• 제목/요약/키워드: Internal Parameter

검색결과 524건 처리시간 0.026초

Al 7075 합금의 크리이프 파단수명에 관한 연구(II) (A Study on the Creep Fracture Life of Al 7075 Alloy(II))

  • 강대민
    • 한국안전학회지
    • /
    • 제9권4호
    • /
    • pp.29-41
    • /
    • 1994
  • High temperature tensiles tests, steady state creep tests, internal stress tests and creep rupture tests using Al 7075 alloy were performed over the temperature range of 9$0^{\circ}C$~50$0^{\circ}C$ and stress range of 0.64~17.2(kgf/$\textrm{mm}^2$) in order to investigate the creep behavior and predict creep rupture life From the apparent activation energy Qc and the applied stress exponent n measured, at the temperature range of 9$0^{\circ}C$~l2$0^{\circ}C$, the creep deformation seemed to be controlled by cross slip. On the other hand at the temperature of 20$0^{\circ}C$~23$0^{\circ}C$ the creep deformation seemed to be controlled by dislocation climb but at 47$0^{\circ}C$~50$0^{\circ}C$, by diffusion creep. And the rupture life(t$_{f}$) might be represented by anthermal process attributed to the difference of the applied stress dependence of Internal stress and the ratio of the Internal stress to the applied stress, the thermal activated process attributied to the temperature dependence of the internal stress. Also the ratio between stress dependence of primary creep rate and that of minimum creep rate was measured 0.46, the minimum creep rate is expected to be appromately obtained from master creep curve including the relationship primary creep rate and minumum creep rate. Finally the relationship new rupture parameter and logarithmic stress was represented with including the ratio between the dependence of primary creep rate and that of minimum creep rate, using the new rupture parameter the rupture life predition is exactly expected.d.

  • PDF

Analytical Method를 이용한 고체 추진제 그레인의 Burn-back 연구 (Study on Solid Propellant Grain Burn-back Analysis Using Analytical Method)

  • 손지현;장진성;오석환;노태성
    • 한국추진공학회지
    • /
    • 제18권3호
    • /
    • pp.40-47
    • /
    • 2014
  • 우주발사체 최적 설계에 사용될 내탄도 해석 코드를 위한 그레인 Burn-back 연구를 수행하였다. 그레인 Burn-back은 내탄도 해석에 필수적인 그레인의 연소면적의 계산에 사용된다. 최적 설계에 사용될 내탄도 해석 코드는 설계 변수의 변경 및 반복계산을 통해 요구 성능을 만족할 때 까지 반복 계산을 수행한다. 따라서 내탄도 해석에 적용될 Burn-back 해석기법은 설계 변수의 변경이 용이하며 계산시간이 짧아야 한다. 이에 본 연구에서는 Analytical Method를 이용하여 Burn-back 해석코드를 개발하였으며, 그레인 형상에 대해 기하학적 변수를 선정 및 형상 변화에 대해 정리하였다. 개발된 코드는 Numerical Method로부터 산출된 값과 비교하여 검증을 수행하였다.

계자코일 파라메터추정 기법을 이용한 동기발전기의 성능개선 (Performance Improvement of Synchronous Generator using Exciter Control with Field Coils Parameter Estimation Technique)

  • 강성현;박성미;이화춘;박성준
    • 조명전기설비학회논문지
    • /
    • 제27권4호
    • /
    • pp.31-40
    • /
    • 2013
  • This paper proposes a performance improvement of synchronous generator using exciter control with field coils parameter estimation technique. In general, the generator excitation system controller uses the PID controller. When the Field winding impedance changed, the PID gains must be changed. General method is difficult to apply varying capacity of the synchronous generator. The proposed control method determine automatically measure the internal impedance of the synchronous generator's exciter and configure the controller. This method can be applied regardless of the generator capacity. So it is possible to apply a variety of synchronous generator systems. The validity of the proposed algorithm is verified by simulations and experiments.

정상인과 L4/L5 디스크 환자의 동적 근전도 측정을 통한 진단기법 개발

  • 현수돈;박시복;김정룡
    • 대한인간공학회:학술대회논문집
    • /
    • 대한인간공학회 1997년도 추계학술대회논문집
    • /
    • pp.426-432
    • /
    • 1997
  • 본 연구에서는 EMG를 이용한 수리적 parameter를 사용하여동일한 병명(L4/L5 herniated disk)의 요통환자들의 근육활동의 정상 여부를 측정하였다. 특히 본 연구에서는 동작분석기를 사용하지 않고 근 전도의 주기를 판독하여 기존의 연구에서 사용되었던 것보다 측정이간편하고, 주관적 통증 정도가 낮 은 환자를 대상으로 실험함으로써 통증이 parameter에 미치는 심리적 영향을 최소화하였다. 또한 본 연 구에서는 동작주기마다의 근전도 신호의 변이도(variance ratio)를 새로운 parameter로 선정하여 검증하 였다. 측정된 자료를 분석한 결과 quadriceps-hamstrings의 peak time difference와 erector spinae- rectus abdominis의 coexcitation이 통계적으로 매우 유의하게 요통환자와 정상인을 구분해주는 지표임이 확인되었고, rectus abdominis와 externa/internal oblique의 근전도 변이도(variance ratio)가 진단지표 로서 의미가 있음이 밝혀졌다. 본 연구의 방법은 차후 다양한 환자군에 대한 자료와 정상인에 대한 자료를 DB화 함으로써 진단기법으로 사용할 수 있는 가능성을 보여주었다. 이 방법은 차후 요통의 조기 발견과 예 방에 기여할 것으로 기대한다.

  • PDF

Electrospun polyamide thin film composite forward osmosis membrane: Influencing factors affecting structural parameter

  • Ghadiri, Leila;Bozorg, Ali;Shakeri, Alireza
    • Membrane and Water Treatment
    • /
    • 제10권6호
    • /
    • pp.417-429
    • /
    • 2019
  • Poly Sulfone nanofibers were electrospun to fabricate membranes of different characteristics. To fabricate the fiber mats, polymer concentration, flowrate, and current density were determined as the most influencing factors affecting the overall performance of the membranes and studied through Response Surface Methodology. The Box-Behnken Design method (three factors at three levels) was used to design, analyze, and optimize the parameters to achieve the best possible performance of the electrospun membranes in forward osmosis process. Also, internal concentration polarization that characterizes the efficiency of the forward osmosis membranes was determined to better assess the overall performance of the fabricated electrospun membranes. Water flux to reverse salt flux was considered as the main response to assess the performance of the membranes. As confirmed experimentally, best membrane performance with the minimal structural parameter value could be achieved when predicted optimal values were used to fabricate the membranes through electrospinning process.

Effect of the gravity on a nonlocal thermoelastic medium with a heat source using fractional derivative

  • Samia M. Said
    • Geomechanics and Engineering
    • /
    • 제37권6호
    • /
    • pp.591-597
    • /
    • 2024
  • The purpose of this paper is to depict the effect of gravity on a nonlocal thermoelastic medium with initial stress. The Lord-Shulman and Green-Lindsay theories with fractional derivative order serve as the foundation for the formulation of the fundamental equations for the problem. To address the problem and acquire the exact expressions of physical fields, appropriate non-dimensional variables and normal mode analysis are used. MATLAB software is used for numerical calculations. The projected outcomes in the presence and absence of the gravitational field, along with a nonlocal parameter, are compared. Additional comparisons are made for various fractional derivative order values. It is evident that the variation of physical variables is significantly influenced by the fractional derivative order, nonlocal parameter and gravity field.

반월지역 해성점토의 비배수 전단강도 특성에 관한 연구 (Study on the Undrained Shear Strength Characteristics)

  • 장병욱;박영곤
    • 한국농공학회지
    • /
    • 제36권3호
    • /
    • pp.90-99
    • /
    • 1994
  • To investigate the undrained shear strength characteristics of marine soils with high water content, high compressibility and weak bearing capacity, a series of undrained triaxial tests with pore pressure measurements on undisturbed and disturbed Banwol marine clay in normally consolidated and overconsolidated states is carried out. The results and main conclusions of this study are summarized as follows : 1 . When the consolidation pressure is increased, the maximum deviator stress of disturbed and undistubed clay in normally consolidated state is increased. Pore pressure parameters and internal friction angle of undisturbed clay are greater than those of disturbed clay. 2. The relationship between pore pressure and axial strain of undisturbed clay in normally consolidated state can be expressed as a hyperbolic function like stress-strain relation proposed by Kondner. 3. In the pore pressure-axial strain relation of disturbed clay in normally consolidated state, failure ratio R'f is greatly deviated in the range of 0.7~0.9 proposed by Christian and Desai. 4. For overconsolided clay, when overconsolidation ratio (OCR) is increased, normalized maximum deviator stress is increased and maximum pore pressure is decreased gradually. 5. Cohesion of overconsolidated clay is greater than that of nomally consolidated clay and internal friction angle slightly is decreased. 6. Pore pressure parameter at failure (Af) of overconsolidated clay is varied with OCR, Af becomes negative values with increment in OCR

  • PDF

Fundamental Small-signal Modeling of Li-ion Batteries and a Parameter Evaluation Using Levy's Method

  • Zhang, Xiaoqiang;Zhang, Mao;Zhang, Weiping
    • Journal of Power Electronics
    • /
    • 제17권2호
    • /
    • pp.501-513
    • /
    • 2017
  • The fundamental small-signal modeling of lithium-ion (Li-ion) batteries and a parameter evaluation approach are investigated in this study to describe the dynamic behaviors of small signals accurately. The main contributions of the study are as follows. 1) The operational principle of the small signals of Li-ion batteries is revealed to prove that the sinusoidal voltage response of a Li-ion battery is a result of a sinusoidal current stimulation of an AC small signals. 2) Three small-signal measurement conditions, namely stability, causality, and linearity, are proved mathematically proven to ensure the validity of the frequency response of the experimental data. 3) Based on the internal structure and electrochemical operational mechanism of the battery, an AC small-signal model is established to depict its dynamic behaviors. 4) A classical least-squares curve fitting for experimental data, referred as Levy's method, are introduced and developed to identify small-signal model parameters. Experimental and simulation results show that the measured frequency response data fit well within reading accuracy of the simulated results; moreover, the small-signal parameters identified by Levy's method are remarkably close to the measured parameters. Although the fundamental and parameter evaluation approaches are discussed for Li-ion batteries, they are expected to be applicable for other batteries.

임펄스 발생기의 회로 설계 파라미터 예측계산과 10/350${\mu}s$ 뇌임펄스 전류발생기 적용 (Design Circuit Parameter Estimation of Impulse Generator and its application to 10/350${\mu}s$ Lightning Impulse Current Generator)

  • 이재복;;장석훈;명성호;조연규
    • 전기학회논문지
    • /
    • 제57권10호
    • /
    • pp.1822-1828
    • /
    • 2008
  • This paper presents design parameter calculation methodology and its realization to construction for the 10/350${\mu}s$ lightning impulse current generator(ICG) modelled as double exponential function waveform with characteristic parameters ${\alpha},{\beta}$. Matlab internal function, "fzero" was applied to find ${\lambda}={\alpha}/{\beta}$ which is solution of nonlinear equation linearly related with two wave parameter $T_1$ and $T_2$. The calculation results for 10/350${\mu}s$ lightning impulse current show very good accuracy with error less 0.03%. Two type of 10/350${\mu}s$ ICGs based on the calculated design circuit parameters were fabricated by considering the load variation. One is applicable to the MOV based Surge protective device(SPD) for less 15 kA and the other is to test small resistive devices such as spark gap arrester and bonding device with maximum current capability 30 kA. The tested waveforms show error within 10% in comparison with the designed estimation and the waveform tolerance recommended in the IEC 61643-1 and IEC 60060-1.