• 제목/요약/키워드: Interfacial Bonding Strength

검색결과 174건 처리시간 0.026초

치과용복합레진과의 결합에 있어, 상아질 내 교원섬유의 역할에 관한 연구 (TITLE : THE ROLE OF COLLAGEN FIBER IN DENTIN BONDING)

  • 박성호
    • Restorative Dentistry and Endodontics
    • /
    • 제22권1호
    • /
    • pp.470-478
    • /
    • 1997
  • The purpose of this study was to investigate the effects of moistening mechods of dentin on the morphologic states of hybrid layers and on the interfacial bond strength between dentin and composite. Specimens were divided into 6 groups based on the surface moistening methods and materials used. After the dentin surface was conditioned with 10 % phoporic acid and irrigated: 1. The dentin surface was dried. Then bonding agent and composite were applied. 2. The dentin surface was blot-dryed. Then primer, bonding atent and composite were applied. 3. The dentin surface was dryed first. Within 20 seconds, the surface was rewetted, then primer, bonding agent and composite were applied. 4. The dentin surface was dryed. Then primer, bonding agnent and composite were applied. 5. The dentin surface was dryed first. Atter 24hrs, the surface was rewetted, and then primer, bonding agent and composite were applied. 6. The surface was conditioned with NaOCl for 5min. Then primer, bonding agent and composite were applied. To reveal the hybrid layer, scanning electron microscopy was used after the samples were ion beam etched. The shear bond strength of each group was tom pared by ANOVA. In groups 2, 3 and 4, the hybrid layer was clearly visible, but the width was more limited in group 4. In group 1 and 5, the hybrid layer was not found, and a gap was formed between dentin and composite. In group 6, the hybrid layer was not found, but the interface between the dentin and composite was intimate. The shear bond strength of each group was as follows: Group 1 : 4MPa, Group 2 : 14MPa, Group 3 : 12MPa, Group 4 : 14MPa, Group 5 : 5MPa, Group 6 : 9MPa.

  • PDF

Cu-Cu 열압착 웨이퍼 접합부의 계면접합강도에 미치는 $N_2+H_2$ 분위기 열처리의 영향 (Effect of $N_2+H_2$ Forming Gas Annealing on the Interfacial Bonding Strength of Cu-Cu thermo-compression Bonded Interfaces)

  • 장은정;김재원;;;현승민;이학주;박영배
    • 마이크로전자및패키징학회지
    • /
    • 제16권3호
    • /
    • pp.31-37
    • /
    • 2009
  • 3차원 소자 집적을 위한 저온접합 공정 개발을 위해 Cu-Cu 열 압착 접합을 $300^{\circ}C$에서 30분간 실시하고 $N_2+H_2$, $N_2$분위기에서 전 후속 열처리 효과에 따른 정량적인 계면접착에너지를 4점굽힘시험법을 통해 평가하였다. 전 열처리는 100, $200^{\circ}C$$N_2+H_2$ 가스 분위기에서 각각 15분간 처리하였고, 계면접착에너지는 2.58, 2.41, 2.79 $J/m^2$로 전 열처리 전 후에 따른 변화가 없었다. 하지만 250, $300^{\circ}C$$N_2$ 분위기에서 1시간씩 후속 열처리 결과 2.79, 8.87, 12.17 $J/m^2$으로 Cu 접합부의 계면접착에너지가 3배 이상 향상된 결과를 얻을 수 있었다.

  • PDF

Interfacial Properties of Electrodeposited Carbon Fiber/Epoxy Composites using Electro-Micromechanical Techniques and Nondestructive Evaluations

  • Park, Joung-Man;Lee, Sang-Il
    • Macromolecular Research
    • /
    • 제9권1호
    • /
    • pp.20-29
    • /
    • 2001
  • Interfacial adhesion and nondestructive behavior of electrodeposited (ED) carbon fiber rein-forced composites were evaluated using electro-micromechanical techniques and acoustic emission (AE). The interfacial shear strength (IFSS) of the ED carbon fiber/epoxy composites was higher than that of the untreated fiber. This might be expected because of the possibility of chemical or hydrogen bonding in an electrically adsorbed polymeric interlayer. The logarithmic electrical resistivity of the untreated single-carbon fiber composite increased suddenly to infinity when fiber fracture occurred, whereas that of the ED composite increased relatively gradually to infinity. This behavior may arise from the retarded fracture time due to enhanced IFSS. In single- and ten-carbon fiber composites, the number of AE signals coming from interlayer failure of the ED carbon fiber composite was much larger than that of the untreated composite. As the number of the each first fiber fractures increased in the ten-carbon fiber composite, the electrical resistivity increased stepwise, and the slope of the logarithmic electrical resistance increased.

  • PDF

금속재와 폴리에틸렌 재료간의 접착강도 향상에 대한 연구 (A Study on the Improvement of Adhesive Strength of Between Metal and Polyethylene Materials)

  • 이지훈;김현주;정동호;이경엽
    • 한국정밀공학회지
    • /
    • 제24권12호
    • /
    • pp.143-148
    • /
    • 2007
  • Polyethylene is a typical hydrophobic material and it is difficult to bond the polyethylene material with metal material. Thus, it is important to modify the surface of polyethylene material to improve the bonding strength between the polyethylene and the metal materials. In this study, the surface modification of polyethylene material was investigated to improve the interfacial strength between the polyethylene and the steel materials. Polyethylene material was surface-modified in a plasma cleaner using an oxygen gas. Two cases of composites (surface-modified pelyethylene/steel composite and regular (as-received) pelyethylene/steel composite) were fabricated using a secondary bonding method. Shear and bending tests have been performed using the two cases of composites. The results showed that the contact angle did not change much as the modification time increased. However, the contact angle decreased from ${\sim}76^{\circ}\; to\;{\sim}41^{\circ}$ with the modification. The results also showed that the shear strength and the bending strength were improved about 3030 % and 7 %, respectively when the polyethylene was plasma-modified using an oxygen gas.

복합 재료로 구성된 축대칭 원판에서의 열응력 (Thermal Stresses in a Bimaterial Axisymmetric Disk-Approximate and Exact Solutions)

  • 정철섭;김기석
    • 전산구조공학
    • /
    • 제8권1호
    • /
    • pp.173-186
    • /
    • 1995
  • 2가지 이상의 재질로 결합된 구조물이 온도 변화를 받으면 열응력이 발생한다. 이러한 응력은 재질간의 열팽창계수가 서로 상이하여 생긴다. 본 논문에서는 균일한 온도변화를 받는 복합 재료로 이루어진 축대칭 원판(disk)에 대한 응력상태를 구하는 공식을 유도하였다. 먼저, 재료역학원리를 이용하여 근사해를 구한 후, Eigenfunction series를 전개하여 탄성학적인 정확해(Exact Solution)를 구하였다. 또한 정확해는 유한요소법으로 구한 해와 비교하였다. 상기 근사해로는 연계면에서의 응력분포를 예측하는 데 어려움이 있었으나, 정확해는 유한요소법으로 구한 결과와 대체로 일치하고 있어 응력분포를 충분히 예측할 수 있었다. 따라서, 본 논문에서 구한 정확해(Exact Solution) 공식은 복합재료로 구성된 구조물의 연계면에서의 응력분포를 결정하는 데 유용하다.

  • PDF

실란커플링제 처리가 폴리케톤섬유/에폭시 복합재료의 계면접착성 및 물성에 미치는 영향 (Effect of Silane Coupling Agent on the Interfacial Adhesion and Mechanical Properties of Polyketone Fiber Reinforced Epoxy Composites)

  • 조하니;양지우;임현수;오우진;이승구
    • 한국염색가공학회지
    • /
    • 제29권2호
    • /
    • pp.77-85
    • /
    • 2017
  • The interfacial adhesion between fiber and matrix affects the physical properties of fiber reinforced composites. In this study, 3-(Methacryloyloxy)propyltrimethoxy silane(MPS) coupling agent was used to increase the interfacial adhesion between polyketone fiber and epoxy resin. The change of surface chemical composition of polyketone fiber treated with MPS was analyzed using a FTIR-ATR. The interfacial bonding between fiber and resin increased with silane coupling agent largely. Consequently, interfacial shear strength(IFSS) was enhanced with increasing concentration of MPS coupling agent and thus, the physical properties of the composites such as flexural properties and dynamic mechanical properties were changed. Flexural strength and modulus increased when the MPS concentration was higher than 0.5wt%. The dynamic storage modulus of Polyketone/Epoxy composites treated with MPS was higher than that of the untreated one. When the MPS concentration of 3wt%, the highest storage modulus was obtained.

THIN FILM ADHESION IN Cu/Cr/POLYIMIDE AND Cu/Cu-Cr/POLYIMIDE SYSTEMS

  • Joh, Cheol-Ho;Kim, Young-Ho;Oh, Tae-Sung;Park, Ik-Sung;Yu, Jin
    • 한국표면공학회지
    • /
    • 제29권5호
    • /
    • pp.379-385
    • /
    • 1996
  • Adhesion of Cu/Cr and Cu/$Cu_xCr_{1-x}$ thin films onto polyimide substrates has been studied. For an adhesion layer, Cr or Cu-Cr alloy films were deposited onto polyimide using DC magnetron sputtering machine. Then Cu was sputter-deposited and finally, Cu was electroplated. Adhesion was evaluated using $90^{\circ}C$ peel test or T-peel test. Plastic deformation of the peeled metal layer was qualitatively measured using XRD technique. It is confirmed that high interfacial fracture energy and large plastic deformation are important to enhance the peel adhesion strength. High peel strength is obtained when the interface is strongly bonded. More ductile film has higher peel strength. In Cu-Cr alloy films, opposite effects of the Cr addition in the alloy film on the peel strength are operative: a beneficial effect of strong interfacial bonding and a negative effect of smaller plastic deformation.

  • PDF

Experimental study on damage and debonding of the frozen soil-concrete interface under freeze-thaw cycles

  • Liyun Tang;Yang Du;Liujun Yang;Xin Wang;Long Jin;Miaomiao Bai
    • Structural Engineering and Mechanics
    • /
    • 제86권5호
    • /
    • pp.663-671
    • /
    • 2023
  • Freeze-thaw cycles induce strength loss at the frozen soil-concrete interface and deterioration of bonding, which causes construction engineering problems. To clarify the deterioration characteristics of the interface under the freeze-thaw cycle, a frozen soil-concrete sample was used as the research object, an interface scanning electron microscope test under the freeze-thaw cycle was carried out to identify the micro index information, and an interface shear test was carried out to explore the loss law of interface shear strength under the freeze-thaw cycle. The results showed that the integrity of the interface was destroyed, and the pore number and pore size of the interface increased significantly with the number of freeze-thaw cycles. The connection form gradually deteriorates from surface-to-surface contact to point-to-surface contact and point-to-point contact, and the interfacial shear strength decreases the most at 0-3 freeze-thaw cycles, with small decreases from to 3-8 cycles. After 12 freeze-thaw cycles, the interfacial shear strength tends to be stable, and shear the failure occurs internally in the soil.

베릴륨이 포함되지 않은 도재용착용 비귀금속 합금과 세라믹간의 전단결합강도와 계면특성 (Shear Bond Strength and Interfacial Characterization of Ceramic to Beryllium Free Nonprecious Alloys for Porcelain Fused to Metal Crown)

  • 정인성;김치영
    • 한국콘텐츠학회논문지
    • /
    • 제10권11호
    • /
    • pp.228-234
    • /
    • 2010
  • 치과도재용 합금으로 사용되는 합금 중 베릴륨이 함유된 비귀금속 Ni-Cr합금과 베릴륨이 함유되지 않은 비귀금속 Ni-Cr합금 그리고 베릴륨이 함유되지 않은 비귀금속 Co-Cr 합금과 세라믹간의 결합강도와 파절양상 그리고 계면특성을 분석하고자 하였다. 결합강도는 만능시험기를 이용하여 전단력시험을 통하여 전단결합력을 측정하였으며, 전단시험에 의한 파단면을 이용하여 파절양상을 관찰하였다. 그리고 합금-도재간의 계면을 관찰하였다. 전단결합강도 측정 결과, 베릴륨이 포함된 T-3가 41.13(${\pm}5.11$)MPa로 가장 높게 나타났으며, 베릴륨이 포함된 VeraBond(40.72(${\pm}5.98$)MPa), Co-Cr 합금인 Wirobond(38.40(${\pm}9.66$)MPa), 베릴륨이 포함되지 않은 Verabond 2V(32.77(${\pm}4.31$)MPa), Bellabond N(28.63(${\pm}6.39$)MPa), Bellabond plus(24.97(${\pm}6.13$)MPa), Argeloy N.P. Star(22.69(${\pm}3.41$)MPa) 순으로 나타났다. 비귀금속 합금들과 세라믹간의 파절양상은 모든 시편에서 금속표면에 세라믹이 일부 부착된 복합파절(mixed failure) 양상을 보였다.

FRP 판용 쐐기형 정착구의 개발 (Development of Wedge-Type Mechanical Anchor for FRP Plate)

  • 조정래;박영환;박종섭;유영준;정우태;김철영
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 춘계 학술발표회 제16권1호
    • /
    • pp.80-83
    • /
    • 2004
  • The FRP plate or sheet bonding technology was widely used for strengthening deficient RC structures. The strengthened structure using FRP bonding scheme, however, experience the complex interfacial behaviour which is difficult to predict. Therefore, the unbonded scheme using some anchorage device can be is an alternative for more reliable design. In this study, wedge-type anchor for FRP plate is developed for the unbonded flexural strengthening scheme. Some parameter study using 2D finite element method is performed. The analysis parameters are taken as wedge-guide friction coefficients, wedge- FRP ,.friction coefficient and wedge inclination angle. Based on the parameter study, more efficient anchors are designed and tested. The test result show that the developed anchor assure about $80\%$ FRP strength, which is higher performance than typical bonding scheme. Last, 3D finite element analysis is performed.

  • PDF