• Title/Summary/Keyword: Interface Correction

Search Result 137, Processing Time 0.032 seconds

LPG/CNG Interface Box Hardware Design (LPG/CNG Interface Box 제품 Hardware 설계)

  • An, Jeong-Hoon;Jung, Jae-Min
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.15 no.6
    • /
    • pp.23-29
    • /
    • 2007
  • In Korea, the number of LPG vehicles is increasing continuously because LPG is cheaper than Gasoline. Also in Europe, the CNG fuel is a good solution to meet $CO_2$ regulation. In order to use LPG/CNG fuel, new EMS ECU must be developed for every type of vehicles and it requires huge development cost. In order to reduce development cost and time, SIEMENS VDO has developed an Interface Box. It supports EMS ECU in the car and manages LPG/CNG fuel injection system. Basically the Interface box can be used with any kind of EMS ECU. The Interface Box controls LPG/CNG injector through the injection command of gasoline EMS ECU. It calculates required amount of based on the fuel temperature and pressure and sends feedback signal to ECU for fuel correction. Also, it controls LPG/CNG specific actuator such a Shut off valves and LPG switch inputs.

A Low-Complexity Real-Time Barrel Distortion Correction Processor Combined with Color Demosaicking (컬러 디모자이킹이 결합된 저 복잡도의 실시간 배럴 왜곡 보정 프로세서)

  • Jeong, Hui-Seong;Park, Yun-Ju;Kim, Tae-Hwan
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.9
    • /
    • pp.57-66
    • /
    • 2014
  • This paper presents a low-complexity barrel distortion correction processor for wide-angle cameras. The proposed processor performs the barrel distortion correction jointly with the color demosaicking, so that the hardware complexity can be reduced significantly. In addition, to reduce the required memory bandwidth, an efficient memory interface is proposed by utilizing the spatial locality of the memory access in the correction process. The proposed processor is implemented with 35K logic gates in a $0.11-{\mu}m$ CMOS process and its correction speed is 150 Mpixels/s at the operating frequency of 606MHz, where the supported frame size is $2048{\times}2048$ and the required memory bandwidth is 1 read/cycle.

Analysis of th estress intensity factor of mode I crack in a finite width plate with variable thickness (두께가 變化하는 有限幅板材에서의 모우드 I 龜裂 應力擴大係數 解析)

  • 양원호;방시항
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.11 no.1
    • /
    • pp.132-144
    • /
    • 1987
  • This paper presents the theroetical analysis of the crack tip stress intensity factor for a center crack in a finite width plate with variable thickness. The analyses were based on Laurent's expansions of complex stress potentials where the expansion coefficients are determined from the boundary conditions. The perturbation method was employed in numerical calculations. The correction factor F(.lambda.)is given in the form of power series of .lambda. [a numerical formula] where .lambda.=a/w$^{1}$; Dimensionless crack length, .betha.=t$_{2}$/t; Thickness ratio .omega.=w$_{2}$/w$_{1}$; width ratio The correction factor values vary with the width ratio .omega. and the maximum variation occurs around .betha.=1. For the case of .betha.=1 or .betha.=0 (uniform thickness plate0, the correction factor values agree well with Feddersen's formula. In all cases, as .lambda. approaches to 1 (thickness interface), the correction factor values are decreased rapidly for .betha.>1, and increased rapidly for .betha.<1.

Extraction of the atmospheric path radiance in relation to retrieval of ocean color information from the TM and SeaWiFS imageries

  • Ahn, Yu-Hwan;Shanmugam, P.
    • Proceedings of the Korean Association of Geographic Inforamtion Studies Conference
    • /
    • 2004.03a
    • /
    • pp.241-246
    • /
    • 2004
  • The ocean signal that reaches the detector of an imaging system after multiple interactions with the atmospheric molecules and aerosols was retrieved from the total signal recorded at the top of the atmosphere (TOA). A simple method referred to as 'Path Extraction' applied to the Landsat-TM ocean imagery of turbid coastal water was compared with the conventional dark-pixel subtraction technique. The shape of the path-extracted water-leaving radiance spectrum resembled the radiance spectrum measured in-situ. The path-extraction was also extended to the SeaWiFS ocean color imagery and compared with the standard SeaWiFS atmospheric correction algorithm, which relays on the assumption of zero water leaving radiance at the two NIR wavebands (765 and 865nm). The path-extracted water-leaving radiance was good agreement with the measured radiance spectrum. In contrast, the standard SeaWiFS atmospheric correction algorithm led to essential underestimation of the water-leaving radiance in the blue-green part of the spectrum. The reason is that the assumption of zero water-leaving radiance at 755 and 865nm fails due to backscattering by suspended mineral particles. Therefore, the near infrared channels 765 and 865nm used fur deriving the aerosol information are no longer valid for turbid coastal waters. The path-extraction is identified as a simple and efficient method of extracting the path radiance largely introduced due to light interaction through the complex atmosphere carried several aerosol and gaseous components and at the air-sea interface.interface.

  • PDF

Computation of Two-Fluid Flows with Submerged hydrofoil by Interface Capturing Method (접면포착법에 의한 수중익 주위의 이층류 유동계산)

  • 곽승현
    • Journal of Korean Port Research
    • /
    • v.13 no.1
    • /
    • pp.167-174
    • /
    • 1999
  • Numerical analysis of two-fluid flows for both water and air is carried out. Free-Surface flows with an arbitrary deformation have been simulated around two dimensional submerged hydrofoil. The computation is performed using a finite volume method with unstructured meshes and an interface capturing scheme to determine the shape of the free surface. The method uses control volumes with an arbitrary number of faces and allows cell-wise local mesh refinement. the integration in space is of second order based on midpoint rule integration and linear interpolation. The method is fully implicit and uses quadratic interpolation in time through three time levels The linear equation systems are solved by conjugate gradient type solvers and the non-linearity of equations is accounted for through picard iterations. The solution method is of pressure-correction type and solves sequentially the linearized momentum equations the continuity equation the conservation equation of one species and the equations or two turbulence quantities.

  • PDF

Computation of Water and Air Flow with Submerged Hydrofoil by Interface Capturing Method

  • Kwag, Seung-Hyun
    • Journal of Mechanical Science and Technology
    • /
    • v.14 no.7
    • /
    • pp.789-795
    • /
    • 2000
  • Free-surface flows with an arbitrary deformation, induced by a submerged hydrofoil, are simulated numerically, considering two-fluid flows of both water and air. The computation is performed by a finite volume method using unstructured meshes and an interface capturing scheme to determine the shape of the free surface. The method uses control volumes with an arbitrary number of faces and allows cell wise local mesh refinement. The integration in space is of second order, based on midpoint rule integration and linear interpolation. The method is fully implicit and uses quadratic interpolation in time through three time levels. The linear equations are solved by conjugate gradient type solvers, and the non-linearity of equations is accounted for through Picard iterations. The solution method is of pressure-correction type and solves sequentially the linearized momentum equations, the continuity equation, the conservation equation of one species, and the equations for two turbulence quantities. Finally, a comparison is quantitatively made at the same speed between the computation and experiment in which the grid sensitivity is numerically checked.

  • PDF

Design of a Serial Port Interface Suitable for Bluetooth Embedded Systems (블루투스 임베디드 시스템에 적용 가능한 직렬 포트 인터페이스 설계)

  • Moon, Sangook
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.05a
    • /
    • pp.903-906
    • /
    • 2009
  • In this contribution, we designed a serial port interface (SPI) suitable for embedded systems, especially for Bluetooth baseband. Proposed architecture is compatible for the APB bus in AMBA bus architecture. The 8-bit design of the SPI module is in charge of transferring the data and the instructions between the external devices and the coprocessors. We adopted the cyclic redundancy check method for the error correction. Also, we provided the interface for multimedia cards. The designed SPI module was automatically synthesized, placed, and routed. Implementation was performed through the Altera FPGA and well operated at 25MHz clock frequency.

  • PDF

Three-dimensional accuracy of different correction methods for cast implant bars

  • Kwon, Ji-Yung;Kim, Chang-Whe;Lim, Young-Jun;Kwon, Ho-Beom;Kim, Myung-Joo
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.1
    • /
    • pp.39-45
    • /
    • 2014
  • PURPOSE. The aim of the present study was to evaluate the accuracy of three techniques for correction of cast implant bars. MATERIALS AND METHODS. Thirty cast implant bars were fabricated on a metal master model. All cast implant bars were sectioned at 5 mm from the left gold cylinder using a disk of 0.3 mm thickness, and then each group of ten specimens was corrected by gas-air torch soldering, laser welding, and additional casting technique. Three dimensional evaluation including horizontal, vertical, and twisting measurements was based on measurement and comparison of (1) gap distances of the right abutment replica-gold cylinder interface at buccal, distal, lingual side, (2) changes of bar length, and (3) axis angle changes of the right gold cylinders at the step of the post-correction measurements on the three groups with a contact and non-contact coordinate measuring machine. One-way analysis of variance (ANOVA) and paired t-test were performed at the significance level of 5%. RESULTS. Gap distances of the cast implant bars after correction procedure showed no statistically significant difference among groups. Changes in bar length between pre-casting and post-correction measurement were statistically significance among groups. Axis angle changes of the right gold cylinders were not statistically significance among groups. CONCLUSION. There was no statistical significance among three techniques in horizontal, vertical and axial errors. But, gas-air torch soldering technique showed the most consistent and accurate trend in the correction of implant bar error. However, Laser welding technique, showed a large mean and standard deviation in vertical and twisting measurement and might be technique-sensitive method.