• 제목/요약/키워드: Intensity measures

검색결과 393건 처리시간 0.028초

Application of Gamma Ray Densitometry in Powder Metallurgy

  • Schileper, Georg
    • 한국분말야금학회:학술대회논문집
    • /
    • 한국분말야금학회 2002년도 제3회 최신 분말제품 응용기술 Workshop
    • /
    • pp.25-37
    • /
    • 2002
  • The most important industrial application of gamma radiation in characterizing green compacts is the determination of the density. Examples are given where this method is applied in manufacturing technical components in powder metallurgy. The requirements imposed by modern quality management systems and operation by the workforce in industrial production are described. The accuracy of measurement achieved with this method is demonstrated and a comparison is given with other test methods to measure the density. The advantages and limitations of gamma ray densitometry are outlined. The gamma ray densitometer measures the attenuation of gamma radiation penetrating the test parts (Fig. 1). As the capability of compacts to absorb this type of radiation depends on their density, the attenuation of gamma radiation can serve as a measure of the density. The volume of the part being tested is defined by the size of the aperture screeniing out the radiation. It is a channel with the cross section of the aperture whose length is the height of the test part. The intensity of the radiation identified by the detector is the quantity used to determine the material density. Gamma ray densitometry can equally be performed on green compacts as well as on sintered components. Neither special preparation of test parts nor skilled personnel is required to perform the measurement; neither liquids nor other harmful substances are involved. When parts are exhibiting local density variations, which is normally the case in powder compaction, sectional densities can be determined in different parts of the sample without cutting it into pieces. The test is non-destructive, i.e. the parts can still be used after the measurement and do not have to be scrapped. The measurement is controlled by a special PC based software. All results are available for further processing by in-house quality documentation and supervision of measurements. Tool setting for multi-level components can be much improved by using this test method. When a densitometer is installed on the press shop floor, it can be operated by the tool setter himself. Then he can return to the press and immediately implement the corrections. Transfer of sample parts to the lab for density testing can be eliminated and results for the correction of tool settings are more readily available. This helps to reduce the time required for tool setting and clearly improves the productivity of powder presses. The range of materials where this method can be successfully applied covers almost the entire periodic system of the elements. It reaches from the light elements such as graphite via light metals (AI, Mg, Li, Ti) and their alloys, ceramics ($AI_20_3$, SiC, Si_3N_4, $Zr0_2$, ...), magnetic materials (hard and soft ferrites, AlNiCo, Nd-Fe-B, ...), metals including iron and alloy steels, Cu, Ni and Co based alloys to refractory and heavy metals (W, Mo, ...) as well as hardmetals. The gamma radiation required for the measurement is generated by radioactive sources which are produced by nuclear technology. These nuclear materials are safely encapsulated in stainless steel capsules so that no radioactive material can escape from the protective shielding container. The gamma ray densitometer is subject to the strict regulations for the use of radioactive materials. The radiation shield is so effective that there is no elevation of the natural radiation level outside the instrument. Personal dosimetry by the operating personnel is not required. Even in case of malfunction, loss of power and incorrect operation, the escape of gamma radiation from the instrument is positively prevented.

  • PDF

공중화장실 복합악취 및 개선에 관한 연구 (대전광역시 동구) (A Study about Improvement of Multiple Odor of Public Toilet (Dong-gu, Daejeon))

  • 조수준;신재영;오상수;유대영;이성재
    • 대한환경공학회지
    • /
    • 제37권4호
    • /
    • pp.240-245
    • /
    • 2015
  • 본 연구에서는 대전광역시 동구를 중심으로 공중화장실에 대하여 악취강도를 공기희석관능법과 기기분석을 통하여 공중화장실관리 및 악취저감대책 수립에 기초자료로 제공하고자 하였다. 악취희석배수는 소변기실에서 10~669, 대변기실에서는 31~464까지 다양하게 나타났다. 한편 민원이 발생할 수 있는 악취강도 2.5도 이상의 악취가 발생하는 곳은 6개소(33%)로 조사되었다. 수세식 발효식 재래식처리방식의 대변기실과 설치년도에 따라 악취강도는 차이가 있으나, 화장실 면적은 차이가 없다. 악취원인물질 확인을 위한 6개 공중화장실을 대상으로 기기분석결과 NH3 최대농도는 2.04 ppm, 평균농도는 0.67 ppm이며, $H_2S$, $CH_3SH$, $(CH_3)_3N$는 검출되지 않았다. 발효식과 재래식공중화장실에는 비누, 방향제, 쓰레기통이 없었다. 화장지는 수세식 화장실의 50%에만 있었다.

초음파에 의한 전완 국소 온도와 정중 운동 신경전도 속도의 변화 (Alteration of Forearm Local Temperature and Median Nerve Conduction Velocity by Therapeutic Ultrasound in Healthy Adult Subjects)

  • 전차선;김택연
    • 대한정형도수물리치료학회지
    • /
    • 제12권1호
    • /
    • pp.37-43
    • /
    • 2006
  • PURPOSE: Previous studies have documented the lack of ultrasound's non-thermal effects on nerve conduction using frequencies of 1 MHz and 870 kHz. The purpose of this study was to determine the biophysical effects of continuous ultrasound on median local forearm temperature and motor nerve conduction velocities using frequencies of 3.0 MHz. SUBJECTS: Twelve healthy subjects (6 males, 6 females, age $22.30{\pm}2.41$ yrs, weight $61.33{\pm}10.16$ kg, height $167.58{\pm}8.04$ cm) without a history of neurological or musculoskeletal injury to their dominant arm volunteered for this study. METHODS AND MATERIALS: Each subject received a total of five treatments, one each at .0, 0.5, 1.0, 1.5, 2.0 W/$cm^2$ of 3 MHz continuous ultrasound on the anterior surface of the middle area of dominant forearm for 10 minutes. Dependent measures for forearm local temperature and median motor nerve conduction velocity (MNCV) were taken pretreatment and immediately post-treatment. One-way ANOVA were used for each dependent measure. RESULTS: The posttreatment forearm local temperature were differed significantly (p<0.001) between intensities of ultrasound. The posttreatment forearm local temperature of the ultrasound treated with 1.0 w/$cm^2$, 1.5 w/$cm^2$ and 2.0 w/$cm^2$ were significantly higher than 0.5 w/$cm^2$ and 0.0 w/$cm^2$ of ultrasound (p<0.05). The posttreatment median MNCV were differed significantly from the respective pretreatment velocities (p<0.001). The MNCV of the ultrasound treated with 0.0 w/$cm^2$ and 0.5 w/$cm^2$ were significantly (p<0.05) slower than that observed pretreatment, while the three ultrasound intensities produced significantly increased posttreatment MNCV: 1.0 w/$cm^2$ and 1.5 w/$cm^2$ and 2.0 W/$cm^2$. The posttreatment MNCV at 2.0 w/$cm^2$ and 1.5 w/$cm^2$ was significantly faster than that at 0 w/$cm^2$, 0.5 w/$cm^2$ and 1.0 w/$cm^2$ (p<0.05), the MNCV at 1.0 w/$cm^2$ was significantly faster than that associated with 0 w/$cm^2$ and 0.5 w/$cm^2$ of ultrasound (p<0.05). CONCLUSIONS: The decreased median motor forearm local temperature and MNCV of the ultrasound treated with 0.0 w/$cm^2$ and 0.5 w/$cm^2$ were attributed to the cooling effect by ultrasound transmission gel. Local forearm temperature and nerve conduction velocity were directly related to the intensity of ultrasound. Alterations in MNCV from ultrasound on healthy nerves appeared to be related to temperature changes induced by thermal effects of ultrasound.

  • PDF

에너지 소모량에 기초한 탐방로 난이도 표준화 연구 (Standardization of Trail Difficulty based on Energy Consumption)

  • 홍석환;권태호;최송현;김경태;김동필
    • 한국환경생태학회지
    • /
    • 제29권4호
    • /
    • pp.626-635
    • /
    • 2015
  • 최근 숲길 이용자들이 폭발적으로 증가하고 있으며, 이에 따라 각종 안전장치를 위한 비용 또한 급격히 증가하고 있다. 그럼에도 다른 사고와 달리 심장관련 사고는 줄지 않고 있어 숲길에 제공되는 난이도 정보의 개선방안에 대한 연구를 지리산 둘레길을 대상으로 진행하였다. 기존 숲길에 대한 난이도 정보는 숲을 관리하는 특정인에 의한 경험적 난이도 또는 단순히 거리를 바탕으로 한 난이도를 3~5단계로 구분하여 제공하고 있어 탐방객이 실제 느끼는 난이도와는 괴리감이 있었다. 본 연구에서는 실질적인 에너지소모량을 바탕으로 한 난이도 제공 가능성을 분석하였다. 거리와 경사에 따른 산소소모량의 계산은 숲길 각 구간에 대한 절대적 비교뿐만 아니라 상대적 비교가 가능하였으며 특정 구간의 운동강도를 간단히 표현하는데 효과적이었다. 아울러 시 종점의 변화에 따른 운동량 변화를 쉽게 확인할 수 있었다. 구간별, 산행방향별 운동량에 대한 표준화된 사전 정보제공은 심장관련 사고의 사전예방 효과가 있을 것으로 판단된다.

The New X-ray Induced Electron Emission Spectrometer

  • Yu.N.Yuryev;Park, Hyun-Min;Lee, Hwack-Ju;Kim, Ju-Hwnag;Cho, Yang-Ku;K.Yu.Pogrebitsky
    • 한국결정학회:학술대회논문집
    • /
    • 한국결정학회 2002년도 정기총회 및 추계학술연구발표회
    • /
    • pp.5-6
    • /
    • 2002
  • The new spectrometer for X-ray Induced Electron Emission Spectroscopy (XIEES) .has been recently developed in KRISS in collaboration with PTI (Russia). The spectrometer allows to perform research using the XAFS, SXAFS, XANES techniques (D.C.Koningsberger and R.Prins, 1988) as well as the number of techniques from XIEES field(L.A.Bakaleinikov et all, 1992). The experiments may be carried out with registration of transmitted through the sample x-rays (to investigate bulk samples) or/and total electron yield (TEY) from the sample surface that gives the high (down to several atomic mono-layers in soft x-ray region) near surface sensitivity. The combination of these methods together give the possibility to obtain a quantitative information on elemental composition, chemical state, atomic structure for powder samples and solids, including non-crystalline materials (the long range order is not required). The optical design of spectrometer is made according to Johannesson true focusing schematics and presented on the Fig.1. Five stepping motors are used to maintain the focusing condition during the photon energy scan (crystal angle, crystal position along rail, sample goniometer rail angle, sample goniometer position along rail and sample goniometer angle relatively of rail). All movements can be done independently and simultaneously that speeds up the setting of photon energy and allows the using of crystals with different Rowland radil. At present six curved crystals with different d-values and one flat synthetic multilayer are installed on revolver-type monochromator. This arrangement allows the wide range of x-rays from 100 eV up to 25 keV to be obtained. Another 4 stepping motors set exit slit width, sample angle, channeltron position and x-ray detector position. The differential pumping allows to unite vacuum chambers of spectrometer and x-ray generator avoiding the absorption of soft x-rays on Be foil of a window and in atmosphere. Another feature of vacuum system is separation of walls of vacuum chamber (which are deformed by the atmospheric pressure) from optical elements of spectrometer. This warrantees that the optical elements are precisely positioned. The detecting system of the spectrometer consists of two proportional counters, one scintillating detector and one channeltron detector. First proportional counter can be used as I/sub 0/-detector in transmission mode or by measuring the fluorescence from exit slit edge. The last installation can be used to measure the reference data (that is necessary in XANES measurements), in this case the reference sample is installed on slit knife edge. The second proportional counter measures the intensity of x-rays transmitted through the sample. The scintillating detector is used in the same way but on the air for the hard x-rays and for alignment purposes. Total electron yield from the sample is measured by channeltron. The spectrometer is fully controlled by special software that gives the high flexibility and reliability in carrying out of the experiments. Fig.2 and fig.3 present the typical XAFS spectra measured with spectrometer.

  • PDF

개인정보 규제요인과 빅데이터 활용간의 관계에서 가명정보 결합의 매개효과 및 조절효과 (The Mediating Effect and Moderating Effect of Pseudonymized Information Combination in the Relationship Between Regulation Factors of Personal Information and Big Data Utilization)

  • 김상광
    • 정보화정책
    • /
    • 제27권3호
    • /
    • pp.82-111
    • /
    • 2020
  • 최근 빅데이터 활용의 영향요인으로 개인정보 규제요인과 가명정보 결합이 핵심 정책수단으로 등장하고 있다. 본 연구는 개인정보 규제요인과 빅데이터 활용의 관계에서 제3의 변수로서 가명정보 결합의 매개효과 및 조절효과를 실증분석하였다. 분석결과, 첫째, 개인정보 규제요인 중 개인정보 정의, 개인정보 동의, 법령위반 처벌강도 요인이, 그리고 가명정보 결합요인 중 결합 비식별성, 결합 가명정보 표준화, 결합 책임성이 빅데이터의 활용에 정(+)의 유의한 관계를 보였다. 둘째, 가명정보 결합 요인 중 결합 비식별성, 결합 가명정보 표준화, 결합 책임성이 개인정보 규제요인과 빅데이터 활용과의 관계에서 정(+)의 매개효과를 보였다. 셋째, 개인정보 규제요인과 빅데이터 활용과의 관계에서 가명정보 결합기관 유형인 자유형, 중개형, 지정형의 순서에 따라 조절효과가 다를 것이라는 가설은 기각되었다. 이상의 분석결과를 기반으로 개인정보 보호와 빅데이터 활용이 조화를 이루는 '착한규제'의 정책대안을 제시하였다.

쿼드트리 격자기반 모형의 홍수범람해석 적용성 평가 (Applicability Evaluation of Flood Inundation Analysis using Quadtree Grid-based Model)

  • 이대업;안현욱;이기하;정관수
    • 한국수자원학회논문집
    • /
    • 제46권6호
    • /
    • pp.655-666
    • /
    • 2013
  • 최근 이상기후로 인해 홍수 등 자연재해의 강도 및 빈도가 증가하고 있다. 2002년 태풍 루사, 2003년 태풍 매미 등 집중호우에 따른 대규모 홍수로 인해 인명 및 재산피해의 급격한 증가가 나타났으며, 이는 불규칙한 기상변화에 대한 기존의 방재대책과 홍수예측시스템의 한계를 보여주고 있다. 이러한 이상 홍수에 효율적으로 대응하기 위해서는 홍수범람 양상을 정확하게 모의할 수 있는 범람모형을 통해 효과적인 대응방안 마련하는 것이 중요하지만 기존의 홍수범람해석모형은 해석시간의 과다소요 및 해석결과의 정확성 등의 문제가 존재한다. 따라서 본 연구에서는 2002년 8월 집중호우로 인해 붕괴된 낙동강 유역의 백산제를 대상으로 쿼드트리격자를 사용하는 Gerris모형을 이용하여 홍수범람해석을 수행하였으며, 기존의 홍수범람모형 중 비구조격자를 사용하는 FLUMEN모형 및 실제 범람지역과의 비교를 통해 쿼드트리 격자기반 홍수범람모형의 적용성 및 효율성을 판단하였다.

도시환경에서 방사능오염 표면의 중요도 분석 (Contaminated Surfaces in an Urban Environment)

  • 황원태;정효준;김은한;한문희;안민호;김인규
    • Journal of Radiation Protection and Research
    • /
    • 제36권3호
    • /
    • pp.148-153
    • /
    • 2011
  • 국제원자력기구(IAEA)에서 주관하는 국제비교프로그램 EMRAS-2(Environmental Modelling for RAdiation Safety, Phase 2) 내 도시오염평가분과에서 설계한 가상 방사능오염 시나리오에 대해 국내모델 METRO-K를 사용하여 도시환경을 구성하는 오염표면의 선량률에 대한 중요도를 분석하였다. 선량률에 대한 오염표면의 기여는 평가위치와 사건 발생 후 시간에 따라 뚜렷이 다른 차이를 나타냈다. 또한 사건이 발생한 당시 강우의 유무와 강우의 강도에 따라서도 오염표면의 기여는 뚜렷한 차이를 나타냈다. 결과적으로 만일 원자력발전소의 사고나 방사능분산장치의 폭발 등과 같은 불의의 사건이 발생하여 도시지역을 오염시킬 경우 방사능피폭에 따른 인체 위해 뿐 아니라 경제적 사회적 영향을 최소화하기 위해서는 해당 환경을 구성하고 있는 표면의 특성을 고려하여 적절한 대응행위를 선택하는 것이 중요하다는 사실을 알 수 있었다.

얕은 심도 VS주상도를 활용한 VS30 예측 방법론 비교 및 최적 계수 제시 (Comparison of Methods Predicting VS30 from Shallow VS Profiles and Suggestion of Optimized Coefficients)

  • 최인혁;곽동엽
    • 한국지반공학회논문집
    • /
    • 제36권3호
    • /
    • pp.15-23
    • /
    • 2020
  • 지표면에서의 지반운동을 예측하는 지반운동예측모델은 30m까지의 평균전단파속도인 VS30을 부지효과를 나타내는 주요한 변수로 사용한다. VS30은 만약 VS주상도 깊이(z)가 30m 이상이면 주상도로부터 바로 계산할 수 있다. 하지만, 모든 부지에서 z가 30m 까지 있는 것은 아니다. 따라서, z < 30m일 경우 30m까지 연장하는 모델로부터 VS30을 예측할 필요가 있다. 이번 연구에서는 국내 지반 환경에 맞게 z가 30m 미만인 부지에서 VS30을 추정하는 예측 모델에 대한 새로운 계수를 제안하였다. 분석 자료로 기상청과 국토지반정보 통합DB센터에서 획득한 297개의 VS주상도를 활용하였고, 선행연구에서 제안한 식의 계수들을 회귀분석을 통해 새롭게 제시하였다. 분석 결과, z ≥ 15m 일 경우 대수로그 잔차의 표준편차가 약 0.061이내이므로 신뢰성 높은 VS30를 예측하는 것으로 확인하였다. z < 15m 일 경우 σ가 계속 증가하며, z = 5m일 경우 σ = 0.1으로 나타났다. 따라서, 매우 얕은 심도의 VS주상도를 모델에 적용하는 경우 주의를 요하며, 가능하다면 30m깊이까지 지반조사를 실시하여 VS30을 계산하는 것을 추천한다.

주식분할 미시분석과 정보효과 측정 (Micro-Study on Stock Splits and Measuring Information Content Using Intervention Method)

  • 김양렬
    • 재무관리연구
    • /
    • 제7권1호
    • /
    • pp.1-20
    • /
    • 1990
  • 시장 효율성 가설의 검증방법으로 가장 많이 이용되는 방법은, 시장이 새로 들어온 정보를 가격형성에 얼마나 빨리 또 어떻게 반영하는가를 검사하는 것이다. 이경우 시장이 개별 주식의 가격을 결정하는 가격모형이 사전에 가정되어야 하며, 이 때문에 효율성가설의 검증에서는 결국 시장모형과 효율성가설이 동시에 검증될 수 밖에 없다. 기존의 대부분 연구에서는 개별 주식의 수익율이 정규분포를 따른다는 가정으로 부터 유도된 시장모형(market model)이나 자산가격모형(capital asset pricing mel)이 가격결정모형으로 차용되었으며, 위험성 척도베타의 안정성과 가격모형이 설명하지 못한 잔차항의 정규성, 상호독립성의 가정하에 시장의 새로운 정보에 대한 반응을 살펴봄으로써 시장의 효율성을 평가하려고 하였다. 그러나 최근의 많은 연구는 베타가 안정적이지 못하며(nonstationary), 잔차항 또한 시계열적으로 자동상간(autocorrelation)되어 있다고 보고하고 있다. 이러한 점을 감안한 상태로 효율성 가설을 검증하기 위한 시도로, 본 연구에서는 시장모형을 기본으로 한 간섭모형(intervention model)을 사용하여 주식분할정보에 대한 시장의 반응을 일간수익을(daily returns)자료를 바탕으로 조사하였다. 본 연구에서도 베타의 불안정성, 잔차의 자동상관이 관찰되었으며, 특히 주석분할을 발표하는 싯점에서 베타는 눈에 띄게 증가하였다. 주식분할정보를 시장이 충분히 빨리 반영하지 못한다는 기존의 연구결과는 본 연구에서 사용된 방법으로도 바뀌지 않으나, 발표후 2주간의 초과수익은 전통적 방법으로 조사한 결과보다 43퍼센트 정도 감소하였다. Lakonishok과 Lev(1987)는 초과수익의 존재를 가격수정동기(price correction motive)로 설명하나, 가격수정동기 자체가 초과수익의 존재를 설명한다기 보다는 주식분할에 다른 위험수준(베타)의 변동이 초과수익의 원인이라 보는 것이 타당하다. 분할이 발표된 주식을 소유하고 있던 기존의 주주들의 입장에서 볼때 자신의 포트폴리오 위험이 자신의 의사와 달리 증가되었으므로 이에 상응한 보상을 원할 것이며, 이 보상이 우리가 관측한 초과수익이라는 설명이 가능하고, 이러한 설명은 주식분할이 발표된 후의 베타가전에 비하여 증가한다는 점으로 뒷받침된다. 본 연구에서 사용된 모형은 기존의 연구에서 반영하지 못한 베타의 불안정성, 잔차의 자동상관성 문제를 해소시켜줄 뿐 아니라, 시장이 접하는 각 종의 정보에 대하여 시장의 차별적 효율성을 조사하는 데에도 적용될 수 있다는 점에서 재미있다. 즉 본문의 모형에서 매개변수 델타(s)는 시장이 새로운 정보를 간격결정에 반영하는 속도를 측정하는 척도이고, 오베가(v)는 시장에 들어온 정보의 강도(strength)의 척도로 볼 수 있다.

  • PDF