• 제목/요약/키워드: Interface technique

검색결과 1,366건 처리시간 0.026초

Measurement of Brownian motion of nanoparticles in suspension using a network-based PTV technique

  • Banerjee A.;Choi C. K.;Kihm K. D.;Takagi T.
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2004년도 Proceedings of 2004 Korea-Japan Joint Seminar on Particle Image Velocimetry
    • /
    • pp.91-110
    • /
    • 2004
  • A comprehensive three-dimensional nano-particle tracking technique in micro- and nano-scale spatial resolution using the Total Internal Reflection Fluorescence Microscope (TIRFM) is discussed. Evanescent waves from the total internal reflection of a 488nm argon-ion laser are used to measure the hindered Brownian diffusion within few hundred nanometers of a glass-water interface. 200-nm fluorescence-coated polystyrene spheres are used as tracers to achieve three-dimensional tracking within the near-wall penetration depth. A novel ratiometric imaging technique coupled with a neural network model is used to tag and track the tracer particles. This technique allows for the determination of the relative depth wise locations of the particles. This analysis, to our knowledge is the first such three-dimensional ratiometric nano-particle tracking velocimetry technique to be applied for measuring Brownian diffusion close to the wall.

  • PDF

1800kW급 고주파 유도가열장치의 개발 (The Development of High-frequency Induction Heating with 1800kW Power)

  • 이광수;안일매;이영호;김용환;이현우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 F
    • /
    • pp.2064-2066
    • /
    • 1998
  • The development of the high-frequency induction-heating for 1800kW power range intend to make localization at forging and rolling mill part by technical innovation. And, the development makes to increase our's competitive power at technique, quality and cost. This paper describes the heart of high-frequency induction-heating technique, switching technique, a few problem in common using as an unsatisfied technique, load adjustment technique, system control, diagnostic system and auto-interface etc.

  • PDF

2700kW급 고주파 유도가열장치의 전원시스템 시뮬레이션 (Simulation of High-Frequency Induction-Heating Application Power Supply at 2700kW Power)

  • 이광수;고희석;이영호;이현우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부A
    • /
    • pp.189-191
    • /
    • 1998
  • The development of the high- frequency induction-heating for 2700kW power range intend to make localization at forging and rolling mill part by technical innovation. And, the development makes to increase our's competitive power at technique, quality and cost. This paper describes the heart of high-frequency induction-heating technique, switching technique, a few problem in common using as an unsatisfied technique, load adjustment technique, system control, diagnostic system and auto-interface etc.

  • PDF

An efficient modeling technique for floor vibration in multi-story buildings

  • Lee, Dong-Guen;Ahn, Sang-Kyoung;Kim, Jinkoo
    • Structural Engineering and Mechanics
    • /
    • 제10권6호
    • /
    • pp.603-619
    • /
    • 2000
  • Analysis of a framed structure for vertical vibration requires a lot of computational efforts because large number of degrees of freedom are generally involved in the dynamic responses. This paper presents an efficient modeling technique for vertical vibration utilizing substructuring technique and super elements. To simplify the modeling procedure each floor in a structure is modeled as a substructure. Only the vertical translational degrees of freedom are selected as master degrees of freedom in the inside of each substructure. At the substructure-column interface, horizontal and rotational degrees of freedom are also included considering the compatibility condition of slabs and columns. For further simplification, the repeated parts in a substructure are modeled as super elements, which reduces computation time required for the construction of system matrices in a substructure. Finally, the Guyan reduction technique is applied to enhance the efficiency of dynamic analysis. In numerical examples, the efficiency and accuracy of the proposed method are demonstrated by comparing the response time histories and the analysis time.

기/액, 고/액 2상 경계면에서의 수직와류의 성장과 소멸 (Development and Decay of Columnar Vortex in Two Phases Interface; Gas/Liquid, Solid/Liquid)

  • 김경훈;양시영;박만흥
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집E
    • /
    • pp.241-246
    • /
    • 2001
  • Vortices terminating at free surface have been investigated extensively. Most of investigations, however, are focused on surface parallel vortices and little has been known about surface normal vortex or columnar vortex. Visualized experimental results utilizing LIF technique are discussed for the purpose of characterization of columnar vortex interacting with a clean and a contaminated free surfaces and a solid body interface in the present investigation. The results reveal that surface tension changes due to surface contamination although bulk viscosity remains constant and eventually the behavior of a columnar vortex interacting with a contaminated free surface and a solid body interface are totally different from the clean free surface case.

  • PDF

비정렬 셀 중심방법 및 경계면포착법을 사용하는 3차원 유동해석코드(PowerCFD)에 적합한 HR 해법에 관한 연구 (STUDY ON HIGH RESOLUTION SCHEMES SUITABLE FOR AN 3-D CFD CODE(POWERCFD) USING UNSTRUCTURED CELL-CENTERED METHOD AND INTERFACE CAPTURING METHOD)

  • 명현국;김종은
    • 한국전산유체공학회지
    • /
    • 제13권1호
    • /
    • pp.7-13
    • /
    • 2008
  • Several high resolution schemes such as OSHER, MUSCL, SMART, GAMMA, WACEB and CUBISTA are comparatively studied with respect to the accurate capturing of fluid interfaces throughout the application to two typical test cases of a translation test and a collapsing water column problem with a return wave. It is accomplished by implementing the high resolution schemes in the in-house CFD code(PowerCFD) for computing 3-D flow with an unstructured cell-centered method and an interface capturing method, which is based on the finite-volume technique and fully conservative. The calculated results show that SMART scheme gives the best performance with respect to accuracy and robustness.

비정렬격자계에 적합한 경계면포착법에서의 HR 도식 비교연구 (Comparative Study on High Resolution Schemes in Interface Capturing Method Suitable for Unstructured Meshes)

  • 명현국
    • 대한기계학회논문집B
    • /
    • 제32권1호
    • /
    • pp.23-29
    • /
    • 2008
  • Two high resolution compressive schemes, CICSAM(Ubbink, 1997) and HRIC(Muzaferija & Peric, 1999), in interface capturing method are reviewed briefly with respect to the extended forms suitable for unstructured meshes. And then those are applied to three typical test cases of translation test, shearing flow test and collapsing water problem with an obstacle. It is accomplished by implementing the high resolution schemes in the in-house CFD code(PowerCFD) for computing 3-D flow with an unstructured cell-centered method, which is based on the finite-volume technique and fully conservative. The calculated results show that CICSAM is better than HRIC with respect to accuracy and robustness, although either scheme can be used as a good choice for free surface or two-phase flow simulation.

유한요소법에 의한 열화된 철근콘크리트 보의 보강성능평가 (Evaluation of Strengthening Capacity of Deteriorated RC Beams using Finite Element Method)

  • 이창훈;송하원;변근주
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 봄 학술발표회 논문집(I)
    • /
    • pp.756-761
    • /
    • 1999
  • The objective of this study is to develop finite element analysis technique to predict the strength reduction of deteriorated reinforced concrete beams and their strengthening capacity. In order to consider the effect of rebar corrosion, a tension stiffening model is proposed and area reduction of rebars due to corrosion is considered. For the analysis of strengthened deteriorated RC beams, one dimensional truss element and an interface element are introduced for models of the strengthening composite and the interface between concrete and composite to simulate delamination or discontinuous behavior at the interface. Then, analyses for deteriorated RC beams strengthened with glass fiber reinforced epoxy panel (GFREP) are carried out to predict both flexural failure and plate-end delamination failure. Finally, analysis results are verified with experimental results.

  • PDF

슬릿젯의 유동 및 냉각 성능에 대한 수치적 연구 (NUMERICAL ANALYSIS OF FLOW AND COOLING CHARACTERISTICS OF SLIT JETS IMPINGEMENT)

  • 손상일;손기헌;이필종;시성규
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2010년 춘계학술대회논문집
    • /
    • pp.448-450
    • /
    • 2010
  • Free surface liquid jet impingement, which is applicable to cooling of hot plates in a steel-making process, is investigated numerically by solving the conservation equations of mass, momentum and energy in the liquid and gas phases. The free-surface of liquid-gas interface is tracked by an improved level-set method incorporating a sharp-interface technique for accurate imposition of stress and heat flux conditions on the liquid-gas interface. The level-set approach is combined with a non-equilibrium $k-{\omega}$ turbulence model. The computations are made for slit nozzle jets to investigate their flow and cooling characteristics. Also, the effects of jetting angle, velocity and moving velocity of plate on the interfacial motion and the associated flow and temperature fields are quantified.

  • PDF

횡방향 등방성을 고려한 단섬유 인장 실험 모델링 (Modeling of Single Fiber Pull-Out Experiment Considering the Effects of Transverse Isotropy)

  • 설일찬;이춘열;채영석
    • 대한기계학회논문집A
    • /
    • 제26권7호
    • /
    • pp.1384-1392
    • /
    • 2002
  • Single fiber pull-out technique has been commonly used to characterize the mechanical behavior of interface in fiber reinforced composite materials. An improved analysis considering the effects of transversely isotropic properties of fiber and the effects of thermal residual stresses in both radial and axial directions along the fiber/matrix interface is developed for the single fiber pull-out test. Although the stress transfer properties across the interface is not much affected by considering the transversely isotropic properties of fiber, interfacial debonding is notably encouraged by the effect. The interfacial shear stress that plays an important role in interfacial debonding is very much affected by the component of axial thermal residual stress in the bonded region, which can induce a two-way debonding mechanism.