• 제목/요약/키워드: Interlock

검색결과 166건 처리시간 0.031초

SFC 그래픽 언어로 기술된 공정제어 시스템에서 효율적인 에러관리 방법 (Efficient Error Management Method in Process Control System Described by SFC Graphical Language)

  • 전호익;우광준
    • 조명전기설비학회논문지
    • /
    • 제14권1호
    • /
    • pp.59-66
    • /
    • 2000
  • 최근 산업공정 시스댐이 복잡해지고 고도의 성능을 요구함에 따라 PLC의 하드혜어와 소프트웨어의 성능이 향상되었다. SFC 그래픽 언어는 순차 논리 알고리즘을 기술뿐만 아니라 인터록 제어 알고리즘과 같은 에러 관리 알고리즘을 기술하는 데에도 적합하다. 본 논문에서는 산업 공정 제어 시스템을 기술하는데 있어서 효과적으로 에러를 관리하기 위해 제한자를 이용 한 에러 관리 방법올 제안하였으며, 제안된 방법으로 필름 코탱기 제어 시스템을 구현한 결과 에러 관리가 용이하고 프로그랩 메모리의 용량을 줄일 수 있었음을 확인하였다.

  • PDF

Modified Twin Blocks에 의한 성장기 아동의 II급 부정교합의 치료증례 (A CASE REPORT ON TREATMENT OF CLASS II MALOCCLUSION WITH TWIN BLOCKS IN GROWING CHILD)

  • 양규호;박재홍
    • 대한소아치과학회지
    • /
    • 제21권2호
    • /
    • pp.577-585
    • /
    • 1994
  • The Twin Blocks technique was developed by Dr. William Clark of Scotland during the early 1980's. Twin Blocks are an uncomplicated system that incorporates the use of upper and lower bite blocks. These blocks reposition the mandible and redirect occlusal forces to achieve rapid correction of malocclusions. They are also comfortable and the patients wear them full-time-inducing eating time. Occlusal forces transmitted through the dentition provide a constant proprioceptive stimulus to influence the rate of growth and the trabecular structure of the supporting bone. The features of Twin Blocks mean easier and quicker treatment. The occlusal inclined plane is the fundamental functional mechanism of the natural dentition. Twin blocks are bite blocks that effectively modify the occlusal inclined plane to induce favorably directed occlusal forces by causing a functional mandibular displacement. Upper and lower bite blocks interlock at a $45^{\circ}$ angle and are designed for full-time wear to take advantage of all functional forces applied to the dentition including the forces of mastication. The patients who were treated with modified Twin Blocks, and following results were observed: 1. Large overjet and deep overbite were corrected. 2. Class II molar relationship was changed into Class I. 3. Labial inclination of upper incisors was corrected by adjustment of labial bow of upper bite block. 4. The profiles of two patients were improved by anterior displacement of mandible.

  • PDF

통합적 휴먼에러 분석 모델을 이용한 자동차 유리공장의 사고 원인 분석 (Analysis of Accidents Causes in an Auto-Glass Manufacturing Company using the Comprehensive Human Error Analysis Model)

  • 임현교;이승훈
    • 한국안전학회지
    • /
    • 제27권4호
    • /
    • pp.90-95
    • /
    • 2012
  • To prevent similar accidents with the basis of industrial accidents already occurred in industrial plants, it would be possible only after true causes are grasped. Unfortunately, however, most accident investigation carried out with the basis of legal regulation failed to grasp them so that similar accidents have been repeated without cease. This research aimed to find out differences between results from conventional accident investigation and those from human error analysis, and to draw out effective and practical counter-plans against industrial accidents occurred repeatedly in an autoglass manufacturing company. As for analysis, about 110 accident cases that occurred for last 7 years were collected, and by adopting the Comprehensive Human Error Analysis Technique developed by the previous researchers, not direct causes but basic fundamental causes that might induce workers to human errors were sought. In consequence, the result showed that facility factors or environmental factors such as improper layout, mistakes in engineering design, and malfunction of interlock system were authentic major accident causes as opposed to managerial factors such as personal carelessness or failure to wearing personal protective equipments, and/or improper work methods.

ITER 초전도자석 전원공급장치 제어시스템의 예비설계 (Preliminary Design of AC/DC Converter Control System for ITER Superconducting Magnet)

  • 서재학;오종석;최정완;황광철;강재봉;이원석;서은일;김형기;김명기
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2012년도 추계학술대회 논문집
    • /
    • pp.251-252
    • /
    • 2012
  • ITER(국제핵융합실험로) 제어시스템은 중앙제어와 Plant System으로 구성되며 CODAC, Central Interlock, Central Safety System으로 구분된다. 초전도자석에 전류를 공급하는 AC/DC 컨버터 시스템은 2상한, 4상한 구조의 전원 장치, 초기 플라즈마 발생에 필요한 Switching Network Unit, 코일에 저장된 에너지의 급속 방전을 위한 Fast Discharge Unit 및 무효 전력 보상장치로 구성된다. 4상한 전원장치는 1, 2, 4, 6대의 전원 장치가 직렬 접속되어 무효전력 발생이 최소로 하도록 제어된다. 대용량의 무효전력이 급격히 변화는 환경에서 계통 전압을 유지하기위해 무효전력보상장치는 각 전원 장치가 예측한 무효전력 값을 이용하여 제어한다. 본 논문은 ITER 전원 장치를 운전하기 위한 제어시스템의 개요와 예비설계 결과이다.

  • PDF

모래다짐말뚝(SCP) 적용을 위한 굴패각.모래 혼합토의 투수 및 전단 강도 특성 (Permeability and Shear Strength Characteristics of Oyster Shell-Sand Mixture for Application to SCP)

  • 윤현석;이기호;박준범;이형주
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2004년도 춘계학술발표회
    • /
    • pp.863-868
    • /
    • 2004
  • The use of oyster shells is proposed as a substitute construction material for geotechnical applications. To investigate recycling possibility as a substitute of sand compaction pile (SCP) for oyster shells, the geotechnical characteristics including permeability and shear strength of crushed oyster shell, sand and crushed oyster shell-sand mixted soil. Experimental results show that the crushed oyster shells are lighter than sand in weight, and have similar characteristics on permeability to sand. The results of direct shear test show that the measured value of friction angle ${\Phi}$ of crushed oyster shell was lager than that of sand. It would be expected that more angular particles (crushed oyster shells) would interlock more thoroughly than rounded particles (send).

  • PDF

면 편성물의 방염처리에 의한 형태안정성의 변화 (Changes of Dimensional Stability of Cotton Knitted Fabrics after Flame Resistant Treatment)

  • 지주원
    • 한국의류학회지
    • /
    • 제29권9_10호
    • /
    • pp.1274-1284
    • /
    • 2005
  • Effect of fixation methods and relaxation treatment on the dimensional stability and physical properties of MDPPA/HMM treated cotton knitted fabrics were studied. Combination of four different fixation methods - relaxation, swelling agent treatment, pad dry cure fixation, and wet fixation - were applied to flame retardant finish of 4 kinds of cotton knitted fabric with MDPPA/HMM. Then these fabrics were washed 10 times. As a result, In swelling treatment on 10G showed relatively higher value of length shrinkage than 14G. Length and width shrinkage were increased by initial washing treatment and no further change was shown after 6 washing cycles. After 10 washing cycles, length and width shrinkage decreased. The KES standardized basic value of B/W, 2HB/W and bursting strength of interlock were relatively larger than those of single jersey. The values of B/W and 2HB/W of cotton knitted fabrics were increased by relaxation and washing treatment but were decreased by swelling treatment. In addition, the bursting strength of the cotton knitted fabrics was decreased after fusing, washing and relaxation treatment.

Finite element investigation of the joints in precast concrete pavement

  • Sadeghi, Vahid;Hesami, Saeid
    • Computers and Concrete
    • /
    • 제21권5호
    • /
    • pp.547-557
    • /
    • 2018
  • This paper measures the mechanical response of precast pavement joints under moving axle loads using the finite-element method, and the models were validated with results of field tests. In order to increase the ability to use the non-linear FE analysis for design and assessment of precast pavement subjected to moving axle load, this paper investigated the effects of different load transfer between the slabs using the ABAQUS finite-element package to solve the nonlinear explicit model equations. The assembly of the panels using dowels and groove-tongue keys has been studied to assess the efficiency of keyway joint system. Concrete damage plasticity model was used to calculate the effects of permanent damages related to the failure mechanisms. With aggregate interlock as the only load transferring system, Load transfer efficiency (LTE) is not acceptable when the axle load reaches to slab joints. The Finite-element modelling (FEM) results showed that keyway joints significantly reduced tensile stresses developed at the mid-slab. Increasing the thickness of the tongue the LTE was improved but with increasing the height of the tongue the LTE was decreased. Stresses are transferred to the adjacent slab efficiently when dowels are embedded within the model. When the axle load approaches joints, tensile damage occurs sooner than compressive damage, but the damage rate remains constant, then compressive damage increases significantly and become the major form of distress under the dowels.

Poly(ether-b-ester) Thermoplastic Elastomers의 합성 및 물성 연구 (Synthesis and Properties of Poly(ether-b-ester)Thermoplastic Elastomers)

  • 김홍선;정맹식
    • 한국안광학회지
    • /
    • 제6권1호
    • /
    • pp.119-124
    • /
    • 2001
  • 디메틸 테레프탈레이트 (DMT), 1.4-부탄디올 (1.4-BD) 그리고 분자량이 2000인 폴리테트라 메틸렌 에테르 글리콜 (PTMG)로 부터 폴리에스터계 열가소성 탄성체 (TPEE)를 합성할 수 있었다. 열적 안정성 및 기계적 물성을 증대시킬 목적으로 열처리를 하였으며, 이에 따라 결정성 hard segmen의 보다 규칙적인 배열로 인한 향상된 물성을 확인 할 수 있었다. 본 실험에서 합성된 공중합체는 soft segment의 함량이 증가함에 따라 융점 및 결정화도가 감소함을 보여 주었다. 기계적 물성의 경우, soft segment의 함량이 35%인 공중합체가 soft segment와 hard segment간 최적의 물리적 가교점 형성으로 인하여 가장 우수함이 관찰되었다.

  • PDF

Ion Beam Assisted Deposition System의 제작 및 자동화

  • 손영호
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 1998년도 제14회 학술발표회 논문개요집
    • /
    • pp.27-27
    • /
    • 1998
  • 진공기술의 응용과 진공환경의 이용은 더 이상 논하지 않더라도 산업 전반에 그 충요성이 점점 더 커가고 있다. 이러한 여건에도 불구하고 진공율 이용하는 system 개밟의 국산화는 수 입하는 system으$\mid$ 수에 비하여 절대적으로 부족하며, 또한 개발하는 system의 자동화는 거의 이 루어지지 않고 있으며, 자동화된 진공판련 system은 거의 대부분 수입에 의흔하고 있다. 실험 실 규모에서부터 System올 하나하나 개밭하고, 이톨 자동화하는 노력과 일이 진행됨다면 산업 응용에 있어서도 자연스럽게 자동화된 system으$\mid$ 개발이 이루어 질 것이다 .. system 자동화는 상 품수명의 단축과 이에 따른 다품종 소량을 요구하는 시장수요에 대응하고, 인력절감과 고풀짙 화로 생산성 향상의 요구에 대응하기 위하여 필요하다. 본 연 구에 서 는 e-beam evaporator로 evaporation하면 서 ion beam으로 assist하여 thin film율 제 작하는 IBAD vacuum system율 싫 계 및 제 작하고[1,2], PLC[3,떼톨 이 용하여 system 자동화톨 하였다 .. thin film 제작 process는 먼저 기본 진공상태로 만뚫고 난 뒤, e-beam evaporator로 e evaporation하면서 ion beam source로 assist하여 substrate 011 thin film율 제조한다 226;. thin film올 제 조하면서 thickness monitor로 sample의 thickness rate톨 control 하고, sample의 균얼성과 밀착 성을 고려하여 substrate톨 rotation 및 heating 할 수 있도록 싫계, 제작하였다. 양질의 박막올 제조하기 위해서 진공환경이 좋은 상태로 제공되어야 한다. 이톨 위하여 oil free operation 0 I 가 능한 dry pump와 turbo molecular pump로 고진공 배기 하였다. 진공도의 흑점은 thermal effect 툴 고려하여 cold cathode ion gauge률 사용하였고, intro chamber와 main chamber 사이에는 g gate valve톨 설치하여 벌도로 운용되도록 하였다. 이러한 process를 박막의 두께, 진공도, 시 간, 온도, 공정 동의 조건올 기훈으로 자동화한 것이다. 또한 정전과 단수에 대한 interlock 기능 도 고려하였다.하였다.

  • PDF

RADIATION MONITORING SYSTEM FOR ADVANCED SPENT FUEL CONDITIONING PROCESS FACITLITY

  • Kook Dong-Hak;Choung Won-Myung;Lee Eun-Pyo;You Gil-Sung;Cho Il-Je;Kwon Kie-Chan;Lee Won-Kyoung;Ku Jeoung-Hoe
    • 한국방사성폐기물학회:학술대회논문집
    • /
    • 한국방사성폐기물학회 2005년도 Proceedings of The 6th korea-china joint workshop on nuclear waste management
    • /
    • pp.149-155
    • /
    • 2005
  • The $ACP^1$ is under development for effective management of spent fuel by converting $UO_2$ into U-metal. For demonstration of this process, $\alpha-\gamma$ type new hotcell was built in the $IMEF^2$ basement. To secure against radiation hazard, this facility needs radiation monitoring system which will observe the entire operating area before the hotcell and service area at back of it. This system consists of 7 parts; Area Monitor for $\gamma$-ray, Room Air Monitor for particulate and iodine in both area, Hotcell Monitor for hotcell inside high radiation and rear door interlock, Duct Monitor for particulate of outlet ventilation, Iodine Monitor for iodine of outlet duct, CCTV for watching workers and material movement, Server for management of whole monitoring system. After installation and test of this, radiation monitoring system will be expected to assist the successful ACP demonstration.

  • PDF