• Title/Summary/Keyword: Intensity Analysis

Search Result 5,117, Processing Time 0.031 seconds

Variance characteristics of speaking fundamental frequency and vocal intensity depending on utterance conditions (발화조건에 따른 기본주파수 및 음성강도 변동의 특징)

  • Lee, Moo-Kyung
    • Phonetics and Speech Sciences
    • /
    • v.4 no.1
    • /
    • pp.111-118
    • /
    • 2012
  • The purpose of this study was to characterize and determine variances of speaking fundamental frequency and vocal intensity depending on gender and three utterance conditions (spontaneous speech, reading, and counting). A total of 65 undergraduate students (32 male students, 33 female students) attending universities in Daegu, South Korea participated in this study. The subjects were all in their 20s. This study used KayPENTAX's Visi-Pitch IV (Model 3950) to measure the variances of speaking fundamental frequency (SFF0) and vocal intensity (VI). As a result, this study came to the following conclusions. First, it was found that both males and females showed no significant difference in SFF0 and vocal intensity among three utterance conditions. Second, this study sought to analyze differences in the variances of SFF0 between males and females. As a result, it was found that females showed significantly higher levels of four measured variances (SFF0 $SD^{**}$, SFF0 $range^{***}$, Min $SFF0^{***}$ and Max $SFF0^{***}$) than males on spontaneous speech. However, it was found that there was no significant difference between males and females in SFF0 range on reading or in SFF0 SD and SFF0 range on counting. It was found that there was no significant difference between males and females in the level of measured variances of vocal intensity depending on utterance conditions. Finally, this study made a comparison and analysis on differences in the variances of SFF0 and vocal intensity among utterance conditions. As a result, it was found that all the measured variances of SFF0 in males were most significantly reduced depending upon spontaneous speech which was followed by reading and counting respectively (SFF0 SD: p<.001, SFF0 range: p<.05, Max SFF0: p<.05). Females however, show no significant difference in the measured variances of SFF0 depending upon three utterance conditions. It was also found that the measured variances of vocal intensity in females were most significantly reduced depending on spontaneous speech that was followed by reading and counting (VI SD: p<.001, VI range: p<.001, Min VI: p<.01 Max VI: p<.05), while males showed no significant difference in the measured variances of vocal intensity depending on three utterance conditions. In sum, these findings suggest that variances of SFF0 in males are affected by three utterance conditions, while variances of vocal intensity in females are affected by three utterance conditions.

Analysis of Spectral Light Intensity of High Pressure Sodium and Metal Halide Lamps for Plant Growth (식물생장용 고압나트륨램프와 메탈할라이드램프의 분광 광강도 분석)

  • Lee, Hye-In;Kim, Yong-Hyeon;Kim, Dong-Eok
    • Journal of Biosystems Engineering
    • /
    • v.35 no.6
    • /
    • pp.413-419
    • /
    • 2010
  • Plant growth was greatly affected by the spectral distribution and light intensity of artificial lighting sources. In this study, the spectral characteristics of high power sodium (HPS) lamps and metal halide (MH) lamps produced by three different manufacturers were measured. Even though the spectral distribution of HPS lamps with lamp wattage of 250 W and 400 W was very similar, but the spectral light intensity by the manufacturers was different. Difference in the spectral light intensity of MH lamps by the manufacturers was increased with the increasing lamps wattage. Light intensity at the region of blue (B), green (G), red (R) and far-red (FR) light of HPS and MH lamps was also analyzed. HPS lamps showed the light intensity in order of R, FR, B and G light. The ratio of G, B, R and FR to photosynthetic photon flux (PPF) of HPS lamps with the lamp wattage of 250 W was 3.0-3.2%, 5.5-5.9%, 17.3-19.2% and 6.5-7.8%, respectively. For MH lamps, it showed the light intensity in order of R, FR, B, and G. The ratio of B, G, R, and FR to PPF of MH lamps with 250 W was 14.0-15.5%, 22.6-27.5%, 7.5-9.5% and 2.7-4.2%, respectively. HPS and MH lamps with 400 W had a relatively smaller ratio of R and FR to PPF than those with 250 W. HPS lamps showed that the ratio of light intensity of B and FR to R was 0.15-0.28 and 0.36-0.4, respectively. For MH lamps, the ratio of light intensity of B and FR to R was 1.26-2.72 and 0.27-0.56, respectively. From these results, it was concluded that the portion of blue light of MH lamps was higher than those of HPS lamps.

Evaluation of the Urban Heat Island Intensity in Seoul Predicted from KMA Local Analysis and Prediction System (기상청 국지기상예측시스템을 이용한 서울의 도시열섬강도 예측 평가)

  • Byon, Jae-Young;Hong, Seon-Ok;Park, Young-San;Kim, Yeon-Hee
    • Journal of the Korean earth science society
    • /
    • v.42 no.2
    • /
    • pp.135-148
    • /
    • 2021
  • The purpose of this study was to evaluate the urban heat island (UHI) intensity and the corresponding surface temperature forecast obtained using the local data assimilation and prediction system (LDAPS) of the Korea Meteorological Administration (KMA) against the AWS observation. The observed UHI intensity in Seoul increases during spring and winter, while it decreases during summer. It is found that the diurnal variability of the UHI intensity peaks at dawn but reaches a minimum in the afternoon. The LDAPS overestimates the UHI intensity in summer but underestimates it in winter. In particular, the model tends to overestimate the UHI intensity during the daytime in summer but underestimate it during the nighttime in winter. Moreover, surface temperature errors decrease in summer but increase in winter. The underestimation of the winter UHI intensity appears to be associated with weak forecasting of urban temperature in winter. However, the overestimated summer UHI intensity results from the underestimation of the suburban temperature forecast in summer. In order to improve the predictability of the UHI intensity, an urban canopy model (MORUSES) that considers urban effects was combined with LDAPS and used for simulation for the summer of 2017. The surface temperature forecast for the city was improved significantly by adopting MORUSES, and there were remarkable improvements in urban surface temperature morning forecasts. The urban canopy model produced an improvement effect that weakened the intensity of the UHI, which showed an overestimation during summer.

Development of Nursing Costs by Nursing Activities in Clinical Nurse Specialist (전문간호사 간호행위에 관한 간호수가체계 개발)

  • Kim, Yoon-Hee;Lee, Hyang-Yeon;Han, Sang-Sook;Shin, Hye-Sook;Lee, Myung-Hee;Kim, Sook-Neoung;Lee, Hye-Jin;Kim, Hye-Sook;Choi, Hyes-Sun
    • Journal of East-West Nursing Research
    • /
    • v.13 no.2
    • /
    • pp.197-207
    • /
    • 2007
  • Purpose: This study was carried out to deveop nursing costs and to substantiate the application of appropriate activity-based nursing costs for the current clinical nurse specialists. Method: The study sample was a group of 8 home health care team of the tirtiary Hospital in Korea. The data was collected from September 2003 through December 2004. The statistical analysis was done by SPSS PC 11.0 program and calculated mean and the standard deviation. In Lee(2003)'s nursing activity analysis, nursing activities were classified into two major classification, 19 domains and 70 activities. Each activities was calculated using its work validity, physical effort, psychological effort, stress as a intensity, and the necessary time. The simple work costs was calculated the work wage per minute and the necessary time. The work load intensity was calculated using the work wage per minute and the necessary time work load intensity/100. Results: In this study, the work wage was 283 won per minute. The work validity ranged from 2.71-4.00. The highest simple work cost/work load intensity cost was 12,735won/47,374won for research activity, 10,700won/27,499won for bedsore care, and 9,727won/35,114won for deathbed care. The lowest simple work cost/work load intensity cost was 2,123won/2,038won for intramuscular injection, 2,210won/2,166won for hypodermic injection, and 2,210won/1,547won for a application of medicine(or ointment or cream). Conclusions: It revealed that the nursing cost should be considered validity, physical effort, psychological effort, stress as a intensity, and necessary time. Therefore, It is necessary to calculate nursing cost systematically based on activities.

  • PDF

An Analysis on the Factors Affecting the Level of Globalization of Korean Venture Business (한국의 벤처기업은 태생적 글로벌기업인가: 벤처기업의 국제화에 미치는 영향 요인 분석)

  • Kim, Jong Woon
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.11 no.3
    • /
    • pp.37-48
    • /
    • 2016
  • The purpose of this study is to investigate the factors that affect the degree of export intensity of Korean venture businesses, and to analyze the effect of export intensity on corporate performance. We use 1,970 firm data (from Venture Business Survey by Small & Medium Business Administration) and analyze the possible factors of the CEO characteristics, the corporate characteristics, and the environmental factors. Our analysis shows that Korean venture business' CEO characteristics, such as his/her doctoral degree and marketing work experiences, increase their export intensity statistically significantly, while their age does not. In addition, the companies who outsource their products have a higher export intensity, and, as the firm age increases, the export intensity decreases significantly. It is also analyzed that, as the number of export regions or FDI regions increases, their export intensity goes higher. However, firms' higher level of internationalization does not bring higher performance of the venture firms, while it does significantly for the venture firms that are older than 10 years. The result implies that CEO's education or work experiences and strategic approaches are important for corporate globalization, and that it takes time for globalizing venture firms to be able to garner profits from their global investments.

  • PDF

CO2 Emission Structure Analysis of Industrial Sector with Environmental Input-Output Table 2005 (환경산업연관표 2005를 이용한 산업부문의 이산화탄소(CO2) 배출 분석)

  • Kim, Yoon Kyung
    • Environmental and Resource Economics Review
    • /
    • v.20 no.1
    • /
    • pp.1-31
    • /
    • 2011
  • By employing Environmental Input-Output Table 2005, which has 76 intermediate sector and 21 energy sources, this paper analyses the flow of energy demand and $CO_2$ after estimating an induced $CO_2$ emissions from 76 industrial sectors. Index of $CO_2$ intensity($CO_2/GDP$) and other index of $CO_2$ intensity($CO_2/calory$) showed that final demand sector uses more high calory energy source. Intermediate sector used less environmental friendly energy source and emit more $CO_2$ at same calory. Industries those has high induced $CO_2$ emissions are Thermal Power($32.587CO_2-g/Won$), Cement($10.370CO_2-g/Won$), Road Transportation($7.255CO_2-g/Won$), Cokes and Other Coal Products($5.791CO_2-g/Won$), Steam and Hot water supply, Sewage, Sanitary services($4.575CO_2-g/Won$). It is shown that industry such as Iron and Steel which has low $CO_2$ intensity, high backward linkage effect and high forward linkage effect makes high induced $CO_2$ emissions. Environmental load and $CO_2$ emissions in overall economy will decrease when not high $CO_2$ intensity industry but also low $CO_2$ intensity industry makes lower $CO_2$ intensity.

  • PDF

Changes in Acoustic Parameters According to Intensity Increase in Voice Assessment (음성질환자의 음성검사 시 강도 증가에 따른 음향학적 지표의 변화)

  • Nam, Do-Hyun;Rheem, Sung-Sue;Yun, Bo-Ram;Cho, Sun-A;Choi, Hong-Shik
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.22 no.2
    • /
    • pp.143-150
    • /
    • 2011
  • Background and Objectives : Clinically, as a tool for voice assessment before and after the operation or the voice treatment, acoustic analysis is widely used. However, in clinical situations, acoustic parameters vary according to how the assessment is made. Thus, with voice disease patients as subjects, we are to investigate what influence intensity increase exerts on acoustic parameters and how to reduce variation according to the way of assessing. Material and Method : At the voice clinic of the department of otorhinolaryngology in Gangnam Severance Hospital, with 30 female voice-disease patients (40.6 years old on the average) and 23 male voice-disease patients (40.1 years old on the average) as subjects, using the Dr Speech vocal-assessment program, we statistically tested the significance of the difference in each of acoustic parameters between when the "Ah" vowel is produced with a normal voice and when the "Ah" vowel is produced with a loud voice. Results : Acoustic parameters that showed a statistically significant difference according to intensity increase were Jitter, SD F0, and NNE for females, and Jitter, SD F0, HNR, SNR, and NNE for males. Voice quality estimates showed a statistically significant difference according to intensity increase in female hoarse voice, female breathy voice, and male breathy voice. Conclusion : In this research, acoustic analysis, which is generally used for voice assessment before and after the operation or the voice treatment, showed a tendency that acoustic parameters became better under the influence of intensity increase except for the cases where a voice disease was severe. Thus, to raise the reliability of voice assessment, the range of intensity needs to be set up. This should be the topic for the future research.

  • PDF

Analysis on Correlation between AE Parameters and Stress Intensity Factor using Principal Component Regression and Artificial Neural Network (주성분 회귀분석 및 인공신경망을 이용한 AE변수와 응력확대계수와의 상관관계 해석)

  • Kim, Ki-Bok;Yoon, Dong-Jin;Jeong, Jung-Chae;Park, Phi-Iip;Lee, Seung-Seok
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.21 no.1
    • /
    • pp.80-90
    • /
    • 2001
  • The aim of this study is to develop the methodology which enables to identify the mechanical properties of element such as stress intensity factor by using the AE parameters. Considering the multivariate and nonlinear properties of AE parameters such as ringdown count, rise time, energy, event duration and peak amplitude from fatigue cracks of machine element the principal component regression(PCR) and artificial neural network(ANN) models for the estimation of stress intensity factor were developed and validated. The AE parameters were found to be very significant to estimate the stress intensity factor. Since the statistical values including correlation coefficients, standard mr of calibration, standard error of prediction and bias were stable, the PCR and ANN models for stress intensity factor were very robust. The performance of ANN model for unknown data of stress intensity factor was better than that of PCR model.

  • PDF

Fracture analysis and remaining life prediction of aluminium alloy 2014A plate panels with concentric stiffeners under fatigue loading

  • Murthy, A. Ramachandra;Mathew, Rakhi Sara;Palani, G.S.;Gopinath, Smitha;Iyer, Nagesh R.
    • Structural Engineering and Mechanics
    • /
    • v.53 no.4
    • /
    • pp.681-702
    • /
    • 2015
  • Fracture analysis and remaining life prediction has been carried out for aluminium alloy (Al 2014A) plate panels with concentric stiffener by varying sizes and positions under fatigue loading. Tension coupon tests and compact tension tests on 2014A have been carried out to evaluate mechanical properties and crack growth constants. Domain integral technique has been used to compute the Stress intensity factor (SIF) for various cases. Generalized empirical expressions for SIF have been derived for various positions of stiffener and size. From the study, it can be concluded that the remaining life for stiffened panel for particular size and position can be estimated by knowing the remaining life of corresponding unstiffened panel.

Failure Analysis in Al 7075-T651 Alloy using X-ray Diffraction Technique (X-선 회절을 이용한 A1 7075-T651합금의 파손해소)

  • 오세욱;박수영;부명환
    • Journal of Ocean Engineering and Technology
    • /
    • v.7 no.2
    • /
    • pp.103-113
    • /
    • 1993
  • X-ray diffraction analysis technique was used for the fatigue damage analysis and fatigue life prediction in Al 7075-T651 alloy. The tensile test, fatigue strength and fatigue crack propagation test with change of stress ratio were carried out. As a result, half-value breadth was increased with the plastic deformation in the specimen increasint at all test conditions. In particular, half-value breadth at the surface of the specimens fractured by fatigue was increased as stress intensity factor range and effective stress intensity factor range were increased. In addition, the good relationship between half-value breadty and diffraction pattern was shown.

  • PDF