• Title/Summary/Keyword: Internal Fracture Fixation

Search Result 328, Processing Time 0.03 seconds

Anterior Compartment Syndrome after Surgery of Bosworth Fracture-Dislocation of the Ankle - A Case Report - (족관절의 Bosworth 골절-탈구 발생한 전방 구획 증후군 -증례 보고-)

  • Chung, Hyung-Jin;Park, Se-Jin;Choi, Yun-Seok
    • Journal of Korean Foot and Ankle Society
    • /
    • v.8 no.2
    • /
    • pp.221-223
    • /
    • 2004
  • Bosworth fracture-dislocation of ankle is very rare, occurred by eversion and external rotation force. It is known as irreducible fracture by closed method. Also, compartment syndrome after ankle fracture are exceedingly rare. There are only a few reported cases of compartment syndrome after ankle fracture and compartment syndrome are involved commonly deep posterior compartment. We present a case in which a patient had a Bosworth fracturedislocation of the ankle underwent open reduction with internal fixation and subsequently occurred an anterior compartment syndrome of the leg.

  • PDF

Ruptured Posterior Tibial Tendon in Closed Ankle Fracture - A Case Report - (폐쇄성 족관절 골절에 동반된 후경골건 파열 - 1예 보고 -)

  • Choi, Joong-Geun;Woo, Seung-Han
    • Journal of Korean Foot and Ankle Society
    • /
    • v.6 no.1
    • /
    • pp.92-95
    • /
    • 2002
  • Traumatic ruptures of tibialis posterior tendon are much less common and consequently have received little attention. A tibialis posterior tendon rupture associated with a closed medial malleolar fracture occured in a 32 years old man due to slip down. The tendon rupture was not diagnosed before surgery but was recognized at the time of open operation. The treatment was open reduction and internal fixation at the bony fragments with primary repair of the tendon. This tendon injury, although rare, should be considered in the management of ankle fracture because the tendon rupture could easily have been overlooked and failure to recognize this at the time of injury may result in poor long - term ankle function despite a well- healed fracture.

  • PDF

Application of Monitored Anesthesia Care Using Dexmedetomidine to Common Oral and Maxillofacial Trauma Cases

  • Lee, Deok-Won;Shin, Min Cheol;Hong, Sung ok
    • Journal of Korean Dental Science
    • /
    • v.10 no.2
    • /
    • pp.82-86
    • /
    • 2017
  • Oral and maxillofacial surgery (OMFS) trauma cases are commonly treated under general anesthesia. The purpose of this case report is to introduce an alternative method of anesthesia in patients who refuse general anesthesia. A combination of dexmedetomidine and ketamine for sedation anesthesia in 3 frequent fracture types in the field of OMFS-Le Fort I fracture, mandibular fracture, and alveolar bone fracture-was used. Dexmedetomidine as the single agent has not shown stable success rates for invasive procedures. To overcome some of the pitfalls with dexmedetomidine, combination sedation using ketamine was performed. Visual analogue scale scores were recorded postoperatively. Dexmedetomidine combined with ketamine administration provided safe and effective sedation and anxiolysis for surgical reduction and internal fixation of OMFS fractures. It showed advantages of decreased admission time, reduced expenses, minimal pain, and reduced anesthetic burden for the patient thus ultimately increasing overall satisfaction.

Osteolysis-Related Bioabsorbable Suture Anchor Fixation in a Medial Collateral Ligament Avulsion Fracture during Total Knee Arthroplasty (슬관절 인공관절 치환술 중 발생한 내측 측부 인대 견열 골절에 대해 생흡수성 봉합 나사못을 이용한 고정 후 발생한 골용해)

  • Huh, Jung-Wook;Park, Man-Jun;Hong, Seong-Hwak;Park, Joon-Hyung
    • Journal of the Korean Orthopaedic Association
    • /
    • v.55 no.6
    • /
    • pp.545-549
    • /
    • 2020
  • Although rare, the treatment options for a medial collateral avulsion fracture during total knee arthroplasty (TKA) range from conservative management using a cast and orthosis to internal fixation using metal screws. Bioabsorbable suture anchors have been used to replace metal fixators with distinct advantages, such as biocompatibility, radiolucency, and unnecessary second removal surgery, but complications, such as osteolysis, have been reported. This paper reports a potential risk of an extensive osteolysis-related suture anchor fixation of a medial collateral ligament (MCL) avulsion fracture during TKA in conjunction with a literature review.

Operative Treatment with Anatomically Preshaped Locking Compression Plate in Distal Fibular Fracture (해부학적 잠김 압박 금속판을 이용한 원위 비골 골절의 치료)

  • Chung, Hyung-Jin
    • Journal of Korean Foot and Ankle Society
    • /
    • v.17 no.2
    • /
    • pp.130-135
    • /
    • 2013
  • Purpose: Preshaped Locking compression plate(LCP) has holes with fixed angle between screw and plate and have advantage firm fixation because it has stability of angular and axial deformity. We evaluated usefulness of LCP after open reduction and internal fixation in distal fibular fracture. Materials and Methods: Between December 2011 and May 2012, 23 patients with fracture of distal fibula were followed up at least 12 months underwent open reduction and internal fixation with LCP. There were 15 males and 8 females with a mean age 39.8(20~69) years. According to Danis-Weber classification, there were 20 cases of type B and 3 cases of type C. There were 13 cases of isolated lateral malleolus fractures, 1 case of bimalleolar fracture, 6 cases of trimalleolar fractures and 3 cases of distal tibia fractures with proximal fibula fracture. Intraoperatively, we assessed whether preshaped LCP fit lateral margin of distal fibula or not and evaluated quality of reduction and postoperative complications. The cases were analyzed by radiological bone union time and clinical results according to the criteria of Meyer Results: Of all cases, complete bone union was achieved and average radiological bone union time was 7.3(6~12) weeks. The clinical results were excellent in 18 cases(78%), good in 5 cases(22%). There were 5 cases of plate with 3 holes, 13 cases of plate with 4 holes, 2 cases of plate with 5 holes, 1 case of plate with 6 holes and 2 cases of plate with 7 holes. The average number of screws at proximal fragement was 2.5 and at distal fragment was 3.5. In 14 cases (60.8 %), we needed re-bending of plate because the distance between plate and lateral cortical margin of distal fibula was more than 5 mm at anteroposterior X-ray after reduction. All cases have anatomical reduction and there were no complications of wound infections. There were no complaint about hardware irritation. Conclusion: At fractures of distal fibula,preshaped LCP had a excellent stability although far cortex was not fixed with screw and bending of plate. And there are less complications of hardware irritation and wound problems. But, Some complement would be needed because there were no complete fitting between precontour of LCP and lateral cortical margin of distal fibula.

Arthroscopic Reduction and Internal Fixation with Cannulated Screw of a Transverse Glenoid Fracture (유경 나사를 이용한 견갑골 관절와 횡골절의 관절경적 정복 밑 내고정)

  • Noh Kyu Cheol;Yoo Jung Han;Kang Ki Man
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.2 no.2
    • /
    • pp.176-180
    • /
    • 2003
  • We describe in this report the accurate reduction of a transverse displaced glenoid fracture through arthroscopic control . We used the lateral and superior (Neviaser portal) portal of the arthroscopic surgery in the shoulder joint for the U 4.0-mm titanium cannulated cancellous screw fixation. The advantages of this treatment are excellent intra-articular visualiBation, decreased soft tissue dissection ,less blood loss, shortened postoperative recovery and early ROM exercise. There(ore, we report the method of operation and the cases .

  • PDF

Operative Treatment of Fractures of the Midshaft Clavicle using Locking Compression Plate (Locking Compression Plate를 이용한 전위성 쇄골 간부 골절의 수술적 치료)

  • Chung, Nam-Sik;Hong, Ki-Do;Ha, Sung-Sik;Park, Sung-Joon;Kang, Jung-Ho;Sim, Jae-Cheon
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.5 no.1
    • /
    • pp.63-68
    • /
    • 2006
  • Purpose: To assess the effectiveness of the Locking compression plate (LCP) after open reduction for the treatment of the displaced clavicular shaft fracture, the clinical and radiologic outcome of the patients who were managed with the LCP for internal fixation after open reduction has been analyzed. Materials and Methods: We reviewed 26 cases with a displaced clavicular shaft fracture treated by internal fixation using Locking compression plate after open reduction between May 2003 and November 2004. The patients were followed up for at least six months period, and final postoperative outcome was evaluated using clinical results based on Kang's criteria, radiologic signs of fusion. Results: All fractures united by an average of 9.3 weeks without delayed union and showed fast recovery of motion fraction and shoulder function. In addition,24 cases without the fractures of proximal humerus recovered to normal range of shoulder notion within 2.9 weeks. Clinically, according to Kang's criteria, the outcome was good or better in 22 patients. The complications included shoulder joint dysfunction in two cases and keloid formation in one case, and no other complications were observed. Conclusion: The internal fixation using LCP for the treatment of displaced clavicular shaft fracture is a safe, reliable method of treatment, with few complications, and offers rapid recovery of shoulder joint function and bone union.

  • PDF

Hook Plate Fixation for Isolated Greater Tuberosity Fractures of the Humerus

  • Lee, Kyoung-Rak;Bae, Ki-Cheor;Yon, Chang-Jin;Cho, Chul-Hyun
    • Clinics in Shoulder and Elbow
    • /
    • v.20 no.4
    • /
    • pp.222-229
    • /
    • 2017
  • Background: The purpose of this study was to investigate the outcomes after fixation using a 3.5-mm locking compression plate (LCP) hook plate for isolated greater tuberosity (GT) fractures of the proximal humerus. Methods: We evaluated the postoperative radiological and clinical outcomes in nine patients who were followed up at least 1 year with isolated GT fractures. Using the deltopectoral approach, we fixed the displaced GT fragments with a 3.5-mm LCP hook plate (Synthes, West Chester, PA, USA). Depending on the fracture patterns, the hook plate was fixed with or without augmentation using either tension suture or suture anchor fixation. Results: All the patient showed successful bone union. The mean time-to-union was 11 weeks. The radiological and clinical outcomes at the final follow-up were generally satisfactory. The mean visual analogue scale for pain, the University of California at Los Angeles score, the American Shoulder and Elbow Surgeons score, and the subjective shoulder value were 1.4, 30.3, 84.3, and 82.2%, respectively. The mean active forward flexion, abduction, external rotation, and internal rotation of the shoulder were $156.7^{\circ}$, $152.2^{\circ}$, $61.1^{\circ}$, and the 10th thoracic vertebral level, respectively. Only one patient presented with a postoperative complication of shoulder stiffness. The patient was treated through arthroscopic capsular release on the 5th postoperative month. Conclusions: We conclude that fixation using 3.5-mm LCP hook plates for isolated GT fractures of the proximal humerus is a useful treatment method that provides satisfactory clinical and radiological outcomes.

Outcomes of open versus closed treatment in the management of mandibular subcondylar fractures

  • Kim, Seong-Yong;Ryu, Jae-Young;Cho, Jin-Yong;Kim, Hyeon-Min
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.40 no.6
    • /
    • pp.297-300
    • /
    • 2014
  • Objectives: To compare the clinical and radiological outcomes after closed reduction (CR) and open reduction and internal fixation (ORIF) in the management of subcondylar fractures. Materials and Methods: Forty-eight patients presenting with subcondylar fracture between January 2010 and March 2013 were evaluated retrospectively. Fifteen patients were treated with CR and 33 patients with ORIF. The clinical and radiologic parameters were evaluated during follow-up (mean, 7.06 months; range, 3 to 36 months). Results: In the CR group, no patients had any problems with regard to the clinical parameters. The average period of maxillomandibular fixation (MMF) was 5.47 days. The preoperative average tangential angulation of the fractured fragment was $3.67^{\circ}$, and loss of ramus height was 2.44 mm. In the ORIF group, no clinical problems were observed, and the average period of MMF was 6.33 days. The preoperative average tangential angulation of the subcondylar fragment was $8.66^{\circ}$, and loss of ramus height was 3.61 mm. Conclusion: CR provided satisfactory clinical results, though ORIF provided more accurate reduction of the fractured fragment. So there is no distinct displacement of fractured fragment, CR should be selected than ORIF because of no need for surgery.

Surgical Treatment of Distal Tibia Fractures (원위 경골 골절의 수술적 치료)

  • Jeong, Jae-Jung;Kang, Do-Jun
    • Journal of Korean Foot and Ankle Society
    • /
    • v.17 no.3
    • /
    • pp.174-181
    • /
    • 2013
  • Distal tibia fractures were mainly caused by high energy trauma and the lower legs were enveloped in poor soft tissue. Therefore, there are many open fractures and concomitant soft tissue injuries in distal tibia fractures. For the restoration of ankle function, the surgical treatment was performed in distal tibia fractures. However, it is difficult to treat the distal tibia fracture surgically. There are many complications in distal tibia fracture due to highly comminuted fracture and poor soft tissue condition. There are many surgical methods for distal tibia fractures, such as, external fixator, intramedulary nailling, open reduction & internal fixation, and minimally invasive plate osteosynthesis. We reviewed the surgical treatments of distal tibia fractures.