• 제목/요약/키워드: Internal Fixation

검색결과 460건 처리시간 0.025초

Mini-open Treatment Using Plate of Clavicle Mid-shaft Fractures

  • Park, Yong-Geun;Kang, Hyunseong;Kim, Shinil;Bae, Jong-Hwan;Choi, Sungwook
    • Clinics in Shoulder and Elbow
    • /
    • 제20권1호
    • /
    • pp.37-41
    • /
    • 2017
  • Background: Increased frequency of comminuted clavicle mid-shaft fractures and importance of functional satisfaction through early joint exercise has resulted in higher emphasis on surgical treatments. This study aimed to evaluate the clinical radiological results of treatment of clavicle mid-shaft fractures by open reduction and internal fixation using a plate with a small incision. Methods: The subjects of this study were 80 clavicle mid-shaft fracture cases treated with internal fixation using a plate from October 2010 to July 2014. Clavicle mid-shaft fractures were internally fixated using anatomical plates or locking compression plates. Achievement of bone union, union period, and clavicle length shortening were evaluated radiologically, and clinical assessment was done by using Constant and University of California at Los Angeles (UCLA) scores. Results: All 80 cases were confirmed to have achieved bone union through radiographs with an average union period of 10.9 weeks (range: 7-18 weeks). The average clavicle length of shortening in the affected side was 1.8 mm (range: 0-17 mm). The average UCLA score and Constant score were 33.6 (range: 25-35) and 92.5 (range: 65-100), respectively. Regarding complications, four cases reported skin irritation by metal plates, and one case reported a screw insertion site fracture due to minor trauma history. Conclusions: We were able to induce successful bone union and obtain clinically satisfactory results in displaced mid-shaft fractures of the clavicle without major complications such as nonunion through treatment of internal fixation using a plate.

견봉쇄골탈구와 원위쇄골골절에서 소절개를 이용한 Wolter금속판 내고정술 (Minimal incision Wolter Plate Fixation on the Displaced Lateral End Fracture of the Clavicle and the Acromioclayicular Dislocation)

  • 고상훈
    • Clinics in Shoulder and Elbow
    • /
    • 제5권1호
    • /
    • pp.23-28
    • /
    • 2002
  • Purpose Displaced lateral end fracture of clavicle and acromioclavicular dislocation type Ⅲ∼Ⅵ may be required surgical treatment. Material and Methods : From May 1998 to March 2001, we operated with Welter plate with minimal incision by one surgeon. Immediately, pendulum and passive exercise was initiated after surgery. The shoulder function was evaluated using UCLA score. Average follow up was on 28(12∼45) months. Results : All 11 patients were regained satisfactory function. Average UCLA score was 31.9(29~35) at last follow up. Conclusion . The merit of Welter plate fixation with minimal incision is simple technique, reduced surgical time, smaller scar than large plate, strong fixation, early exercise, reduced implant failure. The disadvantage is expensive, skin irritatatation by long hook. But Welter plate fixation with minimal incision is a good method of internal fixation and excellent clinical result in surgical treatment of type H displaced lateral end fracture of the clavicle and type Ⅲ∼Ⅵ acromioclavicular dislocation.

Complications of the retromandibular transparotid approach for low condylar neck and subcondylar fractures: a retrospective study

  • Hevele, Jeroen Van;Nout, Erik
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제44권2호
    • /
    • pp.73-78
    • /
    • 2018
  • Objectives: The goal of this study was to evaluate the rates of complications, morbidity, and safety with the transparotid approach. Materials and Methods: A retrospective study was conducted and consisted of 53 surgically treated patients in the past five years for low condylar neck and subcondylar fractures. Only patients with malocclusion and who underwent open reduction with internal fixation with the retromandibular transparotid approach were included. The examined parameters were postoperative suboptimal occlusion, deflection, saliva fistula, and facial nerve weakness. Results: Fifty-three patients had an open reduction with internal fixation on 55 sides (41 males, 77.4%; mean age, 42 years [range, 18-72 years]). Four patients (7.5%) experienced transient facial nerve weakness of the marginal mandibular branch, but none was permanent. Four patients had a salivary fistula, and 5 patients showed postoperative malocclusion, where one needed repeat surgery after one year. One patient showed long-term deflection. No other complications were observed. Conclusion: The retromandibular transparotid approach is a safe procedure for open reduction and internal fixation of low condylar neck and subcondylar fractures, and it has minimal complications.

유관 나사 및 Hybrid형 외고정술을 이용한 당뇨병성 샤르코 족관절 신경관절병증의 관절 유합술 (Ankle Arthrodesis using Cannulated Screws & Hybrid Type Rigid External Fixation in Diabetic Charcot Neuroarthropathy)

  • 한경진;노형래;한승환
    • 대한족부족관절학회지
    • /
    • 제14권2호
    • /
    • pp.140-145
    • /
    • 2010
  • Purpose: The diabetic charcot neuroarthropathy of ankle is an infrequent site (around 5%), but is definitely the location that, because of the instability and progressive deformity it involves, cause ulceration in a high percentage of patients, and this can then become a reason for amputation. However, the treatment of this disastrous disease is still challenging. We analyzed the clinical and radiological results of ankle arthrodesis by our fixation method in Charcot neuroarthropathy. Materials and Methods: Seven cases that were diagnosed as charcot neuroarthropathy of ankle arthrodesis were followed for more than 16 months postoperatively. Mean age was 57 years, and the mean follow-up period was 27 months. Anterior approach was used in arthrodesis, and internal fixation by 3 or more cannulated screws and hybrid type external fixation were used. Auto iliac bone for grafting was combined in all cases. External fixator was kept for 3 months without weight-bearing. Then, boots brace was applied for more 3 months allowing partial weight-bearing. Four cases had minor complications such as pin site infection. Preoperative and postoperative AOFAS score, time to fusion and postoperative complications were checked. Results: Postoperative fusion was completed in all cases, and the mean time to fusion was 3.4 months. No postoperative complication was checked. At the last follow-up, the mean AOFAS score had increased from 54 points to 72 points. Patient's satisfaction was over 80%. Conclusion: Satisfactory results were obtained after ankle arthrodesis using internal and hybrid type external fixation combined with auto iliac bone graft in charcot neuroarthropathy with minor complications.

Carved Merocel®을 이용한 비골골절의 고정 (Fixation of Nasal Bone Fracture with Carved Merocel®)

  • 공정식;정재아;강소라;김양우;전영우
    • 대한두개안면성형외과학회지
    • /
    • 제12권2호
    • /
    • pp.93-96
    • /
    • 2011
  • Purpose: In most cases of nasal bone fracture, closed reduction with internal or external splint fixation approach is selected. However, because of indiscriminate insertion of the internal splint without considering of anatomical difference or deformity, insufficient fixation happens frequently that need additional fixation. Therefore, we suggest a new method for providing adequate support in reduced nasal bone by carving $Merocel^{(R)}$ that is fixed for the anatomical structure. Method: Closed reduction and internal fixation with carved $Merocel^{(R)}$ was performed in 15 nasal bone fracture patients from March, 2010 to July, 2010. Each patient was evaluated by physical examination, facial photographic check, simple X-ray, and computerized tomography. On the first day post-operation, location of packing and amount of reduction were checked by follow up X-ray and computerized tomography. In addition, patients' symptoms were evaluated. During the 3-month post-op follow up at out-patient clinic, operator, 2 doctors in training and one assistant performed the objective evaluations by physical examination on nasal dorsal hump, nasal deviation, nasal depression, nasal breath difficulty, and nasal airway obstruction. A survey of subjective patients' satisfaction in 4-stages was also performed. Results: The results of follow-up computerized tomography of the 15 patients revealed that 11 patients had good reduced state. Three patients with combined maxillary frontal process fracture had over reductions. A survey performed on the first day post-operation showed that 14 of 15 patients answered that their current symptoms were more than tolerable. At the 3-month follow-up physical exam, one case had a dorsal hump. However, there were no nasal deviations, nasal depressions, nasal breath difficulties, or nasal airway obstructions. Twelve of the 15 patients answered more than moderate on the 3-month survey. Conclusion: Intranasal packing after carving the $Merocel^{(R)}$ considering anatomical structure is a new effective method to promote proper-reduction, maintain stability, and minimize patients' symptoms by addition of a simple procedure.

The Role of Minimally Invasive Plate Osteosynthesis in Rib Fixation: A Review

  • Bemelman, Michael;van Baal, Mark;Yuan, Jian Zhang;Leenen, Luke
    • Journal of Chest Surgery
    • /
    • 제49권1호
    • /
    • pp.1-8
    • /
    • 2016
  • More than a century ago, the first scientific report was published about fracture fixation with plates. During the 1950's, open reduction and plate fixation for fractures were standardized by the founders of Arbeitsgemeinschaft $f{\ddot{u}}r$ osteosynthesefragen/Association for the Study of Internal Fixation. Since the introduction of plate fixation for fractures, several plates and screws have been developed, all with their own characteristics. To accomplice more fracture stability, it was thought the bigger the plate, the better. The counter side was a compromised blood supply of the bone, often resulting in bone necrosis and ultimately delayed or non-union. With the search and development of new materials and techniques for fracture fixation, less invasive procedures have become increasingly popular. This resulted in the minimally invasive plate osteosynthesis (MIPO) technique for fracture fixation. With the MIPO technique, procedures could be performed with smaller incisions and thus with less soft tissue damage and a better preserved blood supply. The last 5 years rib fixation has become increasingly popular, rising evidence has becomeavailable suggesting that surgical rib fixation improves outcome of patients with a flail chest or isolated rib fractures. Many surgical approaches for rib fixation have been described in the old literature, however, most of these techniques are obscure nowadays. Currently mostly large incisions with considerable surgical insult are used to stabilize rib fractures. We think that MIPO deserves a place in the surgical treatment of rib fractures. We present the aspects of diagnosis, preoperative planning and operative techniques in regard to MIPO rib fixation.

개방형 자동굴절검사기의 주시거리에 따른 굴절이상도와 가상주시형 자동굴절 검사기의 굴절이상도와의 비교 연구 (A Study of Comparison Between Refractive Errors by Fixation Distance Variation with N-vision(open-view type) Auto-refractor and Refractive Error with Canon(Internal Fixation Target Type) Auto-refractor)

  • 김재도;김대현;전인철
    • 한국안광학회지
    • /
    • 제16권4호
    • /
    • pp.433-438
    • /
    • 2011
  • 목적: 개방형과 가상주시형 자동굴절검사기에 의한 굴절이상도를 비교하여 그 차이를 알아보고 개방형 검사기를 이용하여 정적굴절검사를 시행할 때 주시시표와 피검자와의 최소거리를 알아보고자 하였다. 방법: 교정시력 1.0 이상이고 안과적 질환이 없는 성인(22.2${\pm}$3.4세) 21명(42안)을 대상으로 자동굴절검사기에 의한 굴절검사를 실시하였다. 굴절검사는 가상주시형(RK-F1, Canon, Japan)을 사용하였으며 개방형(N-vision-K5001, Shin-nippon, Japan)을 사용하여 1 m, 3 m, 4 m, 6 m의 위치를 주시하는 상태에서 거리에 따른 굴절이상도를 비교하였다. 결과: 1 m 주시거리에서 개방형에 의한 전체대상자의 평균 굴절이상도(-2.75${\pm}$1.84 D)는 가상주시형에 의한 평균 굴절이상도(-2.95${\pm}$2.04 D)와 유의적인 차이가 없었다(p=0.06). 그러나 3 m, 4 m, 6m 주시거리에서 개방형에 의한 평균굴절이상도는 가상주시형에 의한 굴절이상도보다 낮은 근시성 굴절이상도를 보였다(p<0.05). 결론: 정적굴절검사를 위해 개방형 굴절검사기를 사용하는 경우 5~6 m의 검사거리를 확보하지 않더라도 3 m 이상의 측정거리에서도 가능하다.

Treatment of extensive comminuted mandibular fracture between both mandibular angles with bilateral condylar fractures using a reconstruction plate: a case report

  • Lee, Kwonwoo;Yoon, Kyuho;Park, Kwan-Soo;Cheong, Jeongkwon;Shin, Jaemyung;Bae, Jungho;Ko, Inchan;Park, Hyungkoo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제40권3호
    • /
    • pp.135-139
    • /
    • 2014
  • This following case report describes the open reduction, internal fixation and the reconstruction of an extensive comminuted mandibular fracture with bilateral condylar fractures in a 19-year-old male patient with an intellectual disability and autistic disorder. He suffered fall trauma, resulting in shattered bony fragments of the alveolus and mandibular body between both mandibular rami, the fracture of both condyles and the avulsion or dislocation of every posterior tooth of the mandible. The patient underwent open reduction and internal fixation between both mandibular rami using a reconstruction plate, open reduction and internal fixation of the shattered fragments using miniplates and screws, and the closed reduction of the bilateral condylar fractures.

후하악부 절개를 통한 하악골 관절돌기 골절의 치료 후 임상경과에 대한 고찰 (Consideration of Clinical Progress after Open Reduction with Retromandibular Approach in Treatment of Mandibular Condyle Fractures)

  • 김한구;권남호;배태희;김우섭
    • 대한두개안면성형외과학회지
    • /
    • 제9권1호
    • /
    • pp.17-22
    • /
    • 2008
  • Purpose: For several decades, open reduction has been a controversial issue in mandibular condyle fracture. The authors have successfully used the open reduction and internal fixation with retromandibular approach and have found it to be satisfactory for mandibular condyle fracture. Methods: A total of 10 patients with mandibular condyle fracture underwent open surgical treatment using retromandibular approach. The incision for the retromandibular approach was carried below the ear lobe and the facial nerve branches were identified. Dissection was continued until the fracture site was exposed and internal fixation was performed with miniplate following intermaxillary fixation. The average period of joint immobilization was 1 weeks and the arch bars were removed in 3 weeks on average. The preoperative and postoperative panoramic view and three-dimensional computed tomography were compared. During the follow up period, we evaluated the presence of malocclusion, chin deviation, trismus, pain, click sound, facial nerve palsy, hypertrophic scar and skin fistula. Results: According to the radiographic findings, the fractured condyle was reducted satisfactorily in all patients without any symptoms of facial palsy. During the follow up period ranged form 6 to 12 months, all clinical symptoms were improved except in one case with chin deviation and malocclusion. Conclusion: Using open reduction and internal fixation of mandibular condyle fracture with retromandibular approach, all results were satisfactory with good functional outcomes and minimal complication. We concluded that the open surgical treatment should be considered as the first choice for mandibular condyle fracture management.

생체 흡수성 판과 나사못을 이용한 족근 관절 골절의 치료 (Fixation with Bioabsorbable Polylactide Plate and Screws for the Treatment of the Ankle Fractures)

  • 권덕주;이용범;신준
    • 대한족부족관절학회지
    • /
    • 제13권1호
    • /
    • pp.80-84
    • /
    • 2009
  • Purpose: The purpose of this article is to assess the efficacy of a bioabsorbable polylactide (PLA) plate and screw for treating injuries of ankle fractures. Materials and Methods: 24 patients who underwent an open reduction and internal fixation operation for ankle fractures from July 2005 to March 2007 were enrolled into the study. There were 15 men and 9 women. The average age of the patients was 44 years and the average follow-up period was 16 years and two months (16.2 months). All cases were divided into low grade fracture patient (11) who belongs in type A and B of Danis-Weber classification and high grade fracture patient (13) who belongs in type C1, C2 of Danis-Weber classification, and each groups were analyzed by clinical (Meyer score) and radiological finding at the time of their last follow-up evaluation. Results: The clinical results according to Meyer scoring system, showed that all patient with low grade fracture had good to excellent result, but only 54% of patient with high grade fracture had good to excellent result. According to Cedell's radiologic finding, there were 91% cases above fair in low grade fracture. But there were 62% of patient above fair result in high grade fracture, the reduction losses were seen in 38% of patient with high grade fracture. Conclusion: Bioabsorbable PLA plate and screw is good internal fixation device which doesn't have additional operation for removal of implant because of slow absorption within the human body. It showed sufficient strength for acquisition and maintenance of reduction in low grade fracture, but need attention to use because of many cases of reduction loss in high grade fracture. So, it seems to be safe and effective when used in heeling of low grade fracture under considering about type of fracture sufficiently.

  • PDF