• 제목/요약/키워드: Interferometer Technique

검색결과 159건 처리시간 0.023초

Guided-Wave Tomographic Imaging of Plate Defects by Laser-Based Ultrasonic Techniques

  • Park, Junpil;Lim, Juyoung;Cho, Younho
    • 비파괴검사학회지
    • /
    • 제34권6호
    • /
    • pp.435-440
    • /
    • 2014
  • Contact-guided-wave tests are impractical for investigating specimens with limited accessibility and rough surfaces or complex geometric features. A non-contact setup with a laser-ultrasonic transmitter and receiver is quite attractive for guided-wave inspection. In the present work, we developed a non-contact guided-wave tomography technique using the laser-ultrasonic technique in a plate. A method for Lamb-wave generation and detection in an aluminum plate with a pulsed laser-ultrasonic transmitter and Michelson-interferometer receiver was developed. The defect shape and area in the images obtained using laser scanning, showed good agreement with the actual defect. The proposed approach can be used as a non-contact online inspection and monitoring technique.

Sagnac 간섭계형 광섬유 전류센서의 안정화 연구 (A study on stabilization of a fiber-optic current sensor using sagnac interferometer)

  • 정래성;강현서;이종훈;송정태;이경식
    • 전자공학회논문지D
    • /
    • 제34D권4호
    • /
    • pp.94-99
    • /
    • 1997
  • A new method of stbilizing the sagnac interferometric fiber optic current sensor inteh presence of birefringences and phase is presented. This method is realized by dividing the output of the ac current signal with the modulation signal output. Using the technique the stability of the current sensor was improve dmore than 4.5 times at 800Arms for 2 hours. The current sensor also shows good linearity up to 100Arms.

  • PDF

백색광 간섭계를 이용한 안구 돌출 값 측정 (Exophthalmometric values using White-light Scanning Interferometer)

  • 장중수;김영길
    • 한국정보통신학회논문지
    • /
    • 제21권12호
    • /
    • pp.2341-2346
    • /
    • 2017
  • 안와 내에서 안구의 상대적 위치는 여러 병적인 상태를 짐작할 수 있는 하나의 기준이 될 수 있다. 특히 안와골절, 갑상선 안질환, 안와 종양 등의 진단과 이에 약물 및 수술적 치료의 결과를 판단하는데 유용하다. 현재 안구 돌출 값을 측정하기 위해 주로 사용되는 대표적 측정 기기인 Hertel과 Naugle 안구돌출계 등은 검사자가 다를 경우, 같은 검사자가 반복적으로 측정하더라도 검사할 때마다 안와의 고정부위가 달라지는 등 측정자에 의한 오차가 필연적이다. 또한 동일한 안구 돌출 계라고 하더라도 제조 회사가 다르다면 안와의 고정부위 디자인이 달라 검사자에의한 측정 오차가 발생한다. 본 논문에서는 안구돌출값의 측정을 3차원 영상 측정기술인 백색광 간섭계를 이용하여 검사 정밀도 및 반복 정도를 크게 올릴 수 있는 자동 측정 방법에 대한 연구를 제안하고자 한다.

광섬유 패치코드를 이용한 Fabry-Perot 간섭계 온도센서 (Temperature Sensor Based on Fabry-Perot Interferometer Using a Fiber Optic Patch Cord)

  • 김주하;정은주;김명진;황성환;이우진;김계원;안종배;최은서;노병섭
    • 센서학회지
    • /
    • 제23권2호
    • /
    • pp.110-113
    • /
    • 2014
  • In this paper, we propose and demonstrate a Fabry-Perot interferometer (FPI) optical fiber tip sensor fabricated by a blade-sawing technique using a fiber optic patch cord for high-resolution temperature measurement. The sensor head consists of a short air FP cavity near the tip of a single-mode fiber patch cord tip. The temperature which we can measure is determined through a phase variation of the interference fringes in the reflective spectrum of the sensor. The fiber optic FPI sensor in this work can monitor the environmental temperature very accurately from 40 to $120^{\circ}C$. As a result, the temperature sensitivity is obtained as $38.2pm/^{\circ}C$.

위상 카드와 간섭계를 이용한 광학적 보안 시스템 (Optical Security System Using Phase Mask and Interferometer)

  • 김종윤;김기정;박세준;김철수;배장근;김정우;김수중
    • 대한전자공학회논문지SD
    • /
    • 제38권1호
    • /
    • pp.37-43
    • /
    • 2001
  • 본 논문에서는 컴퓨터와 리소그라피를 이용하여 암호화된 두 개의 위상카드를 제작하고, 마흐-젠더 간섭계를 이용하여 암호화된 이진영상을 복호화하는 방법을 제안하였다. 이때 두 위상카드 중 하나는 기준 영상으로 사용되고 다른 하나는 암호 영상으로 사용된다. 하나의 랜덤 위상 카드를 기준 영상으로 두고 암호화하고자 하는 영상에 맞게 빛의 간섭 현상을 이용하여 암호 영상으로 사용될 위상 카드를 제작하였다. 원 영상의 복원은 경로차가 같도록 구성한 마흐-젠더 간섭계의 두 경로에 기준 영상과 암호 영상을 위치시켜 간섭시킴으로써 영상을 복원할 수 있다. 위상 카드는 광세기 검출기로 볼 수 없을 뿐만 아니라 복제할 수도 없어서 개인 정보보호 및 인증시스템에 매우 유용하게 사용될 수 있다. 간단한 영상에 대한 광실험을 통하여 제안한 시스템의 타당성을 확인하였다.

  • PDF

레이저 간섭계를 이용한 적층 마이크로 외팔보의 고유진동수 측정 (Measurement on the Natural Frequency of a Laminated Cantilever Microbeam using a Laser Interferometer)

  • 김윤영;한봉구
    • 한국전산구조공학회논문집
    • /
    • 제31권1호
    • /
    • pp.17-21
    • /
    • 2018
  • 오늘날까지 적층 마이크로 외팔보의 고유진동수에 대하여 연구가 진행되었다. 마이크로 보는 실리콘 재질로 만들어 지지만, 그것의 상하 표면은 얇은 금 박막층(~30nm)이 증착되어 있다. 초음파 검사를 위해 초음파 테스트 플랫폼을 사용했으며, 시간영역 신호는 광학적으로 측정되었다. 고유진동수는 파형을 고속 Fourier 변환을 통해 정량화하였으며, 결과적으로 고전적인 보 이론과 일치하는 결과를 보여 주었다. 본 연구는 마이크로/나노스케일 재료와 마이크로 구조에 대한 동적평가기법을 제공할 것으로 기대된다.

비파괴검사를 위한 연속형 테라헤르츠 파 기반의 영상화 기술 (Imaging Technique Based on Continuous Terahertz Waves for Nondestructive Inspection)

  • 오경환;김학성
    • 센서학회지
    • /
    • 제27권5호
    • /
    • pp.328-334
    • /
    • 2018
  • The paper reviews an improved continuous-wave (CW) terahertz (THz) imaging system developed for nondestructive inspection, such as CW-THz quasi-time-domain spectroscopy (QTDS) and interferometry. First, a comparison between CW and pulsed THz imaging systems is reported. The CW-THz imaging system is a simple, fast, compact, and relatively low-cost system. However, it only provides intensity data, without depth and frequency- or time-domain information. The pulsed THz imaging system yields a broader range of information, but it is expensive because of the femtosecond laser. Recently, to overcome the drawbacks of CW-THz imaging systems, many studies have been conducted, including a study on the QTDS system. In this system, an optical delay line is added to the optical arm leading to the detector. Another system studied is a CW-THz interferometric imaging system, which combines the CW-THz imaging system and far-infrared interferometer system. These systems commonly obtain depth information despite the CW-THz system. Reportedly, these systems can be successfully applied to fields where pulsed THz is used. Lastly, the applicability of these systems for nondestructive inspection was confirmed.

수직평판을 삽입한 개구부의 헬륨 및 공기 치환류 (Helium-Air Exchange Flow Through Openings with Vertical Partitions)

  • 강태일
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제24권3호
    • /
    • pp.79-87
    • /
    • 2000
  • This paper describes experimental investigations of helium-air exchange flow through openings with vertical partitions. Such exchange flows may occur following rupture accident of stand pipe in high temperature gas cooled reactor. Exchange flow rates are investigated experimentally by using partitioned opening and opening with extended partition to assess fluids interference of the exchange flow at the stand pipe rupture accident. A tests vessel with the two types of opening on top of test cylinder is used in the experiments. An estimation method of mass increment is developed and applied to measure the exchange flow rate. A technique of flow visualization by Mach-Zehnder interferometer is provided to recognize the exchange flows. Amplitude and progress of interference fringes of the flows are observed and used as a support in comparison with the exchange flow rates. Flow passages of upward flow of the helium and downward flow of the air for both two types of the opening are separated by inserted partition within the opening, but in the case of partitioned opening, unseparated flow is formed at the opening entrance and the two flows interface. The exchange flow rate for the partitioned opening is not greater than that of the opening with extended partition because of the fluids interference at the entrance of opening. Finally, the fluids interference at the opening entrance is found to be one of important factors on the helium-air exchange flow rate.

  • PDF

유체간섭을 동반하는 헬륨과 공기의 치환류 (Helium-Air Exchange Flow with Fluids Interaction)

  • T.I. Kang
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제21권4호
    • /
    • pp.372-380
    • /
    • 1997
  • This paper describes experimental investigations of helium-air exchange flows through parti¬tioned opening and two-opening. Such exchange flows may occur following rupture accident of stand pipe in high temperature gas cooled reactor. A test vessel with the two types of small open¬ing on top of test cylinder is used for experiments. An estimation method of mass increment is developed and applied to measure the exchange flow rate. A technique of flow visualization by Mach-Zehnder interferometer is provided to recognize the exchange flows. In the case of exchange flow through the partitioned opening, flow passages of upward flow of the helium and downward flow of the air within the opening are separated by vertical partition, and the two flows interact out of entrance and exit of the opening. Therefore, an experiment of the exchange flow through two-opening is made to investigate effect of the fluids interaction of the partitioned opening sys¬tem. As a result of comparison of the exchange flow rates between the two types of the opening system, it is found that the exchange flow rate of the two-opening system is larger than that of the partitioned opening system due to absence of the effect of fluids interaction. Finally, the fluids interaction between the upward and downward flows through the partitioned opening is found to be an important factor on the helium-air exchange flow.

  • PDF

평판형 광-바이오센서용 2차원 광자결정 제작을 위한 Dip-Pen Nanolithography 공정 연구 (A Study on Dip-Pen Nanolithography Process to fabricate Two-dimensional Photonic Crystal for Planar-type Optical Biosensor)

  • 김준형;이종일;이현용
    • 한국전기전자재료학회논문지
    • /
    • 제19권3호
    • /
    • pp.267-272
    • /
    • 2006
  • Optical waveguide based on symmetric and asymmetric Mach-Zehnder interferometer(MZI) type was designed, fabricated and measured the optical characteristics for the application of biosensor. The wavelength of the input optical signal for the device was 1550 nm. And the difference of refractive index was $0.45\;{\Delta}\%$ between core and cladding of the device. The TM(Transverse Magnetic) mode optical properties of the biosensor were analyzed with the refractive index variation of gold thin film deposited for overclad. Nowadays, nano-photonic crystal structures have been paied much attention for its high optical sensitivity. There is a technique to realize the structure, which is called Dip-Pen Nanolithography(DPN) process. The process requires a nano-scale process patterning resolution and high reliability. In this paper, two dimensional nano-photonic crystal array on the surface was proposed for improving the sensitivity of optical biosensor. And the Dip-Pen Nanolithogrphy process was investigated to realize it.