• Title/Summary/Keyword: Internal Fracture Fixation

Search Result 320, Processing Time 0.022 seconds

The Role of Minimally Invasive Plate Osteosynthesis in Rib Fixation: A Review

  • Bemelman, Michael;van Baal, Mark;Yuan, Jian Zhang;Leenen, Luke
    • Journal of Chest Surgery
    • /
    • v.49 no.1
    • /
    • pp.1-8
    • /
    • 2016
  • More than a century ago, the first scientific report was published about fracture fixation with plates. During the 1950's, open reduction and plate fixation for fractures were standardized by the founders of Arbeitsgemeinschaft $f{\ddot{u}}r$ osteosynthesefragen/Association for the Study of Internal Fixation. Since the introduction of plate fixation for fractures, several plates and screws have been developed, all with their own characteristics. To accomplice more fracture stability, it was thought the bigger the plate, the better. The counter side was a compromised blood supply of the bone, often resulting in bone necrosis and ultimately delayed or non-union. With the search and development of new materials and techniques for fracture fixation, less invasive procedures have become increasingly popular. This resulted in the minimally invasive plate osteosynthesis (MIPO) technique for fracture fixation. With the MIPO technique, procedures could be performed with smaller incisions and thus with less soft tissue damage and a better preserved blood supply. The last 5 years rib fixation has become increasingly popular, rising evidence has becomeavailable suggesting that surgical rib fixation improves outcome of patients with a flail chest or isolated rib fractures. Many surgical approaches for rib fixation have been described in the old literature, however, most of these techniques are obscure nowadays. Currently mostly large incisions with considerable surgical insult are used to stabilize rib fractures. We think that MIPO deserves a place in the surgical treatment of rib fractures. We present the aspects of diagnosis, preoperative planning and operative techniques in regard to MIPO rib fixation.

Fixation of Nasal Bone Fracture with Carved Merocel® (Carved Merocel®을 이용한 비골골절의 고정)

  • Kong, Jung Sik;Jung, Jae A;Kang, So Ra;Kim, Yang Woo;Jeon, Young Woo
    • Archives of Craniofacial Surgery
    • /
    • v.12 no.2
    • /
    • pp.93-96
    • /
    • 2011
  • Purpose: In most cases of nasal bone fracture, closed reduction with internal or external splint fixation approach is selected. However, because of indiscriminate insertion of the internal splint without considering of anatomical difference or deformity, insufficient fixation happens frequently that need additional fixation. Therefore, we suggest a new method for providing adequate support in reduced nasal bone by carving $Merocel^{(R)}$ that is fixed for the anatomical structure. Method: Closed reduction and internal fixation with carved $Merocel^{(R)}$ was performed in 15 nasal bone fracture patients from March, 2010 to July, 2010. Each patient was evaluated by physical examination, facial photographic check, simple X-ray, and computerized tomography. On the first day post-operation, location of packing and amount of reduction were checked by follow up X-ray and computerized tomography. In addition, patients' symptoms were evaluated. During the 3-month post-op follow up at out-patient clinic, operator, 2 doctors in training and one assistant performed the objective evaluations by physical examination on nasal dorsal hump, nasal deviation, nasal depression, nasal breath difficulty, and nasal airway obstruction. A survey of subjective patients' satisfaction in 4-stages was also performed. Results: The results of follow-up computerized tomography of the 15 patients revealed that 11 patients had good reduced state. Three patients with combined maxillary frontal process fracture had over reductions. A survey performed on the first day post-operation showed that 14 of 15 patients answered that their current symptoms were more than tolerable. At the 3-month follow-up physical exam, one case had a dorsal hump. However, there were no nasal deviations, nasal depressions, nasal breath difficulties, or nasal airway obstructions. Twelve of the 15 patients answered more than moderate on the 3-month survey. Conclusion: Intranasal packing after carving the $Merocel^{(R)}$ considering anatomical structure is a new effective method to promote proper-reduction, maintain stability, and minimize patients' symptoms by addition of a simple procedure.

Modified high-submandibular appraoch for open reduction and internal fixation of condylar fracture: case series report

  • Lee, Sung-Jae;Chun, Young-Joon;Lee, Seung-Jun;Jun, Sang-Ho;Song, In-Seok
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.48 no.5
    • /
    • pp.267-276
    • /
    • 2022
  • Objectives: Recently a modified high-submandibular approach (HSMA) has been introduced for treatment of condylar fracture. This approach involves an incision line close to the mandibular angle and transmasseteric transection, leading to a low incidence of facial palsy and allowing good visualization of the condyle area, especially the condylar neck and subcondyle positions. This study reports several cases managed with this modified HSMA technique for treating condylar fractures. Materials and Methods: Six cases of condylar fractures treated with modified HSMA technique were reviewed. Results: Three unilateral subcondylar fracture, 1 bilateral subcondylar fracture, 1 unilateral condylar neck fracture, 1 unlateral simultaneous condylar neck and subcondylar fracture cases were reviewed. All the cases were successfully treated without any major complication. Conclusion: Reduction, fixation, and osteosynthesis of condylar fractures via the modified HSMA technique enabled effective and stable treatment outcomes. Therefore, the described approach can be used especially for subcondylar and condylar neck fractures with minimal complications.

Treatment of extensive comminuted mandibular fracture between both mandibular angles with bilateral condylar fractures using a reconstruction plate: a case report

  • Lee, Kwonwoo;Yoon, Kyuho;Park, Kwan-Soo;Cheong, Jeongkwon;Shin, Jaemyung;Bae, Jungho;Ko, Inchan;Park, Hyungkoo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.40 no.3
    • /
    • pp.135-139
    • /
    • 2014
  • This following case report describes the open reduction, internal fixation and the reconstruction of an extensive comminuted mandibular fracture with bilateral condylar fractures in a 19-year-old male patient with an intellectual disability and autistic disorder. He suffered fall trauma, resulting in shattered bony fragments of the alveolus and mandibular body between both mandibular rami, the fracture of both condyles and the avulsion or dislocation of every posterior tooth of the mandible. The patient underwent open reduction and internal fixation between both mandibular rami using a reconstruction plate, open reduction and internal fixation of the shattered fragments using miniplates and screws, and the closed reduction of the bilateral condylar fractures.

Tibial Fracture Repair in a Black Gibbon (Hylobates concolor) (긴팔원숭이에서 발생한 경골 골절의 외과적 정복 1례)

  • Yoon, Hun-Young;Lee, Bo-Ra;Jeong, Soon-Wuk
    • Journal of Veterinary Clinics
    • /
    • v.26 no.6
    • /
    • pp.644-646
    • /
    • 2009
  • A 5-year-old intact male black gibbon (Hylobates concolor) was referred for evaluation of the right pelvic limb lameness following a fight against other black gibbons. Fractures of the right tibia and fibula were suspected on physical examination and palpation of the right pelvic limb, but no other injuries or abnormalities were detected. While the black gibbon was sedated, pelvic limb radiographs were taken, which revealed diaphyseal oblique fractures of the right tibia and fibula. Open reduction of the fractures was performed. The tibial fracture was repaired by use of an internal fixation technique that included a tubular dynamic compression plate and cortical screws secured along the craniomedial aspect of the tibia. There were no complications during the postoperative rehabilitation period. At 9 weeks, radiographs revealed that bridging callus was well formed over the cortices of the tibial and fibular fracture area. The cast was removed 9 weeks after surgery. The black gibbon exhibited no evidence of lameness and was released back into the group. Presently, there are no published reports of internal fracture fixation in a black gibbon where a tubular dynamic compression plate and cortical screws provided excellent stabilization of the tibia and complete fracture healing allowing normal ambulation.

Study of the Plating Methods in the Experimental Model of Mandibular Subcondyle Fracture (하악골 과두하부 골절 실험모델에서 견고정을 위한 플레이트 고정방법 연구)

  • Lee, Won;Kang, Dong Hee
    • Archives of Craniofacial Surgery
    • /
    • v.12 no.1
    • /
    • pp.12-16
    • /
    • 2011
  • Purpose: This study examined the biomechanical stability of four different plating techniques in the experimental model of mandibular subcondyle fracture. Methods: Twenty standardized bovine tibia bone samples ($7{\times}1.5{\times}1.0cm$) were used for this study. Each of the four sets of tibia bone was cut to mimic a perpendicular subcondyle fracture in the center area. The osteotomized tibia bone was fixed using one of four different fixation groups (A,B,C,D). The fixation systems included single 2.0 mm 4 hole mini adaption plate (A), single 2.0 mm 4 hole dynamic compression miniplate (B), double fixation with 2.0 mm 4 hole mini adaption plate (C), double fixation with a 2.0 mm 4 hole mini adaption plate and 2.0 mm 4 hole dynamic compression miniplate (D). A bending force was applied to the experimental model using a pressure machine (858 table top system, $MTS^{(R)}$) until failure occurred. The load for permanent deformation, maximum load of failure were measured in the load displacement curve with the chart recorder. Results: Double fixation with a 2.0 mm 4 hole mini adaption plate and a 2.0 mm 4 hole dynamic compression miniplate (D) applied to the anterior and posterior regions of the subcondyle experimental model showed the highest load to failure. Conclusion: From this study, double fixation with an adaption plate and dynamic compression miniplate fixation technique produced the greatest biomechanical stability. This technique may be considered a useful means of fixation to reduce the postoperative internal maxillary fixation period and achieve early mobility of the jaw.

Botulinum toxin as adjunct therapy in surgical management of a periprosthetic scapular spine fracture: a case report

  • Alex E. White;Christopher M. Brusalis;David S. Wellman;Samuel A. Taylor
    • Clinics in Shoulder and Elbow
    • /
    • v.26 no.1
    • /
    • pp.87-92
    • /
    • 2023
  • Six months after undergoing reverse shoulder arthroplasty (RSA) a 73-year-old woman sustained a periprosthetic scapular spine fracture following a fall. She was treated with open reduction and internal fixation (ORIF), followed by botulinum toxin injection into the deltoid muscle to temporarily minimize strain at the fracture. Fracture union was achieved by 3 months, with excellent clinical function more than 1 year following fracture fixation and full resolution of deltoid function. Scapular spine fracture following RSA can be treated with ORIF and temporary deltoid paralysis using botulinum toxin in the immediate postoperative period to safely support fracture healing.

Mini-open Treatment Using Plate of Clavicle Mid-shaft Fractures

  • Park, Yong-Geun;Kang, Hyunseong;Kim, Shinil;Bae, Jong-Hwan;Choi, Sungwook
    • Clinics in Shoulder and Elbow
    • /
    • v.20 no.1
    • /
    • pp.37-41
    • /
    • 2017
  • Background: Increased frequency of comminuted clavicle mid-shaft fractures and importance of functional satisfaction through early joint exercise has resulted in higher emphasis on surgical treatments. This study aimed to evaluate the clinical radiological results of treatment of clavicle mid-shaft fractures by open reduction and internal fixation using a plate with a small incision. Methods: The subjects of this study were 80 clavicle mid-shaft fracture cases treated with internal fixation using a plate from October 2010 to July 2014. Clavicle mid-shaft fractures were internally fixated using anatomical plates or locking compression plates. Achievement of bone union, union period, and clavicle length shortening were evaluated radiologically, and clinical assessment was done by using Constant and University of California at Los Angeles (UCLA) scores. Results: All 80 cases were confirmed to have achieved bone union through radiographs with an average union period of 10.9 weeks (range: 7-18 weeks). The average clavicle length of shortening in the affected side was 1.8 mm (range: 0-17 mm). The average UCLA score and Constant score were 33.6 (range: 25-35) and 92.5 (range: 65-100), respectively. Regarding complications, four cases reported skin irritation by metal plates, and one case reported a screw insertion site fracture due to minor trauma history. Conclusions: We were able to induce successful bone union and obtain clinically satisfactory results in displaced mid-shaft fractures of the clavicle without major complications such as nonunion through treatment of internal fixation using a plate.

Treatment of Intra-articular Calcaneal Fracture with Open Reduction and Internal Fixation (관혈적 정복 및 내고정을 이용한 관절내 종골 골절의 치료)

  • Choi, Jun-Won;Choi, Joon-Cheol;Lee, Young-Sang;Na, Hwa-Yeop;Kim, Woo-Sung;Han, Sang-Ho
    • Journal of Korean Foot and Ankle Society
    • /
    • v.11 no.2
    • /
    • pp.226-231
    • /
    • 2007
  • Purpose: To evaluate the clinical outcomes and radiographic results of open reduction and internal fixation for intraarticular calcaneal fractures. Materials and Methods: We reviewed 20 cases of calcaneal fractures managed with open reduction and internal fixation from March 2003 to January 2005. We used the computed tomographic classification system proposed by Sanders et al to classify these fractures. Preoperative and postoperative Bohler's angle, heel height (calcaneal facet height) and calcaneal length, calcaneal width were measured. The Creighton-Nebraska Health Foundation Assessment score was used for clinical evaluation. Results: There were 12 cases of type II fractures, 5 of type III fractures and 3 of type IV fractures. The mean clinical score was 84.3 for type II, 82.6 for type III and 56.1 for type IV. The mean preoperative $B{\ddot{o}}hler$ angle was $6.1^{\circ}$ and final was $22.8^{\circ}$. The mean preoperative calcaneal facet height was 76.6 mm and final was 80.3 mm (The mean calcaneal facet height was changed from preop 76.6 mm to postop 80.3 mm). The mean preoperative calcaneal length was 88.2 mm and final was 92.6 mm. The mean preoperative width was 38.1 mm and final was 35.6 mm. Conclusion: Open reduction and internal fixation showed good results for type II and III fractures, but for type IV fractures the clinical result was significantly worse than the other types. However, type IV fractures still had restoration of (should be restored in) $B{\ddot{o}}hler's$ angle, calcaneal facet height, calcaneal length and width which may be helpful in later subtalar fusion.

  • PDF

Open Reduction and Internal Fixation of Displaced Intra-Articular Fractures of the Glenoid (전위된 견갑골 관절내 골절의 관혈적 정복 및 내고정술)

  • Kim Seung Key;Park Jong Beom;Choi Woo-Sung;Kwon Young-Jeong;Chang Han
    • Clinics in Shoulder and Elbow
    • /
    • v.1 no.2
    • /
    • pp.230-235
    • /
    • 1998
  • Fractures of the scapula are relatively uncommon injuries and treatment in the vast majority of cases remains nonsurgical and the results have been quite satisfactory. But the scapular fracture itself may be neglected because of its high incidence of many kinds of associated injuries so its delayed treatment sometimes gives bad and unpredictable results. Although open reduction and internal fixation has been accepted as the treatment of choice for displaced intra-articular fractures in many anatomical regions, there has been no definite treatment principles of surgical indications and approaches in the glenohumeral joint. At our institution, II displaced intra-articular fractures of the glenohumeral joint were treated with open reduction and internal fixation from March 1993 to February 1997. This paper reports the results of treating 11 displaced intra­articular fractures of the glenoid by open reduction and internal fixation. There were 10 men and one woman and the fractures were classified according to Ideberg : Type Ⅰa(4), Type Ⅱ(3), Type Ⅲ(1), Type IV(1), Type Va(1), and Type Vc(1).

  • PDF