• Title/Summary/Keyword: Internal Implant

Search Result 228, Processing Time 0.023 seconds

Resorbability and histological reaction of bioabsorbable membranes (수종의 흡수성 차단막의 생체 분해도와 조직학적 반응)

  • Suk, Hun-Joo;Kwon, Suk-Hoon;Kim, Chang-Sung;Choi, Seong-Ho;Jeon, Dong-Won;Kim, Chong-Kwan
    • Journal of Periodontal and Implant Science
    • /
    • v.32 no.4
    • /
    • pp.781-800
    • /
    • 2002
  • The major goals of periodontal therapy are the functional regeneration of periodontal supporting structures already destructed by periodontal disease. There have been many efforts to develop materials and therapeutic methods to promote periodontal wound healing. With the development of non-resorbable membrane, GTR has proved to be the representive technique of periodontal regeneration. However, due to various clinical problems of non-resorbable membrane, resorbable membrane was developed and it showed to be clinically effective. The newly developed Para-Dioxanone membrane has a characteristic of non-woven fabric structures which is different from the generally used membranes with structure of mesh form. In addition, Chitosan membrane has been developed to apply its adventage maximally in GTR. Although a number of different types of membranes had been clinically used, researches on absorption rate of membranes were inadequate and limited to subjective opinions. However, since long term period of resorption and space maintenance are required in implant or ridge augmentation, accurate verification of resorption rate is clinically important. In this study, we had implanted Resolut(R), Biomesh(R), Para-Dioxanone membrane and Chitosan membrane (Size : 4mm ${\times}$ 4mm) on dorsal side of Sprague Dawley rat, and sacrified them after 4 weeks, 8 weeks, 12 weeks respectively. Histologic observation was carried out, and the following results were obtained by calculating the objective resorption rate. 1. In case of Resolut(R), external resorption took place initially, followed by internal resorption. Surface area are 5.76${\pm}$2.37$mm^2$, 4.90${\pm}$l.06$mm^2$, 4.90${\pm}$0.98$mm^2$ at 4 weeks, 8 weeks, 12 weeks respectively, and invasion rate of connective tissue to membrane are 31.6${\pm}$4.5%, 52.8${\pm}$9.4%, 56.4${\pm}$5.1% respectively. 2. Biomesh(R) showed a pattern of folding, relatively slow resorption rate with small size of membrane. Surface area are 3.62${\pm}$0.82$mm^2$, 3.63${\pm}$0.76$mm^2$, 4.07${\pm}$1.14$mm^2$ at 4 weeks, 8 weeks, 12 weeks respectively, and invasion rate of connective tissue to membrane are 26.1${\pm}$5.8%, 30.9${\pm}$3.4%, 29.2${\pm}$3.6%, respectively. 3. Para-Dioxanone membrane was surrounded by fibrous conncetive tissue externally, and resorption took place internally and externally. Surface area are 5.96${\pm}$1.05$mm^2$, 4.77${\pm}$10.76$mm^2$, 3.86${\pm}$0.84$mm^2$ at 4 weeks, 8 weeks, 12 weeks respectively, and invasion rate of connective tissue to membrane are 30.7${\pm}$5.1%, 53.3${\pm}$4.4%, 69.5${\pm}$3.1%, respectively. 4. Each fiber of Chitosan membrane was surrounded by connective tissue and showed external resorption pattern. It showed little invasion of inflammatory cells and excellent biocompatability. The resorption rate was relatively slow. Surface area are 6.01${\pm}$2.01$mm^2$, 5.49${\pm}$1.3$mm^2$, 5.06${\pm}$1.38$mm^2$ at 4 weeks, 8 weeks, 12 weeks respectively, and invasion rate of connective tissue to membrane are 31.3${\pm}$3.6%, 38.4${\pm}$3.80%, 39.7${\pm}$5.6%, respectively. Consequently, Para-Dioxanone membrane and Chitosan membrane are found to be clinically effective for their excellent tissue reaction and biocompatibility. Futhermore, the advantage of bone regenerating ability as well as the relatively long resorption period of Chitosan membrane, it might be widely used in implant or ridge augmentation.

A study of the cause of metal failure in treatment of femur shaft fracture - Fractographical and clinical analysis of metal failure- (대퇴골 간부 골절시 사용한 금속물의 금속부전(Metal failure)의 기전에 대한 연구)

  • Jeon, Chun-Bae;Seo, Jae-Sung;Ahn, Jong-Chul;Ahn, Myun-Whan;Ihn, Joo-Chyl
    • Journal of Yeungnam Medical Science
    • /
    • v.7 no.1
    • /
    • pp.81-93
    • /
    • 1990
  • The author fractographically analyized the cause of metal failure(the first time this procedure has been used for this metal failure)and also analyized it clinically. In this study, I selected eight cases which have been analyized fractographically. In all these cases, the analysis was done after treatment of metal failure of implants internally fixed to femur shaft fractures at the Department of Orthopedic Surgery, Yeung-Nam University Hospital during the six year period from May 1983 to September 1989. 1. Metal failure occured in five dynamic-compression plates, one Jewett nail, one screw in Rowe plate, and one interlocking nail. 2. The clinical cause of metal failure was deficiency of medial butress in five cases, incorrect position of implant in one case, and incorrect selection of implant in two cases. 3. The time interval between internal fixation and metal failure was four months in one case, between five months to twelve months in six cases, three years in one case. 4. The fractographically analytical cause of metal failure was ; first, impact failure, one case, second, fatigue failure, six cases, machining mark(stress liser), four cases type : low consistent cyclic fatigue failure irregular cyclic fatigue failure third, stress corrosion crack, one case. 5. 316L Stainless Steel has good resistance to corrosion. However, when its peculiar surface film is destroyed by fretting, it shows pitting corrosion. This is, perhaps, the main cause of metal failure. 6. It is possible that mechanical injury occured in implants during the manufacturing of implants or that making a screw hole is the main cause of metal failure.

  • PDF

Accuracy of implant digital scans with different intraoral scanbody shapes and library merging according to different oral exposure height (구내 스캔바디의 형태에 따른 임플란트의 디지털 스캔 정확도 및 구강 내 노출 높이에 따른 라이브러리 중첩 정확도 비교 연구)

  • Jeong, Byungjoon;Lee, Younghoo;Hong, Seoung-Jin;Paek, Janghyun;Noh, Kwantae;Pae, Ahran;Kim, Hyeong-Seob;Kwon, Kung-Rock
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.1
    • /
    • pp.27-35
    • /
    • 2021
  • Purpose: The purpose of this study is to compare the accuracy of digital scans of implants according to different shapes of scanbodies, and to compare the accuracy of library merging according to different oral exposure height. Materials and methods: A master model with a single tooth edentulous site was prepared. For the first experiment, three types of intraoral scanbodies were prepared, divided into three groups, and the following experiments were conducted for each group: An internal hex implant was placed. The master model with the scanbody connected was scanned with a model scanner, and a master reference file (control group) was created. 10 files (experimental group) were created by performing 10 consecutive scans with an intraoral scanner. After superimposing the control and experimental groups, the following values were calculated: 1) Distance deviation of a designated point on the scanbody 2) Angle deviation of the major axis of the scanbody. For the second experiment, the scanbody scan data were prepared in 6 different heights. Library files were merged with each of the scan data. The distance and angular deviation were calculated using the 7 mm scan data as control group. Results: In the first experiment, there were no significant differences between A and B (P=.278), B and C (P=.568), and C and A (P=.711) in the distance deviations. There were no significant differences between A and B (P=.568), B and C (P=.546), and C and A (P=.112) in the angular deviations. Also, the scanbody showed significantly higher library merging accuracy in the groups with high oral exposure height (P<.5). Conclusion: There were no significant differences in scan accuracy according to the different shapes of scanbodies, and the accuracy of library merging increased according to exposure height of the scanbody in the oral cavity.

Aseptic Humeral Nonunion: What Went Wrong? What to Do? A Retrospective Analysis of 20 Cases

  • Kim, Jinil;Cho, Jae-Woo;Cho, Won-Tae;Cho, Jun-Min;Kim, Namryeol;Kim, Hak Jun;Oh, Jong-Keon;Kim, Jin-Kak
    • Journal of Trauma and Injury
    • /
    • v.29 no.4
    • /
    • pp.129-138
    • /
    • 2016
  • Purpose: Due to recent advances in internal fixation techniques, instrumentation and orthopedic implants there is an increasing number of humeral shaft fracture treated operatively. As a consequence, an increased number nonunion after operative fixation are being referred to our center. The aim of this study is to report the common error during osteosynthesis that may have led to nonunion and present a systematic analytical approach for the management of aseptic humeral shaft nonunion. Methods: In between January 2007 to December 2013, 20 patients with humeral shaft nonunion after operative procedure were treated according to our treatment algorithm. We could analysis x-rays of 12 patients from initial treatment to nonunion. In a subgroup of 12 patients the initial operative procedure were analyzed to determine the error that may have caused nonunion. The following questions were used to examine the cases: 1) Was the fracture biology preserved during the procedure? 2) Does the implant construct have enough stability to allow fracture healing? Results: In 19 out of 20 patients have showed radiographic evidence of union on follow up. One patient has to undergo reoperation because of the technical error with bone graft placement but eventually healed. There were 2 cases wherein the treatment algorithm was not followed. All patients had problems with mechanical stability, and in 13 patients had biologic problems. In the analysis of the initial operative fixation, only one of 12 patients had biologic problems. Conclusion: In our analysis, the common preventable error made during operative fixation of humeral shaft fracture is failure to provide adequate stability for bony union to occur. And with these cases we have demonstrated a systematic analytic management approach that may be used to prevent surgeons from reproducing the same fault and reduce the need for bone grafting.

Using a Kirschner wire as an internal splint at nasal fractures accompanied fracture of frontal process of maxilla or perpendicular plate of ethmoid (상악골 전두돌기 골절 및 사골 수직판 골절을 동반한 비골 골절에서 K 강선을 이용한 내고정)

  • Rho, Kyoung Hwan;Yoon, Eul Sik;Yoon, Byung Min;Dhong, Eun Sang
    • Archives of Plastic Surgery
    • /
    • v.36 no.5
    • /
    • pp.623-628
    • /
    • 2009
  • Purpose: In cases where nasal fractures involve frontal process of maxilla or perpendicular plate of ethmoid, 4 - 5 days of nasal packing may not provide sufficient support for avoiding displacement after packing removal. Therefore a single Kirschner - wire(K - wire) is used as an internal splint when nasal fractures involve the above two areas. Methods: Thirty five patients during the last 3 practical years were treated with a K -wire pinning according to the anatomic locations of nasal fractures. We performed a retrospective study using 13 nasal fractures out of total 35 patients. Among 13 cases, 10 patients involved frontal process of maxilla, and 3 patients were diagnosed as bilateral nasal side wall fractures accompanied with fractures of perpendicular plate of ethmoid. One patient of the last three cases had been augmented with dorsal silicone implant long before the trauma. We analyzed the anteroposterior displacement of key stone area and the width between both lateral walls by comparing immediate postoperative radiographs with 2 month follow - ups. To reduce the errors, the same measurements were taken by two different inspectors, and the mean of each inspector's measurements was compared. Patient satisfaction was analyzed using a questionnaire regarding the esthetic and functional outcomes. Results: Ten patients underwent a longitudinal K - wire fixation in submucoperiosteal plane underneath the frontal process of maxilla. And three patients underwent a transverse K - wire fixation from the one side of lateral wall to the perpendicular plate of ethmoid and to the other side of lateral wall. The mean postoperative anteroposterior displacement of the key stone area measured by two inspectors were 1.84% and 3.06%; mean narrowing of bony pyramid were 1.33% and 1.48%, respectively. Subjective satisfaction scores regarding the esthetic appearance and the maintenance of nasal shape compared with immediate post - operative state with the long term ones were not different (p>0.05). Conclusion: K - wire pinning after closed reduction is a reliable and useful method for the treatment of nasal fractures involving frontal process of maxilla or perpendicular plate of ethmoid. This is because it achieves longer intranasal support after reduction. This method also leaves conspicuous external scar, and minimal soft - tissue injury.

A Nationwide Analysis Evaluating the Safety of Using Acellular Dermal Matrix with Tissue Expander-Based Breast Reconstruction

  • Jessica Luo;Whitney D. Moss;Giovanna R. Pires;Irfan A. Rhemtulla;Megan Rosales;Gregory J. Stoddard;Jayant P. Agarwal;Alvin C. Kwok
    • Archives of Plastic Surgery
    • /
    • v.49 no.6
    • /
    • pp.716-723
    • /
    • 2022
  • Background In March 2021, the United States Food and Drug Administration (FDA) safety communication cautioned against the use of acellular dermal matrix (ADM) products in breast reconstruction and reiterated that the FDA does not approve ADM use in breast surgery. This study aims to assess the safety of ADM use in breast reconstruction. Methods Women who underwent ADM and non-ADM assisted tissue expander (TE)-based breast reconstruction were identified using the National Surgical Quality Improvement Program database (2012-2019). Trends of ADM use over time, and 30-day outcomes of surgical site infection (SSI), dehiscence, and unplanned reoperation were assessed. Results Of the 49,049 TE-based breast reconstructive cases, 42.4% were ADM assisted and 57.6% non-ADM assisted. From 2012 to 2019, the use of ADM increased from 26.1 to 55.6% (relative risk [RR] =1.10; p < 0.01). Higher rates of SSI (3.9 vs. 3.4%; p = 0.003) and reoperation (7.4 vs. 6.0%; p < 0.001) were seen in the ADM cohort. There was no significant difference seen in dehiscence rates (0.7 vs. 0.7%; p = 0.73). The most common reoperation within 30 days for the ADM group (17.6%) was removal of TE without insertion of implant (current procedural terminology: 11,971). ADM-assisted breast reconstruction was associated with increased relative risk of SSI by 10% (RR = 1.10, confidence interval [CI]: 1.01-1.21; p = 0.03) and reoperation by 15% (RR = 1.15, CI: 1.08-1.23; p < 0.001). Conclusions ADM-assisted breast reconstruction more than doubled from 2012 to 2019. There are statistically higher complication rates of SSI (0.5%) and reoperation (1.4%) with ADM use in TE-based breast reconstruction, suggesting that reconstruction without ADM is safe when comparing immediate postoperative outcomes.

Arthroscopically-Assisted Reduction and Internal Fixation of Intra-Articular Fractures of the Lateral Tibial Plateau (관절면을 침범한 경골 외측 고평부 골절에 대한 관절경을 이용한 정복 및 내고정술)

  • Kim, Juhan;Kim, Dong Hwi;Lim, Jae-Hwan;Jang, Hyunwoong;Kim, Young Wook
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.3
    • /
    • pp.227-236
    • /
    • 2019
  • Purpose: To evaluate the results of tibial lateral plateau fractures using arthroscopic-assisted reduction and internal fixation without cortical window or bone grafts. Materials and Methods: From March 2009 to March 2017, 27 patients with Schatzker type II tibial plateau fractures with articular depression and displacement over 5 mm on a computed tomography (CT) scan, who were treated with arthroscopic reduction and internal fixation and followed-up for at least 18 months, were enrolled in this study. Under arthroscopic guidance, the depressed fracture fragment was reduced using a freer and fixed with 5.0 or 6.5 mm cannulated screws through the inframeniscal portal without a cortical window or bone graft. The clinical and radiological results were evaluated using a Rasmussen system. Second look arthroscopy was performed in thirteen patients during the implant removal operation. Results: All fractures healed completely with a mean union time of 8.7 weeks (range from 8 to 12 weeks). Twenty four patients had good to excellent clinical results and 25 patients had good to excellent radiological results according to the Rasmussen classification. A well-healed articular surface with fibrocartilage was also found in 13 cases with second look arthroscopy. The 8 cases on CT scan at outpatient department follow-up showed bone union without bone grafting. Conclusion: Arthroscopic-assisted fixation of tibial lateral plateau fractures is a useful method without a cortical window or bone graft that produces good clinical results.

Effect of the Number and Location of Implants on the Stress Distribution in Three-unit Fixed Partial Denture: A Three-Dimensional Finite Element Analysis (임플란트 고정성 보철물에서 수와 식립위치 변화에 따른 골과 임플란트에서의 응력분포에 관한 3차원 유한요소법적 연구)

  • Lee, Woo-Hyun;Lim, Jong-Hwa;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.3
    • /
    • pp.221-239
    • /
    • 2010
  • Bone loss may occur depending on the loading conditions. careful treatment planning and prosthetic procedures are very important factors for the proper distribution of stress. Evaluate the stress distributions according to numbers and location of implants in three-unit fixed partial dentures. A mandible missing the right second premolar, first molar and second molar was modeled. Using the CT data. we modeled a mandible with a width of 15mm, a height of 20mm and a length of 30mm, 2mm-thickness cortical bone covering cancellous bone mallow. An internal type implant and A solid type abutment was used. A model with 3 implants placed in a straight line, offset 1.5 mm buccally, offset 1.5 mm lingually and another model with 3 implants offset in the opposite way were prepared. And models with 2 implants were both end support models, a mesial cantilever model and a distal cantilever model. Three types of loading was applied; a case where 155 N was applied solely on the second premolar, a case where 206 N was applied solely on the second molar and a case where 155 N was applied on the first premolar and 206 N was applied on the first and second molar. For all the cases, inclined loads of 30 degrees were applied on the buccal cusps and vertical loads were applied on the central fossas of the teeth. Finite element analysis was carried out for each case to find out the stress distribution on bones and implants. This study has shown that prostheses with more implants caused lower stress on bones and implants, no matter what kind of load was applied. Furthermore, it was found out that inclined loads applied on implants had worse effects than vertical loads. Therefore, it is believed that these results should be considered when placing implants in the future.

Periodontal inflamed surface area as a novel numerical variable describing periodontal conditions

  • Park, Shin-Young;Ahn, Soyeon;Lee, Jung-Tae;Yun, Pil-Young;Lee, Yun Jong;Lee, Joo Youn;Song, Yeong Wook;Chang, Yoon-Seok;Lee, Hyo-Jung
    • Journal of Periodontal and Implant Science
    • /
    • v.47 no.5
    • /
    • pp.328-338
    • /
    • 2017
  • Purpose: Chronic periodontitis is an inflammatory disease induced by pathogenic bacterial accumulation. A novel index, the periodontal inflamed surface area (PISA), represents the sum of the periodontal pocket depth of bleeding on probing (BOP)-positive sites. It is advantageous for data processing and analysis because it can be treated as a continuous variable to quantify periodontal inflammation. In the present study, we evaluated correlations between PISA and periodontal classifications, and examined PISA as an index integrating the discrete conventional periodontal indexes. Methods: This study was a cross-sectional subgroup analysis of data from a prospective cohort study investigating the association between chronic periodontitis and the clinical features of ankylosing spondylitis. Data from 84 patients without systemic diseases (the control group in the previous study) were analyzed in the present study. Results: PISA values were positively correlated with conventional periodontal classifications (Spearman correlation coefficient=0.52; P<0.01) and with periodontal indexes, such as BOP and the plaque index (PI) (r=0.94; P<0.01 and r=0.60; P<0.01, respectively; Pearson correlation test). Porphyromonas gingivalis expression and the presence of serum P. gingivalis antibodies were significant factors affecting PISA values in a simple linear regression analysis, together with periodontal classification, PI, bleeding index, and smoking, but not in the multivariate analysis. In the multivariate linear regression analysis, PISA values were positively correlated with the quantity of current smoking, PI, and severity of periodontal disease. Conclusions: PISA integrates multiple periodontal indexes, such as probing pocket depth, BOP, and PI into a numerical variable. PISA is advantageous for quantifying periodontal inflammation and plaque accumulation.

The Clinical Study of the Supracondylar Fracture of the Femur (대퇴골 과상부 골절 및 치료에 대한 임상적 고찰)

  • Ahn, Jong-Chul;Kim, Se-Dong;Ahn, Myun-Whan;Seo, Jae-Sung;Lee, Dong-Chul;Lee, Young-Joo
    • Journal of Yeungnam Medical Science
    • /
    • v.10 no.1
    • /
    • pp.197-211
    • /
    • 1993
  • Recently, the Supracondyle fracture of the femur is so severe and comminuted that it is difficult to treat open reduction and rigid fixation sufficiently due to violent traffic accident and external forces. The associated injuries are accompanied variously. So complications of the supracondyle fractures including joint stiffness, delayed union, infection are serious. However development of internal implant and operation skill result in relatively satisfactory function than conservative management. The authors reviewed 20 cases of the supracondyle fracture of the femur treated at Yeungnam University Hospital from 1989, Dec. To 1992, Jan. The results were as follows : 1. The male was common(70%). The 2nd-4th decade was most(87%). 2. The most common cause of injuries was traffic accident. The rate of open fracture was 35%, most of it was traffic accident. 3. According to the ASIF group classification. 4 cases were type A, 4 in type B, 12 in type C (10 in type $C_2$&$C_3$). 4. Accompanied injuries included multiple fractures in 9 cases and femoral artery injury in 1 case. 5. Among the 20 cases, conservative treatment was done in 5 cases and operative treatment was done in 15 cases. 6. Functional results (by Schatzker criteria) were as follows. The satisfactory results were achieved in 40% of cases in conservative treatment and 67% in operative treatment. 7. The average time of partial weight bearing was 15 weeks. 8. Complications were knee stiffness in 6 cases and 4 in delayed union.

  • PDF