• Title/Summary/Keyword: Integrity Check

Search Result 154, Processing Time 0.027 seconds

Construction and Functional Tests of Fuel Assembly Mechanical Characterization Test Facility (핵연료집합체 기계적특성 시험시설 구축과 기능시험)

  • Lee, Kang-Hee;Kang, Heung-Seok;Yoon, Kyung-Ho;Yang, Jae-Ho
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.12 no.1
    • /
    • pp.11-16
    • /
    • 2016
  • Fuel assembly's mechanical characterization test facility (FAMeCT) in KAERI was constructed with upgraded functional features such as increased loading capacity, underwater vibration testing and severe earthquake simulation for extended fuel design guideline. This facility is designed and developed to provide out-pile fuel data for accident analysis model and fuel licensing. Functional tests of FAMeCT were performed to confirm functionality, structural integrity, and validity of newly-built fuel assembly mechanical test facility. Test program includes signal check of data acquisition system, load delivering capacity using real-sized fuel assemblies and a standard loading cylindrical rigid specimen. Fuel assembly's lateral bending test was carried out up to 30 mm of pull-out displacement. Limit case axial compression loading test up to 33 kN was performed to check structural integrity of UCPS (Upper Core Plate Simulator) support frame. Test results show that all test equipment and measurement system have acceptable range of alignment, signal to noise ratio, load carrying capacity limit without loss of integrity. This paper introduces newly constructed fuel assembly's mechanical test facility and summarizes results of functional test for the mechanical test equipment and data acquisition system.

Meteorological Data Integrity for Environmental Impact Assessment in Yongdam Catchment (용담댐시험유역 환경영향평가의 신뢰수준 향상을 위한 기상자료의 품질검정)

  • Lee, Khil-Ha
    • Journal of Environmental Science International
    • /
    • v.29 no.10
    • /
    • pp.981-988
    • /
    • 2020
  • This study presents meteorological data integrity to improve environmental quality assessment in Yongdam catchment. The study examines both extreme ranges of meteorological data measurements and data reliability which include maximum and minimum temperature, relative humidity, dew point temperature, radiation, heat flux. There were some outliers and missing data from the measurements. In addition, the latent heat flux and sensible heat flux data were not reasonable and evapotranspiration data did not match at some points. The accuracy and consistency of data stored in a database for the study were secured from the data integrity. Users need to take caution when using meteorological data from the Yongdam catchment in the preparation of water resources planning, environmental impact assessment, and natural hazards analysis.

A Light-weight, Adaptive, Reliable Processing Integrity Audit for e-Science Grid (e-Science 그리드를 위한 가볍고, 적응성있고, 신뢰성있는 처리 무결성 감사)

  • Jung, Im-Young;Jung, Eun-Jin
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.18 no.5
    • /
    • pp.181-188
    • /
    • 2008
  • E-Science Grid is designed to cope with computation-intensive tasks and to manage a huge volume of science data efficiently. However, certain tasks may involve more than one grid can offer in computation capability or incur a long wait time on other tasks. Resource sharing among Grids can solve this problem with proper processing-integrity check via audit. Due to their computing-intensive nature, the processing time of e-Science tasks tends to be long. This potential long wait before an audit failure encourages earlier audit mechanism during execution in order both to prevent resource waste and to detect any problem fast. In this paper, we propose a Light-weight, Adaptive and Reliable Audit, LARA, of processing Integrity for e-Science applications. With the LARA scheme. researchers can verify their processing earlier and fast.

Design for Strengthening Structural Integrity of the Reflective Metal Insulation in the Nuclear Power Plant (원전 금속단열재의 구조 건전성 강화를 위한 설계 방안)

  • Lee, Sung Myung;Eo, Min Hun;Kim, Seung Hyun;Jang, Kye Hwan
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.3
    • /
    • pp.107-113
    • /
    • 2015
  • The goal of this paper is to investigate structural integrity factors of RMI(reflective metal insulation) to confirm the design requirements in nuclear power plant. Currently, a glass wool insulation is using now, but it will gradually be replaced with the reflective metal insulation maded by stainless steel plates. The main function of an insulation is to minimize a heat loss of vessel and pipes in RCS(reactor coolant system). It has to maintain structural a integrity in nuclear power plant life duration. In this study, the structural integrity analysis was carried out both multi-plate and outer shell plate by using a static analysis and experimental test. First, inner multi-plate has a self support structure for being air space. Because the effect of total static weight in multi-layer plate is low, a plate collapse possibility is not high. Considering optimum thin plate pressing process, it has to pre-check the basic physical properties. Second, the outer segment thickness and stiffener shape are verified by the numerical static analysis, and sample test for both type of panel and cylindrical pipe model.

Quantitative Risk Reduction Model according to SIL allocated by Risk Graph for Railway Platform Door System (Risk Graph에 의해 할당된 SIL에 따른 철도 승강장 도어 시스템의 정량적 Risk 저감 모델)

  • Song, Ki Tae;Lee, Sung Ill
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.5
    • /
    • pp.141-148
    • /
    • 2016
  • There exists required safety integrity level (SIL) to assure safety in accordance with international standards for every electrical / electronics / control equipment or systems with safety related functions. The SIL is allocated from lowest level (level 0) to highest level (level 4). In order to guarantee certain safety level that is internationally acceptable, application of methodology for SIL allocation and demonstration based on related international standards is required. Especially, in case of the SIL allocation method without determining of quantitative tolerable risk, the additional review is needed to check whether it is suitable or not is required. In this study, the quantitative risk reduction model based on the safety integrity allocation results of railway platform screen door system using Risk Graph method has been examined in order to review the suitability of quantitative risk reduction according to allocated safety integrity level.

A Study on the Structural Integrity of an Auxiliary Feed Water Pump in a Nuclear Power Plant (원자력 발전소 보조급수펌프의 구조 건전성에 관한 연구)

  • Kim, Chae-Sil;Cho, Bang-Hyun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.13 no.3
    • /
    • pp.42-48
    • /
    • 2014
  • The auxiliary-feed-water pump (AFWP) used to supply water during a station black out situation at nuclear power plants should meet the seismic qualification regulations stipulated in IEEE Std 323 and 344, so as to withstand earthquakes or dangerous situations. Here, we establish a model for the estimation of the structural integrity of this type of pump. If the natural frequency that results from a modal analysis is less than 33 Hz, we adopt a dynamic analysis, instead of a static analysis. A dynamic analysis was carried out taking into consideration seismic conditions such as the floor response spectra (FRS), an operation-base earthquake (OBE), and a safe-shutdown earthquake (SSE). Finally, an analytical estimation of the structural integrity of an AFWP is made through a comparison of calculated values and allowable values. If the result is less than the allowable stress, the pump is deemed to have good structural integrity. In addition, future studies will involve a stability check for rotor accidents that may occur during the operation of the pump.

Provably-Secure Public Auditing with Deduplication

  • Kim, Dongmin;Jeong, Ik Rae
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.11 no.4
    • /
    • pp.2219-2236
    • /
    • 2017
  • With cloud storage services, users can handle an enormous amount of data in an efficient manner. However, due to the widespread popularization of cloud storage, users have raised concerns about the integrity of outsourced data, since they no longer possess the data locally. To address these concerns, many auditing schemes have been proposed that allow users to check the integrity of their outsourced data without retrieving it in full. Yuan and Yu proposed a public auditing scheme with a deduplication property where the cloud server does not store the duplicated data between users. In this paper, we analyze the weakness of the Yuan and Yu's scheme as well as present modifications which could improve the security of the scheme. We also define two types of adversaries and prove that our proposed scheme is secure against these adversaries under formal security models.

The Evaluation of the Electronic Housing Structural Integrity Using Dynamic Analysis (동특성 분석을 통한 하우징의 구조건전성 평가)

  • Lee, Jae-Eun;Choi, Hye-yoon;Kim, Byung-Jun;Lee, Jeung;Jeong, Oh-Kyun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.54-59
    • /
    • 2014
  • The rapid tactical operation and mobility are getting important to recently developed the guided weapon systems. And military wants multi-purposes equipment to carry the war more easily. So military wants to have the equipment that can apply without any distinction about environment. For this reason, the robust design is getting more important now to guarantee survivability of equipment. In this paper, we try to check about structural integrity of Fire Control Unit(FCU) which is one of the guided weapon system using dynamic FEM analysis.

  • PDF

The People Navigator : A New Collaboration Chatting Application (The People Navigator: 새로운 협동 Chatting 애플리케이션)

  • 유상진;장영택;윤성로
    • Korean Management Science Review
    • /
    • v.18 no.1
    • /
    • pp.79-88
    • /
    • 2001
  • We often feel the necessity to communicate with members involved in a project to remote discuss business activities, needs for the fast file transfer, and check the existence of members to talk with. There are some commercial applications in these problems. However, in addition to those existing functions, this study focuses especially on adding couple of functions such as automatic responding function, in which a sender of a message automatically knows if a receiver checks the message. Its application is that a project leader sends an important message and later on can check at his desk the fact that who have checked their messages. The prototype application, build in this study, will check the correctness of every sub-function, and then the interface of inter-sub-functions, finally the integrity of the entire system, so that important information will not be lost among members of a project in the real world situation.

  • PDF

Investigation on Effects of Residual Stresses and Charpy V-Notch Impact Energy on Brittle Fractures of the Butt Weld between Close Check Valve and Piping, and of the Valve Body in Nuclear Power Plants (원전 역지 밸브/배관 맞대기 용접부와 밸브 몸체의 취성 파괴에 미치는 잔류응력 및 Charpy V-노치 충격에너지의 영향 고찰)

  • Kim, Jong-Sung;Kim, Hyun-Su
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.11 no.1
    • /
    • pp.69-73
    • /
    • 2015
  • The study investigated effects of residual stresses and Charpy impact energy on brittle fractures of the butt weld between the valve and the piping, and of the valve body in nuclear power plants via a linear elastic fracture mechanics approach in the ASME B&PV Code, Sec.XI and finite element analysis. Weld residual stress in a butt weld between close check valve and piping, and residual stress in the valve due to casting process were assumed to be proportional to yield strength of base metal. Operating stresses in the butt weld and the valve body were calculated using approximate engineering formulae and finite element analysis, respectively. Applied stress intensity factors were calculated by assuming postulated cracks with specific sizes and then by substituting the residual stresses and the operating stresses into engineering formulae presented in the ASME B&PV Code, Sec.III. Plane strain fracture toughness was derived by using a correlation between Charpy V-notch impact energy and fracture toughness. Structural integrity of the weld and the body against brittle fracture was assessed by using the applied stress intensity factors, plane strain fracture toughness and the linear elastic fracture mechanics approach. As a result, it was identified that the structural integrity was maintained with decreasing the residual stress levels and increasing the Charpy V-notch impact energy.