• 제목/요약/키워드: Intensity operation

검색결과 445건 처리시간 0.031초

Long Term Results of Microsurgical Dorsal Root Entry Zonotomy for Upper Extremity Spasticity

  • Hong, Joo-Chul;Kim, Min-Soo;Chang, Chul-Hoon;Kim, Sang-Woo;Kim, Oh-Lyong;Kim, Seong-Ho
    • Journal of Korean Neurosurgical Society
    • /
    • 제43권4호
    • /
    • pp.182-185
    • /
    • 2008
  • Objective : The purpose of the present study is to assess the long-term results of microsurgical dorsal root entry zonotomy (MDT) for the treatment of medically intractable upper-extremity spasticity. Methods : The records of nine adult patients who underwent MDT by one operating neurosurgeon from March 1999 to June 2004 were retrospectively reviewed by another investigator who had no role in the management of these patients. In all patients, MDT was performed on all roots of the upper limb (from C5 to T1) for spasticity of the upper extremity. The degree of spasticity was measured by the Modified Ashworth Scale (grade 0-4). Severity of the pain level was determined using the Numeric Rating Scale (NRS, score 0-10). Also, patient satisfaction of the post-operative outcome was assessed. Results : Comparing the preoperative and postoperative spasticity using the Modified Ashworth Scale, we observed improvement in all patients, particularly in five of the nine patients (55.6%) who improved by three grades over an average of 66.4 months (range, 40-96). Regarding patient satisfaction, seven patients (77.8%) had affirmative results. None of the patients experienced severe, life-threatening, postoperative complications. We observed a decrease in the intensity of painful spasms to less than three scores as measured by NRS in all four patients with associated pain. Conclusion : This study shows that MDT provides significant, long-term reduction of harmful spasticity and associated pain in the upper limbs.

터널조명 측정을 통한 조도와 휘도기반의 조명 비교 연구 (Comparison Research between Lighting Based on luminance and Illuminance through Measuring Tunnel Lighting)

  • 이미애;한승훈;김연화
    • 조명전기설비학회논문지
    • /
    • 제27권11호
    • /
    • pp.14-19
    • /
    • 2013
  • Tunnel lighting design and operation are both regulated based on luminance in and out of Korea these days. However, domestic tunnel lighting is operated by internal lighting depending on external brightness by using an illuminometer applying the conversion factor on luminance. The purpose of tunnel lighting is to alleviate the visual shock occurring from the rapid change from external brightness to internal brightness when entering a tunnel. However, when looking at the tunnels operated based on an illuminometer, it is not a system where the driver can measure the brightness within his or her viewing angle when entering the tunnel. It is general to install and operate the illuminometer on the roof of an administrative office near the tunnel; however, this method is not structured to connect with the internal lighting by checking the brightness of the viewing scope of the driver, thus is not structured to properly apply the viewing conditions of the driver. Rather, it should be in a method for extracting the luminance value within the viewing scope of the driver pursuant to tunnel lighting standards and in connection with internal lighting. This research seeks to find the difference between operations based on luminance and operations based on intensity of Illuminance in road tunnels through field measuring, and to suggest the necessity of operating based on luminance with the resulting value.

다층 양자우물구조 광 변조기와 전계효과 트랜지스터를 사용한 광 송/수신기회로의 SPICE 모사 (SPICE Simulation of All-Optical Transmitter/Receiver Circuits Configured with MQW Optical Modulators and FETs)

  • 이유종
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 1999년도 춘계종합학술대회
    • /
    • pp.420-424
    • /
    • 1999
  • 전계효과 트랜지스터와 광 다이오우드 및 다층 양자우물구조 광 변조기로 구성되는 광 스위치 회로와 몇 가지 전광 송/수신기 회로(all-optical transmitter/receiver circuits)에 대하여 시변 천이 동작 특성을 SPICE를 사용 모사한 결과를 기술하였다. 본 모사 실험에서 광 변조기 소자의 수광 창의 크기는 20 $\mu\textrm{m}$ $\times$ 20 $\mu\textrm{m}$으로 고려하였고 사용된 FET 소자의 게이트 폭은 100 $\mu\textrm{m}$이며 전달컨덕턴스 값은 측정된 소자 특성에서 55 mS/mm로 사용되었다. 모사 결과 광 논리소자의 고속 동작을 위해서는 소자의 크기를 줄이며 입력 광 다이오우드의 responsivity가 최대값을 가지는 바이어스점에 동작하도록 설계하고, 짧고 강한 세기의 광선을 입력 광 신호로 사용해야 함을 알 수 있었다.

  • PDF

동작 MR 영상에서 비강체 정합과 감산 기법을 이용한 자동 전립선 분할 기법 (Automatic prostate segmentation method on dynamic MR images using non-rigid registration and subtraction method)

  • 이정진;이호;김정곤;이창경;신영길;이윤철;이민선
    • 한국멀티미디어학회논문지
    • /
    • 제14권3호
    • /
    • pp.348-355
    • /
    • 2011
  • 본 논문에서는 동적 자기 공명 영상에서 자동 전립선 분할 기법을 제안한다. 제안 기법은 평균 밝기값 분석을 통하여 동적 MR 영상들 중에서 전립선 영역이 조영증강이 잘 된 영상을 찾는다. 다음으로 조영전 MR 영상과 조영증강된 MR 영상을 B-스플라인 비강체 정합 기법으로 매칭 후 감산하여 전립선 후보 영역을 검출한다. 마지막으로 외부 방향으로 확장 연산을 수행한 후 내부 방향으로 연속적인 형태 전파를 수행하여 전립선 경계를 검출한다. 10명의 환자 데이터에 대하여 제안 기법으로 분할한 결과와 수작업으로 분할한 결과를 비교하여 정확성을 검증하였다. 평균 볼륨 오버랩 오차는 6.8%였고, 평균 절대값 볼륨 측정 오차는 2.5%였다. 제안 기법은 정확한 전립선 분할을 필요로 하는 컴퓨터 보조 전립선 진단 기법에 사용될 수 있다.

전차선 아크 검측 시스템 개발 (Development of Catenary Arc Detection System)

  • 송성근;이택희;조성재;문철이;박성모
    • 한국철도학회논문집
    • /
    • 제13권1호
    • /
    • pp.37-43
    • /
    • 2010
  • 전차선과 팬터그래프는 전기철도차량에 전력을 공급하기 위해 사용된다. 전기철도차량 운행 시 전차선과 팬터그래프 사이의 불안정한 접촉에 의하여 아크가 발생하며 이는 고장 및 사고의 원인이 된다. 따라서 아크를 검출하고 전차선 유지보수를 위한 아크 검측 시스템의 필요성이 요구되고 있다. 본 논문에서는 이러한 전차선 아크 검측 시스템의 개발에 관하여 기술하였다. 아크는 광 검출기를 이용하여 간접 측정하며 가선 전압/전류, 전차선의 높이, 주행속도, 발생위치와 온/습도를 동영상과 함께 저장한다. 개발된 시스템은 서울-동대구간 하행선에서 시험 검측하고 평가하였다. 실험 결과, 아크 발생 및 강도는 가신 전압/전류, 팬터그래프의 높이, 속도에 크게 영향을 받는 것으로 나타났다.

스포츠 영상 내에서 자동적인 가상 광고 삽입을 위한 다층퍼셉트론 기반의 저정보 영역 검출 (Low-Informative Region Detection based on Multi-Layer Perceptron for Automatical Insertion of Virtual Advertisement in Sports Image)

  • 정재영;김종하
    • 디지털콘텐츠학회 논문지
    • /
    • 제18권1호
    • /
    • pp.71-77
    • /
    • 2017
  • 가상광고는 컴퓨터 그래픽을 이용하여 스포츠영상과 같은 미디어제작영상에 제품의 이미지, 로고, 선전문구 등을 삽입하는 광고기법이다. 최근 영상처리 기술과 컴퓨터 성능의 상승으로 인해 스포츠영상에 가상광고를 삽입하기 위한 기술적인 요소가 충족되어 영상 내에 가상광고의 삽입이 활발하게 진행되고 있다. 또한 자동적인 가상광고 삽입을 위한 영상 처리 기술이 가상광고 영역에서 중요한 연구 분야로 자리 잡고 있다. 이에 본 논문에서는 스포츠 영상 내에서 자동적으로 가상광고를 삽입하기 위해 영상처리 기법과 기계학습을 활용하여 저정보 영역을 추출하는 방법을 제안한다. 제안 방법은 영상의 밝기 정도를 히스토그램을 통해 분석하고 기계학습 방법을 활용하여 저정보 영역을 추출한다.

Round robin analysis of vessel failure probabilities for PTS events in Korea

  • Jhung, Myung Jo;Oh, Chang-Sik;Choi, Youngin;Kang, Sung-Sik;Kim, Maan-Won;Kim, Tae-Hyeon;Kim, Jong-Min;Kim, Min Chul;Lee, Bong Sang;Kim, Jong-Min;Kim, Kyuwan
    • Nuclear Engineering and Technology
    • /
    • 제52권8호
    • /
    • pp.1871-1880
    • /
    • 2020
  • Round robin analyses for vessel failure probabilities due to PTS events are proposed for plant-specific analyses of all types of reactors developed in Korea. Four organizations, that are responsible for regulation, operation, research and design of the nuclear power plant in Korea, participated in the round robin analysis. The vessel failure probabilities from the probabilistic fracture mechanics analyses are calculated to assure the structural integrity of the reactor pressure vessel during transients that are expected to initiate PTS events. The failure probabilities due to various parameters are compared with each other. All results are obtained based on several assumptions about material properties, flaw distribution data, and transient data such as pressure, temperature, and heat transfer coefficient. The realistic input data can be used to obtain more realistic failure probabilities. The various results presented in this study will be helpful not only for benchmark calculations, result comparisons, and verification of PFM codes developed but also as a contribution to knowledge management for the future generation.

허쉬슈프렁병 환아의 무신경절 장관에서 Neural Cell Adhesion Molecule (NCAM) 과 Glial Cell Line-Derived Neurotrophic Factor (GDNF)의 발현 (Expression of Neural Cell Adhesion Molecule (NCAM) and Glial Cell Line-Derived Neurotrophic Factor (GDNF) in Aganglionic Bowel of Hirschsprung's Disease)

  • 오정탁;한애리;손석우;최승훈;한석주;황의호;양우익
    • Advances in pediatric surgery
    • /
    • 제7권1호
    • /
    • pp.15-20
    • /
    • 2001
  • The pathophysiology of Hirschsprung's disease (HD) is not fully understood, but recent studies have disclosed that neural cell adhesion molecule (NCAM) and glial cell line-derived neurotrophic factor (GDNF) play important roles in the formation of aganglionic bowel of Hirschsprung's disease. To evaluate the roles of NCAM and GDNF in HD, immunohistochemical analysis was performed using formalin-fixed and paraffin-embedded tissue sections. On the basis of the results, we tried to evaluate them as diagnostic markers. The specimens were obtained from 7 patients with HD who underwent modified Duhamel operation. The diagnosis was based on the clinical findings and the absence of ganglion cells in the nerve plexuses by routine microscopy. NCAM immunoreactivity was found in the nerve plexuses and scattered nerve fibers in the smooth muscle layers of ganglionic segments. In aganglionic segments, the number of NCAM positive nerve fibers in the smooth muscle layers was significantly reduced compared with ganglionic segments. In two cases the nerve plexuses in aganglionic segments, NCAM was negligible. The smooth muscle cells showed diffuse immunoreactivity for GDNF and the staining intensity was not different in the aganglionic and ganglionic segments. However, higher expression of GDNF in the nerve plexus of the ganglionic segments was noted comparing to aganglionic segments. These data suggest that both NCAM and GDNF may play important roles in pathogenesis of Hirschsprung's disease and immunohistochemical staining for NCAM can be used as an ancillary diagnostic tool for HD.

  • PDF

귀 모형을 이용한 치과 핸드피스에 대한 소음 저감 장치의 효과 분석 (Effect of Noise Cancelling Devices on Dental Handpieces Using Ear Model)

  • 모승한;강준구;김익환;최형준;송제선;신유석
    • 대한소아치과학회지
    • /
    • 제47권1호
    • /
    • pp.62-69
    • /
    • 2020
  • 이 연구는 치과 핸드피스의 소음 수준과 소음 저감 장치의 효과를 평가하기 위한 것이다. 귀 모형은 치과용 핸드피스 작동 중에 내이에 전달되는 소음의 수준을 측정할 수 있도록 설계되었다. 소음의 크기는 귀 모형과 휴대용 소음 측정기를 사용하여 다양한 조건에서 측정되었다. 시판되는 4종의 소음 저감 장치를 귀 모형에 적용한 후 같은 조건에서 소음 수준을 측정한 뒤 비교하였다. 치과 핸드피스의 소음 수준은 조건에 따라 약 82.5 - 84.4 dB이었다. 4종의 소음 저감 장치를 적용했을 때 소음은 67.4 - 73.8 dB로 감소했다. 4종의 장치 모두 핸드피스의 소음을 줄이는데 유의한 효과가 있었다. 강도와 노출 시간을 고려할 때, 치과 소음은 치과 의료진에게 청력 손상을 일으킬 수 있다. 직업적 청력 손상 위험을 예방하기 위해 소음 저감 장치 사용을 고려할 수 있다.

구속효과를 고려한 원자로 압력용기 균열선단에서의 응력분포 예측 (Evaluation of the Crack Tip Stress Distribution Considering Constraint Effects in the Reactor Pressure Vessel)

  • 김진수;최재붕;김영진
    • 대한기계학회논문집A
    • /
    • 제25권4호
    • /
    • pp.756-763
    • /
    • 2001
  • In the process of integrity evaluation for nuclear power plant components, a series of fracture mechanics evaluation on surface cracks in reactor pressure vessel(RPV) must be conducted. These fracture mechanics evaluation are based on stress intensity factor, K. However, under pressurized thermal shock(PTS) conditions, the combination of thermal and mechanical stress by steep temperature gradient and internal pressure causes considerably high tensile stress at the inside of RPV wall. Besides, the internal pressure during the normal operation produces high tensile stress at the RPV wall. As a result, cracks on inner surface of RPVs may experience elastic-plastic behavior which can be explained with J-integral. In such a case, however, J-integral may possibly lose its validity due to constraint effect. In this paper, in order to verify the suitability of J-integral, tow dimensional finite element analyses were applied for various surface cracks. A total of 18 crack geometries were analyzed, and $\Omega$ stresses were obtained by comparing resulting HRR stress distribution with corresponding actual stress distributions. In conclusion, HRR stress fields were found to overestimate the actual crack-tip stress field due to constraint effect.