• 제목/요약/키워드: Intensity modulated radiation therapy(IMRT)

검색결과 202건 처리시간 0.022초

Status of Domestic and International Recommendations for Protection Design and Evaluation of Medical Linear Accelerator Facilities

  • Choi, Sang Hyoun;Shin, Dong Oh;Shin, Jae-ik;Kwon, Na Hye;Ahn, So Hyun;Kim, Dong Wook
    • 한국의학물리학회지:의학물리
    • /
    • 제32권4호
    • /
    • pp.83-91
    • /
    • 2021
  • Various types of high-precision radiotherapy, such as intensity-modulated radiation therapy (IMRT), tomotherapy (Tomo), and stereotactic body radiation therapy have been available since 1997. After being covered by insurance in 2015, the number of IMRT cases rapidly increased 18-fold from 2011 to 2018 in Korea. IMRT, which uses a high-beam irradiation monitor unit, requires higher shielding conditions than conventional radiation treatments. However, to date, research on the shielding of facilities using IMRT and the current understanding of its status are insufficient, and detailed safety regulation procedures have not been established. This study investigated the recommended criteria for the shielding evaluation of facilities using medical linear accelerators (LINACs), including 1) the current status of safety management regulations and systems in domestic and international facilities using medical LINACs and 2) the current status of the recommended standards for safety management in domestic and international facilities using medical LINACs. It is necessary to develop and introduce a safety management system for facilities using LINACs for clinical applications that is suitable for the domestic medical environment and corresponds to the safety management systems for LINACs used overseas.

International Spine Radiosurgery Consortium Consensus Guidelines에 따른 Spine Stereotactic Radiosurgery에서 IMRT와 VMAT의 비교연구 (Comparison of IMRT and VMAT Techniques in Spine Stereotactic Radiosurgery with International Spine Radiosurgery Consortium Consensus Guidelines)

  • 오세안;강민규;김성규;예지원
    • 한국의학물리학회지:의학물리
    • /
    • 제24권3호
    • /
    • pp.145-153
    • /
    • 2013
  • 정위적 체부 방사선치료(Stereotactic Body Radiation Therapy, SBRT)는 척추 전이암을 치료하는데 있어서 점점 증가하고 있다. 표적 종양의 급격한 선량 변화와 등선량 분포를 얻기 위해서, 세기조절방사선치료(Intensity-modulated radiation therapy, IMRT)와 체적변조회전치료(Volumetric-modulated arc therapy, VMAT)는 척추 방사선수술에 있어서 필수적인 치료기법이다. 이 연구의 목적은 표적 종양을 위한 International Spine Radiosurgery (ISRC) Consortium의 consensus guideline으로 그려진 표적에 있어서 IMRT와 VMAT의 치료기법을 질적으로 비교하고자 한다. 경부, 흉부, 요추 부위에 종양치료를 받은 3명의 환자를 선택 하였다. 표적 종양은 ISRC의 consensus guideline을 바탕으로 정의 하였다. $T_B$는 vertebral body만 포함하였고, $T_{BPT}$는 vertebral body, pedicle, transverse process를 포함하였다. 그리고 $T_{ST}$는 spinous process와 transverse process를 포함하여 그렸다. Maximum spinal cord선량은 $T_B$, $T_{BPT}$, $T_{ST}$에서 각각 12.46 Gy, 12.17 Gy, 11.36 Gy였고, IMRT, RA1, RA2에서 각각 11.81 Gy, 12.19 Gy, 11.99 Gy였다. 평균 감소(90%~50%) 선량 거리 (mm)는 $T_B$, $T_{BPT}$, $T_{ST}$에서 각각 3.5 mm, 3.3 mm, 3.9 mm였고, IMRT, RA1, RA2에서 각각 3.7 mm, 3.7 mm, 3.3 mm였다. 가장 복잡한 $T_{BPT}$의 경우에서 IMRT, RA1, RA2의 conformity index는 각각 0.621, 0.761, 0.817 이었고, rDHI는 0.755, 0.796, 0.824 였다. IMRT와 VMAT 모두 척추 정위적 방사선수술에서 표적 종양에 급격한 선량 변화와 등선량 분포를 전달하였다. 그러나 표적 종양이 vertebral body, pedicle, transverse process를 포함한다면, IMRT 치료기법은 VMAT 치료기법과 비교해서 conformity index 측면에서 불충분하였다. 그럼에도 불구하고, IMRT 치료기법은 RA1, RA2와 비교해서 대부분의 영역에서 maximum spinal cord 선량을 줄이는데 더 효과적이었다.

Intensity-modulated radiation therapy in early stage squamous cell carcinoma of the larynx: treatment trends and outcomes

  • Wegner, Rodney E.;Abel, Stephen;Bergin, John J.;Colonias, Athanasios
    • Radiation Oncology Journal
    • /
    • 제38권1호
    • /
    • pp.11-17
    • /
    • 2020
  • Purpose: Definitive radiotherapy remains a primary treatment option for early stage glottic cancer. Intensity-modulated radiation therapy (IMRT) has emerged as the standard treatment technique for advanced head and neck cancers, whereas three-dimensional conformal radiotherapy (3D-CRT) has remained standard for early glottic cancers. We used the National Cancer Database (NCDB) to identify predictors of IMRT use and effect on outcome in these patients. Materials and Methods: We queried the NCDB from 2004-2015 for squamous cell carcinoma of the glottic larynx staged Tis-T2N0 treated with radiation alone. Logistic regression was used to identify predictors of IMRT. Cox regression was used to identify factors predictive of overall survival. Propensity matching was conducted to account for indication bias. Results: We identified 15,627 patients, of which 11% received IMRT. IMRT use rose from 2% in 2004 to 16% in 2015. Predictors of IMRT include: increased comorbidity, T2 stage, urban location, chemotherapy, treatment at an academic center, and later treatment year. Predictors of improved survival were female gender, higher income, lower stage, no chemotherapy, academic facility, and more remote year. There was no difference in survival between 3D-CRT and IMRT across all stages. Conclusions: The rate of IMRT use for early stage glottic laryngeal cancer has increased over time. There was no difference in outcome in patients receiving IMRT versus 3D-CRT across the cohort.

전유방절제술 환자에서 IMRT와 VMAT을 이용한 방사선치료시 선량 분포의 비교 (The Comparison of Dose Distribution on Radiation Therapy between IMRT and VMAT in Modified Radical Mastectomy Patients)

  • 고혜진;김영재;장성주
    • 한국콘텐츠학회논문지
    • /
    • 제14권8호
    • /
    • pp.225-232
    • /
    • 2014
  • 전유방절제술을 시행하고 방사선치료시 조사야에 흉벽과 IMNs이 포함되어 심장과 동측 폐에 고선량의 방사선이 흡수되어 만성이환율에 영향을 미칠 수 있다. 따라서 본 연구에서는 전유방절제술을 시행한 유방암 환자의 방사선 치료시 IMRT와 VMAT 기법을 이용하여 선량분포양상을 비교하고자 한다. 유방암 진단을 받고 전유방절제술과 방사선 치료를 시행 받은 환자 중 PTV내에 IMNs가 포함되는 10명의 환자를 선택하여 환자의 흉벽조직, SCL, IMNs을 포함하여 각각 IMRT와 VMAT를 이용하여 치료계획을 실시한 후 PTV의 일치성과 심장 및 폐에 입사되는 선량을 서로 비교하고자 하였다. 그 결과 IMRT와 VMAT에서 모두 PTV의 일치성은 동일 양상(p<0.05)을 보였으며, 좌측유방암 환자인 경우 심장의 고선량 영역은 VMAT이 더 적은 체적으로 관찰(p<0.05)되었다. 폐선량의 경우 IMRT 보다 VMAT시 선량이 더 적게 관찰(p<0.05)되었다. IMNs을 포함하여 치료하는 경우 VMAT가 IMRT보다 방사선 치료 효율이 높을 것으로 사료된다.

Planning Aspects of Volumetric Modulated Arc Therapy and Intensity Modulated Radio therapy in Carcinoma Left Breast - A Comparative Study

  • Ekambaram, Varadharajan;Velayudham, Ramasubramanian;Swaminathan, Shiyama;Loganathan, Padmanabhan;Swaminathan, Vijaya
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권4호
    • /
    • pp.1633-1636
    • /
    • 2015
  • Background: The advantages of Rapid Arc plans versus Intensity modulated radiotherapy plans for Carcinoma left breast were analyzed. Materials and Methods: In this study 20 Post mastectomy carcinoma left breast patients were analyzed. Both Intensity modulated Radiotherapy and Rapid Arc plans were generated for these patients. IMRT plans with 7 beams in an arc fashion and VMAT plans with two semi arcs were made to achieve 95% dose coverage to 100% volume. The plans were evaluated using Dose volume Histograms. Results: The mean Conformity and Homogeneity index in VMAT is found to be 1.05 and 0.065 respectively whereas in IMRT it was 1.07 and 0.069. The 20% volume of Heart received a mean dose of 960cGy in VMAT and 1300cGy in IMRT. The mean dose was 1236cGy in VMAT and 1870cGy in IMRT. The ipsilateral Lung received 3395cGy to 5% volume and 1840cGy to 20% volume on an average and the mean dose was 1205cGy in VMAT, while the same were found to be 3525cGy, 2012cGy and 1435cGy respectively in IMRT. The Contralateral Lung received a mean dose of 505cGy in VMAT and 553cGy in IMRT. The mean Monitor units in VMAT were 512MU and 1170MU in IMRT. The NTID in VMAT is $108.8{\times}10^5Gycm^3$ and $110.1{\times}10^5Gycm^3$ in IMRT. Conclusions: The target coverage, homogeneity and Conformity index were better in VMAT plans. The Ipsilateral Lung and heart dose were very less in VMAT plans. The Contralateral Lung dose and the Normal Tissue Integral Dose were also lesser in VMAT plans however the difference is not very appreciable. The MU in VMAT plans is almost 50% that of the IMRT plans which results in the reduction of treatment time. On the whole VMAT proves to be a better modality for treating Ca. Left Breast Patients.

Management for locally advanced cervical cancer: new trends and controversial issues

  • Cho, Oyeon;Chun, Mison
    • Radiation Oncology Journal
    • /
    • 제36권4호
    • /
    • pp.254-264
    • /
    • 2018
  • This article reviewed new trends and controversial issues, including the intensification of chemotherapy and recent brachytherapy (BT) advances, and also reviewed recent consensuses from different societies on the management of locally advanced cervical cancer (LACC). Intensive chemotherapy during and after radiation therapy (RT) was not recommended as a standard treatment due to severe toxicities reported by several studies. The use of positron emission tomography-computed tomography (PET-CT) and magnetic resonance imaging (MRI) for pelvic RT planning has increased the clinical utilization of intensity-modulated radiation therapy (IMRT) for the evaluation of pelvic lymph node metastasis and pelvic bone marrow. Recent RT techniques for LACC patients mainly aim to minimize toxicities by sparing the normal bladder and rectum tissues and shortening the overall treatment time by administering a simultaneous integrated boost for metastatic pelvic lymph node in pelvic IMRT followed by MRI-based image guided adaptive BT.

Long-term results of forward intensity-modulated radiation therapy for patients with early-stage breast cancer

  • Ha, Boram;Suh, Hyun Suk;Lee, Jihae;Lee, Kyung-Ja;Lee, Rena;Moon, Byung In
    • Radiation Oncology Journal
    • /
    • 제31권4호
    • /
    • pp.191-198
    • /
    • 2013
  • Purpose: To observe long-term clinical outcomes for patients with early-stage breast cancer treated with forward intensity-modulated radiation therapy (IMRT), including local control and clinical toxicities. Materials and Methods: We retrospectively analyzed a total of 214 patients with stage I-II breast cancer who were treated with breast conserving surgery followed by adjuvant breast radiation therapy between 2001 and 2008. All patients were treated using forward IMRT. The whole breast was irradiated to a dose of 50 to 50.4 Gy followed by an 8 to 12 Gy electron boost to the surgical bed. Results: The median age was 46 years (range, 21 to 82 years) and the medial follow-up time was 7.3 years (range, 2.4 to 11.7 years). Stage T1 was 139 (65%) and T2 was 75 (35%), respectively. Ipsilateral breast recurrence was observed in 3 patients. The 5- and 10-year local control rates were 99.1% and 97.8%, respectively. The cosmetic outcome was evaluated according to the Harvard scale and 89.4% of patients were scored as excellent or good. Conclusion: The whole breast radiation therapy as an adjuvant treatment using a forward IMRT technique showed excellent long-term local control as well as favorable outcomes of toxicity and cosmesis.

The effect of photon energy on intensity-modulated radiation therapy (IMRT) plans for prostate cancer

  • Sung, Won-Mo;Park, Jong-Min;Choi, Chang-Heon;Ha, Sung-Whan;Ye, Sung-Joon
    • Radiation Oncology Journal
    • /
    • 제30권1호
    • /
    • pp.27-35
    • /
    • 2012
  • Purpose: To evaluate the effect of common three photon energies (6-MV, 10-MV, and 15-MV) on intensity-modulated radiation therapy (IMRT) plans to treat prostate cancer patients. Materials and Methods: Twenty patients with prostate cancer treated locally to 81.0 Gy were retrospectively studied. 6-MV, 10-MV, and 15-MV IMRT plans for each patient were generated using suitable planning objectives, dose constraints, and 8-field setting. The plans were analyzed in terms of dose-volume histogram for the target coverage, dose conformity, organs at risk (OAR) sparing, and normal tissue integral dose. Results: Regardless of the energies chosen at the plans, the target coverage, conformity, and homogeneity of the plans were similar. However, there was a significant dose increase in rectal wall and femoral heads for 6-MV compared to those for 10-MV and 15-MV. The $V_{20Gy}$ of rectal wall with 6-MV, 10-MV, and 15-MV were 95.6%, 88.4%, and 89.4% while the mean dose to femoral heads were 31.7, 25.9, and 26.3 Gy, respectively. Integral doses to the normal tissues in higher energy (10-MV and 15-MV) plans were reduced by about 7%. Overall, integral doses in mid and low dose regions in 6-MV plans were increased by up to 13%. Conclusion: In this study, 10-MV prostate IMRT plans showed better OAR sparing and less integral doses than the 6-MV. The biological and clinical significance of this finding remains to be determined afterward, considering neutron dose contribution.

Adjuvant Radiotherapy after Breast Conserving Treatment for Breast Cancer:A Dosimetric Comparison between Volumetric Modulated Arc Therapy and Intensity Modulated Radiotherapy

  • Liu, Zhe-Ming;Ge, Xiao-Lin;Chen, Jia-Yan;Wang, Pei-Pei;Zhang, Chi;Yang, Xi;Zhu, Hong-Cheng;Liu, Jia;Qin, Qin;Xu, Li-Ping;Lu, Jing;Zhan, Liang-Liang;Cheng, Hong-Yan;Sun, Xin-Chen
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권8호
    • /
    • pp.3257-3265
    • /
    • 2015
  • Background: Radiotherapy is an important treatment of choice for breast cancer patients after breast-conserving surgery, and we compare the feasibility of using dual arc volumetric modulated arc therapy (VMAT2), single arc volumetric modulated arc therapy (VMAT1) and Multi-beam Intensity Modulated Radiotherapy (M-IMRT) on patients after breast-conserving surgery. Materials and Methods: Thirty patients with breast cancer (half right-sided and half left-sided) treated by conservative lumpectomy and requiring whole breast radiotherapy with tumor bed boost were planned with three different radiotherapy techniques: 1) VMAT1; 2) VMAT2; 3) M-IMRT. The distributions for the planning target volume (PTV) and organs at risk (OARs) were compared. Dosimetries for all the techniques were compared. Results: All three techniques satisfied the dose constraint well. VMAT2 showed no obvious difference in the homogeneity index (HI) and conformity index (CI) of the PTV with respect to M-IMRT and VMAT1. VMAT2 clearly improved the treatment efficiency and can also decrease the mean dose and V5Gy of the contralateral lung. The mean dose and maximum dose of the spinal cord and contralateral breast were lower for VMAT2 than the other two techniques. The very low dose distribution (V1Gy) of the contralateral breast also showed great reduction in VMAT2 compared with the other two techniques. For the ipsilateral lung of right-sided breast cancer, the mean dose was decreased significantly in VMAT2 compared with VMAT1 and M-IMRT. The V20Gy and V30Gy of the ipsilateral lung of the left-sided breast cancer for VMAT2 showed obvious reduction compared with the other two techniques. The heart statistics of VMAT2 also decreased considerably compared to VMAT1 and M-IMRT. Conclusions: Compared to the other two techniques, the dual arc volumetric modulated arc therapy technique reduced radiation dose exposure to the organs at risk and maintained a reasonable target dose distribution.

Dosimetric advantages and clinical outcomes of simultaneous integrated boost intensity-modulated radiotherapy for anal squamous cell carcinoma

  • Sakanaka, Katsuyuki;Itasaka, Satoshi;Ishida, Yuichi;Fujii, Kota;Horimatsu, Takahiro;Mizowaki, Takashi;Sakai, Yoshiharu;Hiraoka, Masahiro
    • Radiation Oncology Journal
    • /
    • 제35권4호
    • /
    • pp.368-379
    • /
    • 2017
  • Purpose: The purpose of this study was to explore the dosimetric difference between simultaneous integrated boost intensity-modulated radiotherapy (SIB-IMRT) and three-dimensional conformal radiotherapy (3DCRT), and the clinical outcomes of anal squamous cell carcinoma (ASCC) chemoradiotherapy featuring SIB-IMRT. Materials and Methods: This study included ten patients with ASCC who underwent chemoradiotherapy using SIB-IMRT with 5-fluorouracil and mitomycin C. SIB-IMRT delivered 54 Gy to each primary tumor plus metastatic lymph nodes and 45 Gy to regional lymph nodes, in 30 fractions. Four patients received additional boosts to the primary tumors and metastatic lymph nodes; the median total dose was 54 Gy (range, 54 to 60 Gy). We additionally created 3DCRT plans following the Radiation Therapy Oncology Group 9811 protocol to allow dosimetric comparisons with SIB-IMRT. Locoregional control, overall survival, and toxicity were calculated for the clinical outcome evaluation. Results: Compared to 3DCRT, SIB-IMRT significantly reduced doses to the external genitalia, bladder, and intestine, delivering the doses to target and elective nodal region. At a median follow-up time of 46 months, 3-year locoregional control and overall survival rates were 88.9% and 100%, respectively. Acute toxicities were treated conservatively. All patients completed radiotherapy with brief interruptions (range, 0 to 2 days). No patient experienced ${\geq}grade$ 3 late toxicity during the follow-up period. Conclusion: The dosimetric advantages of SIB-IMRT appeared to reduce the toxicity of chemoradiotherapy for ASCC achieving high locoregional control in the extended period.