• Title/Summary/Keyword: Interface Assessment

Search Result 327, Processing Time 0.034 seconds

전력선통신 기반 A/V 신호 송수신기 설계 및 특성분석

  • Kim, Ji-Hyeong;Kim, Yong-Gap
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.285-285
    • /
    • 2009
  • Due to a development of a modem technology as Power Line Communication(PLC) over 200 Mbps, the high-speed multi-media data trasmission could be currently possible. In This paper we develop a high quality media transmitter-receiver based on merging the HomePlug AV, which is 200 Mbps class PLC technology and HDMI Interface technology. Smart Live 6 software were used for the assessment of audio property. As the result of measurement of the HD class images by capturing from the receiver of the PLC, the quality of images couldn't be confirm any deterioration, which has compared with original reflections. In case of audio part as the result of confirmation of the Phase, Magnitude, it has been confirmed that over 90% of nomal transmition and receiving of acoustic signal.

  • PDF

Development of a Platform to resolve the Mismatch between Job and Competence in Recruitment Market (채용시장 직무와 역량 간 미스매치 해소를 위한 플랫폼 개발)

  • Kim, Jongho
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.12 no.3
    • /
    • pp.11-24
    • /
    • 2016
  • The purpose of this study is to develop a recruiting platform resolving the mismatch between corporate job and job finder's competence in recruitment market. For this, we investigated technological trends and limitation on recruit platform. Based on the findings, this study investigates the trends and directions related to recruiting platform evolution and identified critical success factors and development strategies for successful development of recruiting platform. Two development strategies include employment of online resume and construction of database assessing job finder's competence. We also proposed target system architecture incorporating job database, competency assessment form, capability oriented resume. To analyze user requirement national competency standards and core job capability evaluation model were analyzed. Next, we designed integrated database, user interfaces, and dynamic functionalities using the forms developed in earlier stage. Finally, we assessed the fidelity of form item, integrity of database, and the usability of interface to evaluate the effectiveness of the system.

Transient Stability Analysis Based on OOP (객체지향기반 과도 안정도 해석)

  • Park, Ji-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.3
    • /
    • pp.354-362
    • /
    • 2008
  • This paper presents the new method of power system transient stability simulation, which combines the desirable features of both the time domain technique based on OOP(Object-oriented Programming) and the direct method of transient stability analysis using detailed generator model. OOP is an alternative to overcome the problems associated with the development, maintenance and update of large software by electrical utilities. Several papers have already evaluated this approach for power system applications in areas such as load flow, security assessment and graphical interface. This paper applied the object-oriented approach to the problem of power system dynamics simulation. The modeling method is that each block of dynamic system block diagram is implemented as an object and connected each other. In the transient energy method, the detailed synchronous generator model is so-called two-axis model. For the excitation model, IEEE type1 model is used. The developed mothed was successfully applied to New England Test System.

Engineering-scale Test for Validating the T-H-M Behavior of a HLW Repository: Experimental Set-up

  • Lee, Jae-Owan;Baik, Min-Hoon;Cho, Won-Jin
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2004.06a
    • /
    • pp.194-198
    • /
    • 2004
  • The thermo-hydro-mechanical (T-H-M) process is one of major issues in the performance assessment of a high level waste (HLW) repository. An engineering-scale test was planned and its experimental set-up has being installed, to validate the T-H-M behavior in the buffer of a reference disposal system. The experimental set-up consists of 4 major components: the confining cylinder with its hydration water tank, the bentonite block, the heating system, and the sensors and instruments. The monitoring and data acquisition system is employed to control the heater to maintain the temperature of $95^{\circ}C$ at the interface of the heater and bentonite blocks and to collect signals from sensors and instruments installed in the bentonite blocks.

  • PDF

Damage Assessment of Curved Composite Laminate Structures Subjected to Low-Velocity Impact (곡률을 가진 적층복합재 구조에서의 저속충격손상 평가)

  • 전정규;권오양
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2001.05a
    • /
    • pp.69-73
    • /
    • 2001
  • Damage induced by low-velocity impact on the curved composite laminates was experimentally evaluated for CFRP cylindrical shells with the radius of curvatures of 50, 150, 300, and 500 mm. The result was then compared with that of flat laminates. The radius of curvatures and the effective shell stiffness appeared to considerably affect the dynamic impact response of curved shells. Under the same impact energy level, the maximum contact force increased with the decreasing radius of curvatures, with reaching 1.5 times that for plates at the radius of curvature of 50 mm. Since the maximum contact force is directly related to the impact damage, curved laminates can be more susceptible to delamination and less resistant to the low-velocity impact damage. The distribution of delamination along the thickness direction of curved laminates are also different from that of flat plates. Delamination was distributed rather even]y at each interface along the thickness direction of curved laminates. This implies that the effect of curvatures has to be considered for the design of a curved composite laminate.

  • PDF

Including Thermal Effects in CFD Wind Flow Simulations

  • Meissner, Catherine;Gravdahl, Arne Reidar;Steensen, Birthe
    • Journal of Environmental Science International
    • /
    • v.18 no.8
    • /
    • pp.833-839
    • /
    • 2009
  • The calculation of the wind field for resource assessment is done by using CFD Reynolds-Averaged Navier-Stokes simulations performed with the commercial software WindSim. A new interface has been created to use mesoscale simulation data from a meteorological model as driving data for the simulations. This method makes it necessary to take into account thermal effects on the wind field to exploit the full potential of this method. The procedure for considering thermal effects in CFD wind field simulations as well as the impact of thermal effects on the wind field simulations is presented. Simulations for non-neutral atmospheric conditions with the developed method are consistent with expected behavior and show an improvement of simulation results compared with observations.

Design of Real-Time Dynamic Stability Assessment interface With EMS (EMS연동 실시간 동적안정도 평가기능 설계)

  • Seo, Eun-Sung;Hur, Sung-Il;Lee, Jin-Su;Lee, Gun-Woong
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.220-221
    • /
    • 2011
  • 2003년 미 북동부의 대정전 이후 온라인 동적안정도 평가기능은 계통의 실시간 상태와 상정사고시 상태를 이해하는데 많은 기관에서 채택하고 있다. 우리나라도 현재 한계수명이 다한 EMS를 대체할 차기EMS 시스템의 도입시 계통 해석과 감시에 많은 장점을 갖고 있는 온라인 동적안정도 평가 가능을 검토하여 계통해석의 빠르고 정확한 환경을 조성하려고 하고 있으며 온라인 동적안정도 평가 기능이 활용된다면 현재 계통운영상태에 대한 안정성 평가에 많은 향상이 이루어지리라본다.

  • PDF

A Study on the Strength Assessment of CFRP Laminate Plates by Drop-Weight Impact Test (낙추식 충격시험에 의한 CFRP 적층판의 강도평가에 관한 연구)

  • 이정주;박노식;양인영
    • Journal of the Korean Society of Safety
    • /
    • v.14 no.3
    • /
    • pp.12-17
    • /
    • 1999
  • In this study, a drop-weight impact tester was manufactured to assess the strength of CFRP laminate plates. The tests were conducted on several laminates of different ply orientation. A system for the impact strength of CFRP laminates was made considering stress wave propagation theory using drop-weight impact tester as one of impact test. Results indicate that absorbed energy of quasi-isotropic specimen, haying four interfaces is higher than that of orthotropic laminates with two interfaces. Absorbed energy in the specimen that ply number, interface number and fiber stacking sequences is same but having hybrid is higher than that of orthotropic laminates without hybrid.

  • PDF

A Survey of Usability and User-Centered Design Practice in IT Industry for Strategic Usability (IT 개발환경에서의 사용성 및 사용자 중심 설계의 전략적 접근을 위한 현황연구)

  • Ji, Yong-Gu
    • IE interfaces
    • /
    • v.17 no.4
    • /
    • pp.490-498
    • /
    • 2004
  • This paper reports results of a recent survey of 184 Information Technology (IT) development practitioners and 90 User Interface (UI)/usability practitioners. This survey covered a broad range of issues including the respondents' profile, current development environment, usability and user-centered design (UCD) adoption issues in IT development practice, overall assessment of usability/UCD, and the most widely used usability/UCD methods and techniques. The results of this study are expected to provide an empirical basis for usability and UCD planning, training, adoption and execution in IT industry.

Mesoscopic study on historic masonry

  • Sejnoha, J.;Sejnoha, M.;Zeman, J.;Sykora, J.;Vorel, J.
    • Structural Engineering and Mechanics
    • /
    • v.30 no.1
    • /
    • pp.99-117
    • /
    • 2008
  • This paper presents a comprehensive approach to the evaluation of macroscopic material parameters for natural stone and quarry masonry. To that end, a reliable non-linear material model on a meso-scale is developed to cover the random arrangement of stone blocks and quasi-brittle behaviour of both basic components, as well as the impaired cohesion and tensile strength on the interface between the blocks and mortar joints. The paper thus interrelates the following three problems: (i) definition of a suitable periodic unit cell (PUC) representing a particular masonry structure; (ii) derivation of material parameters of individual constituents either experimentally or running a mixed numerical-experimental problem; (iii) assessment of the macroscopic material parameters including the tensile and compressive strengths and fracture energy.