• Title/Summary/Keyword: Interface 평가

Search Result 1,861, Processing Time 0.029 seconds

A Study of Usability Evaluation and Improvement of Weapon System Display GUI Using Performance Model (Performance Model을 이용한 무기체계 운용화면 GUI 사용성 평가 및 개선에 대한 연구)

  • Jeon, Dong-Ju;Lee, Seung-Ryool;Choi, Young-Won;Lee, Hye-Won;Kim, Doo-Jung
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.39 no.3
    • /
    • pp.64-70
    • /
    • 2016
  • The recent development of modern weapon system by SOS (System of System) has required users to have more exact decision making. It is possible to achieve the control of complex weapon system more efficiently and effectively by increasing usability. Accordingly, many studies on graphical display have been conducted for several years in the field of HCI (Human Computer Interaction) and GUI (Graphic User Interface), starting from its design stage. Therefore, this paper focuses on evaluating the system GUI usability and analyzing several important points based on performance model, which is a tool for the evaluation and the improvement of service quality. Performance Model, the main focus of this study, reflects user expectations (which is defined as user importance in this paper). The study consists of four steps. First, 34 checklists are drawn from the existing studies related to GUI usability evaluation by using a heuristic method, and then the checklists are matched with 11 weapon system design factors. Next, the study evaluates the importance of GUI element and the usability of weapon system "A" with the checklists twice respectively. Third, the performance of user importance ($P_i$) and the performance of usability ($P_u$) are calculated by modifying a numerical formula for normalization in this step. Finally, the study compares the approach it takes and the existing usability evaluation method, demonstrating that there is a significant difference between the two methods as a result. In addition, 4 improvement factors are suggested for weapon system "A" as "Shortcut" and "Description of Abbreviation," and so on. Although it is necessary to conduct more studies for higher reliability and validity of the results, this study is meaningful considering it takes a new point of view.

R Based Parallelization of a Climate Suitability Model to Predict Suitable Area of Maize in Korea (국내 옥수수 재배적지 예측을 위한 R 기반의 기후적합도 모델 병렬화)

  • Hyun, Shinwoo;Kim, Kwang Soo
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.19 no.3
    • /
    • pp.164-173
    • /
    • 2017
  • Alternative cropping systems would be one of climate change adaptation options. Suitable areas for a crop could be identified using a climate suitability model. The EcoCrop model has been used to assess climate suitability of crops using monthly climate surfaces, e.g., the digital climate map at high spatial resolution. Still, a high-performance computing approach would be needed for assessment of climate suitability to take into account a complex terrain in Korea, which requires considerably large climate data sets. The objectives of this study were to implement a script for R, which is an open source statistics analysis platform, in order to use the EcoCrop model under a parallel computing environment and to assess climate suitability of maize using digital climate maps at high spatial resolution, e.g., 1 km. The total running time reduced as the number of CPU (Central Processing Unit) core increased although the speedup with increasing number of CPU cores was not linear. For example, the wall clock time for assessing climate suitability index at 1 km spatial resolution reduced by 90% with 16 CPU cores. However, it took about 1.5 time to compute climate suitability index compared with a theoretical time for the given number of CPU. Implementation of climate suitability assessment system based on the MPI (Message Passing Interface) would allow support for the digital climate map at ultra-high spatial resolution, e.g., 30m, which would help site-specific design of cropping system for climate change adaptation.

Effect to Material Strength Recovery of Stepped Patch Repair with Epoxy based Particle Reinforced GFRP Composites under Hygrothermal Environment (에폭시 기지 입자 강화 GFRP를 사용한 계단형 패치 보수법이 고온 고습 환경하에서 재료의 물성 회복에 미치는 영향)

  • Jung, Kyung-Seok;Park, Soo-Jeong;Kim, Yun-Hae
    • Composites Research
    • /
    • v.31 no.3
    • /
    • pp.88-93
    • /
    • 2018
  • In this study, damaged composite laminates were repaired by a stepped patch repair method using halloysite nanotube(HNT) and milled carbon(MC) reinforced composite materials with different amount of the particles. And the mechanical and structural effects of the particles on the interface between the damaged and repair surfaces were analyzed. At this time, after exposing them to a harsh environment of high temperature and humidity for a long time, the recovery rate of the material properties relative to the material forming the damaged plate was compared. As a result, at $70^{\circ}C$ high temperature distilled water, the hygroscopicity of the HNT/GFRP composites was significantly different from that of the MC/GFRP composites. Especially, 0.5, 1 wt. % HNT was added, the moisture absorption rate was the lowest and this was the factor that contributed to the mechanical strength increase. On the other hand, MC showed a high hygroscopic resistance only with a small amount, and the strength was different according to the action direction of the load, and the addition amount was also different.

A Study on the Development of Electrolysis System with Vertically Circulating Mercury Capillary Bundle Electrode and its Characteristics (수직형 순환식 수은 모세관 다발체 전극 전해계의 개발과 그 특성 연구)

  • Kim, Kwang-Wook;Lee, Eil-Hee;Shin, Young-Joon;Yoo, Jae-Hyung;Park, Hyun-Soo
    • Applied Chemistry for Engineering
    • /
    • v.7 no.2
    • /
    • pp.228-236
    • /
    • 1996
  • An electrolysis system with a vertically circulating mercury capillary bundle electrode was developed with a very large electrode area in a minimum space. This system was operated by forcedly feeding mercury and aqueous solution containing metal ion into a fiber bundle packed densely within a small porous glass tube. In order to test the characteristics and stability of the electrolysis system, the reduction voltammograms of uranyl and ferric ions were measured with changes of the mercury flow rate and the aqueous flow rate. The aqueous flow rate had a large effect on the electrochemical reaction of metal ion occurring at the interface between the mercury and the aqueous solution and had to be regulated as an appropriate value to have a good limiting current shape. The limiting current was linearly proportional to the aqueous flow rate, and complete reductions of uranyl and ferric ions were rapidly and continuously accomplished at the potential showing limiting current. With a mercury flow rate high enough to keep a capillary continuum of mercury in the fiber bundle, the mercury flow rate had almost no effect on the electrochemical reaction. This system was confirmed to be effective and stable enough to control rapidly and continuously the oxidation state of metal ions fed into the system under an appropriate aqueous flow rate.

  • PDF

Influence of immediate loading on the removal torque value of mini-screws (교정력의 즉시 부하가 미니스크류의 제거 회전력에 미치는 영향의 평가)

  • Sun, Seung-Bum;Kang, Yoon-Goo;Kim, Seung-Hun;Mo, Sung-Seo;Kook, Yoon-Ah
    • The korean journal of orthodontics
    • /
    • v.37 no.6
    • /
    • pp.400-406
    • /
    • 2007
  • The purpose of this experimental study was to evaluate the effect of immediate orthodontic loading on the stability at the bone-implant interface of titanium miniscrews in a rabbit model. Methods: Forty titanium miniscrews (1.6 mm diameter, 8 mm length) were inserted in the tibiae of 10 rabbits. Twenty test group miniscrews were subjected to continuous orthodontic forces of 200g immediately after implantation for a period of 6 weeks. The remaining 20 control group miniscrews were left unloaded for the same follow-up interval. Removal torque values were recorded using a digital torque gauge. An independent t-test was performed. Results: All the miniscrews were stable, and exhibited no mobility or displacement throughout the experimental period. Histologically, miniscrews were well-integrated into bone. No statistically significant differences in removal torque data were found between the loaded test and the unloaded control groups. Conclusions: These findings suggest that titanium miniscrews can be used as anchoring units for orthodontic tooth movement immediately after insertion.

Performances of Anaerobic Sequencing Batch Reactor for Digestion of Municipal Sludge at the Conditions of Critical Solid-liquid Separation (혐기성 연속 회분식 공정에 의한 도시하수슬러지 소화시 고액분리 특성에 따른 처리효율평가)

  • Hur, Joon-Moo;Park, Jong-An
    • Journal of Environmental Health Sciences
    • /
    • v.28 no.5
    • /
    • pp.77-85
    • /
    • 2002
  • The objective of this study was to evaluate the performances of the ASBR under critical conditions of solid-liquid separation, caused by extremely high solids concentration, for wider application of the ASBR to various wastes. The ASBRs and completely-mixed daily-fed control runs were operated using a municipal mixed sludge at 35$^{\circ}C$ and 55$^{\circ}C$. Conversion of completely-mixed daily-fed reactor to sequencing batch mode and changes in HRT of all ASBRs were easily achieved without adverse effect, regardless of digestion temperature. Solids accumulation was remarkable in the ASBRs, and directly affected by settleable solids concentration of the feed sludge. Noticeable difference in solids-liquid separation was that flotation thickening occurred in the mesophilic ASBRs, while gravity thickening was a predominant solid-liquid separation process in the thermophilic ASBRS. Solids profiles at the end of thickening step dramatically changed at solid-liquid interface, and slight difference in solids concentrations was observed within thickened sludge bed. Organics removals based on subnatant or supernatant after thickening always exceeded 80% in all reactors. Thickened sludge volume and gas production of the ASBRs affected mutually. Gas production increased as thickened sludge accumulated, and continuous gas evolution during thickening could cause thickened sludge to expand or resuspend. Thickened sludge volume exceeding a predetermined withdrawal level resulted in loss of organic solids as well as biomass during withdrawal step, leading to decrease in gas production ind SRT. Such an adverse mutual effect was significant in gravity thickening, while it was not sensitive in flotation thickening. Changes in organic loading had no significant effect on organic removals and gas production after build-up of solids in the ASBRs.

Preparation of polymeric composites for surface contamination measurement in order to characterize nuclear facilities decommissioning (원자력시설 해체 시 특성평가를 위한 표면오염 탐지 이중구조 고분자 복합체의 제조)

  • 한명진;서범경;우주희;이근우
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2004.06a
    • /
    • pp.97-104
    • /
    • 2004
  • Double-layered polysulfone composite films, containing cerium activated yttrium silicate (CAYS) as a flour, were prepared from double casting of two polymeric solutions, and their morphology and physical strength were superior to those of single-layered composites. The prepared polymeric films consist of a dense bottom layer and a CAYS-holding top layer. The former is made of coagulating the polysulfone and methylene chloride binary solution and works as a supporter to improve the composite's physical strength, while the latter holding the inorganic fluor plays a role as an active site to detect the radioactive contamination. The prepared films revealed two distinguished, but tightly attached, double layers, their attachment being identified by morphology of the interface between two layers. As prepared by water immersion coagulation, the films have highly developed macropores, compared with a dense structure in the film prepared by evaporation. In the radionuclide detection test of the CAYS-impregnated composites, the films have reliable detection capacity at a radionuclide spotting test. The double-layered composites with the dense support layer show a better stability in holding the radionuclides spotted on the surface as well as an improvement in physical strength, compared with the single-layer composites having shortcomings such as being too porous or being brittle.

  • PDF

A Change of Shear Bond Strength of Orthodontic Resin Adhesives under Water Immersion (침수후 시간에 따른 교정용 레진접착제의 전단결합강도 변화)

  • Lee, Je-Jun;Kim, Jong-Chul
    • The korean journal of orthodontics
    • /
    • v.28 no.5 s.70
    • /
    • pp.783-789
    • /
    • 1998
  • The purpose of this study was to evaluate the changes of shear bond strengths and failure patterns in orthodontic resin adhesives according to the water immersion time. Metal brackets were bonded to the specimens involving the premolars with chemical-cured($Concise^{\circledR}$) and light-cured($Transbond^{\circledR}$) adhesives. The shear bond strength was measured on universal testing machine and the failure patterns were assessed with the adhesive remnant index(ARI) after storage in distilled water at $37^{\circ}C$ for 1 day, 1 week and 1, 3, and 6 months, respectively. The results were as follows. 1. The shear bond strengths at the 6 month in both Concise and Transbond were significantly higher than those at the 1 day, 1 week and 1 month(p<0.05). There were positive correlations between shear bond strength and water immersion time in both Concise and Transbond(P<0.01). 2. There were no significant differences in shear bond strength between Concise and Transbond. 3. The brackets were failed primarily at the bracket base-adhesive interface and there was no significant difference in the incidence of ARI scores according to the water immersion time.

  • PDF

Microwave Dielectric Properties of La2O3-B2O3-TiO2 Glass-Ceramic and BaNd2Ti5O14Ceramic System for LTCC Application (저온동시소성(LTCC)을 위한 결정화 유리(La2O3-B2O3-TiO2계)와 BaNd2Ti5O14 세라믹을 이용한 마이크로파 유전체 특성)

  • 황성진;김유진;김형순
    • Journal of the Korean Ceramic Society
    • /
    • v.41 no.8
    • /
    • pp.599-604
    • /
    • 2004
  • The LTCCs (Low-Temperature Co-fired Ceramics) are very important for electronic industry to build smaller RF modules and to fulfill the necessity for miniaturization of devices in wireless communication industry. The dielectric materials with sintering temperature $T_{sint}$<90$0^{\circ}C$ are required. In this study, BaO-N $d_2$ $O_3$-Ti $O_2$ (BNT : 20∼40 wt%) for ceramic materials and L $a_2$ $O_3$- $B_2$ $O_3$-Ti $O_2$ (LBT : 80∼60 wt%) for crystallizable glasses were used. The glass/ceramic composites were investigated for sintering behavior, phase evaluation, densities, interface reaction and microwave dielectric properties. It was found that the addition LBT glass frist significantly lowered the sintering temperature to below 90$0^{\circ}C$ and the densification with increasing addition LBT glass frist developed rapidly which was meant to be namely 90% of relative density. The sintered bodies ekhibited applicable dielectric properties, namely 15 for $\varepsilon$$_{r}$,, 10000 GHz for Q* $f_{0}$. The results suggest that the composites have good potential as a new candidate for LTCC materials.

Joint stability of internal conical connection abutments with or without hexagon indexes: an in vitro study (내부연결 원추형 임플란트의 육각구조의 유무에 따른 연결부 안정성: 실험적 연구)

  • Lee, Sang-Woon;Cha, Min-Sang;Lee, Ji-Hye;Cho, Lee-Ra;Park, Chan-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.2
    • /
    • pp.95-103
    • /
    • 2020
  • Purpose: The purpose of this study was to compare the axial displacement of the hexagonal and conical abutment in internal conical connection implant after screw tightening and cyclic loading. Materials and Methods: Internal conical connection implants were divided into two groups (n = 10): group HEX, hexagonal abutment; and group CON, conical 2-piece abutments. The axial displacement and removal torque values were measured after 30 Ncm torque tightening and 250N loading test of 100,000 cycles. The Student t test with 5% significance level was used to evaluate the data. Results: HEX group demonstrated significantly higher axial displacement values after 30 Ncm tightening in comparison to the CON group (P < 0.05). No significant difference was found in axial displacement after cyclic loading (P = 0.052). Removal torque loss before and after the cyclic loading both revealed no significant difference between groups (P = 0.057 and P = 0.138). Removal torque value decreased after cyclic loading in both groups (P < 0.05). Conclusion: Overall, both abutment with or without hexagon index presented similar biomechanical performance except HEX group demonstrated significantly more axial displacement after applying tightening torque.