• 제목/요약/키워드: Interconnected Distribution System

검색결과 125건 처리시간 0.03초

분리된 비선형 시스템의 적응 퍼지 슬라이딩모드 제어 (An Adaptive Fuzzy Sliding-Mode Control for Decoupled Nonlinear Systems)

  • 김도우;양해원;윤지섭
    • 제어로봇시스템학회논문지
    • /
    • 제8권9호
    • /
    • pp.719-727
    • /
    • 2002
  • We proposed a decoupled adaptive fuzzy sliding-mode control scheme for a class of fourth-order nonlinear systems. The system is decoupled into two second-order systems such that each subsystem has a separate control target expressed in terms of sliding surface. For these sliding surfaces, we define main and sub target conditions. and, we made intermediate variables which are interconnected both surface conditions from the sub target sliding surface. Then, Two sets of fuzzy rule bases are utilized to represent the equivalent control input with unknown system functions of the main target sliding surface including intermediate variables. The membership functions of the THEN-part, which is used to construct a suitable equivalent control of sliding-mode control, are changed according to the adaptive law. With such a design scheme, we not only maintain the distribution of membership functions over state space but also reduce the computing time considerably. We apply the decoupled adaptive sliding-mode control to a nonlinear Cart-Pole system and confirms the validity of the proposed approach.

분산전원의 배전계통 연계 평가 시스템의 개발에 관한 연구 (Development of the Interconnection Evaluation System for Dispersed Generations in Distribution Systems)

  • 강민관;박재호;오용택;홍상은;노대석
    • 한국산학기술학회논문지
    • /
    • 제7권1호
    • /
    • pp.12-20
    • /
    • 2006
  • 국가차원의 신 재생에너지 활성화 방안에 따라 풍력발전 등의 대규모 분산전원 단지의 도입이 이루어지고 있으나, 이에 대한 기술적인 평가방안이나 해석 방법이 구체적으로 제시되어 있지 않아, 설치자(시도 및 지자체)와 운용자(한전의 배전지사/지점)들은 많은 혼돈과 어려움을 겪고 있는 실정이다. 따라서 본 논문에서는 태양광, 풍력 등의 분산전원이 배전계통에 도입되는 경우, 계통 연계에 대한 기술적인 적합여부를 종합적으로 평가하는 시스템을 개발하였다. 즉, 분산전원을 제작하거나 시공하는 업체와 일반 운용자나 사용자(분산전원을 잘 모르는 비전문가 포함)들이 손쉽게 접근하여, 분산전원의 연계시의 기술적인 문제점과 적합 여부를 판단하는 기술지원 평가 S/W를 제작하였다. 주요 평가 기능으로서는 분산전원의 계통연계 시에 발생할 수 있는 정상, 비정상(사고), 전력품질에 대한 항목으로서, 누구나 동일한 결과를 얻을 수 있는 표준계통에 근거한 평가 알고리즘에 의하여 연계 적합 여부를 판단하는 것이다.

  • PDF

PSCAD/EMTDC를 이용한 배전계통의 선로전압조정장치와 전지전력저장장치의 모델링에 관한 연구 (A Study on the Modeling of Step Voltage Regulator and Energy Storage System in Distribution System Using the PSCAD/EMTDC)

  • 김병기;김기영;이주광;최성식;노대석
    • 한국산학기술학회논문지
    • /
    • 제16권2호
    • /
    • pp.1355-1363
    • /
    • 2015
  • 태양광전원이 연계된 배전계통에서 발생되는 과전압문제를 해소하기 위하여, 계통에서 발생하는 전압변동에 대응하여 전압을 일정하게 유지시킬 수 있는 선로 전압 조정장치(Step Voltage Regulator)의 도입이 제안되고 있다. 일반적으로 SVR은 전압조정 방법에 의하여 Tap위치를 결정한 후, 일정시간이 지나면 Tap이 동작하도록 운용된다. 하지만 지연시간(30sec) 이후에 Tap을 동작시키는 SVR의 특성에 의하여, 이 시간동안 수용가전압은 규정치를 벗어날 가능성을 가지고 있다. 따라서 본 논문에서는 배전계통의 상용소프트웨어인 PSCAD/EMTDC를 이용하여 LDC방법에 의한 SVR의 전압조정 모델링과, 양방향으로 유무효전력을 제어할 수 있는 전지전력저장장치(Battery Energy Storage System)의 모델링을 제안하였다. 또한 SVR의 문제점을 보완하기 위하여, BESS와의 협조방안에 대한 모델링을 제시하였다. 상기에서 제안한 모델링을 바탕으로 수용가의 전압특성을 분석한 결과, SVR과 BESS에 의하여 안정적으로 전압이 유지됨을 확인하여, 본 연구에서 제시한 모델링의 유효성을 입증하였다.

풍력발전(DFIG)의 고압배전선로의 사고특성 해석에 관한 연구 (A Study on Fault Characteristics of Wind Power in Distribution Feeders)

  • 김소희;김병기;노대석
    • 한국산학기술학회논문지
    • /
    • 제13권3호
    • /
    • pp.1288-1295
    • /
    • 2012
  • 2008년도 지식경제부의 전망에 의하면 신재생에너지전원 중 풍력발전의 보급전망은 2020년 37%, 2030년 42%에 달하고, 2012년부터 시행 예정인 신재생에너지 의무할당제(Renewable Portfolio Standard-RPS)의 도입으로 태양광 및 풍력 등의 신재생에너지가 향후 지속적으로 배전계통에 연계 운용될 것으로 예상된다. 현재 풍력은 배전계통에 전용선로로 연계되어 계통에 미치는 영향은 미미하지만, 3[MW] 이상의 대규모 풍력발전이 일반 배전선로로 확대 운용되면, 풍력발전 연계용 변압기 및 풍력발전기의 %임피던스에 의한 사고전류 변동으로 보호계전기(OCR, OCGR)의 오 부동작을 야기할 수 있다. 따라서 본 논문에서는 대표적인 풍력발전기인 이중여자유도발전기(Double-Fed Induction Generator-DFIG)가 고압 배전선로에 연계되어 운전되는 경우, 3상단락, 2선단락 및 1선지락의 사고특성을 분석하기 위하여, 전력계통 상용소프트웨어인 PSCAD/EMTDC를 이용하여 풍력발전기의 모델링과 시뮬레이션을 수행하고, 대칭좌표법을 통한 이론적인 수치해석의 결과치를 비교/분석하여, 제안한 수법의 유용성을 확인하였다.

PSCAD/EMTDC를 이용한 풍력발전의 배전계통 사고특성에 관한 연구 (A Study on Fault Characteristics of DFIG in Distribution Systems Based on the PSCAD/EMTDC)

  • 손준호;김병기;전진택;노대석
    • 한국융합학회논문지
    • /
    • 제2권2호
    • /
    • pp.47-56
    • /
    • 2011
  • 2008년도 지식경제부의 전망에 의하면 신재생에너지전원 중 풍력발전의 보급전망은 2020년 37%, 2030년 42%에 달하고, 2012년부터 시행 예정인 신재생에너지 의무할당제(Renewable Portfolio Standard-RPS)의 도입으로 태양광 및 풍력 등의 신재생에너지가 향후 지속적으로 배전계통에 연계 운용될 것으로 예상된다. 현재 풍력은 배전계통에 전용선로로 연계되어 계통에 미치는 영향은 미미하지만, 3[MW] 이상의 대규모 풍력발전이 일반 배전선로로 확대 운용되면, 풍력발전 연계용 변압기 및 풍력발전기의 %임피던스에 의한 사고전류 변동으로 보호계전기(OCR, OCGR)의 오 부동작을 야기할 수 있다. 따라서 본 논문에서는 대표적인 풍력발전기인 이중여자유도발전기(Double-Fed Induction Generator-DFIG)가 고압 배전선로에 연계되어 운전되는 경우, 3상단락, 2선단락 및 1선지락의 사고특성을 분석하기 위하여, 전력계통 상용소프트웨어인 PSCAD/EMTDC를 이용하여 풍력발전기의 모델링과 시뮬레이션을 수행하고, 대칭좌표법을 통한 이론적인 수치해석의 결과치를 비교/분석하여, 제안한 수법의 유용성을 확인하였다.

저 전력 시스템 온 칩 설계를 위한 버스 분할 기술 (Bus Splitting Techniques for Low Power SoC Design)

  • 임호영;윤미선;신현철;박성주
    • 한국정보과학회논문지:시스템및이론
    • /
    • 제32권6호
    • /
    • pp.324-332
    • /
    • 2005
  • 일반적으로 버스에서 소모되는 에너지는 전체 시스템에서 큰 비중을 차지한다. 버스 분할 방법은 시스템의 소모 에너지를 줄이고 각 버스 세그먼트들의 기생 부하(parasitic load)를 감소시킴으로서 지연시간을 줄이는데 사용될 수 있다. 버스를 분할함에 있어서 버스에 의해 상호 연결된 처리소자들 사이의 데이타 교환 확률 분포에 따라 가장 적은 에너지를 소모하는 버스 분할 방법은 달라질 수 있다. 본 연구에서는 수평적인 버스 분할 구조의 확장된 개념으로 트리구조 기반의 버스 분할 방법에 대해 연구하고, 이를 바탕으로 여러 가지 버스 분할 방법 중에서 주어진 시스템의 처리소자 간 데이타 교환 확률의 분포에 따라 가장 적합한 구조를 선택하는 문제에 대해 논하였다. 실험 결과는 제안된 방법들이 버스에서 소모되는 에너지를 최대 83$\%$까지 감소시킬 수 있음을 보여준다.

A development of system dynamics model for water, energy, and food nexus (W-E-F nexus)

  • Wicaksono, Albert;Jeong, Gimoon;Kang, Doosun
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2015년도 학술발표회
    • /
    • pp.220-220
    • /
    • 2015
  • Water, energy, and food security already became a risk that threatens people around the world. Increasing of resources demand, rapid urbanization, decreasing of natural resources and climate change are four major problems inducing resources' scarcity. Indeed, water, energy, and food are interconnected each other thus cannot be analyzed separately. That is, for simple example, energy needs water as source for hydropower plant, water needs energy for distribution, and food needs water and energy for production, which is defined as W-E-F nexus. Due to their complicated linkage, it needs a computer model to simulate and analyze the nexus. Development of a computer simulation model using system dynamics approach makes this linkage possible to be visualized and quantified. System dynamics can be defined as an approach to learn the feedback connections of all elements in a complex system, which mean, every element's interaction is simulated simultaneously. Present W-E-F nexus models do not calculate and simulate the element's interaction simultaneously. Existing models only calculate the amount of water and energy resources that needed to provide food, water, or energy without any interaction from the product to resources. The new proposed model tries to cope these lacks by adding the interactions, climate change effect, and government policy to optimize the best options to maintain the resources sustainability. On this first phase of development, the model is developed only to learn and analyze the interaction between elements based on scenario of fulfilling the increasing of resources demand, due to population growth. The model is developed using the Vensim, well-known system dynamics model software. The results are amount of total water, energy, and food demand and production for a certain time period and it is evaluated to determine the sustainability of resources.

  • PDF

분산전원 연계선로에서 지락 고장시 중성선의 과전류 해석 및 대책 (An Analysis and Countermeasure for the Neutral Line of the Overcurrent Phenomena when Ground Faults of distribution system interconnected with distributed Generations)

  • 신동열;정종만;신창훈;김동명
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.500_502
    • /
    • 2009
  • 한전의 분산전원 연계규정에 따르면 수전고객은 변압기 결선이 ${\triangle}-Yg$ 주로 사용되나 분산전원 연계선로는 변압기 결선이 $Yg-{\triangle}$ 형태로 연계되어 있다. 전원계통 고장시 ${\triangle}-Yg$ 결선 방식은 역조류가 발생되지 않으나, $Yg-{\triangle}$ 결선방식은 중성선을 통해 최대 2000[A]까지 역으로 고장전류를 공급한다[1]. 이때 보호계전기 오동작뿐만 아니라 연계용변압기, 케이블 등 설비보호를 위해서는 고장전류의 크기를 반드시 제한해야 된다. 본 논문은 연계용변압기에 의해서 공급되는 중성선의 과전류 현상을 해석하고, 이론적으로 해석된 결과를 PSCAD/EMTDC로 검증하였으며 고장전류의 크기를 저감하기 위해 NGR 저항 값을 조절하면서 고장전류의 크기를 시뮬레이션 하였다. 분산전원 연계선로에서 영상분 고장전류의 크기를 저감하는 방법으로 연계용 변압기($Yg-{\triangle}$) 1차 측에 중성선에 NGR(Neutral Grounding Reactor; 중성점 접지리액터)을 설치해야 하며 영상임피던스를 조절하는 방법을 제시하였다.

  • PDF

UCA와 필드버스를 이용한 전력 설비 자동화 통신망 구축 방안 연구 (A Study on the Implementation of Automation Network for Power Utility using UCA and Fieldbus)

  • 최인호;황인휘;홍승호
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제49권6호
    • /
    • pp.287-298
    • /
    • 2000
  • The UCA is a standard-based approach to utility communications which provides for wide scale integration of functional areas including customer interface, distribution, transmission, power plant, control center, and corporate information systems. Field devices in the power facilities require real-time communications, and they must be interconnected into fieldbus. This study introduces a method of implementing gateway that interfaces UCA and fieldbus. In this study, PROFIBUS and FOUNDATION Fieldbus are selected as candidate fieldbus protocols. Protocol interface in the gateway can be accomplished by mapping objects and services of UCA and fieldbus. MOst of the UCAs CASM objects and services are directly mapped into those of the application and user layers of fieldbus. However, some CASM services are not supported in the application and user layers of fieldbus. This study presents the method of implementing those services. In order to show that the implementation of interface is possible, this study presents pseudo-codes of interface program that maps the objects and services of UCA and fieldbus.

  • PDF

전기품질개선을 위한 효율적인 고조파 진단 툴 개발 (Effective Harmonic Diagnose Tool for Power Quality Problems)

  • 설용태;이의용
    • 한국산학기술학회논문지
    • /
    • 제3권1호
    • /
    • pp.63-68
    • /
    • 2002
  • 본 연구는 산업용 전력계통에서의 전기 품질을 개선하기 위한 고조파 진단 툴의 개발에 대한 것이다. 이 시스템은 계통의 다양한 운전상태에서 시뮬레이션과 계측을 통한 전기품질 분석에 적합하도록 구성하였다. 시뮬레이션은 PTW(Power Tools for Windows)를 이용하였고, 고조파 측정에는 Dranetz사의 PP-4300 장비가 RS-232를 통해 개인용 컴퓨터와 연결되어 시뮬레이션과 실측 데이터를 비교분석 할 수 있게 하였다. 케이블의 영상분 임피던스 등 미진한 입력자료는 수정된 T&D와 BICC를 이용하였고, IEEE표준 데이터가 변압기 입력자료 측정에 적용되었다. 제안된 시스템은 대규모 실제 산업용 수변전 계통에 적용한 결과 고조파 진단의 유연성과 효율성을 입증할수 있었다.

  • PDF