• 제목/요약/키워드: Interconnected Distribution System

검색결과 125건 처리시간 0.036초

대용량 연료전지시스템의 계통외란 방지알고리즘에 관한 연구 (A Study on the Countermeasure Algorithm for Power System Disturbances in Large Scale Fuel Cell Generation System)

  • 최성식;김병기;박재범;노대석
    • 전기학회논문지
    • /
    • 제65권5호
    • /
    • pp.711-717
    • /
    • 2016
  • Recently, fuel cell generation system with high energy efficiency and low CO2 emission is energetically interconnected with distribution power system. Especially, MCFC(molten carbonate fuel cell) operating at high temperature conditions is commercialized and installed as a form of large scale power generation system. However, it is reported that power system disturbances such as harmonic distortion, surge phenomenon, unbalance current, EMI(Electromagnetic Interference), EMC (Electromagnetic Compatibility) and so on, have caused several problems including malfunction of protection device and damage of control devices in the large scale FCGS(Fuel Cell Generation System). Under these circumstances, this paper proposes countermeasure algorithms to prevent power system disturbances based on the modelling of PSCAD/EMTDC and P-SIM software. From the simulation results, it is confirmed that proposed algorithms are useful method for the stable operation of a large scale FCGS.

3kW급 계통연계형 태양광발전시스템의 성능특성 평가분석 (Performance Analysis and Evaluation of 3kW Grid-Connected PV Systems)

  • 소정훈;정영석;유권종;최주엽;최익
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제53권8호
    • /
    • pp.509-516
    • /
    • 2004
  • The concerns of distributed generations including photovoltaic(PV) system have been increased around the world since PV system is becoming widespread as a clean and gentle energy source for earth. In the future high density grid-connected PV systems will be interconnected with distribution network. As a result, the stability and long-term reliability of PV systems have become more important issues in this area. Grid-connected PV systems have been installed and monitored at field demonstration test center(FDTC) and also data acquisition system(DAS) has been constructed for measuring and analyzing performance of PV system to observe the overall effect of environmental conditions on their operation characteristics. The performance of PV system has been evaluated and analyzed for component perspective (PV array and power conditioning system) and global perspective (system efficiency, capacity factor, and electrical power energy) by field test and loss factors of PV system.

분산전원이 연계된 배전계통에 보호협조기기 평가시스템의 최적운용에 관한 연구 (A study on Optimal Operation of Protection Coordination Devices Evaluation System in Distribution System with Distributed Sources)

  • 지성호;송방운;김병기;노대석
    • 한국산학기술학회논문지
    • /
    • 제14권6호
    • /
    • pp.2971-2978
    • /
    • 2013
  • 최근 배전계통은 정부의 녹색성장 정책으로 태양광, 풍력발전 등과 같은 분산전원의 보급률이 지속적으로 증가되고 있는 실정이다. 이러한 분산전원의 연계로 기존 배전계통의 조류흐름은 단방향(One-direction)에서 양방향(Bi-direction)으로 변화되고, 고장전류의 증 감이 발생하는 등, 다양한 변화가 생겨 배전계통의 운용상에 여러 가지 문제점들이 발생할 가능성이 커지고 있다. 따라서 본 논문에서는 분산전원의 배전계통 연계에 따른 보호기기의 정정 및 양방향 보호협조 검토가 가능한 보호협조 평가알고리즘과 실제의 사고전류 값을 이용한 개선된 T-C곡선 알고리즘을 제안하고, 이 알고리즘을 바탕으로 양방향 보호협조 평가시스템을 개선하였다. 또한 평가시스템을 이용하여 배전계통을 모델링하고, 분산전원 연계 시 보호기기들 간의 보호협조를 검토하여, 분산전원이 연계된 경우 배전계통에 발생할 수 있는 기술적인 문제점들을 분석하여 그 방안을 제시하였다.

다중변수 혼돈계를 이용한 이미지 암호화 방법의 설계 및 구현 (Design and Implementation of Image Encryption Method for Multi-Parameter Chaotic System)

  • 임거수
    • 융합보안논문지
    • /
    • 제8권3호
    • /
    • pp.57-64
    • /
    • 2008
  • 컴퓨터성능의 향상과 인터넷의 발달로 인하여 디지털 이미지의 보안에 대한 중요성이 계속 증가 하고 있고, 이런 현상때문에 혼돈신호를 이용한 암호화 알고리즘은 새롭고 효과적인 이미지 암호화 방법중의 하나로 제시되고 있다. 본 논문에서 우리는 기존의 혼돈신호를 이용한 암호화 방법의 혼돈신호가 특정 값에 변중된 분포로 생성되는 현상에 대한 암호화의 문제점을 보이고 우리가 설계한 다중변수 혼돈계를 이용한 암호화 알고리즘은 혼돈신호의 분포가 생성되는 신호의 전체 영역에 일정한 분포로 발생되는 것을 보인다. 우리는 이미지를 암호화하고 복호화한 결과값으로 우리가 제시한 다중변수 혼돈계를 이용한 암호화 방법의 타당성을 제시한다.

  • PDF

DP Formulation of Microgrid Operation with Heat and Electricity Constraints

  • Nguyen, Minh Y;Choi, Nack-Hyun;Yoon, Yong-Tae
    • Journal of Power Electronics
    • /
    • 제9권6호
    • /
    • pp.919-928
    • /
    • 2009
  • Microgrids (MGs) are typically comprised of distributed generators (DGs) including renewable energy sources (RESs), storage devices and controllable loads, which can operate in either interconnected or isolated mode from the main distribution grid. This paper introduces a novel dynamic programming (DP) approach to MG optimization which takes into consideration the coordination of energy supply in terms of heat and electricity. The DP method has been applied successfully to several cases in power system operations. In this paper, a special emphasis is placed on the uncontrollability of RESs, the constraints of DGs, and the application of demand response (DR) programs such as directed load control (DLC), interruptible/curtaillable (I/C) service, and/or demand-side bidding (DSB) in the deregulated market. Finally, in order to illustrate the optimization results, this approach is applied to a couple of examples of MGs in a certain configuration. The results also show the maximum profit that can be achieved.

동북아 연계선로 구성 및 지역별 예비력 증가 효과 (Northeast Asia Interconnection and Regional Reserve Increase Effects)

  • 이상성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.417-419
    • /
    • 2005
  • This paper presents the effects and the regional power distribution of an increase or a decrease of a power reserve by load flow calculations under seasonal load patterns of each country for the future power shortages faced by the metropolitan areas or by the southeastern area of the South Korea in North-East Asia. In these connections, the types of a power transmission for interconnection consist of the 765kV HVAC and the HVDC. In this paper, the various cases of the power system interconnections in Far-East Asia are presented, and the resulting interconnected power systems are simulated by means of a power flow analysis performed with the PSS/E 28 version tool. The power flow map is drawn from data simulated and the comparative study is done. In this future, a power flow analysis will be considered to reflect the effects of seasonal power exchanges And the plan of assumed scenarios will be considered with maximum or minimum power exchanges during summer or winter in North-East Asia countries.

  • PDF

신재생에너지전원이 도입된 배전계통에서의 신뢰도평가에 관한 연구 (Reliability Assessment for Distribution System interconnected with New Energy Sources)

  • 김찬혁;노대석
    • 한국산학기술학회:학술대회논문집
    • /
    • 한국산학기술학회 2007년도 추계학술발표논문집
    • /
    • pp.152-154
    • /
    • 2007
  • 본 논문에서는 기존의 해석적인 수법에서 여러 신뢰도 지표가 주로 수용가의 수와 지형적인 영향만을 고려한 단점을 보완하기 위하여, 어느 특정지역의 수용가가 실제로 정전되는 경우를 상정하여 수용가의 정전비용을 계산하여, 이에 의한 영향을 신뢰도 지표 속에 나타내도록 하였다. 즉, 정전비용에 따른 수용가의 중요도를 고려하기 위하여, 수용가의 정전비용 특성을 이용한 새로운 신뢰도 평가지수를 정의하여, 양적인 면에서 뿐만 아니라 질적인 면에서도 가장 경제적으로 신뢰도를 향상시킬 수 있는 특정 계통이나 지역, 설비 등을 선택할 수 있는 새로운 신뢰도 평가수법을 제안하였다. 또한, 배전계통에 신재생에너지전원(이하 분산형전원)이 도입된 경우를 상정하여 상기의 신뢰도지수를 산정하는 수법을 제안하였으며, 사고구간을 줄이는 리클로우져와 섹셔널라이저의 동작을 포함한 배전계통의 보호협조 시스템도 고려한 신뢰도지수 산정법도 제안하였다.

  • PDF

Design and Implementation of a Secure Smart Home with a Residential Gateway

  • 김상곤;김태곤
    • 인터넷정보학회논문지
    • /
    • 제23권2호
    • /
    • pp.9-17
    • /
    • 2022
  • In this paper, we propose a secure smart home network model and a novel cryptographic protocol called the Smart Home Security Protocol (SHSP). Authentication, key distribution, and encryption functions are properly supported in order to make a smart home secure, and a residential gateway (RG) plays a central role in performing these functions. According to the characteristics of networks and attached devices, we classify smart homes into three different types of sub-networks and these networks are interconnected with one another by the RG. Depending on a sub-network, we use different types of secure schemes to reduce the burden of the process and the delay in devices while it provides proper security functions. The proposed secure smart home model is implemented and verified by using a variety of embedded system environments.

배전선로 절체에 의한 태양광전원의 수용성 향상방안에 관한 연구 (A Study on Enhancement Method of Hosting Capacity for PV System Based on Primary Feeder Reconfiguration)

  • 이명근;이후동;페레이라 마리토;박지현;태동현;노대석
    • 한국산학기술학회논문지
    • /
    • 제20권11호
    • /
    • pp.239-249
    • /
    • 2019
  • 최근, 정부는 신재생에너지전원을 확대하는 정책을 시행하고 있으며, 이에 따라 다수의 대용량 태양광전원이 배전계통에 활발하게 연계되고 있는 실정이다. 하지만, 이러한 태양광전원이 배전계통에 연계되는 경우, 역조류 현상에 의하여 수용가 전압이 규정전압범위를 벗어날 가능성이 있다. 이러한 문제점을 해결하기 위하여, 배전계통에서 태양광전원의 수용성을 향상시키기 위한 연구가 활발히 이루어지고 있다. 따라서, 본 논문에서는 선로절체에 의한 태양광전원의 수용성 향상을 위하여, 배전계통 상용해석 프로그램인 PSCAD/EMTDC를 이용하여, 3분할 3연계로 구성된 배전계통의 모델링을 제시하고, 태양광전원을 최대한 수용할 수 있는 선로절체 평가알고리즘을 제시한다. 또한, 배전선로 절체 구간 및 태양광전원 연계 용량 등의 다양한 운용 시나리오에 기반하여, 변압기 2차측 직하 수용가전압을 규정전압범위 이내로 유지하는 최대 태양광전원 용량을 산정하기 위하여 최적의 선로절체 구간을 산정한다. 제안한 배전계통의 수용성 평가알고리즘과 모델링을 바탕으로 수용가전압 특성을 분석한 결과, 대용량 태양광전원이 연계된 배전선로를 용량의 여유가 남아있는 선로와 절체하여 재구성하게 되면, 더 많은 용량의 태양광전원의 연계가 가능하여, 본 논문의 유용성을 확인하였다.

대용량 태양광전원이 연계된 배전선로에 있어서 보호협조기기의 최적 운용알고리즘 (Optimal Operation Algorithm of Protection Devices in Distribution Systems With PV System)

  • 권순환;이후동;남양현;노대석
    • 한국산학기술학회논문지
    • /
    • 제19권5호
    • /
    • pp.17-26
    • /
    • 2018
  • 최근, 대용량의 태양광전원이 연계된 배전계통은 기존의 단방향과 달리 양방향의 조류가 발생하고, 태양광전원의 연계위치 및 고장위치에 따라 사고전류의 크기와 방향이 변하여, 보호기기간의 협조시간차가 충분히 확보되지 않는 문제점이 발생할 수 있다. 또한, 태양광전원을 고려하지 않은 기존의 보호기기 정정치를 그대로 적용하고 있어 보호기기간의 협조시간차를 확보하기 어려운 상황이 발생하고 있다. 따라서 본 논문에서는 태양광전원이 연계된 선로에서 고려할 수 있는 3가지 Case의 보호기기 정정치 운용모드를 제시하고, 이를 바탕으로 태양광전원의 용량에 따른 최적의 보호협조 시간을 도출할 수 있는 알고리즘을 제안한다. 한편, 이를 바탕으로 보호협조 전용소프트웨어인 Off-DAS를 이용하여, 태양광전원이 연계된 배전계통을 모델링하고, 보호기기(변전소 계전기, 리클로저(Recloser), 고객계전기, 태양광전원 고객계전기)간의 협조시간차 특성을 분석한다. 실 계통을 대상으로 시뮬레이션을 수행한 결과, 본 논문에서 제시한 보호기기의 정정치 운용 모드와 정정치 산정 방식이 태양광 전원이 연계된 배전계통 보호기기간의 협조시간을 안정적으로 확보할 수 있음을 알 수 있었다.