• Title/Summary/Keyword: Internal Flow Noise

Search Result 109, Processing Time 0.048 seconds

Flow-induced Instability of Multi-wall Carbon Nanotubes for Various Boundary Conditions (경계조건에 따른 다중벽 탄소나노튜브의 유체유발 불안정성 변화)

  • Yun, Kyung-Jae;Song, Oh-Seop
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.20 no.9
    • /
    • pp.805-815
    • /
    • 2010
  • This paper studies the influence of internal moving fluid and flow-induced structural instability of multi-wall carbon nanotubes conveying fluid. Detailed results are demonstrated for the variation of natural frequencies with flow velocity, and the flow-induced divergence and flutter instability characteristics of multi-wall carbon nanotubes conveying fluid and modelled as a thin-walled beam are investigated. Effects of various boundary conditions, Van der Waals forces, and non-classical transverse shear and rotary inertia are incorporated in this study. The governing equations and three different boundary conditions are derived through Hamilton's principle. Numerical analysis is performed by using extended Galerkin's method which enables us to obtain more exact solutions compared with conventional Galerkin's method. This paper also presents the comparison between the characteristics of single-wall and multi-wall carbon nanotubes considering the effect of van der Waals forces. Variations of critical flow velocity for different boundary conditions of two-wall carbon nanotubes are investigated and pertinent conclusion is outlined.

Optimal Design of Rotor Profile of Internal Gear Pump for Noise Reduction (내접형 기어펌프용 로터의 소음저감을 위한 치형 최적설계)

  • Bae, Jun Ho;Bae, Won Byong;Joo, Ung Tak;Kim, Chul
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.3
    • /
    • pp.295-302
    • /
    • 2014
  • An internal gear pump is required to improve the flow rate and noise. Furthermore, such pumps are durable and small in size. In this study, equations of the rotor shape with multiple profiles (ellipse 1-involute-ellipse 2) were derived, and relevant performance parameters (pressure angle, irregularity, and specific sliding) of the internal gear pump to noise were predicted and compared. Rotor profiles and performance parameters were obtained by a prediction algorithm for theoretical analysis, and the effects between the design parameters and the performance parameters were analyzed. Based on the analysis results of the effects, an optimal design of the rotor profile was proposed, and a noise test of the prototype was performed to evaluate the reliability of the design.

The Effect of Pump Intake Leaning Angle and Flow Rate on the Internal Flow of Pump Sump

  • Lee, Youngbum;Kim, Kyung-Yup;Chen, Zhenmu;Choi, Young-Do
    • The KSFM Journal of Fluid Machinery
    • /
    • v.20 no.1
    • /
    • pp.74-80
    • /
    • 2017
  • Pump sump system or pumping stations are built to draw water from a source such as river and used for irrigation, thermal power plants etc. If pump sump is improperly shaped or sized, air entraining vortices or submerged vortices may develop. This may greatly affect pump operation if vortices grow to an appreciable extent. Moreover, the noise and vibration of the pump can be increased by the remaining of vortices in the pump flow passage. Therefore, the vortices in the pump flow passage have to be reduced for a good performance of pump sump station. In this study, the effect of pump intake leaning angle and flow rate on the pump sump internal flow has been investigated. There are three cases with different leaning angle. Moreover, a pipe type with elbow also has been studied. The flow rate with three classes of air entraining vortices has been examined and investigated by decreasing the water level. The result shows that the air entraining vortices easily occurs at the pump intake with large leaning angle. Moreover, the elbow type of the pump intake easily occurs air entraining vortices at the high flow rate (or velocity) in comparison to other pump intake type.

Effect of Tunnel Entrance Hood on Entry Compression Wave (입구후드가 고속철도 터널입구의 압축파에 미치는 영향)

  • Kim, Heuy-Dong;Kim, Tae-Ho;Kim, Dong-Hyeon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.1
    • /
    • pp.58-68
    • /
    • 1999
  • The entry compression wave, which forms at the entrance of a high-speed railway tunnel, is closely related to the pressure transients in the train/tunnel systems as well as an impulsive noise appearing at the exit of the tunnel. In order to alleviate such undesirable phenomena, some control strategies have been applied to the compression wave propagating inside the tunnel. The objective of the current work is to investigate the effect of tunnel entrance hoods on the entry compression wave at the vicinity of the tunnel entrance. Three types of entrance hoods were tested by the numerical method using the characteristics of method for a wide range of train speeds. The results show that the maximum pressure gradient of compression wave can be considerably reduced by the tunnel entrance hood. Optimum hood shape necessary to reduce the pressure transients and impulsive noise was found to be of an abrupt type hood with its cross-sectional area 2.5 times the tunnel area. It is believed that the current results are highly useful in predicting the effects of entrance hoods and in choosing the shape of proper hood.

A study on the inner flow fields characteristics of the Semi-active muffler (반능동형 머플러 내부의 유동장특성에 관한 연구)

  • Park Kyoung-Suk;Heo Hyung-Seok;Park Se-Jong;Son Sung-Man;Kim Dong-Hyun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.3 s.180
    • /
    • pp.125-131
    • /
    • 2006
  • Recently air pollution has become an important issue. So, as tile number of vehicles increases, the noise pollution has become one of the most serious social issues nowadays. It is a muffler, which is one of the vehicle components. that has the hugest impact on the noise from the vehicle. And it also has a direct influence on the engine performance. So lately the research is proceeding on tile semi-active muffler which can control the back pressure variably by setting up the exhaust variable valve in the baffle to improve its internal structure. The inner parts of muffler which consist of a baffle, pipes and etc. appear to have the complicated turbulence phenomena by the pulsational wave of an unsteady state in the engine and by the structural characteristics of the inner parts. To analyze these phenomena, it is required to have an analysis of its constant quantity and quality. Therefore this study is to analyze with PIV measurement which can analyze the time and space variables, not with the point measurement method like former multi-point anemometer. It is to suggest proper design variables which need to make internal structure of the muffler improve though comparison between the passive type muffler and the semi-active muffler by fabricating a muffler which can be visualized.

Evaluation of Modified Turbo Spin Echo Technique Compared with Double Inversion Recovery Technique in Acquisition of Black Blood Brain Vessel Image

  • Choi, Kwan-Woo;Lee, Ho-Beom;Na, Sa-Ra;Son, Soon-Yong
    • Journal of Magnetics
    • /
    • v.21 no.1
    • /
    • pp.148-152
    • /
    • 2016
  • The main goal was to evaluate effectiveness of a modified TSE sequence compared with DIR (double inversion recovery) sequence in acquisition of fast flow brain vessel images using signal void effect. 32 healthy volunteers (10 men and 22 women; mean age of 31 years; ranging between 28-43 years) who underwent black blood DIR sequence (group A) and the modified TSE sequence (group B) were enrolled in our study. Signal to Noise Ratio (SNR) and Contrast to Noise Ratio (CNR) of the internal carotid arteries' lumen were compared in T1 and T2 weighted images for both group A and B. The images obtained from group B showed lower SNR values in internal carotid artery than the group A in both of the T1 and T2 weighted images (11.49% and 13.66% respectively). While the CNR values were higher in the group B than the group A in both of the T1 and T2 weighted images (8.69% and 7.55 % respectively). The qualitative score of all categories were not significantly different between the two groups. Furthermore approximately 49% of the total scan time was reduced from group B. Our study is to shorten the scanning time and minimize the inconveniences of the patients in acquisition of the black blood images of brain by using the signal void effect in the modified TSE technique while keeping the diagnostic value of the test.

INTERNAL FLOWS IN AIR PUMP OF ROBOT CLEANER (로봇청소기용 에어 펌프 내부 유동 해석)

  • Kim, J.W.;Seok, I.H.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.227-231
    • /
    • 2009
  • Traditional vacuum cleaner adoptsa highly rotating centrifugal impeller for generating suction region at lower pressure. The rotational speed is very high at 35,000 to 40,000 rpm and accessory structure such as a circular brush at the base plate of the cleaning devices is equipped for gathering dusts. Highly rotating impeller is effective for low pressure generation but causes noise problems. Recently, the unwanted noise is removed by installation of air-pump, instead of a centrifugal impeller, and the internal flows of the modified system are estimated in numerical and experimental approach, respectively.

  • PDF

A Study on Vibration Control for Reheater Attemperator Piping in Power Plant (재열기 온도조절 급수배관의 진동저감방안 연구)

  • Jeon, Chang-Bin
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.1-5
    • /
    • 2007
  • A majority of piping vibration problems are induced by internal fluid pulsation; turbulent flow, vortex shedding at internal discontinuities, and pressure pulsation at equipment nozzles. The pulsation at the pressure sources resonates acoustically with the piping and the amplified pressure pulsation can generate shell mode vibration in the piping. Reheater attemperator piping supplies water from feedwater pump to reheater attemperator to control the boiler temperature. In normal operating condition, the high frequency shell mode vibration occurred in the piping with the high level of sound(105 ${\sim}$ 117 dB). The vibration sources are pressure pulsation in the pump nozzle and the frequencies are related to the blade passing frequencies. The objects of this paper are to analyze the cause of the high frequency vibration and to establish corrective actions.

  • PDF

Condition Monitoring of Internal State of Oxygen Converter Chamber Using Lance Behavior Analysis (랜스 거동 분석을 이용한 전로 내부 상태 감시)

  • Lim, Eun-Seop;Kim, Heung-Mook;Kim, Seong-Gon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.658-663
    • /
    • 2000
  • Slopping phenomena deteriorate the productivity and the stability of operation in oxygen converter process. To predict and prevent that, it needs reliable perception of the internal state of the oxygen converter chamber. Equipment was developed to measure the dynamic and static behavior of the oxygen-blowing lance 3-dimensionally and the measured signal is analyzed in relation to slopping phenomena. It was found that the behavior of the lance is strongly correlated to the change of slag foam height and the instability of molten steel behavior. So slopping phenomena can be predicted by simultaneously analyzing the measured behavior of the lance and the control factors such as the flow rate of oxygen and the height of lance.

  • PDF

A study on development of plastic intake manifold module (Plastic 흡기 매니폴드 모듈 개발에 관한 연구)

  • Lee, Jeong-Kyun;Kim, Young-Bok;Joo, Kyung-Jei
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.10a
    • /
    • pp.833-838
    • /
    • 2011
  • Future powertrain technologies will be developed focused on applications of eco-friendly technology for internal combustion engine, electric vehicle and Fuel Cell Electric Vehicle. But it is expected that these cutting edge technologies will not be applied immediately due to lack of infrastructure, technical and economical reasons. Therefore, numerous developments of internal combustion engine will be carried out for the time being. There have been many turbo engine developments undergoing to maximize the engine performance using turbo charger system in accordance with global trend-green technology and downsizing of engine which coincides with HMC's future development strategy. This study reviews the development process and result of plastic intake manifold module which is firstly developed for turbo engine. CAE simulation and experiments were implanted to evaluate design validity.

  • PDF