• 제목/요약/키워드: Interface parameter

검색결과 360건 처리시간 0.026초

대형구조물 구동계통 실시간 시뮬레이션 모델 유도 및 연동 특성 분석에의 응용 (A derivation of real-time simulation model on the large-structure driving system and its application to the analysis of system interface characteristics)

  • 김재훈;최영호;유웅재;유준
    • 한국군사과학기술학회지
    • /
    • 제3권1호
    • /
    • pp.13-25
    • /
    • 2000
  • A simulation model is developed to analyze the large-structure driving system and its integrated behavior in the whole weapon system. It models every component in the driving system such as mechanical and electrical characteristics, and it is programmed by simulation language in a way which strongly reflects the system's real time dynamics and reduces computation time as well. A useful parameter identification method is proposed, and it is tuned on the given physical system. The model is validated through comparing to real test, and it is applied to analysis and prediction of integrated system functions relating to the fire control system.

  • PDF

초내열합금의 대형마찰용접 공정해석 및 평가 (Evaluation and Process Analysis of the Superalloy Friction Welding for Large Shaft)

  • 정호승;김윤환;조종래;박희천;이낙규
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2004년도 추계학술대회논문집
    • /
    • pp.301-304
    • /
    • 2004
  • Friction welding was used to weld the turbine wheel and shaft and have a good welding quality. Friction welding was conducted an the two dissimilar material, Nimonic 80A and SNCrW. The control of friction welding process parameter such as flywheel energy, interface temperature, amount of upset have an effect on the mechanical properties of the welded joint. FE simulation can be a useful tool to optimize the weld geometry and process parameters. Flash shape and thickness weld is consistent with the simulated results. Process analysis was performed by the commercial code DEFORM 2D. Mechanical property of weld joints was evaluated by microstructure, chemical component, tensile, impact, hardness test so on.

  • PDF

풀리 제조공정의 셋업조건 결정을 위한 프로그램 설계 (Design of the Program for Determining Setup Conditions in Pulley Manufacturing Process)

  • 오봉훈;백재용;이규봉;김보현;장재덕
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.637-638
    • /
    • 2006
  • V-belt pulleys play a key role in driving cooling pump, oil pump, air-conditioner and so on by using an engine power. Precision deep drawing is one of the main processes for manufacturing the pulleys. Operation variables of the deep drawing equipment, called the setup parameter, must be re-determined whenever the specifications of pulley to be produced are changed. The defect rates during a setup of equipment and the working hours needed for the setup are almost dependent on workers' know-how. This study designs the program for easily determining setup conditions in pulley manufacturing process.

  • PDF

용접 계면균열의 크리프 균열성장 거동에 관한 연구 (A Study on Creep Crack Growth Behavior of Weld Interface Crack)

  • 윤기봉;김광웅;정용근
    • Journal of Welding and Joining
    • /
    • 제16권4호
    • /
    • pp.83-91
    • /
    • 1998
  • Cracking problems which high temperature plant components suffer during long-term service, occur very often at welded locations. The crack occurs due to accumulated creep damage near fusion line or at heat affected zone (HAZ). However, most of the studies on creep crack growth behavior have been performed with matrix metal not wit welded metal due to the difficulty of interpreting the test results. In this study, creep crack growth rates were measured with C(T) specimens whose cracks were formed along the fusion line or HAZ. The measured crack growth rates were characterized by {TEX}$C_{t}${/TEX}-parameter derived for elastic-primary-secondary creeping material. Since contribution of primary creep was significant for the tested 1Cr-0.5Mo steel, its effect was carefully studied. Effects of crack tip plasticity and material aging were also discussed.

  • PDF

Flexible Engineering Tool for Radiofrequency Parameter Identification of RF-MEMS BAW Filters

  • Mabrouk, Mohamed;Boujemaa, Mohamed-Ali;Choubani, Fethi
    • ETRI Journal
    • /
    • 제38권5호
    • /
    • pp.988-995
    • /
    • 2016
  • In this paper, we present a new specific and customized interface tool with parameter identification of Modified Butterworth-Van Dyke models for ladder bulk acoustic wave filters. The aforementioned tool is easy to use and flexible because it allows simulations and reengineering to be conducted in an application. A modular design approach is applied to simplify the extension of the proposed tool for different topologies. The proposed tool was validated using measurements from an aluminum-nitride based ladder BAW filter dedicated to the frequency ranges of the Universal Mobile Telecommunications Service and standards and Wideband Code Division Multiple Access.

강제대류 층류 막응축에서 복합열전달 (Conjugate Heat Transfer of Laminar Film Condensation Along a Horizontal Plate)

  • 이억수
    • 대한기계학회논문집B
    • /
    • 제30권3호
    • /
    • pp.238-245
    • /
    • 2006
  • This paper proposes appropriate conjugate parameters and dimensionless temperatures to analysis the conjugate problem of heat conduction in solid wall coupled with laminar film condensation flow adjacent to horizontal flat plate. An efficient methods for some fluids are proposed for its solution. The momentum and energy balance equations are reduced to a nonlinear system of ordinary differential equations with four parameters: the Prandtl number, Pr, Modified Jacob number, $Ja^*/Pr$, defined by an overall temperature difference, a property ratio $\sqrt{\rho_l{\mu}_l/{\rho_v{\mu}_v}$ and the conjugate parameter $\zeta$. The obtained similarity solution reveals the effect of the conjugate parameter, and the results are compared with the simplified solution. The variations of the heat transfer rates as well as the interface temperature and frictions along the plate are shown explicitly.

A Theory of Polymer Adsorption from Solution

  • Lee, Woong-Ki;Pak, Hyung-Suk
    • Bulletin of the Korean Chemical Society
    • /
    • 제8권1호
    • /
    • pp.19-26
    • /
    • 1987
  • A statistical thermodynamical treatment for polymer adsorption from solution is presented. The canonical partition function for the polymer solution in the presence of a surface or an impermeable interface is formulated on the basis of usual quasi-crystalline lattice model, Bragg-Williams approximation of random mixing, and Pak's simple treatment of liquid. The present theory gives the surface excess ${\Gamma}_{exc}$ and the surface coverage ${\phi}^s_2$ of the polymer as a function of the chain length x, the Flory-Huggins parameter x, the adsorption energy parameter $x_s$, and polymer concentration $v_2$. Present theory is also applicable to the calculation of interfacial tension of polymer solution against water. For the idealized flexible polymer, interfacial tensions according to our theory fit good to the experimental data to the agreeable degrees.

Interfacial properties of composite shotcrete containing sprayed waterproofing membrane

  • Park, Byungkwan;Lee, Chulho;Choi, Soon-Wook;Kang, Tae-Ho;Kim, Jintae;Choi, Myung-Sik;Jeon, Seokwon;Chang, Soo-Ho
    • Geomechanics and Engineering
    • /
    • 제16권4호
    • /
    • pp.385-397
    • /
    • 2018
  • This study evaluates the interfacial properties of composite specimens consisting of shotcrete and sprayed waterproofing membrane. Two different membrane prototypes were first produced and tested for their waterproofing ability. Then composite specimens were prepared and their interfacial properties assessed in direct shear and uniaxial compression tests. The direct shear test showed the peak shear strength and shear stiffness of the composites' interface decreased as the membrane layer became thicker. The shear stiffness, a key input parameter for numerical analysis, was estimated to be 0.32-1.74 GPa/m. Shear stress transfer at the interface between the shotcrete and membrane clearly emerged when measuring peak shear strengths (1-3 MPa) under given normal stress conditions of 0.3-1.5 MPa. The failure mechanism was predominantly shear failure at the interface in most composite specimens, and shear failure in the membranes. The uniaxial compression test yielded normal stiffness values for the composite specimens of 5-24 GPa/m. The composite specimens appeared to fail by the compressive force forming transverse tension cracks, mainly around the shotcrete surface perpendicular to the membrane layer. Even though the composite specimens had strength and stiffness values sufficient for shear stress transfer at the interfaces of the two shotcrete layers and the membrane, the sprayed waterproofing membrane should be as thin as possible whilst ensuring waterproofing so as to obtain higher strength and stiffness at the interface.

강유전체 BiFeO3가 증착된 TiO2 전극을 이용한 염료감응형 태양전지의 효율 향상 (Ferroelectric BiFeO3-coated TiO2 Electrodes for Enhanced Photovoltaic Properties of Dye-sensitized Solar Cells)

  • 주호용;홍수봉;이호상;전지훈;박배호;홍성철;최택집
    • 한국전기전자재료학회논문지
    • /
    • 제26권3호
    • /
    • pp.198-203
    • /
    • 2013
  • Dye-sensitized solar cells (DSSCs) based on titanium dioxide ($TiO_2$) have been extensively studied because of their promising low-cost alternatives to conventional semiconductor based solar cells. DSSCs consist of molecular dye at the interface between a liquid electrolyte and a mesoporous wide-bandgap semiconductor oxide. Most efforts for high conversion efficiencies have focused on dye and liquid electrolytes. However, interface engineering between dye and electrode is also important to reduce recombination and improve efficiency. In this work, for interface engineering, we deposited semiconducting ferroelectric $BiFeO_3$ with bandgap of 2.8 eV on $TiO_2$ nanoparticles and nanotubes. Photovoltaic properties of DSSCs were characterized as a function of thickness of $BiFeO_3$. We showed that ferroelectric $BiFeO_3$-coated $TiO_2$ electrodes enable to increase overall efficiency of DSSCs, which was associated with efficient electron transport due to internal electric field originating from electric polarization. It was suggested that engineering the dye-$TiO_2$ interface using ferroelectric materials as inorganic modifiers can be key parameter for enhanced photovoltaic performance of the cell.

Fundamental parameters of nanoporous filtration membranes

  • Wei Li;Xiaoxu Huang;Yongbin Zhang
    • Membrane and Water Treatment
    • /
    • 제14권3호
    • /
    • pp.115-120
    • /
    • 2023
  • The design theory for nanoporous filtration membranes needs to be established. The present study shows that the performance and technical advancement of nanoporous filtration membranes are determined by the fundamental parameter I (in the unit Watt1/2) which is formulated as a function of the shear strength of the liquid-pore wall interface, the radius of the filtration pore, the membrane thickness, and the bulk dynamic viscosity of the flowing liquid. This parameter determines the critical power loss on a single filtration pore for initiating the wall slippage, which is important for the flux of the membrane. It also relates the membrane permeability to the power cost by the filtration pore. It is shown that for biological cellular membranes its values are on the scale 1.0E-8Watt1/2, for mono-layer graphene membranes its values are on the scale 1.0E-9Watt1/2, and for nanoporous membranes made of silica, silicon nitride or silicon carbonized its values are on the scale 1.0E-5Watt1/2. The scale of the value of this parameter directly measures the level of the performance of a nanoporous filtration membrane. The carbon nanotube membrane has the similar performance with biological cellular membranes, as it also has the value of I on the scale 1.0E-8Watt1/2.