• Title/Summary/Keyword: Interference examination

Search Result 51, Processing Time 0.023 seconds

Pain Disability of Orofacial Pain Patients (구강안면통증 환자의 통증활동제한)

  • Choi, Se-Heon;Kim, Ki-Suk;Kim, Mee-Eun
    • Journal of Oral Medicine and Pain
    • /
    • v.34 no.2
    • /
    • pp.217-225
    • /
    • 2009
  • As Pain is a comprehensive, biopsy chosocial phenomenon, improved understanding and successful management of pain need assessment of health-related quality of life and psychological states. The purpose of this study was to evaluate pain severity and pain-related interference to daily lives for patients with non-dental, orofacial pain(OFP) and a possible relation of OFP with psychological morbidity. Relation with such factors as gender, age, pain duration and diagnosis was also assessed. Inclusion criteria was all new patients with non-dental OFP attending the oral medicine.orofacial pain clinic of Dankook University Dental Hospital over 3 months' period, who completed the questionnaires of the Brief Pain Inventory (BPI) and Hospital Anxiety and Depression Scale (HADS). Prior to the first consultation, the patients were asked to fill out the questionnaire in the waiting room and were diagnosed through consultation and clinical examination. Total subjects were 163 with M:F ratio of 1:1.5 and mean age of 34.6${\pm}$17.7 years. Mean duration of pain was 13.3${\pm}$26.2 months and all patients were divided into; Trigeminal Neuralgia group (TN, N=8), Neuropathic Pain group (NeP, N=9), Persistent Idiopathic Facial Pain group (PIFP, N=8), and Temporomandibular Disorders group (TMD, N=138), subdivided into muscle problem (TMD-m, N=73), joint problem (TMD-j, N=24) and muscle-joint combined problem (TMD-c, N=41). OFP patients showed moderate pain severity and moderate pain-related interference. There was no gender difference in overall pain severity and interference and levels of anxiety and depression. Elderly patients aged ${\geq}$ 60 years showed higher pain severity (p<0.05). Patients with chronic pain ${\geq}$ 3 months reported more increased level of anxiety and depression than those with acute pain (p<0.05). Compared to TMD patients, patients with TN, NeP and PIFP suffered from higher level of pain and pain-related interference and reported higher level of anxiety and depression (p<0.05). Pain interference was closely correlated with their pain severity and with psychometric properties such as anxiety and depression. Pain severity was weakly correlated with levels of anxiety and depression. The results suggest a need for psychosocial assessment and support for successful management of OFP in addition to control of pain itself.

A Study on Electromagnetic Standards Changes of Vehicles (자동차 전자파 시험규격 변천사)

  • Woo, Hyungu
    • Journal of Auto-vehicle Safety Association
    • /
    • v.13 no.2
    • /
    • pp.7-14
    • /
    • 2021
  • Recently, the amount of electrical and electronic systems is increasing rapidly with the development of advanced vehicles such as ADAS, smart cars, connected cars, automated driving systems. It is necessary to examine the electromagnetic compatibility of vehicles equipped with those systems. The standards and regulations for examination of electromagnetic compatibility have been established and revised according to newly introduced electrical and electronic systems. They are administered in some different international standard associations such as ISO, CISPR, UN/ECE and are somewhat complex and bulky. In the study, the improvements and changes in them are tracked and analyzed chronologically. Research of the history of them will be helpful for understanding progress and forecasting the direction of development.

Advanced Energy Detector with Correlated Multiple Antennas

  • Kim, Sungtae;Lim, Sungmook
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.15 no.12
    • /
    • pp.4600-4616
    • /
    • 2021
  • In cognitive radio networks where unlicensed secondary users opportunistically access to licensed spectrum unused by licensed primary users, spectrum sensing is one of the key issues in order to effectively use the frequency resource. For enhancing the sensing performance in energy detection-based spectrum sensing, spatial diversity based on multiple antennas is utilized. However, the sensing performance can be degraded when antennas are spatially correlated, resulting in inducing the harmful interference to primary users. To overcome this problem, in this paper, an advanced energy detector is proposed. In the proposed sensing method, a weight matrix based on the eigenvalues of the spatial channels without any prior information on the primary signals is defined and utilized. In numerical simulations, it is shown that the proposed detector outperforms the conventional detector with regard to false-alarm and detection probabilities when antenna are spatially correlated.

A Case of Neurogenic Bladder Patient with Lumbar Disc Herniation (요추간판탈출증(腰椎間板脫出症)과 동반한 신경인성(神經因性) 방광(膀胱) 치험(治驗) 1례(例))

  • Kim, Sung-Nam;Lim, Jeong-A;Lee, Sung-Yong;Yun, Jong-Min;Choi, Sung-Yong;Kim, Hong-Hoon;Moon, Hyung-Cheol;Kim, Sung-Chul
    • Journal of Acupuncture Research
    • /
    • v.22 no.4
    • /
    • pp.155-163
    • /
    • 2005
  • Objectives : This is a clinical report about neurogenic bladder patient with lumbar disc hernication. Neurogenic bladder is a dysfunction that results from interference with the normal nerve pathways associated with urination. Hypotonic (flaccid) neurogenic bladder can be caused by ruptured or herniated intervertebral disk. Methods : The patient was treated by Oriental medicine treatment with needle acupuncture, electropuncture, bee venom acua-acupuncture and Daeboonchungeum-gami etc. Voided volume and frequency, visual analogue scale and physical examination was used to estimate the efficacy of these treatment. Results : STZ As using these treatments, voided volume and frequency returns normal condition. Visual analogue scale dips as low as 2. Physical examination showed improvement as compared with the fist visit. And further, these treatment may influence on the recovery of neurogenic bladder patient with lumbar disc herniation. Conclusion : The results suggest that Oriental medicine treatment have an useful effect on neurogenic bladder patient's treatment and recovery.

  • PDF

Idiopathic Postganglionic Horner's Syndrome in Dogs : 3 cases (개의 특발성 절후성 Horner's syndrome 3례)

  • Kim, Se-Eun;Park, Shin-Ae;Jeong, Man-Bok;Yi, Na-Young;Kim, Won-Tae;Chae, Je-Min;Seo, Kang-Moon
    • Journal of Veterinary Clinics
    • /
    • v.24 no.3
    • /
    • pp.441-443
    • /
    • 2007
  • Horner's syndrome is a group of clinical signs that results from interference with the sympathetic innervation of the globe and adnexa. Three dogs were presented with unilateral ptosis, miosis, enophthalmos and protrusion of the third eyelid. There were no other clinical signs on physical and neurological examination. On ophthalmic examination, the symptomatic eyes were diagnosed as Horner's syndrome. In order to localize the site of the lesion, pharmacological testing was performed through assessment of ocular response to the topical administration of 10% phenylephrine and clinical signs were resolved within 20 minutes. The pharmacological testing suggested that the deficit could be at the postganglionic neuron. Total resolution of clinical signs was observed within 6 months after their initial appearance without any treatment.

Composite Fracture Detection Capabilities of FBG Sensor and AE Sensor

  • Kim, Cheol-Hwan;Choi, Jin-Ho;Kweon, Jin-Hwe
    • Composites Research
    • /
    • v.27 no.4
    • /
    • pp.152-157
    • /
    • 2014
  • Non-destructive testing methods of composite materials are very important for improving material reliability and safety. AE measurement is based on the detection of microscopic surface movements from stress waves in a material during the fracture process. The examination of AE is a useful tool for the sensitive detection and location of active damage in polymer and composite materials. FBG (Fiber Bragg Grating) sensors have attracted much interest owing to the important advantages of optical fiber sensing. Compared to conventional electronic sensors, fiber-optical sensors are known for their high resolution and high accuracy. Furthermore, they offer important advantages such as immunity to electromagnetic interference, and electrically passive operation. In this paper, the crack detection capability of AE (Acoustic Emission) measurement was compared with that of an FBG sensor under tensile testing and buckling test of composite materials. The AE signals of the PVDF sensor were measured and an AE signal analyzer, which had a low pass filter and a resonance filter, was designed and fabricated. Also, the wavelength variation of the FBG sensor was measured and its strain was calculated. Calculated strains were compared with those determined by finite element analysis.

A Study on the Development of Controller which is used Electric Operating Cell(EOC) for Vacuum Circuit Breaker and the Controller Performance Certification Test (진공차단기용 전자식 보조접점 컨트롤러 개발 및 성능인증시험에 관한 연구)

  • Lee, Ki-Seon;Park, Jung-Cheul;Chu, Soon-Nam
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.64 no.3
    • /
    • pp.130-137
    • /
    • 2015
  • This study is about the controller development of the Electric Operating Cell(EOC) which will replace the Mechanical Operated Cell(MOC) of the vacuum circuit breaker which has been used in the power plant and the performance test for the developed controller. The controller developed through this study was manufactured considering the harsh installation environment and electrical condition of the power plant, and the controller performance certification test for confirming the product reliability was taken to know whether or not to withstand fully in various electrical and mechanical problems. Items for performance certification test were AC power frequency voltage withstand test, combined surge immunity test, 1 [MHz] oscillatory SWC test, fast transient SWC test, radiated electromagnetic interference test, vibration test. As a result, all tests has passed an examination without malfunction.

An Optimal Power-Throughput Tradeoff Study for MIMO Fading Ad-Hoc Networks

  • Yousefi'zadeh, Homayoun;Jafarkhani, Hamid
    • Journal of Communications and Networks
    • /
    • v.12 no.4
    • /
    • pp.334-345
    • /
    • 2010
  • In this paper, we study optimal tradeoffs of achievable throughput versus consumed power in wireless ad-hoc networks formed by a collection of multiple antenna nodes. Relying on adaptive modulation and/or dynamic channel coding rate allocation techniques for multiple antenna systems, we examine the maximization of throughput under power constraints as well as the minimization of transmission power under throughput constraints. In our examination, we also consider the impacts of enforcing quality of service requirements expressed in the form of channel coding block loss constraints. In order to properly model temporally correlated loss observed in fading wireless channels, we propose the use of finite-state Markov chains. Details of fading statistics of signal-to-interference-noise ratio, an important indicator of transmission quality, are presented. Further, we objectively inspect complexity versus accuracy tradeoff of solving our proposed optimization problems at a global as oppose to a local topology level. Our numerical simulations profile and compare the performance of a variety of scenarios for a number of sample network topologies.

Interference effect by electric utilities at electric resistivity Survey of fill dam (필댐의 전기비저항 탐사시 전기매체에 의한 영향 분석 연구)

  • Kim, Jae-Hong;Shin, Dong-Hoon;Im, En-Sang
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.1037-1040
    • /
    • 2009
  • Using much most electricity electric resistivity survey by nondestructiveness inquiry enforcement design of country base equipment business and facilities preservation administration dimension electric resistivity survey sends and cause much effects in survey believability by electricity medium of survey personality survey contiguity that grasp base special quality by potential difference flowing current artificially in base. Is item that enforce in most in-suite although when make electric resistivity survey until present, electricity medium or effect research by electricity origination was gone much. There is shortcoming that must be difficult to know correct underground utilities establishment state in-suite in this research and do comparison examination running parallel drilling investigation to heighten believability of electric resistivity survey. Did to dam that censure data that regulate grading from construction and is censure construction which can know correctly interior base situation comparatively to electricity medium of interior and electricity eruption won of contiguity and base condition (base rock).

  • PDF

Optical-fiber Electronic Speckle Pattern Interferometry for Quantitative Measurement of Defects on Aluminum Liners in Composite Pressure Vessels

  • Kim, Seong Jong;Kang, Young June;Choi, Nak-Jung
    • Journal of the Optical Society of Korea
    • /
    • v.17 no.1
    • /
    • pp.50-56
    • /
    • 2013
  • Optical-fiber electronic speckle pattern interferometry (ESPI) is a non-contact, non-destructive examination technique with the advantages of rapid measurement, high accuracy, and full-field measurement. The optical-fiber ESPI system used in this study was compact and portable with the advantages of easy set-up and signal acquisition. By suitably configuring the optical-fiber ESPI system, producing an image signal in a charge-coupled device camera, and periodically modulating beam phases, we obtained phase information from the speckle pattern using a four-step phase shifting algorithm. Moreover, we compared the actual defect size with that of interference fringes which appeared on a screen after calculating the pixel value according to the distance between the object and the CCD camera. Conventional methods of measuring defects are time-consuming and resource-intensive because the estimated values are relative. However, our simple method could quantitatively estimate the defect length by carrying out numerical analysis for obtaining values on the X-axis in a line profile. The results showed reliable values for average error rates and a decrease in the error rate with increasing defect length or pressure.