• 제목/요약/키워드: Interface standards

검색결과 285건 처리시간 0.024초

음성기반 멀티모달 인터페이스 및 표준 (Speech Based Multimodal Interface Technologies and Standards)

  • 홍기형
    • 대한음성학회지:말소리
    • /
    • 제51호
    • /
    • pp.117-135
    • /
    • 2004
  • In this paper, we introduce the multimodal user interface technology, especially based on speech. We classify multimodal interface technologies into four classes: sequential, alternate, supplementary, and semantic multimodal interfaces. After introducing four types of multimodal interfaces, we explain standard activities currently being activated.

  • PDF

Development of a Four-way Interface for Online Capillary Isoelectric Focusing-Electrospray-Mass Spectrometry (CIEF-ESI-MS)

  • Yu, Hai Dong;Kim, Byungjoo;Shin, Dae-Ho;Ahn, Seonghee
    • Mass Spectrometry Letters
    • /
    • 제4권4호
    • /
    • pp.83-86
    • /
    • 2013
  • A new interface for coupling CIEF and MS using a four-way cross has been developed in a single mechanical system. This new interface could be operated without the electric discontinuity and reinstallation of lines. Additionally, a bare fused silica capillary was facilitated as a spray needle to produce electrospray and to guide catholyte or sheath liquid. Focusing for CIEF was completed in a hanging droplet at the end of spray needle. This capillary spray needle also provided stable spray, enhanced the ionization efficiency and increased sensitivity. Results with carbonic anhydrase I showed that focusing and spraying were well completed with the new interface and the new spray needle.

고온초전도 SQUID 신호 검출을 위한 3채널용 FLL 회로 (Integrated 3-Channel Flux-Locked-Loop Electronics for the Readout of High-$T_c$ SQUID)

  • 김진목;김인선;유권규;박용기
    • Progress in Superconductivity
    • /
    • 제5권1호
    • /
    • pp.55-60
    • /
    • 2003
  • We designed and constructed integrated 3-channel flux-locked-loop (FLL) electronic system for the control and readout of high-T$_{c}$ SQUIDs. This system consists of low noise preamplifiers, integrators, interface circuits, and software. FLL operation was carried out with biased signals of 19 KHz modulated current and 150 KHz modulated flux, which are reconstructed as detected signals by preamplifier and demodulator. Computer controlled interface circuits regulate FLL circuit and adjust SQUID parameters to the optimum operating condition. The software regulates interface circuits to make an auto-tuning for the control of SQUIDs, and displays readout data from FLL circuit. 3-channel SQUID electronic system was assembled with 3 FLL-interface circuit boards and a power supply board in the aluminum case of 56 mm ${\times}$ 53 mm${\times}$ 150 mm. Overall noise of the system was around 150 fT/(equation omitted)Hz when measured in the shielded room, 200 fT/(equation omitted)Hz in a weakly shielded room, respectively.y.

  • PDF

Evaluation of the Functional and Non-functional Seat Sponge Effect in Sitting Chairs

  • Min, Seung Nam;Park, Se Jin;Subramaniyam, Murali;Lee, Heeran
    • 대한인간공학회지
    • /
    • 제33권4호
    • /
    • pp.255-265
    • /
    • 2014
  • Objective: The purpose of this study was to evaluate comfort levels of functional and non-functional chairs using subjective comfort rating, interface pressure measurement, muscle activity measurement, and skin temperature measurement. Background: Chairs are used for a prolonged period of time for sitting in many places such as the office, at university, at school, in industry, and so on. Almost all people use chairs in their everyday life. The functional properties of the chair are associated with comfort. Method: The subjective evaluation contains questions regarding chair comfort which can be rated with five point scale. The body-seat interface pressure was measured using a pressure mat system. The symmetry of sitting was measured using electromyography. The change in body part (thigh and buttock) temperature before and after sitting on a chair was measured with an infrared camera. Results: Participants rated significantly (p < 0.05) higher comfort scores for the functional chair in relation to the buttock and thigh region. Also, the participants felt a better cushion effect in the functional chair. When using the functional chair, lower interface pressure, better thermal comfort, and better symmetry of erector spinae muscle activity were observed. Conclusion: Overall, interface pressure measurement, muscle activity measurement, thermal imaging and subjective comfort score results showed that the functional chair was more comfortable than the non-functional chair. Application: The adopted methodologies could be used to measure the seating comfort of train seats.

The effect of surface treatment on interface formation between pentacene and polymer dielectrics

  • Han, Seung-Jin;Kim, Jae-Hoon;Park, Yong-Sup;Back, Kyu-Ha;Kim, Gi-Heon;Hong, Sa-Hwan;Kim, Dal-Hyun;Kim, Jeong-Won
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2007년도 7th International Meeting on Information Display 제7권2호
    • /
    • pp.1415-1418
    • /
    • 2007
  • Electronic and structural properties of the interfaces formed by pentacene deposited on a polymer-based dielectrics are investigated by electron spectroscopy, atomic force microscopy, and water contact angle measurement. There is strong influence of surface treatment of the polymer dielectrics on the energy level alignment and the surface topography upon the pentacene deposition.

  • PDF

A REVIEW ON DEVELOPING INDUSTRIAL STANDARDS TO INTRODUCE DIGITAL COMPUTER APPLICATION FOR NUCLEAR I&C AND HMIT IN JAPAN

  • Yoshikawa, Hidekazu
    • Nuclear Engineering and Technology
    • /
    • 제45권2호
    • /
    • pp.165-178
    • /
    • 2013
  • A comprehensive review on the technical standards about human factors (HF) design and software reliability maintenance for digital instrumentation and control (I&C) and human-machine interface technology (HMIT) in Japanese light water reactor nuclear power plants (NPPs) was given in this paper mainly by introducing the relevant activities at the Japan Electric Association to set up many industrial standards within the traditional framework of nuclear safety regulation in Japan. In Japan, the Fukushima Daiichi accident that occurred on March 11, 2011 has great impact on nuclear regulation and nuclear industries where concerns by the general public about safety have heightened significantly. However for the part of HF design and software reliability maintenance of digital I&C and HMIT for NPP, the author believes that the past practice of Japanese activities with the related technical standards can be successfully inherited in the future, by reinforcing the technical preparedness for the prevention and mitigation against any types of severe accident occurrence.

Decision of Interface and Depth Scale Calibration of Multilayer Films by SIMS Depth Profiling

  • Hwang, Hye-Hyun;Jang, Jong-Shik;Kang, Hee-Jae;Kim, Kyung-Joong
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제42회 동계 정기 학술대회 초록집
    • /
    • pp.274-274
    • /
    • 2012
  • In-depth analysis by secondary ion mass spectrometry (SIMS) is very important for the development of electronic devices using multilayered structures, because the quantity and depth distribution of some elements are critical for the electronic properties. Correct determination of the interface locations is critical for the calibration of the depth scale in SIMS depth profiling analysis of multilayer films. However, the interface locations are distorted from real ones by the several effects due to sputtering with energetic ions. In this study, the determination of interface locations in SIMS depth profiling of multilayer films was investigated by Si/Ge and Ti/Si multilayer systems. The original SIMS depth profiles were converted into compositional depth profiles by the relative sensitivity factors (RSF) derived from the atomic compositions of Si-Ge and Si-Ti alloy reference films determined by Rutherford backscattering spectroscopy. The thicknesses of the Si/Ge and Ti/Si multilayer films measured by SIMS depth profiling with various impact energy ion beam were compared with those measured by TEM. There are two methods to determine the interface locations. The one is the feasibility of 50 atomic % definition in SIMS composition depth profiling. And another one is using a distribution of SiGe and SiTi dimer ions. This study showed that the layer thicknesses measured with low energy oxygen and Cs ion beam and, by extension, with method of 50 atomic % definition were well correlated with the real thicknesses determined by TEM.

  • PDF

탄화규소계 세라믹스에서 미끄럼시의 마모 및 마모천이에 미치는 계면강도의 영향 (Effects of Interface Boundary Strength on Wear and Wear Transition during Sliding in Silicon Carbide Ceramics)

  • 김동진;박성길;류현;엄창도;조성재;김석삼
    • Tribology and Lubricants
    • /
    • 제11권4호
    • /
    • pp.21-27
    • /
    • 1995
  • The effects of interface boundary strength on wear and wear transition during sliding have been investigated in silicon carbide ceramics. Three different microstructures, i.e., solid state sintered silicon carbide, liquid phase sintered silicon carbide and liquid phase sintered silicon carbide composite reinforced with TiB$_{2}$ particulates, were designed by hot pressing. Examinations of crack patterns and fracture modes indicated that interface boundaries were relatively strong between silicon carbide grains in the solid state sintered silicon carbide, intermediate in the liquid phase sintered silicon carbide and weak between silicon carbide grains and TiB$_{2}$ particles in the composite. Wear data and examinations of worn surfaces revealed that the wear behavior of these silicon carbide ceramics could be significantly affected by the interface strength. In the solid state sintered silicon carbide, the wear occurred by a grooving process. In the liquid phase sintered silicon carbide and composite, on the other hand, an abrupt transition in wear mechanism from initial grooving to grain pull-out process occurred during the test. The transition occurred significantly earlier in the composite than in the carbide.

모바일 플랫폼 교육 콘텐츠 지원을 위한 손 글씨 기반 텍스트 인터페이스 설계 (Design of Handwriting-based Text Interface for Support of Mobile Platform Education Contents)

  • 조윤식;조세홍;김진모
    • 한국컴퓨터그래픽스학회논문지
    • /
    • 제27권5호
    • /
    • pp.81-89
    • /
    • 2021
  • 본 연구는 모바일 플랫폼 환경에서 언어 기반의 교육 콘텐츠 지원을 위한 텍스트 인터페이스를 제안한다. 이는 손 글씨를 통해 단어를 작성하는 입력 구조로 딥 러닝을 활용한다. 모바일 플랫폼 콘텐츠의 버튼, 메뉴 등을 활용한 GUI (Graphical User Interface)와 화면 터치, 클릭, 드래그 등의 입력 방식을 기반으로 손 글씨를 사용자로부터 직접 입력하여 처리할 수 있는 텍스트 인터페이스를 설계한다. 이는 EMNIST (Extended Modified National Institute of Standards and Technology database) 데이터 셋과 훈련된 CNN (Convolutional Neural Network)을 사용하여 알파벳 텍스트를 분류하고 조합하여 단어를 완성한다. 최종적으로 영어 단어 교육 콘텐츠를 직접 제작하여 제안하는 인터페이스의 학습 지원 효과를 분석하고 만족도를 비교하기 위한 실험을 진행한다. 동일한 교육 환경에서 기존의 키 패드 방식의 인터페이스와 제안하는 손 글씨 기반 텍스트 인터페이스를 서로 체험한 사용자들이 제시하는 영어 단어를 학습하는 능력을 비교하고, 인터페이스를 조작하여 단어를 작성하는 과정에서의 전체적인 만족도를 분석, 확인하도록 한다.

기체크로마토그래프-질량분석기의 실리콘 분리막 인터페이스의 유용성 연구 (Feasibility study of membrane interface for gas chromatograph-mass spectrometry)

  • 강길선;이동수;이화심;박창준
    • 분석과학
    • /
    • 제21권6호
    • /
    • pp.495-501
    • /
    • 2008
  • GC-MS 의 기존 인터페이스와 새로운 인터페이스의 차이점과 유용성을 판단하기 위하여 Agilent 5973 GC-MS의 capillary direct interface를 떼어내고 GC와 질량분석기 사이에 실리콘 membrane을 장착하여 membrane interface GC-MS의 분석 유용성을 조사하였다. 최대 $4.7m{\ell}/min$ 까지 헬륨 운반기체유량을 올릴 때 질량분석기의 진공도는 거의 영향을 받지 않으며, 피이크끌림 현상이 줄어들고 머무른시간이 줄어드는 빠른 분석을 보였다. Membrane 의 두께를 $127{\mu}m$에서 $75{\mu}m$으로 줄일 때 분리능이 향상 되며, membrane interface의 온도를 올릴 때 분리능과 감도가 향상되었다. 그러나 membrane interface GCMS는 질량/전하 비 73, 147에서 바탕이온이 발생하는 것과 기존의 capillary direct insertion interface보다 낮은 감도와 peak tailing에 의한 낮은 분리능의 문제점을 갖는다.