• Title/Summary/Keyword: Intermediate Level

Search Result 918, Processing Time 0.026 seconds

Application of Spatial Modulation of Magnetization to Cervical Spinal Stenosis for Evaluation of the Hydrodynamic Changes Occurring in Cerebrospinal Fluid

  • Kwang-Hun Lee;Tae-Sub Chung;Tae Joo Jeon;Young Hwan Kim;Daisy Chien;Gerhard Laub
    • Korean Journal of Radiology
    • /
    • v.1 no.1
    • /
    • pp.11-18
    • /
    • 2000
  • Objective: To evaluate the hydrodynamic changes occurring in cerebrospinal fluid (CSF) flow in cervical spinal stenosis using the spatial modulation of magnetization (SPAMM) technique. Materials and Methods: Using the SPAMM technique, 44 patients with cervical spinal stenosis and ten healthy volunteers were investigated. The degree of cervical spinal stenosis was rated as low-, intermediate-, or high-grade. Low-grade stenosis was defined as involving no effacement of the subarachnoid space, intermediate-grade as involving effacement of this space, and high-grade as involving effacement of this space, together with compressive myelopathy. The patterns of SPAMM stripes and CSF velocity were evaluated and compared between each type of spinal stenosis and normal spine. Results: Low-grade stenosis (n = 23) revealed displacement or discontinuity of stripes, while intermediate- (n = 10) and high-grade (n = 11) showed a continuous straight band at the stenotic segment. Among low-grade cases, 12 showed wave separation during the systolic phase. Peak systolic CSF velocity at C4-5 level in these cases was lower than in volunteers (p < .05), but jet-like CSF propulsion was maintained. Among intermediate-grade cases, peak systolic velocity at C1-2 level was lower than in the volunteer group, but the difference was not significant (p > .05). In high-grade stenosis, both diastolic and systolic velocities were significantly lower (p < .05). Conclusion: Various hydrodynamic changes occurring in CSF flow in cervical spinal stenosis were demonstrated by the SPAMM technique, and this may be a useful method for evaluating CSF hydrodynamic change in cervical spinal stenosis.

  • PDF

Development of a Quality Assurance Safety Assessment Database for Near Surface Radioactive Waste Disposal

  • Park J.W.;Kim C.L.;Park J.B.;Lee E.Y.;Lee Y.M.;Kang C.H.;Zhou W.;Kozak M.W.
    • Nuclear Engineering and Technology
    • /
    • v.35 no.6
    • /
    • pp.556-565
    • /
    • 2003
  • A quality assurance safety assessment database, called QUARK (QUality Assurance Program for Radioactive Waste Management in Korea), has been developed to manage both analysis information and parameter database for safety assessment of low- and intermediate-level radioactive waste (LILW) disposal facility in Korea. QUARK is such a tool that serves QA purposes for managing safety assessment information properly and securely. In QUARK, the information is organized and linked to maximize the integrity of information and traceability. QUARK provides guidance to conduct safety assessment analysis, from scenario generation to result analysis, and provides a window to inspect and trace previous safety assessment analysis and parameter values. QUARK also provides default database for safety assessment staff who construct input data files using SAGE(Safety Assessment Groundwater Evaluation), a safety assessment computer code.

Water Masses and Flow Fields of the Southern Ocean Measured by Autonomous Profiling Floats (Argo floats)

  • Park, Young-Gyu;Oh, Kyung-Hee;Suk, Moon-Sik
    • Ocean and Polar Research
    • /
    • v.27 no.2
    • /
    • pp.183-188
    • /
    • 2005
  • Using data from Argo floats collected in the Southern Ocean, we describe water mass prop erties and flow fields at intermediate levels (1000m and 2000m levels). Water mass properties from Argo floats, which are consistent with those from previous hydrographic surveys, reflect the movement of the floats well even without quality control on the Argo data. Since the flow fields from the Argo floats do not cover the entire Southern Ocean, we could not obtain a general circulation pattern, especially at the 2000m level. We, however, can confirm the general eastward tendency due to ACC largely following the topography.

Environmental radiation monitoring program of low- and intermediate- level waste disposal site ($\cdot$저준위 방사성폐기물 처분시설 환경방사선조사 계획)

  • 윤철환;한재문;김경덕
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2003.11a
    • /
    • pp.239-243
    • /
    • 2003
  • Environmental monitoring program is investigated based on Atomic Energy Law and foreign country radiation monitoring programs on low-and intermediate level radioactive waste disposal site. It is anticipated that the number of radiation measurements and samples will be higher than those of NPP's. The radiation monitoring program on LLW disposal site should be well prepared reflecting PA, site characteristics and regulation.

  • PDF

A Basical Study on the Preparing of Container Used for Treatment and Disposal of Low-and Intermediate-Level Radioactive Wastes(I) (저.중준위 방사성 폐기물의 고화처리 및 처분용 용기 개발을 위한 기초연구(1))

  • 홍원표;정수영;황의환;조헌영;김철규
    • Journal of the Korean Ceramic Society
    • /
    • v.25 no.2
    • /
    • pp.101-110
    • /
    • 1988
  • In order to improve the physical properties of concrete used for treatment and disposal container of low-and intermediate-level radioactive wastes, OPC (ordinary portland cement), ACPC (asphalt coated portland cement) and EPC(epoxy-portland cement) concrete specimens were prepared, and the physical properties of each concrete specimen were tested. According to the experimental results, EPC concrete showed better physical properties than ACPC and OPC concrete, however, ACPC concrete proved to be a best material for treatment and disposal container of radwastes in view of economic aspect and physical properties.

  • PDF

An Experimental Study on Control Strategy of LED System Using Daylight (주광을 활용한 LED조명시스템의 컨트롤에 관한 실험적 연구)

  • Yun, Gyeong;Yoon, Kap-Chun;Kim, Kang-Soo
    • KIEAE Journal
    • /
    • v.10 no.6
    • /
    • pp.33-39
    • /
    • 2010
  • Visual Environment and productivity are correlated. So we need to create a comfortable visual environment and maintain proper workplane illumination level. We can obtain lighting energy savings and comfortable visual environment using daylight and LED lights. In this study, we characterized the indoor illuminance level according to the sky condition and proposed dimming control strategy of LED lights. Energy savings in On/Off control mode are 40% at clear sky and 28% at intermediate sky. In dimming control mode, energy savings are 77.2% at clear sky and 64.1% at intermediate sky. Then we obtain the appropriate dimming control strategy of LED lights based on data. Dimming rates are 0-14.2-80(min-avg-max, %) for LED 1, 0-19.9-60% for LED 2 and 30-61.4-90% for LED 3. Lighting energy savings are 68.2% for LED dimming system applied this control method.

Phenotypic Analysis of Neurofilament Light Chain E397K Mutant in Cultured Cells

  • Kim, Sung-Kuk;Chang, Jong-Soo
    • Biomedical Science Letters
    • /
    • v.12 no.4
    • /
    • pp.413-418
    • /
    • 2006
  • Charcot-Marie-Tooth disease (CMT) is blown as one of the inherited disorder of peripheral nervous system. Recently, it was found that point mutations in the neurofilament light subunit (NF-L) gene cause CMT. Neurofilaments (NFs) are heteropolymers consist of NF-L, NF-M and NF-H. To assess the relationship between CMT and NF-L mutation in cellular level, we performed phenotypic analysis of the mutant NF-L (E397K) using cultured cell lines. Vimentin-deficient human adrenal carcinoma SW13 (Vim-) cells have a potential to form the intermediate filaments when the cells are expressing both NF-L and NF-M. Our results show that co-expression of wild type NF-L with NF-M showed intermediate filament formation in SW13 (Vim-) cells, while E397K with NF-M did not. This result means that E397K mutant lost its ability to form the intermediate filament in vivo, and further suggests that the E397K mutation is closely related to CMT.

  • PDF