• 제목/요약/키워드: Inter-correlation

검색결과 693건 처리시간 0.029초

DEVELOPING NONINFORMATIVE PRIORS FOR THE FAMILIAL DATA

  • Heo, Jung-Eun;Kim, Yeong-Hwa
    • Journal of the Korean Statistical Society
    • /
    • 제36권1호
    • /
    • pp.77-91
    • /
    • 2007
  • This paper considers development of noninformative priors for the familial data when the families have equal number of offspring. Several noninformative priors including the widely used Jeffreys' prior as well as the different reference priors are derived. Also, a simultaneously-marginally-probability-matching prior is considered and probability matching priors are derived when the parameter of interest is inter- or intra-class correlation coefficient. The simulation study implemented by Gibbs sampler shows that two-group reference prior is slightly edge over the others in terms of coverage probability.

Error Concealment Using Inter-layer Correlation for Scalable Video Coding

  • Park, Chun-Su;Wang, Tae-Shick;Ko, Sung-Jea
    • ETRI Journal
    • /
    • 제29권3호
    • /
    • pp.390-392
    • /
    • 2007
  • In this paper, we propose a new error concealment (EC) method using inter-layer correlation for scalable video coding. In the proposed method, the auxiliary motion vector (MV) and the auxiliary mode number (MN) of intra prediction are interleaved into the bitstream to recover the corrupted frame. In order to reduce the bit rate, the proposed method encodes the difference between the original and the predicted values of the MV and MN instead of the original values. Experimental results show that the proposed EC outperforms the conventional EC by 2.8 dB to 6.7 dB.

  • PDF

Comparison of Protein Internal Motion by Inter-helical Motional Correlations and Hydrogen Bond Ratio

  • Kim, Byoung-Kook;Yoon, Chang-No
    • 한국생물정보학회:학술대회논문집
    • /
    • 한국생물정보시스템생물학회 2005년도 BIOINFO 2005
    • /
    • pp.305-310
    • /
    • 2005
  • Internal motion of the protein has been described in many papers with C$_{\alpha}$ correlation coefficients to find motional correlation and functional characteristics. To describe the secondary structural motion and stability in protein, we have studied molecular dynamics (MD) simulations on FADD Death Domain and FADD Death Effector Domain which have a similar structure but have different functional characteristics. After 10ns MD simulations, the inter-helical motional correlations and the hydrogen bond ratios were compared between the two domains. From these data we could distinctly compare the internal motions of them and could explain the differences in experimental thermodynamic melting behaviors at molecular level.

  • PDF

임의의 다차원 정보의 온라인 전송을 위한 상관기법전파신경망 (Correlation Propagation Neural Networks for processing On-line Interpolation of Multi-dimention Information)

  • 김종만;김원섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.83-87
    • /
    • 2007
  • Correlation Propagation Neural Networks is proposed for On-line interpolation. The proposed neural network technique is the real time computation method through the inter-node diffusion. In the network, a node corresponds to a state in the quantized input space. Each node is composed of a processing unit and fixed weights from its neighbor nodes as well as its input terminal. Information propagates among neighbor nodes laterally and inter-node interpolation is achieved. Through several simulation experiments, real time reconstruction of the nonlinear image information is processed. 1-D CPNN hardware has been implemented with general purpose analog ICs to test the interpolation capability of the proposed neural networks. Experiments with static and dynamic signals have been done upon the CPNN hardware.

  • PDF

New Texture Prediction for Multi-view Video Coding

  • Park, Ji-Ho;Kim, Yong-Hwan;Choi, Byeong-Ho
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2007년도 7th International Meeting on Information Display 제7권2호
    • /
    • pp.1508-1511
    • /
    • 2007
  • This paper introduces a new texture prediction for MVC( Multi-view Video Coding) which is currently being developed as an extension of the ITU-T Recommendation H.264 | ISO/IEC International Standard ISO/IEC 14496-10 AVC (Advanced Video Coding) [1]. The MVC's prcimary target is 3D video compression for 3D display system, thus, key technology compared to 2D video compression is reducing inter-view correlation. It is noticed, however, that the current JMVM [2] does not effectively eliminate inter-view correlation so that there is still a room to improve coding efficiency. The proposed method utilizes similarity of interview residual signal and can provide an additional coding gain. It is claimed that up to 0.2dB PSNR gain with 1.4% bit-rate saving is obtained for three multi-view test sequences.

  • PDF

Fast Inter Mode Decision Algorithm Based on Macroblock Tracking in H.264/AVC Video

  • Kim, Byung-Gyu;Kim, Jong-Ho;Cho, Chang-Sik
    • ETRI Journal
    • /
    • 제29권6호
    • /
    • pp.736-744
    • /
    • 2007
  • We propose a fast macroblock (MB) mode prediction and decision algorithm based on temporal correlation for P-slices in the H.264/AVC video standard. There are eight block types for temporal decorrelation, including SKIP mode based on rate-distortion (RD) optimization. This scheme gives rise to exhaustive computations (search) in the coding procedure. To overcome this problem, a thresholding method for fast inter mode decision using a MB tracking scheme to find the most correlated block and RD cost of the correlated block is suggested for early stop of the inter mode determination. We propose a two-step inter mode candidate selection method using statistical analysis. In the first step, a mode is selected based on the mode information of the co-located MB from the previous frame. Then, an adaptive thresholding scheme is applied using the RD cost of the most correlated MB. Secondly, additional candidate modes are considered to determine the best mode of the initial candidate modes that does not satisfy the designed thresholding rule. Comparative analysis shows that a speed-up factor of up to 70.59% is obtained when compared with the full mode search method with a negligible bit increment and a minimal loss of image quality.

  • PDF

Reliability of Navicular Drop Measurements in Standing and Sitting Positions

  • Park, Ji-Won;Chang, Jong-Sung;Nam, Ki-Seok
    • The Journal of Korean Physical Therapy
    • /
    • 제22권6호
    • /
    • pp.29-33
    • /
    • 2010
  • Purpose: This study was designed to investigate inter-rater and intra-rater reliability of navicular drop measurements by clinicians in sitting and standing positions. Methods: Fourteen subjects with pronated foot were recruited. Two physical therapists randomly assessed the same patients on different occasions but on the same day. Almost all patients were assessed on more than one day. The intra-rater and inter-rater reliability of navicular dropwas estimated by calculation of the intraclass correlation coefficient (ICC). Results: The intra-rater reliability of navicular drop measurements ranged from 0.93 to 0.87, the inter-rater reliability from 0.98 to 0.70 with the patient in standing and sitting positions. These results showed good reliability for calculated variables. Intra-rater and inter-rater reliability of navicular drop in standing position was higher than those of sitting position. Conclusion: Although inter-rater and intra-rater reliability of navicular drop in the sitting position was lower than in the standing position, measurement of navicular drop in the sitting position showed good reliability and was acceptable for patients who could not stand alone without assistance. We recommend that having the patient in the standing position is appropriate in navicular drop measurement.

인접 치주조직과 임플란트간 거리가 임플란트 주변 골흡수에 미치는 영향;임상 및 방사선사진 검사에 의한 후향적 연구 (Influence of the adjacent periodontium and inter-implant distance on bone resorption around non-submerged implants;A retrospective clinical and radiographic study)

  • 장문택
    • Journal of Periodontal and Implant Science
    • /
    • 제34권3호
    • /
    • pp.535-541
    • /
    • 2004
  • The aims of the present study are firstly to investigate the amount of bone loss around non-submerged implants placed in the posterior region and secondly to investigate the relationship between inter-implant and implant-tooth distance and peri-implant bone loss. Thirty-one subjects with 60 implants were selected consecutively from the implant patient pool at the department of Chonbuk National University Hospital. To be included in the study subject, the implant should have been functioned more than 6 months after loading. Inter-implant and implant-tooth distance, distance between implant shoulder and the first bone contact with the implant(DIB) were measured from the scanning image of the radiograph of each implant. The result showed that; 1. inter-implant distance has a statistically significant relationship with DIB in Pearson correlation analysis. 2. the DIB at the implant facing surface of the implant was greater than that of tooth facing surface of the implant. Within limitation of this study, it is suggested to place an implant not too closely to adjacent implants, and the presence of a tooth adjacent to an implant may keep the level of tooth-facing surface of the implant. Further studies with a prospective design are needed to elucidate the relationship between bone changes and various dimensions around implants.

불임 스트레스 척도 개발에 관한 연구 (A Study on the Development of an Infertility Stress Scale)

  • 김선행;박영주;장성옥
    • 대한간호학회지
    • /
    • 제25권1호
    • /
    • pp.141-155
    • /
    • 1995
  • The objective of this study was to develop a scale to measure stress in infertile couples and to test its reliability and validity. Prior to item generation, a basic decision was made to conceptualize stress in infertile couples as including two dimensions and four subdimensions. The dimensions were, intrapersonal stress including cognitive and affective stress, and interpersonal stress including marital and social stress. Initially 95 items were generated from the inter-view data of 31 primary or secondary infertile women and from a literature review. These items were analyzed through the Index of Content Validity(CVI) and 69 items were selected which met 70% or more of the CVI. This preliminary Infertility Stress Scale were analyzed for reliability and construct validity. Item analysis and factor analysis were applied for construct validity. Forty items were selected through item analysis. This procedure was based on the inter-item correlation matrix, a corrected average inter-item correlation coefficient(.30~.70), a corrected item to total correlation coefficient (.03 or more) and information about the alpha estimate if this item was dropped from the scale. The result of the initial factor analysis including varimax rotation produced eight factors. Five items deleted because of factor complexity(indiscriminate factor loadings). The secondary factor analysis including varimax rotation produced seven factors that coincided with the conceptual framework posed for the scale developed. The seven factors were labeled as ‘meaning of children’,‘worthiness’,‘tenacious linking’,‘marital satisfaction’,‘sexual satisfaction’,‘familial adjustment’ and ‘social adjustment’. The alpha coefficient relating to internal consistency was .93 for reliability The results of this study suggest that the measurement derived from the Infertility Stress Scale is useful in assessing the stress of infertile couples.

  • PDF

A Pilot Study on Hip Bone Mineral Densities Estimation from Forearm CBCT images

  • Ko, Hoon;Lee, Chang-Hoon;Jeong, Kwanmoon;Lee, Myeung Su;Nam, Yunyoung;Yoon, Kwon-Ha;Lee, Jinseok
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제11권12호
    • /
    • pp.6054-6068
    • /
    • 2017
  • In this paper, we defined the relative cross-sectional area of forearm cortical bone and investigated its correlation with hip bone mineral density values of total femur, femoral neck, femoral trochanter, femoral inter-trochanter and femoral ward's triangle, respectively. Based on the correlations, we established a linear transformation between the relative cross-sectional area of forearm cortical bone and each hip bone BMD. We obtained forearm images using CBCT and hip bone BMDs using dual-energy X-ray absorptiometry (DXA) for 28 subjects. We also investigated the optimal forearm region to provide the strongest correlation coefficient. We used the optimized forearm region to establish each linear transformation to estimate BMD values for total femur, femoral neck, femoral trochanter, femoral inter-trochanter and femoral ward's triangle from the relative cross-sectional area of forearm cortical bone, respectively. We observed the strong correlations with total femur (r=0.889), femoral neck (r=0.924), femoral trochanter (r=0.821), femoral inter-trochanter (r=0.867) and femoral ward's triangle (r=0.895), respectively. The strongest correlation was observed in the forearm mid-shaft regions. Our results suggest that the hip bone BMD values can be simply estimated from forearm CBCT images in a convenient sitting position without X-ray exposure on a hip including genital organs, and may be useful for screening osteoporosis.