• Title/Summary/Keyword: Internal Coupler

Search Result 33, Processing Time 0.028 seconds

Development of 3 D.O.F parallel robot's simulator for education

  • Yoo, Jae-Myung;Kim, John-Hyeong;Park, Dong-Jin
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.2290-2295
    • /
    • 2005
  • In this paper, it is developed simulator system of 3 D.O.F parallel robot for educate of expertness. This simulator system is composed of three parts ? 3 D.O.F parallel robot, controller (hardware) and software. First, basic structure of the robot is 3 active rotary actuator that small geared step motor with fixed base. An input-link is connected to this actuator, and this input-link can connect two ball joints. Thus, two couplers can be connected to the input-link as a pair. An end-plate, which is jointed by a ball joint, can be connected to the opposite side of the coupler. A sub-link is produced and installed to the internal spring, and then this sub-link is connected to the upper and bottom side of the coupler in order to prevent a certain bending or deformation of the two couplers. The robot has the maximum diameter of 230 mm, 10 kg of weight (include the table), and maximum height of 300 mm. Hardware for control of the robot is composed of computer, micro controller, pulse generator, and motor driver. The PC used in the controller sends commands to the controller, and transform signals input by the user to the coordinate value of the robot by substituting it into equations of kinematics and inverse kinematics. A controller transfer the coordinate value calculated in the PC to a pulse generator by transforming it into signals. A pulse generator analyzes commands, which include the information received from the micro controller. A motor driver transfer the pulse received from the pulse generator to a step motor, and protects against the over-load of the motor Finally, software is a learning purposed control program, which presents the principle of a robot operation and actual implementation. The benefit of this program is that easy for a novice to use. Developed robot simulator system can be practically applied to understand the principle of parallel mechanism, motors, sensor, and various other parts.

  • PDF

고속 연접봉의 응력 변동

  • 김재호;신영재
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.15 no.2
    • /
    • pp.404-412
    • /
    • 1991
  • In the design of high speed machinery, designers must consider the problem of possible structural failure due to excessive dynamically varying stresses, which are induced by the varying external loads and internal inertia forces, in the links of the mechanism. A study of the dynamically induced stresses would indicate what values of the minimum permissible fatigue strength should be for safe mechanism operation. This paper investigates the nature of the stress fluctuation in high speed mechanism on the basis of the effects of both the loads and the friction. The latter is apt to be neglected in the usual analysis in spite of the fact that it is always generated in the operating machinery. The analysis is performed on the coupler of the slider-crank mechanism for illustrative purposes and the results are expressed in a non-dimensional form for design applications.

Characteristics of Insulation Aging in 4.16kV Motor Stator Windings (4.16kV 전동기 고정자 권선의 절연열화 특성)

  • Kim, Hee-Dong;Kong, Tae-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1381_1382
    • /
    • 2009
  • Nondestructive tests were performed on two 4.16kV motors. Epoxy-mica coupler(80pF) was connected to 4.16 kV motor stator windings. The voltage applied to the stator windings was 2.4 kV, 3.0kV, 3.5kV and 4.16kV, respectively. Digital partial discharge detector(PDD) and turbine generator analyzer(TGA) were used to measure partial discharge(PD) activity. TGA summarizes each plot with two quantities such as the normalized quantity number(NQN) and the peak PD magnitude(Qm). The PD levels in pC were measured with PDD. PD patterns of stator windings were indicated the internal discharge. PD patterns are consistent with the result of measurement using PDD and TGA.

  • PDF

Analysis of Partial Discharge in High Voltage Motor Model Coils (고압전동기 모델 코일의 부분방전 분석)

  • Kim, Hee-Dong;Kong, Tae-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2091-2093
    • /
    • 2005
  • Five model coils of 6.6kV motor were manufactured with several defects. These stator coils have artificial defects such as void of groundwall insulation, removal of semi-conductive coating and damage of strand insulation. Epoxy-mica coupler(80 pF) was connected to five model coil terminals, respectively The voltage applied to the coils was 3.81kV, 4.76kV, 6.0kV and 6.6kV. Partial discharge(PD) tests performed in the laboratory and shield room. Digital PD detector (PDD) and turbine generator analyzer(TGA) were used to measure PD activity. TGA summarizes each plot with two quantities such as the normalized quantity number(NQN) and the peak PD magnitude(Qm). The PD levels in pC were measured with PDD. PD patterns of model coils were indicated the internal and slot discharges. PD patterns coincide with both PDD and TGA.

  • PDF

Implemention of diagnosis algorithm to traction equipment for railway (철도차량 추진시스템의 진단 알고리즘 구현)

  • Ko, Byeong-Hun;Park, Young;Kwon, Sam-Young;Park, Hyun-June;Kim, Hee-Dong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.500-501
    • /
    • 2007
  • The method of maintenance in railway is going to be changed to improve reliability on traction equipment. Partial discharge (PD) tests are useful to evaluate the insulation condition of stator winding. This paper describes the use of PD tests with 5 model coils which have the defects such as internal, slot discharge. The PD tests are performed with epoxy-mica coupler 500 pF at various AC voltages. The result of test shows PD pattern can correlate with the species of defects on 5 model coils.

  • PDF

A Study on the Corrosion Prevention of the Integral Series Generator for Military Vehicles (군용차량용 엔진일체형 직렬 발전기 부식 방지에 관한 연구)

  • Kang, Tae-Woo;Kim, Seong-Gon;Shin, Cheol-Ho;Lee, Kye-Sub
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.6
    • /
    • pp.74-79
    • /
    • 2019
  • The military vehicle produces electric power through an engine-integrated serial hybrid generator that is connected to the engine and does not have a separate generator installation space. However, depending on the mechanical characteristics of the connection between the generator and the engine, iron oxide for internal rusting and lubrication grew scattered. The iron oxide is adhered to the starter to deteriorate the starting performance, and there is a problem that the noise of the leg due to wear of the gear is increased. To solve this problem, the connection spline material and the surface treatment of the engine were improved and the shape was changed to a grease sealing type to prevent the generation of iron oxide inside. As the shape of the generator connector composing the shafting system was changed, the integrity of the structure was confirmed through the torsional endurance test. In addition, through the actual vehicle load test, it was verified that no corrosion occurred during the target life span without internal corrosion. It was confirmed that the anti-scattering structure of the grease effectively suppresses the generation of iron oxide, thereby reducing the noise generated from the generator. In this paper, we propose a fundamental solution to the degradation of the starter and the noise generation by preventing the back corrosion caused by the serial hybrid generator installed between the engine and the transmission.

Analysis of Partial Discharge in High Voltage Motor Model Coils (고압전동기 모델 코일에서 부분방전 분석)

  • Kim, Hee-Dong
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.4
    • /
    • pp.178-182
    • /
    • 2006
  • Five model coils of 6.6 kV motor were manufactured with several defects. These stator coils have artificial defects such as void of groundwall insulation, removal of semi-conductive coating and damage of strand insulation. Epoxy-mica coupler(80 pF) was connected to five model coil terminals. The voltage applied to the coils was 3.81 kV, 4.76 kV, 6.0 kV and 6.6 kV, respectively. Partial discharge(PD) tests performed in the laboratory and shield room. Digital PD detector(PDD) and turbine generator analyzer(TGA) were used to measure PD activity. TGA summarizes each plot with two quantities such as the normalized quantity number(NQN) and the peak PD magnitude(Qm). The PD levels in pC were measured with PDD. PD patterns of model coils were indicated the internal and slot discharges. PD patterns are consistent with the result of measurement using PDD and TGA instruments. AC breakdown test was performed on five model coils in order to confirm the result of PD measurements. All the failures were located in a line-end coil at the exit from the core slot.

Implementation of Polarization Beam-Splitter based on DFB-Assisted Plasmonic Multimode Interference Coupler (DFB 구조형 플라즈마 다중모드 간섭 결합기를 사용한 편향기의 구현)

  • Ho, Kwang-Chun
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.13 no.5
    • /
    • pp.143-148
    • /
    • 2013
  • A novel ultracompact polarization beam-splitter (PBS) combining two plasmonic multimode interference couplers (P-MMICs) and DFB guiding structure is implemented. The $2{\times}1$ and $1{\times}2$ P-MMICs are designed to collect the polarized powers of TE and TM modes reflected by or transmitted through an internal DFB structure. The simulation results show that the designed DFB-assisted PBS is very short (about $75{\mu}m$), and has a low insertion loss, a high extinction ratio, and a broad bandwidth of 20 nm.

A Study for Operation Technique Plan of Low-Cost UAV Data Bus (저가형 무인항공기 DATA BUS 운용기술 방안 연구)

  • Gil, Hyun-Cheol;Ahn, Dong-Mhan;Hong, Gyo-Young
    • Journal of Advanced Navigation Technology
    • /
    • v.16 no.6
    • /
    • pp.1024-1031
    • /
    • 2012
  • In the past, the part of development of that is used for the military aviation target or reconnaissance is being extended to the range of application not only reconnaissance but also civilian industry as the introduction of the newest IT technology and the technical evolution. The Civilian low-cost UAV that is expected growth at the market of UAV in the world is accelerated to the extended applicability in the fields. However, The UAV study is recently focused on the Link and The Data bus because the main decision of the civilian UAV system configuration is not suitable to determinate the factory of price. In this paper is analysed the UAV data bus through the simulation in same condition both the CAN Bus which used the automobile industry and the MIL-STD-1553B which is used the aviation industry. As a comparison result, we identified that the CAN Bus of conventional configuration is possible to transmit the data without the need for a separate coupler equipment against the MIL-STD-1553B data. Thus, we identified that the CAN bus is capable to apply as a low-cost UAV internal data bus to optimize configuration and weight than 1553B.

Risk Factors Related to Photo Couplers(P/C) for Signal Transmission by Electronic Devices (전자기기의 신호전송을 위한 Photo Couplers(P/C) 의 위험 요소 발굴)

  • Park, Hyung-Ki;Choi, Chung-Seog
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.2
    • /
    • pp.26-30
    • /
    • 2013
  • The purpose of this study is to find risk factors by analyzing the operation principle of a photo coupler (P/C) used to remove the noise of electronic devices and establish a base for the performance improvement of developed products. It was found from the P/C circuit analysis of normal products that they were equipped with an electrolytic condenser of $0.1{\mu}F$ to smooth system signals. Due to the epoxy resin packing the external part of the P/C, this study experienced a limit to visually examine the damage to it. It could be seen from the analysis of electric characteristics of the P/C that the forward voltage ($V_f$) and reverse current ($I_r$) were 1.3 V and 10 uA, respectively. In addition, it is required that the breakdown voltage (VCE) between the collector (C) and emitter (E) be maintained at less than 35 V. The and of the damaged product #1 were comparatively good. However, the measurement of was 100.0 uA. From this, it is thought that a short circuit occurred to the internal circuit. Moreover, from the fact that the of the damaged product #2 was open circuit and the measurement of was 0.0 uA, it is thought that the collector and emitter was separated or insulation resistance was significantly high. Furthermore, from the fact that the of the damaged product #3 was open circuit and the measurement of was 0.0 uA, it is thought that the space between the collector (C) and emitter (E) failed to meet the design standard or that they were separated. Therefore, it is thought that fabricating the P/C by increasing the reverse current 10 mA to 50 mA will prevent its malfunction.