비교 실험을 통한 PM-2.5 질량농도의 측정오차 분석 (Analysis of Measurement Error for PM-2.5 Mass Concentration by Inter-Comparison Study)

  • 정창훈;박진희;황승만
    • 환경영향평가
    • /
    • 제19권4호
    • /
    • pp.431-441
    • /
    • 2010
  • In this study, inter-comparison for PM-2.5 was undertaken. The PM-2.5 mass concentrations using the gravimetric and beta-attenuation methods were compared during the winter in 2007. Two different types of conventional filter-based measurements (Cyclone type and Impactor type) were also collocated and the measurement data was compared with each other. As a result, continuous PM-2.5 data using beta attenuation method show a comparable mass concentration with gravimetric measurement when the inlet of beta-gauge sampler is heated. The results also showed that the cyclone type shows a little high PM-2.5 concentration than Impactor type. In all the sampling cases, the correlations between measurement methods are high. Subsequently, this study suggests that highly correlated relationship between PM-2.5 measurement instruments can be obtained through the inter-comparison results based on filterb-ased gravimetric method and more intensive measurement and theoretical studies are needed in order to clarify the measurement errors for different sampler types.

비교 측정을 통한 PM-10 질량농도의 오차 분석 (Analysis of Measurement Error for PM-10 Mass Concentration by Inter-Comparison Study)

  • 정창훈;조용성;황승만;정용국;유재천;신동석
    • 한국대기환경학회지
    • /
    • 제23권6호
    • /
    • pp.689-698
    • /
    • 2007
  • Particular attention is paid to the validity of PM-10 measurement using beta attenuation method. In this study, the inter-comparison studies were undertaken for PM-10 sampler with different measuring methods. The three beta attenuation monitoring instruments (BAM1020, FH C-14, and DIGS-150) and filter based gravitational method using High Volume Air Sampler were collocated and mass concentrations were compared from August to November, 2006. The results of the investigation show that beta attenuation monitoring instruments are comparable with gravitational method within 10% of measurement error. For specific conditions under high humidity and high concentrations, the inter-comparison results also showed a relatively good agreement and this can be explained as the effect of inlet heating of beta attenuation instrument. Subsequently, this study shows that beta attenuation monitoring instruments can be equivalently used with reasonable validity when compared gravimetric method.

뇌충격 고전압 기준측정시스템의 국제비교시험 (Inter-comparison Test of Lightning Impulse High Voltage Reference Measuring System)

  • 김민규;이정기;최익순;정주영;김익수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 C
    • /
    • pp.2217-2219
    • /
    • 2005
  • In this paper, an inter-comparison test of lightning impulse reference measurement system between Korea and Japan is reported. At present, such a direct comparison test as the activity to sustain the traceability of the measurement system is generally proposed. Due to the inter-comparison test, ascertaining the grade of the measurement uncertainty and maintaining the level of reference system are accomplished.

  • PDF

표준백금저항온도계를 이용한 온도측정능력 상호비교 (Inter-comparison of temperature measurement capability using standard platinum resistance thermometers)

  • 감기술;강주식;이용재;이광복;김용규;박승남
    • 센서학회지
    • /
    • 제18권1호
    • /
    • pp.86-94
    • /
    • 2009
  • Temperature measurement capability was inter-compared using the transfer standard platinum resistance thermometers(SPRT) among four laboratories of KRISS. The transfer SPRTs were primarily calibrated at the triple point of water and Ga melting point, then used at inter-comparison experiment. Temperature difference of calibration value between temperature laboratory and length laboratory at $20^{\circ}C$ was -0.7 mK and +2.4 mK at density laboratory. Temperature measured near $20^{\circ}C$, $25^{\circ}C$ and $30^{\circ}C$ at fluid flow laboratory was deviated by $34.2{\sim}80.4\;mK$ from the calibration values of the transfer SPRT. Ga melting points was inter-compared among three laboratories, and the difference of Ga melting points against the standard Ga melting point of temperature laboratory were $0.03{\sim}0.54\;mK$ at length laboratory and 0.02 mK at density laboratory.

Inter-laboratory Comparison of Stable Carbon and Nitrogen Isotopic Composition Data Using Elemental Analyzer-isotope Ratio Mass Spectrometers

  • Kim, Jung-Hyun;Kang, Sujin;Bong, Yeon-Sik;Park, Kwangkyu;Kang, Tae-Woo;Park, Yong-Se;Kim, Dahae;Choi, Seunghyun;Joo, Young Ji;Choi, Bohyung;Nam, Seung-Il;Lee, Sang-Mo;Shin, Kyung-Hoon
    • 환경분석과 독성보건
    • /
    • 제21권4호
    • /
    • pp.229-236
    • /
    • 2018
  • In this study, inter-laboratory comparison was done using elemental analyzer-isotope ratio mass spectrometers (EA-IRMSs) to determine carbon and nitrogen contents as well as stable carbon and nitrogen isotopic compositions (${\delta}^{13}C$ and ${\delta}^{15}N$) of five environmental samples containing lake and marine sediments, higher plant leaves, and fish muscle, and one organic analytical standard (Protein (Casein) Standard OAS). Five national laboratories participated in this comparison study, and each laboratory analyzed all five samples and the analytical standard. Results showed that variations in total organic carbon (TOC) and total nitrogen (TN) contents as well as ${\delta}^{13}C_{TOC}$ and ${\delta}^{15}N_{TN}$ values among the laboratories were large compared to the analytical uncertainties. The results highlighted the inhomogeneity of the test samples and thus, the need to select suitable standard reference materials for future inter-laboratory studies. Further inter-laboratory comparison exercises could promote good measurement practices in the acquisition of stable carbon and nitrogen isotopic composition data.

Reference dosimetry for inter-laboratory comparison on retrospective dosimetry techniques in realistic field irradiation experiment using 192Ir

  • Choi, Yoomi;Kim, Hyoungtaek;Kim, Min Chae;Yu, Hyungjoon;Lee, Hyunseok;Lee, Jeong Tae;Lee, Hanjin;Kim, Young-su;Kim, Han Sung;Lee, Jungil
    • Nuclear Engineering and Technology
    • /
    • 제54권7호
    • /
    • pp.2599-2605
    • /
    • 2022
  • The Korea Retrospective Dosimetry network (KREDOS) performed an inter-laboratory comparison to confirm the harmonization and reliability of the results of retrospective dosimetry using mobile phone. The mobile phones were exposed to 192Ir while attached to the human phantoms in the field experiment, and the exposure doses read by each laboratory were compared. This paper describes the reference dosimetry performed to present the reference values for inter-comparison and to obtain additional information about the dose distribution. Reference dosimetry included both measurement using LiF:Mg,Cu,Si and calculation via MCNP simulation to allow a comparison of doses obtained with the two different methodologies. When irradiating the phones, LiF elements were attached to the phones and phantoms and irradiated at the same time. The comparison results for the front of the phantoms were in good agreement, with an average relative difference of about 10%, while an average of about 16% relative difference occurred for the back and side of the phantom. The differences were attributed to the different characteristics of the physical and simulated phantoms, such as anatomical structure and constituent materials. Nevertheless, there was about 4% of under-estimation compared to measurements in the overall linear fitting, indicating the calculations were well matched to the measurements.

Development and Evaluation of Tip Pinch Strength Measurement on a Paretic Hand Rehabilitation Device

  • Kim, Jung-Yeon;Cha, Ye-Rin;Lee, Sang-Heon;Jung, Bong-Keun
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제11권2호
    • /
    • pp.1201-1216
    • /
    • 2017
  • In this study, we described the development of a methodology to measure tip-pinch strength on the paretic hand rehabilitation device and aimed to investigate reliability of the device. FSR sensors were embedded on the device, and tip pinch strength was estimated with data collected from the sensors using a developed equation while participants were demonstrating tip pinch. Reliability tests included inter-rater, test-retest, and inter-instrument reliability. B&L Engineering pinch gauge was utilized for the comparison. Thirty-seven healthy students participated in the experiment. Both inter-rater and test-retest reliability were excellent as Intraclass Correlation Coefficients (ICCs) were greater than 0.9 (p<0.01). There were no statistically significant differences in tip-pinch strengths. Inter-instrument reliability analysis confirmed good correlation between the two instruments (r = 0.88, p < 0.01). The findings of this study suggest that the two instruments are not interchangeable. However, the tip-pinch mechanism used in the paretic hand rehabilitation device is reliable that can be used to evaluate tip pinch strength in clinical environment and can provides a parameter that monitors changes in the hand functions.

Characteristics of Polymer Solar Cells Depending on the Thickness of Active Layer

  • Lee, Dong-Gu;Noh, Seung-Uk;Suman, C.K.;Kim, Jun-Young;Lee, Seong-Hoon;Lee, Chang-Hee
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2009년도 9th International Meeting on Information Display
    • /
    • pp.1204-1207
    • /
    • 2009
  • We investigated the device performance of bulk heterojunction solar cells depending on the active layer thickness. For the systematic comparison, the polymer solar cells comprising RR-P3HT:PCBM (1:0.8 (wt%:wt%)) blend films with different thickness were characterized by impedance spectroscopy, and J-V measurement in dark and solar simulated illumination. The device with 120 nm thickness of active layer exhibited maximum power conversion efficiency of 3.5 % under AM 1.5 100mW/$cm^2$ illumination condition.

  • PDF

흡착관과 캐니스터를 이용한 대기 중 휘발성유기화합물 측정방법의 비교 평가 (Comparison of Measurement Methods for Volatile Organic Compounds in Ambient Air Using Adsorbent Tubes and Canisters)

  • 백성옥;서영교;허귀석;전찬곤;이민도;한진석
    • 한국대기환경학회지
    • /
    • 제32권3호
    • /
    • pp.305-319
    • /
    • 2016
  • This study was carried out to evaluate the performance of two sampling methods, i.e., adsorbent tubes and canisters, for the measurement of ambient volatile organic compounds (VOCs). A total of 24 target VOCs were selected from a list of 48 priority hazardous air pollutants (HAPs) in Korea. The two sampling methods were investigated with a wide range of performance criteria such as repeatability, linearity, and lower detection limits. In addition, mean relative errors (MRE) and mean duplicate precisions (MDP) were estimated by inter-lab comparison studies for duplicate field samples. Precisions for the two methods appeared to be well comparable with the performance criteria recommended by USEPA TO-15 and TO-17 for canister and adsorbent methods, respectively. Correlations and variations between the VOCs concentrations determined by the two methods were generally good in most cases. However, MREs and MDPs for individual VOCs appeared to be widely ranged, depending on each VOC. This implies that the two methods have its own advantages and disadvantages in determining a variety of VOCs in ambient air, and neither of which has absolute superiority. Finally, 9 of 24 VOCs were found to be difficult to determine by either methods due to their unstability in a canister, and lack of appropriate standard materials. Thus, it is suggested that development of measurement methods for such unstable VOCs is an urgent task from a viewpoint of HAPs management.

Reliability and Validity of Measurement Using Smart Phone-Based Goniometer on Pelvic Tilting Angle in Standing and Sitting Position

  • Ha, Sung-Min;Jeon, In-Cheol
    • The Journal of Korean Physical Therapy
    • /
    • 제31권1호
    • /
    • pp.35-39
    • /
    • 2019
  • Purpose: The purpose of this study was to assess the intra-rater and inter-rater reliability and validity of pelvic tilting angle measurements using a smart phone-based inclinometer (Clino) compared to a palpation meter (PALM) in the standing and sitting position. This study used an interchangeable method with Clino to measure the pelvic tilting angle in the standing and sitting positions. Methods: Twenty healthy subjects were recruited. Measurements of the pelvic tilting angle in the standing and sitting positions were obtained by two examiners using the Clino and PALM. A resting session was conducted 10 minutes later to assess the intra and inter rater reliability. To assess validity of the measurement using Clino, a PALM was used as the gold standard. The intra-class correlation coefficient (ICC) was used to determine the intra and inter rater reliability of Clino and a PALM. To assess the validity, the Pearson correlation coefficients were used for two measurement techniques to measure the pelvic tilting angle in the standing and sitting positions. The statistical significance was set to ${\alpha}=0.05$. Results: Measurements of the pelvic tilt had high inter-rater reliability in the standing (ICC=0.82) and sitting (ICC=0.88) positions using Clino and intra-rater reliability in the standing (ICC=0.87) and sitting (ICC=0.91) positions using Clino. Measurements of the pelvic tilt had high validity by a comparison of PALM and Clino in the standing (r=0.83) and sitting (r=0.89) positions (p<0.05). Conclusion: The use of Clino can be recommended as a tool to replace the PALM and measure the pelvic tilt angle in the standing and sitting positions while maintaining the clinical reliability and validity.