• Title/Summary/Keyword: Internal Implant

Search Result 228, Processing Time 0.025 seconds

The Efficacy of Bioabsorbable Mesh in Craniofacial Trauma Surgery

  • Choi, Won Chul;Choi, Hyun Gon;Kim, Jee Nam;Lee, Myung Cheol;Shin, Dong Hyeok;Kim, Soon Heum;Kim, Cheol Keun;Jo, Dong In
    • Archives of Craniofacial Surgery
    • /
    • v.17 no.3
    • /
    • pp.135-139
    • /
    • 2016
  • Background: The ultimate goal of craniofacial reconstructive surgery is to achieve the most complete restoration of facial functions. A bioabsorbable fixation system which does not need secondary operation for implant removal has been developed in the last decade. The purpose of this study is to share the experience of authors and to demonstrate the efficacy of bioabsorbable mesh in a variety of craniofacial trauma operations. Methods: Between October 2008 and February 2015, bioabsorbable meshes were used to reconstruct various types of craniofacial bone fractures in 611 patients. Any displaced bone fragments were detached from the fracture site and fixed to the mesh. The resulting bone-mesh complex was designed and molded into an appropriate shape by the immersion in warm saline. The mesh was molded once again under simultaneous warm saline irrigation and suction. Results: In all patients, contour deformities were restored completely, and bone segments were fixed properly. The authors found that the bioabsorbable mesh provided rigid fixation without any evidence of integrity loss on postoperative computed tomography scans. Conclusion: Because bioabsorbable meshes are more flexible than bioabsorbable plates, they can be molded and could easily reconstruct the facial bone in three dimensions. Additionally, it is easy to attach bone fragments to the mesh. Bioabsorbable mesh and screws is effective and can be easily applied for fixation in various craniofacial trauma reconstructive scenarios.

Cellular study of replicative senescence in human periodontal ligament fibroblast using molecular biology (분자생물학을 이용하여 복제노화된 사람치주인대섬유모세포의 세포학적 연구)

  • Kim, Byung-Ock;Cho, Il-Jun;Park, Joo-Cheol;Kook, Joong-Ki;Kim, Heung-Joong;Jang, Hyun-Seon
    • Journal of Periodontal and Implant Science
    • /
    • v.35 no.3
    • /
    • pp.623-634
    • /
    • 2005
  • Human periodontal ligament fibroblast(hPDLF) is very important to cure periodontal tissue because it can be diverged into various cells. This study examined the expression of MMP-1, TIMP-1, periodontal ligament specific PDLs22, Type I collagen, Fibronectin, TIMP-2, telomerase mRNA in a replicative senescence of hPDLF. The periodontal ligament tissue was obtained from periodontally healthy and non-carious human teeth extracted for orthodontic reasons at the Chosun University Hospital of Dentistry with the donors' informed consent. The hPDLF cells were cultured in a medium containing Dulbecco's modified Eagle medium(DMEM, Gibco BRL, USA) supplemented with 10% fetal bovine serum(FBS, Gibco BRL, USA) at 37C in humidified air with 5% $CO_2$. For the reverse transcription-polymerase chain reaction(RT-PCR) analysis, the total RNA of the 2, 4, 8, 16, 18, and 21 passage cells was extracted using a Trizol Reagent(Invitrogen, USA) in replicative hPDL cells. Two passage cells, i.e. young cells, served as the control, and ${\beta}-actin$ served as the internal control for RT-PCR The results of this study about cell morphology and gene expression according to aging of hPDLF using RT-PCR method are as follows: 1. The size of hPDLF was increased with aging and it was showed that the hPDLF was dying in the final passage. 2. PDLs22 mRNA was expressed in young hPDLF of the two, four, and six passage. 3. TIMP-1 mRNA was expressed in young hPDLF of the two and four passage. 4. There was a tendency that MMP-1 mRNA was weakly expressed over eighteen. 5. Type 1 collagen mRNA was expressed in almost all passages, but it was not expressed in the final passage. 6. Fibronectin mRNA was observed in all passages and it was weakly expressed in the final passage. 7. TIMP-2 and telomerase mRNA were not expressed in this study. Based on above results, it was observed that PDLs22, Type 1 collagen, Fibronectin, MMP-1. and TIMP-1 mRNA in hPDLF were expressed differently with aging. The study using the hPDLF that is collected from healthy patients and periodontitis patients needs in further study.

Surgical Treatment of Metastatic Pathologic or Impending Pathologic Fractures (전이성 병적 골절 또는 병적 임박 골절의 수술적 치료)

  • Kim, Kap-Jung;Lee, Sang-Ki;Choy, Won-Sik;Seo, Dong-Wook
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.15 no.1
    • /
    • pp.44-51
    • /
    • 2009
  • Purpose: We evaluated the results of surgical treatment for metastatic pathologic or impending pathologic fractures. Materials and Methods: From January 2004 to December 2007, 18 patients 19 cases were included. Male were 6 and female were 12. The mean age was 65.1. Mean follow up period was 15.2 months. Pathologic fractures were 14 and impending pathologic fractures were 5. MSTS score, periodic radiologic follow up and postoperative complications were evaluated. Results: The primary malignancies were 6 cases of multiple myeloma, 4 cases of renal cell carcinoma, 2 cases of cholangiocarcinoma, 2 cases of colon cancer, 2 cases of breast cancer and 2 cases of leiomyosarcoma. Metastatic lesions were 10 cases of femur, 4 cases of clavicle, 2 cases of humerus, 2 cases of tibia and 1 case of radius. Surgical options were curettage, cementation, internal fixation and arthroplasty. Mean MSTS score was 15.9. Postoperative complications were 1 case of infection, 1 case of local recurrence and 1 case of implant loosening. Ten patients were alive with disease, 8 patients died of disease. Conclusion: Surgical treatment of metastatic skeletal lesions allowed early ambulation and improving dexterity. It improved pain and emotional acceptance. Surgery is necessary for improving qualities of remaining lives.

  • PDF

Analysis of residual stress of Nitinol by surface Polishing Method (표면 연마 방법에 따른 니티놀 잔류응력 분석)

  • Jeong, Ji-Seon;Hong, Kwang-Pyo;Kim, Woon-yong;Cho, Myeong-Woo
    • Design & Manufacturing
    • /
    • v.11 no.2
    • /
    • pp.51-56
    • /
    • 2017
  • Nitinol, a shape memory alloy (SMA), is manufactured from titanium and nickel and it used in various fields such as electrical applications, micro sensors. It is also recommended as a material in medical for implant because it has excellent organic compatibility. Nitinol is intended to be inserted into the human body, products require a high-quality surface and low residual stress. To overcome this problems, explore electrolyte polishing (EP) is being explored that may be appropriate for use with nitinol. EP is a particularly useful machining method because, as a non contact machining method, it produces neither machining heat nor internal stress in the machined materials. Sandpaper polishing is also useful machining method because, as a contact machining method, it can easily good surface roughness in the machined materials. The electrolyte polishing (EP) process has an effect of improving the surface roughness as well as the film polishing process, but has a characteristic that the residual stress is hardly generated because the work hardened layer is not formed on the processed surface. The sandpaper polishing process has the effect of improving the surface roughness but the residual stress remains in the surface. We experimented with three conditions of polishing process. First condition is the conventional polishing. Second condition is the electrochemical polishing(EP). And Last condition is a mixing process with the conventional polishing and the EP. Surface roughness and residual stress of the nitinol before a polishing process were $0.474{\mu}mRa$, -45.38MPa. Surface roughness and residual stress of the nitinol after mixing process of the conventional polishing and the EP were $1.071{\mu}mRa$, -143.157MPa. Surface roughness and residual stress of the nitinol after conventional polishing were $0.385{\mu}mRa$ and -205.15MPa. Surface roughness and residual stress of sandpaper and EP nitinol were $1.071{\mu}mRa$, -143.157MPa. The result shows that the EP process is a residual stress free process that eliminates the residual stress on the surface while eliminating the deformed layer remaining on the surface through composite surface machining rather than single surface machining. The EP process can be used for biomaterials such as nitinol and be applied to polishing of wafers and various fields.

Periodontal pathogens and the association between periodontitis and rheumatoid arthritis in Korean adults

  • Kim, Jin-Hee;Choi, In Ah;Lee, Joo Youn;Kim, Kyoung-Hwa;Kim, Sungtae;Koo, Ki-Tae;Kim, Tae-Il;Seol, Yang-Jo;Ku, Young;Rhyu, In-Chul;Song, Yeong Wook;Lee, Yong-Moo
    • Journal of Periodontal and Implant Science
    • /
    • v.48 no.6
    • /
    • pp.347-359
    • /
    • 2018
  • Purpose: Periodontitis and rheumatoid arthritis (RA) share a similar inflammatory pathogenesis. Porphyromonas gingivalis (Pg) can induce anticyclic-citrullinated peptide autoantibodies (anti-CCP antibodies), a key factor in the development of RA. This study aimed at evaluating the relationships between the 2 diseases and identifying the clinical implications thereof, with a focus on periodontal pathogens in Korean adults. Methods: A total of 260 RA patients and 86 age- and sex-matched control patients without arthritis were enrolled in this prospective cross-sectional study. Periodontal indices and the prevalence and amount of periodontal pathogens were compared between the groups. Correlations between periodontal and RA indices were examined, as were correlations between 9 periodontal pathogens and RA indices. Results: The RA group had significantly higher values than the control group for all investigated periodontal indices (P<0.05) except the number of teeth. The gingival index (GI) was correlated with the disease activity score 28 (DAS28) (r=0.125, P=0.049), RA disease duration (r=0.253, P<0.001), erythrocyte sedimentation rate (ESR) (r=0.162, P=0.010), and anti-CCP antibody titer (r=0.205, P=0.004). Probing pocket depth (PPD) was correlated with ESR (r=0.139, P=0.027) and anti-Pg antibody titer (r=0.203, P=0.001). Bleeding on probing (BOP) was correlated with DAS28 (r=0.137, P=0.030), RA disease duration (r=0.202, P=0.001), ESR (r=0.136, P=0.030), anti-Pg antibody titer (r=0.177, P=0.005), and anti-CCP antibody titer (r=0.188, P=0.007). Clinical attachment level (CAL) and periodontitis severity were correlated with anti-Pg antibody titer (the former r=0.201, P=0.002; the latter r=0.175, P=0.006). The quantity of Pg was positively correlated with the serum anti-Pg antibody titer (r=0.148, P=0.020). Conclusions: The GI, BOP, and PPD showed positive relationships with several RA indices. The anti-Pg antibody titer had positive relationships with PPD, BOP, CAL, and periodontitis severity. Thus, increasing values of periodontal indices could be used as a risk indicator of disease development in RA patients, and an increasing anti-Pg antibody titer could be considered as a warning sign in RA patients suffering with periodontitis.

Use of custom glenoid components for reverse total shoulder arthroplasty

  • Punyawat Apiwatanakul;Prashant Meshram;Andrew B. Harris;Joel Bervell;Piotr Lukasiewicz;Ridge Maxson;Matthew J. Best;Edward G. McFarland
    • Clinics in Shoulder and Elbow
    • /
    • v.26 no.4
    • /
    • pp.343-350
    • /
    • 2023
  • Background: Our purpose was to evaluate a custom reverse total shoulder arthroplasty glenoid baseplate for severe glenoid deficiency, emphasizing the challenges with this approach, including short-term clinical and radiographic outcomes and complications. Methods: This was a single-institution, retrospective series of 29 patients between January 2017 and December 2022 for whom a custom glenoid component was created for extensive glenoid bone loss. Patients were evaluated preoperatively and at intervals for up to 5 years. All received preoperative physical examinations, plain radiographs, and computed tomography (CT). Intra- and postoperative complications are reported. Results: Of 29 patients, delays resulted in only undergoing surgery, and in three of those, the implant did not match the glenoid. For those three, the time from CT scan to implantation averaged 7.6 months (range, 6.1-10.7 months), compared with 5.5 months (range, 2-8.6 months) for those whose implants fit. In patients with at least 2-year follow-up (n=9), no failures occurred. Significant improvements were observed in all patient-reported outcome measures in those nine patients (American Shoulder and Elbow Score, P<0.01; Simple Shoulder Test, P=0.02; Single Assessment Numeric Evaluation, P<0.01; Western Ontario Osteoarthritis of the Shoulder Index, P<0.01). Range of motion improved for forward flexion and abduction (P=0.03 for both) and internal rotation up the back (P=0.02). Pain and satisfaction also improved (P<0.01 for both). Conclusions: Prolonged time (>6 months) from CT scan to device implantation resulted in bone loss that rendered the implants unusable. Satisfactory short-term radiographic and clinical follow-up can be achieved with a well-fitting device. Level of evidence: III.

Histological Observation of Bone Reaction with Relation to Surface Treatment of Titanium (생체합금 Titanium의 표면처리에 따른 골반응의 변화에 대한 조직학적 관찰)

  • Ahn, Myun-Whan;Choi, Yong-Sug;Ahn, Jong-Chul;Seo, Jae-Sung;Lee, Dong-Chul;Jang, Jae-Hyuk
    • Journal of Yeungnam Medical Science
    • /
    • v.13 no.1
    • /
    • pp.116-133
    • /
    • 1996
  • The biocompatibility of the titanium has been estabilished through various experimental studies such as cell culture toxicity test, pyrogen test, mutagen test and others. In order to confirm biocompatibility after fabrication of titanium and to clarify the difference between the bone reaction after insertion of the lathed titanium rods and the bone reaction after insertion of the finished and polished rods, both rods were implanted into the proximal femur of a rabbit. Histologic reactions in the bone were observed according to the ASTM standards at the intervals of 6 weeks, 12 weeks and 26 weeks after implantation. The result were as follows : In 6 weeks after implantation of lathed titanium rods, inflammatory reactions, such as minimal degree infiltration of polymorphonuclear leukocytes and lymphocytes were observed in all cases. This was thought to he caused by surgical trauma. However, inflammatory cell infiltration was not seen after implantation of polished and finished rods in all cases. The cellular infiltration and the histologic reaction of the hone after implantation of lathed group were significantly more pronounced than those after implantation of the finished group. In 12 weeks after implantation of lathed rods, two of four cases revealed a minimal degree of cellular infiltration. No inflammatory cell infiltration was demonstrated after implantation of the finished group. The cellular infiltration and histologic reaction seemed to be more pronounced in the lathed group, but they were not significant statistically. At 26 weeks after implantation of the lathed and finished group, there was no cellular infiltration in both groups. New bone formation was observed up 26 weeks, and no difference between lathed titanium rods and finished titanium rods were apparent. Mild bone necrosis was observed in 1 case out of 11 cases in which lathed titanium rods were implanted. Bone necrosis was not observed in the finished titanium rod group. Fibrosis was observed in both groups, but differences were not significant between the experimental groups. In the lathed titanium rods group and the shorter interval group, inflammatory cell infiltration was significantly higher. Finished titanium rods and longer interval groups had markedly decreased tendences in histologic reaction ratings. As a conclusion, although certificated titanium might be safe to use, difference of biocompatibility were observed depending on the method of surface finish. By identifying biocompatibility as a long-term standardized animal study, we can develop progressed internal fixation device that is safe for human beings.

  • PDF

The Difference between Short and Long Intramedullary Nailing as the Treatment for Unstable Intertrochanteric Femoral Fracture (AO/OTA 31-A2) in Elderly Patients (고령환자에서 발생한 불안정성 대퇴골 전자간부 골절(AO/OTA 31-A2)의 치료 시 골수강내 금속정의 길이에 따른 추시 결과)

  • Shin, Won Chul;Lee, Eun Sung;Suh, Kuen Tak
    • Journal of the Korean Orthopaedic Association
    • /
    • v.52 no.1
    • /
    • pp.25-32
    • /
    • 2017
  • Purpose: The purpose of this study was to analyze the radiological and clinical outcomes in elderly patients with unstable intertrochanteric femur fractures in accordance with the length of intramedullary nail. Materials and Methods: Between August 2009 and December 2014, a total of 139 patients-older than 65 years of age with AO/OTA classification of 31-A2 unstable intertrochanteric femur fracture-who has been followed-up for at least 1 year after the treatment with internal fixation by using an intramedullary nail were enrolled for this retrospective control study. The subjects were classified into two groups according to the length of intramedullary nail: 106 patients in the short group (group I) and 33 patients in the long group (group II). For radiological assessments, the reduction state, time to union, and implant related complications were examined. The clinical outcomes were assessed by preoperative hemoglobin, operating time, intraoperative bleeding amount, blood transfusion rate, hospitalization period, and Charnley hip pain scoring system at the final follow-up. Results: The postoperative radiographs showed good or acceptable reduction in all cases. The mean time of radiologic bone union was 4.8 months, and there was no difference between the two groups. With respect to surgical time, the group II was found to take longer (57.87 minutes) than the group I (45.65 minutes) (p=0.003). The bleeding amount during surgery of the group II was greater (288.78 ml) than that of the group I (209.90 ml) (p=0.046). The clinical results at the final follow-up were found to be satisfactory in both groups. Conclusion: In cases of good reduction of the fracture from the treatment of unstable intertrochanteric femur fracture accompanying the posteromedial fragment in elderly patients, both groups-long and short intramedullary nails-showed satisfactory radiological and clinical outcomes.