 endosseous implants placed in 31 patients at Wonkwang University Sanbon Dental Hospital were examined to determine the effect of various factors on implant survival rate and marginal bone loss, through clinical and radiographic results. The design of endosseous implant used to this study is straight with the microthread.(GS II RBM Fixture) 1. 3 fixtures were lost, resulting in 96.9% cumulative survival rate. 2. Survival rate in fifties was significantly lower (93.6%) and no significant difference in marginal bone loss was found according to gender. 3. Survival rates were 95.6% in the maxillary molar area and 97.3% in the mandible molar area. 4. No significant difference in survival rate was found according to presence of bone grafts, type of prostheses, implant position, and length and diameter of implant. 5. A factor influencing marginal bone loss was presence of type of prostheses, while facters such a length, diameter of fixture and bone grafts had no statistically significant effect on crestal bone loss. This study indicates the amount of marginal bone loss around implant has maintained a relative stable during follow-up periods.

Retrospective study of the $Implantium^{(R)}$ implant with a SLA surface and internal connection with microthreads (SLA 표면 처리와 미세나사선을 가진 내측 연결형의 국산 임플란트에 대한 후향적 연구)

  • Doh, Re-Mee;Moon, Hong-Suk;Shim, Jun-Sung;Lee, Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.136-147
    • /
    • 2009
  • Statement of problem: Since the introduction of the concept of osseointegration in dental implants, high long-term success rates have been achieved. Though the use of dental implants have increased dramatically, there are few studies on domestic implants with clinical and objective long-term data. Purpose: The aim of this retrospective study was to provide long-term data on the $Implantium^{(R)}$ implant, which features a sandblasted and acid-etched surface and internal connection with microthreads. Material and methods: 106 $Implantium^{(R)}$ implants placed in 38 patients at Yonsei University Hospital were examined to determine the effect of various factors on implant success and marginal bone loss, through clinical and radiographic results during a 6 to 30 month period. Results: 1. Out of a total of 106 implants placed in 38 patients, one fixture was lost, resulting in a 99.1% cumulative survival rate. 2. Among the 96 implants which were observed throughout the study period, the survival rates were 97.0% in the maxilla and 100% in the mandible. The survival rate in the posterior regions was 98.9% and 100% in the anterior regions. 3. The mean bone loss during the first year after prosthesis placement was 0.17 mm, while the mean annual bone loss after the first year was 0.04 mm, which was statistically less than during the first year(P<.05). 4. There was no significant difference in marginal bone loss according to age during the first year(P>.05), but after the first year, the mean annual bone loss in patients above 50 years was significantly greater(P<.05) compared with patients under 50 years. 5. No significant difference in marginal bone loss was found according to the following factors: gender, jaw, location in the arch, type of implant(submerged or non-submerged), presence of bone grafts, type of prostheses, and type of opposing dentition(P<.05). Conclusion: Based on these results, the sole factor influencing marginal bone loss was age, while factors such as gender, jaw, location in the arch, type of implant, presence of bone grafts, type of prostheses and type of opposing dentition had no significant effect on bone loss. In the present study, the success rate of the $Implantium^{(R)}$ implant with a SLA surface and internal connection with microthreads was satisfactory up to a maximum 30 month period, and the marginal bone loss was in accord with the success criteria of dental implants.

Effect of various abutment systems on the removal torque and the abutment settling in the conical connection implant systems (원추형 연결 임플란트에서 지대주 종류에 따른 나사풀림과 침하현상에 관한 연구)

  • Lee, Jin-Seon;Lee, Joon-Seok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.2
    • /
    • pp.92-98
    • /
    • 2012
  • Purpose: The aim of this study was to evaluate the effects of different abutment materials on abutment screw loosening and settling-down effect in conical connection type implant system. Materials and methods: Three types of abutment, cementation, gold UCLA, and metal UCLA abutment were used. Two UCLA groups were fabricated in a similar pattern to cementation abutment. Type III gold alloy and Nickel-Chromium alloy was used for casting gold UCLA abutment and metal UCLA abutment, respectively. Fixture and abutment were tightened to 30 Ncm by using digital torque controller and re-tightening was conducted with same force after 10 minutes. Digital torque gauge was used to measure loosening torque and fixture/abutment length was measured by digital micrometer. Dynamic loads between 25 N and 250 N were applied with $0^{\circ}$ angle to the abutment axis. After loading, fixture/abutment length was re-measured and amount of settlement was calculated. Loosening torque value was also measured for comparison Results: All three groups showed significant differences of length when comparing before and after loading, but there was no significant difference of settling amount in all groups. Loosening torque values were significantly decreased when comparing before and after loading in all groups($P$<.05). However, there was no significant difference in loss of loosening torque values when compared to groups. Conclusion: In internal conical connection type implants, dynamic load affected on settlement and loosening torque of implant, but there was no differences between abutments materials. Likewise gold UCLA abutment, metal UCLA abutment might be able to withstand functional load.

A 10-year retrospective study on the risk factors affecting the success rate of internal connection implants after prosthetic restoration (내부연결 임플란트의 보철 수복 후 성공률에 미치는 위험요소에 관한 10년간의 후향적 연구)

  • Seoin Lee;Min-Jeong Kim
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.2
    • /
    • pp.113-124
    • /
    • 2023
  • Purpose. The purpose of this study is to help increase the success rate by analyzing the types and characteristics of implant prosthesis and the survival rate. Materials and methods. Among implants placed between 2011 and 2020 at Sanbon Dental Hospital, College of Dentistry, Wonkwang University, a case restored by a prosthetic surgeon was investigated for the characteristics and correlation of failure. The causes of failure were classified as failure of osseointegration, peri-implantitis, fixture fracture, abutment fracture, screw fracture, screw loosening, prosthesis fracture, and loss of prosthesis retention. Prosthetic method, cantilever presence, placement location, etc. were analyzed for their correlation with implant failure. Results analysis was derived through Chi-square test and Kaplan-Meier survival analysis using SPSS ver 25.0 (IBM, Chicago, IL, USA). Results. A total of 2587 implants were placed, of which 1141 implants were restored with Single Crown and 1446 implants with Fixed Partial Denture, and the cumulative survival rate was 88.1%. The success rate of SC was 86.2% (984) and the success rate of FPD was 89.6% (1295), showing statistically significant differences, among which factors that had significant differences were abutment fracture, screw fracture, and screw loosening (P < .05). Conclusion. As a result of the 10-year follow-up, more failures occurred due to biomechanical factors than biological factors. Further studies on the success of implants will be needed in the future.