• Title/Summary/Keyword: Internal Fracture Fixation

Search Result 320, Processing Time 0.021 seconds

The Subclavian Artery Thrombosis after Open Reduction and Internal Fixation of Clavicular Fracture - A Case Report - (쇄골 골절의 관혈적 정복 및 내 고정술 후 발생한 쇄골하 동맥의 혈전증 - 증례 보고 -)

  • Moon, Eun-Sun;Kim, Myung-Sun;Jeong, Kwang-Cheul;Lim, Keun-Young
    • Clinics in Shoulder and Elbow
    • /
    • v.9 no.2
    • /
    • pp.211-215
    • /
    • 2006
  • Reported in this article is a case report of a patients who developed limb threatening ischemia as a consequence of a subclavian artery thrombosis resulting from screws. The subclavian artery thrombosis after open reduction and internal fixation of clavicle fracture, when it occurs, should be treated promptly by plate removal and claviculectomy. It can be prevented by placing screws in locations away from the underlying neurovascular structures.

Open reduction and internal fixation of mandibular fracture in an 11-month-old infant: a case report

  • Kim, Tae-Wan;Seo, Eun-Woo;Song, Seung-Il
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.39 no.2
    • /
    • pp.90-93
    • /
    • 2013
  • Mandibular fractures in infants are rare. This case report describes management of a mandibular fracture in an 11-month-old infant using a microplate and screws with open reduction. The surgical treatment was successful. Because the bone fragments were displaced and only the primary incisors had erupted, conservative treatment, such as an acrylic splint and circummandibular wiring, was not recommended. Nine weeks after surgery, the microplate was removed. The results showed complete clinical and radiological bone healing with normal eruption of deciduous teeth.

Orthogonal versus Parallel Plating for Distal Humeral Fractures

  • Moon, Jun-Gyu;Lee, Ji-Ho
    • Clinics in Shoulder and Elbow
    • /
    • v.18 no.2
    • /
    • pp.105-112
    • /
    • 2015
  • In orthopedic trauma surgery, treatment of intraarticular distal humerus fractures is a challenge. With development of implants and biomechanical studies, surgical strategies with recommendations including preoperative computed tomography images, proper approaches and open reduction and internal fixation with dual plates have emerged. In addition, as an effort to provide stable fixation to permit early elbow motion, different methods of internal fixation, particularly plate configuration, have evolved. Using dual plates, either oriented parallel to each other or orthogonal, stable fixation has been achieved and satisfactory clinical outcomes have been reported. With rationales and advantages/disadvantages of each plate configuration, both techniques are selected according to surgeons' preference, and, in specific cases, one could be preferred over another. The key to successful fixation by either technique is obtaining anatomical reduction with restoration of two stable columns of the distal humerus.

Treatment of Metacarpal Bone Fracture Using Biodegradable Plates and Screws (흡수성 고정판과 나사를 이용한 중수골 골절의 치료)

  • Cho, Jeong-Mok;Eun, Seok-Chan;Baek, Rong-Min
    • Archives of Plastic Surgery
    • /
    • v.38 no.4
    • /
    • pp.458-464
    • /
    • 2011
  • Purpose: Metacarpal fractures are common hand injury that may require operative intervention to ensure adequate reduction and stabilization. Traditionally, titanium miniplate was used for rigid fixation of bone fractures. However, the use of permanent plate lends itself to multiple complications such as infection, exposure of the hardware, tendon adhesions, tendon rupture, prolonged pain, bony atrophy and osteoporosis (stress shielding), metal sensitization, and palpation under the skin. This study evaluated the usefulness and stability of biodegradable plates and screws for treatment of metacarpal bone fractures. Methods: There was 17 patients who had surgery for metacarpal bone fracture from April 2007 to June 2010. All patients had open reduction and internal fixation. We used absorbable plates and screws (Inion CPS$^{(R)}$) for internal fixation. Postoperative results were assessed with x-ray. Stability of plates and screws, healing process and its complications were observed by clinical and radiographic assessment. Results: All patients were successfully reduced of bone fracture, and fixations with absorbable plates and screws were stable. The mean follow up period was 7.1 months. 2 patients complained postoperative pain, but they were relieved with analgesics. All patients experienced transient stiffness, but they were relieved with active assistive range of motion after removal of splint. No patients suffered complications which could be occurred by using metallic plate. Conclusion: There was no critical complications such as re-fracture or nonunion among patients. No patients suffered side effects related with metallic implants. Biodegradable implants can offer clinically stable and attractive alternative to metallic implants to stabilize metacarpal bone fractures in the hand.

Additional fixation using a metal plate with bioresorbable screws and wires for robinson type 2B clavicle fracture

  • Shin, Woo Jin;Chung, Young Woo;Kim, Seon Do;An, Ki-Yong
    • Clinics in Shoulder and Elbow
    • /
    • v.23 no.4
    • /
    • pp.198-202
    • /
    • 2020
  • Simple clavicle fractures can achieve satisfactory results through conservative treatment, and the less frequency of nonunion. Non-union or malunion can occur in displaced clavicle fractures or comminuted shaft fractures. Treatment of displaced comminuted clavicle shaft fractures is performed by holding together the free fragments with interfragmentary screws or wires and fixing them to the clavicle with a plate. Therefore, we performed interfragmentary fixation using open reduction and internal fixation with bioresorbable screws (Mg-Ca alloy, Resomet bioresorbable bone screw; U&I Corp.) and bioresorbable wires (Mg-Ca alloy, Resomet bioresorbable K-wire and pin, U&I Corp.) for displaced comminuted clavicle fractures (Robinson type 2B) and additionally used a metal plate. We expected decreased irritation and infection due to absorption after surgery. We report four cases that were treated in this way.

TREATMENT OF MANDIBLE FRACTURES USING BIOABSORBABLE PLATES: PRELIMINARY STUDY (생흡수성판을 이용한 하악골 골절의 치료 : 일차보고)

  • Kim, Young-Kyun;Kim, Su-Gwan
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.27 no.6
    • /
    • pp.570-575
    • /
    • 2001
  • This study evaluated the short-term outcome of treating fractures of the mandible with bioabsorbable plates. Thirty-four fractures of the mandible in 27 patients were treated by open reduction and internal fixation using bioabsorbable plates and 2.4-mm, 2.0-mm, and 1.5-mm pre-tapped screws. The duration of intermaxillary fixation ranged from 0 to 23 days, with a mean of 5.3 days. Patients were evaluated for complications during the follow-up period, which ranged from 2 to 18 months. Five patients(18.5%) experienced complications. These included infection (four patients), and premature occlusal contact(one patient). Except for one case, all complications were minor and adequately managed with incision and drainage, elastic traction, and medication. Delayed infection (osteomyelitis) developed in a symphysis fracture and was treated by saucerization and antibiotics. The fracture line subsequently showed complete consolidation. Bioabsorbable plates can be selectively used for internal fixation in mandibular fractures with the advantage that they do not need to be removed.

  • PDF

Mini-T Plate Fixation for Neer Type II Distal Clavicle Fracture (Neer 분류 제 2형 원위부 쇄골 골절의 mini-T형 금속판 고정)

  • Yum, Jae-Kwang;Lee, Sang-Lim;Ra, Ho-Jong
    • Clinics in Shoulder and Elbow
    • /
    • v.12 no.1
    • /
    • pp.1-6
    • /
    • 2009
  • Purpose: To evaluate and report the clinical and radiological outcomes of open reduction and internal fixation with a mini-T plate for unstable distal clavicle fractures. Materials and Methods: From December 2004 to July 2007, fifteen patients who had a fracture of the distal clavicle (Neer type II fracture) were treated with an open reduction and internal fixation using a mini-T plate. They were followed up for a minimum of one year and the clinical and radiological results were analyzed. Results: The average time to fracture union was 3.1(3~4) months. There were no complications, such as deep infection or fixation loss. The mean ASES score was 97 points (85~100points) at the last follow up period, and 14 patients had a full range of motion of the shoulder. Conclusion: Open reduction and internal fixation with a mini-T plate for unstable distal clavicle fracture is a good surgical method with good clinical and radiological results.

Arthroscopic Fixation for Avulsion Fracture of the Posterior Cruciate Ligament(Cases Report) (후방십자인대 견열 골절의 관절경적 정복술(증례 보고))

  • Kim, Kyung Taek;Sohn, Sung Keun;Yang, Sung Wook
    • Journal of the Korean Arthroscopy Society
    • /
    • v.2 no.2
    • /
    • pp.173-176
    • /
    • 1998
  • Isolated posterior cruciate ligament injuries are rare and their management is controversial. But, there is general concept that a bony avulsion of posterior cruciate ligament should be repaired. The treatments for the bony avulsion of posterior cruciate ligament were conservative treatment, open reduction and internal fixation and arthroscopic fixation. We report 2 cases of posterior cruciate ligament avulsion fractures, which were arthroscopically reduced and stabilized with cannulated screws and Kirschner wires, and introduce the arthroscopic fixation technique.

  • PDF

Long Bone Fractures in Raptors: 28 cases (2004-2007)

  • Yoon, Hun-Young;Fox, Derek B.;Jeong, Soon-Wuk
    • Journal of Veterinary Clinics
    • /
    • v.25 no.3
    • /
    • pp.215-217
    • /
    • 2008
  • Medical records from the Veterinary Medical Teaching Hospital of the University of Missouri-Columbia from 2004 to 2007 were available for 28 raptors that underwent long bone fracture repair. There were 14 owls, 10 hawks, 2 vultures, 1 eagle, and 1 falcon. Mean body weight was 780 g (ranged from 150 to 1400 g) for 14 owls; 650 g (ranged from 150 to 1270 g) for 10 hawks; 1760 g (ranged from 1520 to 2000 g) for 2 vultures; 5000 g for 1 eagle; and 130 g for 1 falcon. Of all 28 fracture cases, 11 cases (39%) and 1 case (3%) were related to hit-by-car and shooting respectively. Physical examination revealed dehydration in 18 raptors (64%) and lethargy in 12 raptors (42%). Forty one long bone fractures were included in 28 cases. The radiographs revealed 13 ulnar fractures (32%), 12 humeral fractures (30%), 10 radial fractures (25%), 4 tibiotarsal fractures (9%), 1 femoral fracture (2%), and 1 fibular fracture (2%). External skeletal fixation using polymethylmethacrylate (PMMA) combined with intramedullary fixation was used in 19 long bone fractures (46%). Intramedullary fixation using intramedullary Kirschner pin was used in 16 long bone fractures (39%). No surgical treatment was performed in 6 long bone fractures (15%). This study reported that many of raptors presented dehydration and lethargy when admitted for treatment. Therefore, proper hydration and nutrition are critical pre-surgical requirements. In addition, combination of internal fixation and external skeletal fixation using PMMA might be better option to treat raptors with comminuted fracture that results from mostly trauma of hit-by-car.

THE LITERACTURE REVIEW AND CLINICAL EVALUATION OF INTRAORAL APPROACH FOR SUBCONDYLAR FRACTURE (하악 과두하 골절시 구강내 접근의 문헌 고찰과 임상 연구)

  • Seo, Hyun-Soo;Hong, Soon-Min;Yoo, Seung-Eun;Park, Jun-Woo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.34 no.6
    • /
    • pp.644-648
    • /
    • 2008
  • Purpose: The aim of this study was to investigate the clinical cases of subcondylar fracture with intraoral approach. Material and Method: Fifteen patients with unilateral subcondylar fracture were treated in the department of oral and maxillofacial surgery, Kangdong Sacred Heart Hospital, College of Medicine, Hallym University between 2006 and 2007. Each patients was examined by computed tomography(CT) and panorama. 3D-CT taken when fractured segment was displaced and comminuted. Patients was done intermaxillary fixation to occlusal stability and prevent displacement of fractured segment before general operation. Open reduction and internal fixation(ORIF) accomplished under general anesthesia and used to intraoral approach. We examinated the state of occlusion, maximum opening. Evaluation of the state of occlusion was divided in patient`s subjective evaluation that compare pre-traumatic occlusion with postoperative occlusion, and estimator`s objective evaluation that use articulating paper. Examination was done at 2 weeks, 1, 3, 6 month postoperative by follow up. Result: The ORIF through intraoral approach was good in all patients. In the state of occlusion, all patients recovered pre-traumatic occlusion in 6 month postoperation. Maximum opening was gradually increased. In 3 month postoperative, maximum opening was excessed 40mm. Conclusion: Our study indicate that the intraoral approach is a good technique for subcondylar fracture. Intraoral approach prevent complication that facial nerve damage, scar formation caused by extraoral approach. So, we recommend intraoral approach when subcondylar fracture.