• Title/Summary/Keyword: Intensity Function

Search Result 1,500, Processing Time 0.029 seconds

Radioaerosol Inhalation Lung Scan in Pulmonary Emphysema (폐기종의 연무흡입 폐환기스캔 소견)

  • Jeon, Jeong-Su;Park, Young-Ha;Chung, Soo-Kyo;Bahk, Yong-Whee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.24 no.2
    • /
    • pp.229-236
    • /
    • 1990
  • Perfusion and ventilaion imagings of the lung are well established procedure for diagnosing pulmonary embolism, differentiation it from chronic obstructive lung disease, and making an early detection of chronic obstructive lung disease. To evaluate the usefulness of radioaerosol inhalation imaging (RII) in chronic obstructive lung disease, especially pulmonary emphysema, we analyzed RIIs of five normal adult non-smokers, five asymptomatic smokers (age 25-42 years with the mean 36), and 21 patients with pulmonry emphysema (age 59-78 years with the mean 67). Scintigrams were obtained with radioaerosol produced by a BARC nebulizer with 15 mCi of Tc-99m-phytate. Scanning was performed in the anterior, posterior, and lateral projections after five to 10-minute inhalation of the radioaerosol on sitting position. The scans were analyzed and correlated with the results of pulmonary function studies and chest radiographs. Also lung perfusion scan with $^{99m}Tc-MAA$ was performed in 12 patients. In five patients, we performed follow-up scans for the evaluation of the effects of a bronchodilator. Based on the X-ray findings and clinical symptoms, pulmonary emphysema was classified into four types: centrilobular (3 patients), panlobular (4 patients), intermediate (10 patients), and combined (4 patients). RII findings were patternized according to the type, extent, and intensity of the aerosol deposition in the central bronchial and bronchopulmonary system and lung parenchyma. 10 controls, normal five non-smokers and three asymptomatic smokers revealed homogeneous parenchymal deposition in the entire lung fields without central bronchial deposition. The remaining two of asymptomatic smokers revealed mild central airway deposition. The great majority of the patients showed either central (9/21) or combined type (10/21) of bronchopulmonary deposition and the remaining two patients peripheral bronchopulmonary deposition. Parenchymal aerosol deposition in pulmonary emphysema was diffuse (6/21), discrete(6/21), intermediate (3/21), or combined (6/21). In 12 patients studied also with perfusion scans, perfusion defects matched closely with ventilation defects in location and configuration. But the size of the ventilation defects was generally larger than the perfusion defects. In all four patients treated with bronchodilators, the follow-up study demonstrated decrease in abnormal of radioaerosol deposition in the central airway with improvement of ventilation defects. RII was useful technique for the evaluation of regional ventilatory abnormality and the effects of treatment with bronchodilators in pulmonary emphysema.

  • PDF

New Trend of Pain Evaluation by Brain Imaging Devices (뇌기능 영상장치를 이용한 통증의 평가)

  • Lee Sung-Jin;Bai Sun-Joon
    • Science of Emotion and Sensibility
    • /
    • v.8 no.4
    • /
    • pp.365-374
    • /
    • 2005
  • Pain has at least two dimensions such as somatosensory qualities and affect and patients are frequently asked to score the intensity of their pain on a numerical pain rating scale. However, the use of a undimensional scale is questionable in view of the belief, overwhelmingly supported by clinical experience as well as by empirical evidence from multidimensional scaling and other sources, that pain has multidimensions such as sensory-discrimitive, motivational-affective and cognitive-evaluative The study of pain has recently received much attention, especially in understanding its neurophysiology by using new brain imaging techniques, such as positron emission tomography(PET) and functional magnetic resonance imaging (fMRI), both of which allow us to visualize brain function in vivo. Also the new brainimaging devices allow us to evaluate the patients pain status and plan To treat patients objectively. Base4 on our findings we presented what are the new brain imaging devices and the results of study by using brain imaging devices.

  • PDF

Efficacy and Safety of Miniscalpel Acupuncture on Knee Osteoarthritis - A randomized controlled pilot trial -

  • Jun, Seungah;Lee, Jung Hee;Gong, Han Mi;Choi, Seong Hun;Bo, Min Hwang;Kang, Mi Suk;Lee, Geon-Mok;Lee, Hyun-Jong;Kim, Jae Soo
    • Journal of Pharmacopuncture
    • /
    • v.21 no.3
    • /
    • pp.151-158
    • /
    • 2018
  • Objectives: We investigated the efficacy and safety of miniscalpel acupuncture (MA) for knee osteoarthritis (KOA) in an assessor-blinded randomized controlled pilot trial; this would provide information for a large-scale randomized controlled trial. Methods: Participants (n = 24) were recruited and randomly allocated to the MA group (experimental) or acupuncture group (control). The MA group received treatment once a week for 3 weeks (total of 3 treatments), while the acupuncture group received treatment two times per week for 3 weeks (total of 6 treatments). The primary outcome was pain as assessed by a visual analogue scale (VAS). The secondary outcomes (intensity of current pain, stiffness, and physical function) were assessed using the short-form McGill Pain Questionnaire (SF-MPQ) and Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC). Assessments were performed at baseline, 1, 2, and 3 during treatment and at week 5 (2 weeks after the end of treatment). Results: Of the 24 participants, 23 completed the study. Both groups showed significant improvements in VAS, SF-MPQ, and WOMAC. However, there were no significant differences between the MA and acupuncture groups. No serious adverse event occurred and blood test results were within normal limits. Conclusion: Our results suggest that although both MA and acupuncture provide similar effects with regard to pain control in patients with KOA, MA may be more effective in providing pain relief because the same relief was obtained with fewer treatments. A large-scale clinical study is warranted to further clarify these findings.

Studies on the Effects $CCl_4$ on Exorine Pancreas (취외분비선에 미치는 사염화탄소의 영향)

  • Pae, Young-Sook
    • The Korean Journal of Pharmacology
    • /
    • v.11 no.1 s.17
    • /
    • pp.47-53
    • /
    • 1975
  • The metabolism of many drugs and also of steroid hormones is mediated by enzymes located in the microsomal fraction in smooth surfaced endoplasmic reticulum of mammalian liver. The duration and intensity of action of many drugs are largely determined by the speed at which they are metabolized in the body. Repeated administration of phenobarbital results in the induction of enzymes that metabolize a number of drugs. Lee et al. reported that daily administration of phenobarbital in rats significantly increased the activities of amylase in the pancreatobiliary juice, but the concentration of cholate in the bile was significantly lower in the treated group than that in the control group. After animals were treated with $CCl_4$, histological changes were shown in the endoplasmic reticulum, decreased microsomal enzyme activity and decreased hepatic protein synthesis were apparent. The purpose of the present report was to study the interaction between a 'microsomal-stimulating' agent such as phenobarbital and a 'microsomal- depressing' agent such as $CCl_4$ on hepatic and pancreatic functions in rats. The results obtained are summarized as follows: 1. The mortality rate of $CCl_4$ treated group was 34% and was decreased this figure to 15% with phenobarbital pretreatment. 2. In animals treated with phenobarbital the volume of biliary-pancreatic secretion was markedly elevated but the volume was decreased significantly in animals treated with $CCl_4$. 3. Total bilirubin output was elevated markedly in the $CCl_4$ treated group of rats pretreated with phenobarbital. The bilirubin concentration was increased in $CCl_4$ treated group and decreased in the group treated phenobarbital alone. 4. The concentration and total output of cholate in the bile were significantly lower in the all experimental group than control group. 5. In the animals treated with phenobarbital alone and phenobarbital plus $CCl_4$, the activity of lipase in pancreatobiliary juice was elevated, while in the animals treated with $CCl_4$ alone no change was observed. 6. The activity of amylase in the pancreatobiliary juice was decreased in the $CCl_4$ treated group, but elevated markedly in phenobarbital group and also elevated in phenobarbital-$CCl_4$ group. By the above results, it is concluded, when the liver was damaged by $CCl_4$, the exocrine function of pancreas and liver was decreased simultaneously. However, in the animals pretreated with phenobarbital, the toxicity of $CCl_4$ on the liver and pancreas was reduced.

  • PDF

Color Image Rendering using A Modified Image Formation Model (변형된 영상 생성 모델을 이용한 칼라 영상 보정)

  • Choi, Ho-Hyoung;Yun, Byoung-Ju
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.48 no.1
    • /
    • pp.71-79
    • /
    • 2011
  • The objective of the imaging pipeline is to transform the original scene into a display image that appear similar, Generally, gamma adjustment or histogram-based method is modified to improve the contrast and detail. However, this is insufficient as the intensity and the chromaticity of illumination vary with geometric position. Thus, MSR (Multi-Scale Retinex) has been proposed. the MSR is based on a channel-independent logarithm, and it is dependent on the scale of the Gaussian filter, which varies according to input image. Therefore, after correcting the color, image quality degradations, such as halo, graying-out, and dominated color, may occur. Accordingly, this paper presents a novel color correction method using a modified image formation model in which the image is divided into three components such as global illumination, local illumination, and reflectance. The global illumination is obtained through Gaussian filtering of the original image, and the local illumination is estimated by using JND-based adaptive filter. Thereafter, the reflectance is estimated by dividing the original image by the estimated global and the local illumination to remove the influence of the illumination effects. The output image is obtained based on sRGB color representation. The experiment results show that the proposed method yields better performance of color correction over the conventional methods.

A Simple Scoring Method to Calculate the Homogeneity and Coverage Indices of Dose Volume Histogram (DVH를 이용한 선량 균등률 및 덮임률 지수에 관한 연구)

  • Yoon Myong-Geun;Park Sung-Yong;Shin Dong-Ho;Park Jung-Hun;Lee Se-Byeong;Kim Dae-Yong;Kim Joo-Young;Cho Kwan-Ho
    • Progress in Medical Physics
    • /
    • v.17 no.1
    • /
    • pp.6-16
    • /
    • 2006
  • The goal of this study was to develop new indices for effectively evaluating the dose coverage and homogeneity based on the target-volume dose-volume histogram (TV-DVH) of intensity-modulated radio-therapy treatment plans. A new coverage Index and a new homogeneity index were developed by integrating a modified TV-DVH and by fitting a TV-DVH with a modified step function, respectively. The coverage index, named the l-index, indicates whether the dose coverage for the target volume is adequate based on user-defined criteria. A lower l-index indicates higher dose coverage of the tumor volume. The index for assessing dose homogeneity in a target volume, named the n-index, is more accurate than the conventional method in evaluating the dose homogeneity in a tumor volume. The baseline treatment plan for a target volume coverage and homogeneity is discussed. The proposed simple indices have been demonstrated to be effective in evaluating the dose coverage and homogeneity for TV-DVHs.

  • PDF

In Vivo Dosimetry with MOSFET Detector during Radiotherapy (방사선 치료 중 MOSFET 검출기를 이용한 체표면 선량측정법)

  • Kim Won-Taek;Ki Yong-Gan;Kwon Soo-Il;Lim Sang-Wook;Huh Hyun-Do;Lee Suk;Kwon Byung-Hyun;Kim Dong-Won;Cho Sam-Ju
    • Progress in Medical Physics
    • /
    • v.17 no.1
    • /
    • pp.17-23
    • /
    • 2006
  • In Vivo dosimetry is a method to evaluate the radiotherapy; it is used to find the dosimetric and mechanical errors of radiotherapy unit. In this study, on-line In Vivo dosimetry was enabled by measuring the skin dose with MOSFET detectors attached to patient's skin during treatment. MOSFET dosimeters were found to be reproducible and independent on beam directions. MOSFET detectors were positioned on patient's skin underneath of the dose build-up material which was used to minimize dosimetric error. Delivered dose calculated by the plan verification function embedded in the radiotherapy treatment planning system (RTPs), was compared with measured data point by point. The dependency of MOSFET detector used in this study for energy and dose rate agrees with the specification provided by manufacturer within 2% error. Comparing the measured and the calculated point doses of each patient, discrepancy was within 5%. It was enabled to verify the IMRT by using MOSFET detector. However, skin dosimetry using conventional ion chamber and diode detector is limited to the simple radiotherapy.

  • PDF

A Study of the Junior Nursing College Students실 Role during Clinical Practice (간호전문대학생들의 임상실습현장에서의 수행에 관한 연구 -실습의 내용 빈도를 중심으로-)

  • 권경남
    • Journal of Korean Academy of Nursing
    • /
    • v.13 no.3
    • /
    • pp.1-33
    • /
    • 1983
  • The role and function of nursing care nowadays, tend to acquire sophisicated technology because specialization has expended due to increase of the medical population and the improvement of national health standards. To implement nursing care independently as a professional nurse, the apprehension of specific knowledge and skill should be acquired during basic nursing education. So it is important for nursing education not only to include theory and actual techniques, but also to strengthen the practical training in the actual clinical setting. This study was carried out with the following objectives; 1. To survey the detailed content and frequency of actual nursing students display during their clinical training. 2. To investigate the detailed content and frequency of actual nursing behavior which students display in each clinical a area. 3. To identify the motive for selection of nursing as their major and to determine the degree of self confidence, extent of knowledge and recognition of nursing responsibility. 4. To observe the relationship between actual nursing behavior and each of the following; 1) Motive for selecting nursing as a major 2) Self confidence 3) Knowledge of nursing care 4) Recognition of nursing responsibility The conclusions of this study were as follows; 1. Among the detailed nursing behavior which junior nursing college students carry out in clinical training; taking respiration's showed the highest frequency, and taking body temperatures, blood pressures, and pulses and making beds were next in frequency in this order. 2. In detailed nursing behaviors according to clinical area; taking vital signs showed the highest frequency in the emergency room, pediatric ward, orthopedic ward, general surgical ward and internal medicine ward. However, in the operating room, assisting with endotracheal tube insertion and sterile techniques were showen to have the highest frequencies. In nursery, umbilical cord care and the measurement of body weight were the highest in frequency In neurosurgical ward, the measurement of vital signs, changing position and tracheostomy care were the highest in frequency. In obstetric and gynecological ward and in the delivery room, checking duration, intensity and frequency of contractions was the highest in frequency. 3. In regard to the motive for majoring in nursing, the aptitude and interest of the student had the highest percentage(32.86%), and self-confidence in nursing activities (M=3.36), knowledge in nursing activities.(M=3. 09), and the recognition of the nursing activity (M= 3.76) wire in the middle range. 4. When the detailed nursing behaviors were compared with motive, self confidence, knowledge and recognition, it was found that when the nursing behavior was difficult and regarding much endeavor although the motive was high, the frequency of the nursing behavior was rather low. But in the cases in which there was much self confidence and a high level of skill was required, nursing behavior was carried more frequently. When there was muck self confidence and skill was not required, the frequency of nursing behavior was rather low. In the cases of a high level of knowledge, the frequency of nursing behavior was low and when recognition for nursing behavior was given the frequency of nursing behavior was low.

  • PDF

Contaminated Surfaces in an Urban Environment (도시환경에서 방사능오염 표면의 중요도 분석)

  • Hwang, Won-Tae;Jeong, Hyo-Joon;Kim, Eun-Han;Han, Moon-Hee;Ahn, Min-Ho;Kim, In-Kyu
    • Journal of Radiation Protection and Research
    • /
    • v.36 no.3
    • /
    • pp.148-153
    • /
    • 2011
  • EMRAS-2 (Environmental Modelling for RAdiation Safety, Phase 2) is an international comparison program, which is organized by the International Atomic Energy Agency (IAEA), in order to harmonize the modelling of radionuclide behavior in the environment. To do so, the urban contamination working group within EMRAS-2 has designed the hypothetical scenarios for a specified urban area. In this study, the importance of contaminated surfaces composing an urban environment was analyzed in terms of dose rate using METRO-K, which has been developed to take a Korean urban environment into account. The contribution of contaminated surfaces to exposure dose rate showed distinctly a great difference as a function of specified locations and time following a hypothetical event. Moreover, it showed a distinct difference according to the existence of precipitation, and its intensity. Therefore, if an urban area is contaminated radioactively by any unexpected incidents such as an accident of nuclear power plants or an explosion of radioactive dispersion devices (RDDs), appropriate measures should be taken with consideration of the type of surface composing the contaminated environment in order to minimize not only radiation-induced health detriment but also economic and social impacts.

Study of Optical Properties of InxGa1-xN/GaN Multi-Quantum-Well (InxGa1-xN/GaN 다중양자우물 구조의 광학적 성질 연구)

  • Kim, Ki-Hong;Kim, In-Su;Park, Hun-Bo;Bae, In-Ho;Yu, jae-In;Jang, Yoon-Seok
    • Journal of the Korean Vacuum Society
    • /
    • v.18 no.1
    • /
    • pp.37-43
    • /
    • 2009
  • Temperature and injection current dependence of electroluminescence(EL) spectral intensity of the $In_xGa_{1-x}N$/GaN multi-quantum wells(MQW) have been studied over a wide temperature range and as a function of injection current level. It is found that a temperature-dependent variation pattern of the EL efficiency under very low and high injection currents shows a drastic difference. This unique EL efficiency variation pattern with temperature and current can be explained field effects due to the driving forward bias in presence of internal(piezo and spontaneous polarization) fields. Increase of the indium content in $In_xGa_{1-x}N$/GaN multiple quantum wells gives rise to a redshift of 80 meV and 22 meV for green and blue MQW, respectively. It can be explained by carrier localization by potential fluctuation of multiple quantum well and MQW structures also shows a keen difference owing to the different indium content in InGaN/GaN MQW.