• 제목/요약/키워드: Intensity modulated radiotherapy

검색결과 169건 처리시간 0.03초

Advances and Challenges in Intensity-Modulated Radiotherapy for Nasopharyngeal Carcinoma

  • Qu, Song;Liang, Zhong-Guo;Zhu, Xiao-Dong
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권5호
    • /
    • pp.1687-1692
    • /
    • 2015
  • Nasopharyngeal carcinoma is an endemic disease within specific regions in the world. Radiotherapy is the main treatment. In recent decades, intensity-modulated radiation therapy has undergone a rapid evolution. Compared with two-dimensional radiotherapy and/or three-dimensional conformal radiotherapy, evidence has shown it may improve quality of life and prognosis for patients with nasopharyngeal carcinoma. In addition, helical tomotherapy is an emerging technology of intensity-modulated radiation therapy. Its superiority in dosimetric and clinical outcomes has been demonstrated when compared to traditional intensity-modulated radiation therapy. However, many challenges need to be overcome for intensity-modulated radiation therapy of nasopharyngeal carcinoma in the future. Issues such as the status of concurrent chemotherapy, updating of target delineation, the role of replanning during IMRT, the causes of the main local failure pattern require settlement. The present study reviews traditional intensity-modulated radiation therapy, helical tomotherapy, and new challenges in the management of nasopharyngeal carcinoma.

식도암의 방사선치료에서 부분 각도에 의한 회전 치료를 이용한 조사체적의 감소 (Decrease of Irradiated Volume using Rotational Treatment by Avoidance Sector in Radiation Therapy for Esophageal Cancer)

  • 황철환;김성후;구재흥;손종기
    • 한국방사선학회논문지
    • /
    • 제12권5호
    • /
    • pp.583-592
    • /
    • 2018
  • 세기변조방사선치료와 입체적세기조절회전치료 시 조사체적과 선량 퍼짐 현상을 줄이기 위한 방법으로 조사 각도를 제한하는 부분 각도에 의한 회전치료 기능을 적용하여 표적체적과 주변 정상장기의 선량에 대해 입체조형방사선치료와 비교 분석하였다. 치료계획에 따른 표적체적의 선량분포는 통계적으로 유의한 차이를 확인할 수 없었으며, 폐의 5 Gy(V5) 체적에서 입체조형방사선치료 56.53%, 세기변조방사선치료 52.03%, 입체적세기조절회전치료 47.84%를 나타내어 유의한 차이를 나타내었다(CRT-IMRT p=0.035, CRT-VMAT p<0.001, IMRT-VMAT p<0.001). 10 Gy 체적(V10)에서는 입체조형방사선치료 35.12%, 세기변조방사선치료 34.04%, 입체적세기조절회전치료 33.28%를 보여, 입체조형방사선치료와 세기변조방사선치료(p=0.018), 입체적세기조절회전치료(p=0.035)에서 유의한 차이를 나타내었으나 20 Gy 체적(V20)에서는 유의한 선량 차이를 확인할 수 없었다. 심장의 평균선량과 20 Gy 체적은 치료계획에 따라 유의한 차이를 확인할 수 없었으나, 30, 40 Gy 체적은 입체적세기조절회전치료에서 37.16%, 22.46%를 나타내어 입체조형방사선치료와 비교에서 유의한 차이(p=0.028)를 보였다. 이와 같이 조사체적 감소에 따른 폐의 저 선량 체적(V5, V10)의 감소를 확인할 수 있었으며, 세기변조방사선치료와 입체적세기조절회전치료 시 조사 각도를 일부 제한함으로써 표적체적의 선량분포는 동일하게 유지함과 동시에 조사체적을 줄일 수 있었다. 이로 인해 폐의 선량 퍼짐 현상의 감소로부터 폐의 독성을 낮추는데 기여할 수 있을 것으로 사료된다.

Intensity-modulated radiation therapy: a review with a physics perspective

  • Cho, Byungchul
    • Radiation Oncology Journal
    • /
    • 제36권1호
    • /
    • pp.1-10
    • /
    • 2018
  • Intensity-modulated radiation therapy (IMRT) has been considered the most successful development in radiation oncology since the introduction of computed tomography into treatment planning that enabled three-dimensional conformal radiotherapy in 1980s. More than three decades have passed since the concept of inverse planning was first introduced in 1982, and IMRT has become the most important and common modality in radiation therapy. This review will present developments in inverse IMRT treatment planning and IMRT delivery using multileaf collimators, along with the associated key concepts. Other relevant issues and future perspectives are also presented.

Dosimetric comparison between modulated arc therapy and static intensity modulated radiotherapy in thoracic esophageal cancer: a single institutional experience

  • Choi, Kyu Hye;Kim, Jina;Lee, Sea-Won;Kang, Young-nam;Jang, HongSeok
    • Radiation Oncology Journal
    • /
    • 제36권1호
    • /
    • pp.63-70
    • /
    • 2018
  • Purpose: The objective of this study was to compare dosimetric characteristics of three-dimensional conformal radiotherapy (3D-CRT) and two types of intensity-modulated radiotherapy (IMRT) which are step-and-shoot intensity modulated radiotherapy (s-IMRT) and modulated arc therapy (mARC) for thoracic esophageal cancer and analyze whether IMRT could reduce organ-at-risk (OAR) dose. Materials and Methods: We performed 3D-CRT, s-IMRT, and mARC planning for ten patients with thoracic esophageal cancer. The dose-volume histogram for each plan was extracted and the mean dose and clinically significant parameters were analyzed. Results: Analysis of target coverage showed that the conformity index (CI) and conformation number (CN) in mARC were superior to the other two plans (CI, p = 0.050; CN, p = 0.042). For the comparison of OAR, lung V5 was lowest in s-IMRT, followed by 3D-CRT, and mARC (p = 0.033). s-IMRT and mARC had lower values than 3D-CRT for heart $V_{30}$ (p = 0.039), $V_{40}$ (p = 0.040), and $V_{50}$ (p = 0.032). Conclusion: Effective conservation of the lung and heart in thoracic esophageal cancer could be expected when using s-IMRT. The mARC was lower in lung $V_{10}$, $V_{20}$, and $V_{30}$ than in 3D-CRT, but could not be proven superior in lung $V_5$. In conclusion, low-dose exposure to the lung and heart were expected to be lower in s-IMRT, reducing complications such as radiation pneumonitis or heart-related toxicities.

The Role of Intensity Modulated Radiotherapy in Cancer Treatment

  • Cheung, Kin-Yin
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.6-8
    • /
    • 2002
  • Intensity modulated radiotherapy (IMRT) is an advanced but expensive form of 3-dimensional conformal radiation therapy technique. While the initial clinical data appear to be promising for some treatment sites, the cost effectiveness of the treatment modality has yet to be justified by long-term clinical outcome. This presentation reviews the potential efficacy and limitation of IMRT in respect of the practicality, dosimetry, and resource aspects. It tries to explore and draw conclusions on the strategies for using this sophisticated and expensive treatment technique from AFOMP perspective.

  • PDF

Dosimetric Evaluation of 3-D Conformal and Intensity-modulated Radiotherapy for Breast Cancer after Conservative Surgery

  • Mansouri, Safae;Naim, Asmaa;Glaria, Luis;Marsiglia, Hugo
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권11호
    • /
    • pp.4727-4732
    • /
    • 2014
  • Background: Breast cancers are becoming more frequently diagnosed at early stages with improved long term outcomes. Late normal tissue complications induced by radiotherapy must be avoided with new breast radiotherapy techniques being developed. The aim of the study was to compare dosimetric parameters of planning target volume (PTV) and organs at risk between conformal (CRT) and intensity-modulated radiation therapy (IMRT) after breast-conserving surgery. Materials and Methods: A total of 20 patients with early stage left breast cancer received adjuvant radiotherapy after conservative surgery, 10 by 3D-CRT and 10 by IMRT, with a dose of 50 Gy in 25 sessions. Plans were compared according to dose-volume histogram analyses in terms of PTV homogeneity and conformity indices as well as organs at risk dose and volume parameters. Results: The HI and CI of PTV showed no difference between 3D-CRT and IMRT, V95 gave 9.8% coverage for 3D-CRT versus 99% for IMRT, V107 volumes were recorded 11% and 1.3%, respectively. Tangential beam IMRT increased volume of ipsilateral lung V5 average of 90%, ipsilateral V20 lung volume was 13%, 19% with IMRT and 3D-CRT respectively. Patients treated with IMRT, heart volume encompassed by 60% isodose (30 Gy) reduced by average 42% (4% versus 7% with 3D-CRT), mean heart dose by average 35% (495cGy versus 1400 cGy with 3D-CRT). In IMRT minimal heart dose average is 356 cGy versus 90cGy in 3D-CRT. Conclusions: IMRT reduces irradiated volumes of heart and ipsilateral lung in high-dose areas but increases irradiated volumes in low-dose areas in breast cancer patients treated on the left side.

Neck Node Bolus Technique in the Treatment of Nasopharyngeal Carcinoma with Intensity-modulated Radiotherapy

  • Phua, Chee Ee;Ung, Ngie Min;Tan, Boon Seang;Tan, Ai Lian;Eng, Kae Yann;Ng, Bong Seng
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제13권12호
    • /
    • pp.6133-6137
    • /
    • 2012
  • Purpose: To study the effect of bolus versus no bolus in the coverage of the nodal tumour volume with intensity-modulated radiotherapy (IMRT) for the treatment of nasopharyngeal carcinoma (NPC). Methods and Materials: This retrospective study used data from 5 consecutive patients with NPC who were treated with bolus for large neck nodes using IMRT from November 2011-January 2012 in our institute. All these patients were treated radically with IMRT according to our institution's protocol. Re-planning with IMRT without bolus for these patients with exactly the same target volumes were done for comparison. Comparison of the plans was done by comparing the V70 of PTV70-N, V66.5 of PTV70-N, V65.1 of PTV70-N and the surface dose of the PTV70-N. Results: The mean size of the largest diameter of the enlarged lymph nodes for the 5 patients was 3.9 cm. The mean distance of the GTV-N to the skin surface was 0.6 cm. The mean V70 of PTV70-N for the 5 patients showed an absolute advantage of 10.8% (92.4% vs. 81.6%) for the plan with bolus while the V66.5 of PTV70-N had an advantage of 8.1% (97.0% vs. 88.9%). The mean V65.1 also had an advantage of 7.1% (97.6% vs. 90.5%). The mean surface dose for the PTV70-N was also much higher at 61.1 Gy for the plans with bolus compared to only 23.5 Gy for the plans without bolus. Conclusion: Neck node bolus technique should be strongly considered in the treatment of NPC with enlarged lymph nodes treated with IMRT. It yields a superior dosimetry compared t o non-bolus plans with acceptable skin toxicity.

Comparison of Dose Statistics of Intensity-Modulated Radiation Therapy Plan from Varian Eclipse Treatment Planning System with Novel Python-Based Indigenously Developed Software

  • Sougoumarane Dashnamoorthy;Karthick Rajamanickam;Ebenezar Jeyasingh;Vindhyavasini Prasad Pandey;Kathiresan Nachimuthu;Imtiaz Ahmed;Pitchaikannu Venkatraman
    • 한국의학물리학회지:의학물리
    • /
    • 제33권3호
    • /
    • pp.25-35
    • /
    • 2022
  • Purpose: Planning for radiotherapy relies on implicit estimation of the probability of tumor control and the probability of complications in adjacent normal tissues for a given dose distribution. Methods: The aim of this pilot study was to reconstruct dose-volume histograms (DVHs) from text files generated by the Eclipse treatment planning system developed by Varian Medical Systems and to verify the integrity and accuracy of the dose statistics. Results: We further compared dose statistics for intensity-modulated radiotherapy of the head and neck between the Eclipse software and software developed in-house. The dose statistics data obtained from the Python software were consistent, with deviations from the Eclipse treatment planning system found to be within acceptable limits. Conclusions: The in-house software was able to provide indices of hotness and coldness for treatment planning and store statistical data generated by the software in Oracle databases. We believe the findings of this pilot study may lead to more accurate evaluations in planning for radiotherapy.

Dosimetric comparison of intensity-modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT) in total scalp irradiation: a single institutional experience

  • Ostheimer, Christian;Hubsch, Patrick;Janich, Martin;Gerlach, Reinhard;Vordermark, Dirk
    • Radiation Oncology Journal
    • /
    • 제34권4호
    • /
    • pp.313-321
    • /
    • 2016
  • Purpose: Total scalp irradiation (TSI) is a rare but challenging indication. We previously reported that non-coplanar intensity-modulated radiotherapy (IMRT) was superior to coplanar IMRT in organ-at-risk (OAR) protection and target dose distribution. This consecutive treatment planning study compared IMRT with volumetric-modulated arc therapy (VMAT). Materials and Methods: A retrospective treatment plan databank search was performed and 5 patient cases were randomly selected. Cranial imaging was restored from the initial planning computed tomography (CT) and target volumes and OAR were redelineated. For each patients, three treatment plans were calculated (coplanar/non-coplanar IMRT, VMAT; prescribed dose 50 Gy, single dose 2 Gy). Conformity, homogeneity and dose volume histograms were used for plan. Results: VMAT featured the lowest monitor units and the sharpest dose gradient (1.6 Gy/mm). Planning target volume (PTV) coverage and homogeneity was better in VMAT (coverage, 0.95; homogeneity index [HI], 0.118) compared to IMRT (coverage, 0.94; HI, 0.119) but coplanar IMRT produced the most conformal plans (conformity index [CI], 0.43). Minimum PTV dose range was 66.8%-88.4% in coplanar, 77.5%-88.2% in non-coplanar IMRT and 82.8%-90.3% in VMAT. Mean dose to the brain, brain stem, optic system (maximum dose) and lenses were 18.6, 13.2, 9.1, and 5.2 Gy for VMAT, 21.9, 13.4, 14.5, and 6.3 Gy for non-coplanar and 22.8, 16.5, 11.5, and 5.9 Gy for coplanar IMRT. Maximum optic chiasm dose was 7.7, 8.4, and 11.1 Gy (non-coplanar IMRT, VMAT, and coplanar IMRT). Conclusion: Target coverage, homogeneity and OAR protection, was slightly superior in VMAT plans which also produced the sharpest dose gradient towards healthy tissue.

Sinonasal teratocarcinosarcoma treated with surgery followed by volumetric modulated radiotherapy: a case report with review of literature

  • Tandon, Sarthak;Gairola, Munish;Ahlawat, Parveen;Sharma, Kanika;Barik, Soumitra;Sachdeva, Nishtha;Pasricha, Sunil;Shenoy, Apeksha
    • Radiation Oncology Journal
    • /
    • 제36권4호
    • /
    • pp.341-347
    • /
    • 2018
  • Surgical excision along with use of postoperative radiotherapy forms an integral management of sinonasal teratocarcinosarcoma (SNTCS). However, given the rarity of the tumor, no standardised guidelines, dose, technique and target delineation exist especially in the era of modern radiation delivery techniques. This is a case of 55-year-old male diagnosed as SNTCS treated with radical ethmoidectomy followed by volumetric modulated radiotherapy, showing good local control and acceptable toxicity profile.