• Title/Summary/Keyword: Integral Images

Search Result 228, Processing Time 0.022 seconds

Characteristics of integral imaging microscope using point light source array

  • Lim, Young-Tae;Park, Jae-Hyeung;Kwon, Ki-Chul;Kim, Nam
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.1354-1356
    • /
    • 2009
  • In this paper, we explained characteristics of integral imaging microscope using point light source. To display the bio-medical information, which is captured as a form of the elemental images, using autostereoscopic displays, the characteristics analysis of three-dimensional information is required. For integral imaging microscope using point light source array, the elemental image capturing configuration has to satisfy a specific condition. We explain the condition to capture the elemental images and show the experimental results.

  • PDF

Viewing Angle-Improved 3D Integral Imaging Display with Eye Tracking Sensor

  • Hong, Seokmin;Shin, Donghak;Lee, Joon-Jae;Lee, Byung-Gook
    • Journal of information and communication convergence engineering
    • /
    • v.12 no.4
    • /
    • pp.208-214
    • /
    • 2014
  • In this paper, in order to solve the problems of a narrow viewing angle and the flip effect in a three-dimensional (3D) integral imaging display, we propose an improved system by using an eye tracking method based on the Kinect sensor. In the proposed method, we introduce two types of calibration processes. First process is to perform the calibration between two cameras within Kinect sensor to collect specific 3D information. Second process is to use a space calibration for the coordinate conversion between the Kinect sensor and the coordinate system of the display panel. Our calibration processes can provide the improved performance of estimation for 3D position of the observer's eyes and generate elemental images in real-time speed based on the estimated position. To show the usefulness of the proposed method, we implement an integral imaging display system using the eye tracking process based on our calibration processes and carry out the preliminary experiments by measuring the viewing angle and flipping effect for the reconstructed 3D images. The experimental results reveal that the proposed method extended the viewing angles and removed the flipping images compared with the conventional system.

Implementation of an Emulator for the Integrated Image Reconstruction according to Distance (거리에 따른 집적 영상 복원을 지원하는 에뮬레이터의 구현)

  • Jang, Ha Eun;Lee, Eun Ji;Lee, Yeon Ju;Lim, Soon-Bum
    • Journal of Korea Multimedia Society
    • /
    • v.19 no.3
    • /
    • pp.548-556
    • /
    • 2016
  • Integral imaging is an auto-stereoscopic display method that can produce 3D image of a finite viewing window through an array of micro elemental lenses. Integral imaging requires the pickup part of each elemental images acquisition and display part of reconstruction of the images. The successful reconstructed image depends on various parameters such as distance between lens arrays and display device, focal length of lenses, and a number of the array. In this paper, we present reconstruction emulator for display of Integral imaging in order to adjust parameters for 3D contents reconstruction and to observe the result from different configuration. Especially, we provide the user interface for the emulator to control the distance easily. We have confirmed through various experiments that the emulator adjusted the distance and could check error in the process of creating elemental images.

Three-Dimensional Imaging and Display through Integral Photography

  • Navarro, Hector;Dorado, Adrian;Saavedra, Genaro;Corral, Manuel Martinez
    • Journal of information and communication convergence engineering
    • /
    • v.12 no.2
    • /
    • pp.89-96
    • /
    • 2014
  • Here, we present a review of the proposals and advances in the field of three-dimensional (3D) imaging acquisition and display made in the last century. The most popular techniques are based on the concept of stereoscopy. However, stereoscopy does not provide real 3D experience, and produces discomfort due to the conflict between convergence and accommodation. For this reason, we focus this paper on integral imaging, which is a technique that permits the codification of 3D information in an array of 2D images obtained from different perspectives. When this array of elemental images is placed in front of an array of microlenses, the perspectives are integrated producing 3D images with full parallax and free of the convergence-accommodation conflict. In the paper we describe the principles of this technique, together with some new applications of integral imaging.

3D Image Correlator using Computational Integral Imaging Reconstruction Based on Modified Convolution Property of Periodic Functions

  • Jang, Jae-Young;Shin, Donghak;Lee, Byung-Gook;Hong, Suk-Pyo;Kim, Eun-Soo
    • Journal of the Optical Society of Korea
    • /
    • v.18 no.4
    • /
    • pp.388-394
    • /
    • 2014
  • In this paper, we propose a three-dimensional (3D) image correlator by use of computational integral imaging reconstruction based on the modified convolution property of periodic functions (CPPF) for recognition of partially occluded objects. In the proposed correlator, elemental images of the reference and target objects are picked up by a lenslet array, and subsequently are transformed to a sub-image array which contains different perspectives according to the viewing direction. The modified version of the CPPF is applied to the sub-images. This enables us to produce the plane sub-image arrays without the magnification and superimposition processes used in the conventional methods. With the modified CPPF and the sub-image arrays, we reconstruct the reference and target plane sub-image arrays according to the reconstruction plane. 3D object recognition is performed through cross-correlations between the reference and the target plane sub-image arrays. To show the feasibility of the proposed method, some preliminary experiments on the target objects are carried out and the results are presented. Experimental results reveal that the use of plane sub-image arrays enables us to improve the correlation performance, compared to the conventional method using the computational integral imaging reconstruction algorithm.

Comparisons of Object Recognition Performance with 3D Photon Counting & Gray Scale Images

  • Lee, Chung-Ghiu;Moon, In-Kyu
    • Journal of the Optical Society of Korea
    • /
    • v.14 no.4
    • /
    • pp.388-394
    • /
    • 2010
  • In this paper the object recognition performance of a photon counting integral imaging system is quantitatively compared with that of a conventional gray scale imaging system. For 3D imaging of objects with a small number of photons, the elemental image set of a 3D scene is obtained using the integral imaging set up. We assume that the elemental image detection follows a Poisson distribution. Computational geometrical ray back propagation algorithm and parametric maximum likelihood estimator are applied to the photon counting elemental image set in order to reconstruct the original 3D scene. To evaluate the photon counting object recognition performance, the normalized correlation peaks between the reconstructed 3D scenes are calculated for the varied and fixed total number of photons in the reconstructed sectional image changing the total number of image channels in the integral imaging system. It is quantitatively illustrated that the recognition performance of the photon counting integral imaging system can be similar to that of a conventional gray scale imaging system as the number of image viewing channels in the photon counting integral imaging (PCII) system is increased up to the threshold point. Also, we present experiments to find the threshold point on the total number of image channels in the PCII system which can guarantee a comparable recognition performance with a gray scale imaging system. To the best of our knowledge, this is the first report on comparisons of object recognition performance with 3D photon counting & gray scale images.

Three-Dimensional Visualization and Recognition of Micro-objects using Photon Counting Integral Imaging Microscopy (광자 계수 집적 영상 현미경을 사용한 마이크로 물체의 3차원 시각화와 인식)

  • Cho, Myungjin;Cho, Giok;Shin, Donghak
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.5
    • /
    • pp.1207-1212
    • /
    • 2015
  • In this paper, we propose three-dimensional (3D) visualization and recognition techniques of micro-objects under photon-starved conditions using photon counting integral imaging microscopy. To capture high resolution 2D images with different perspectives in the proposed method, we use Synthetic Aperture Integral Imaging (SAII). Poisson distribution which is mathematical model of photon counting imaging system is used to extract photons from the images. To estimate 3D images with 2D photon counting images, the statistical estimation is used. Therefore, 3D images can be obtained and visualized without any damage under photon-starved conditions. In addition, 3D object recognition can be implemented using nonlinear correlation filters. To prove the usefulness of our technique, we implemented the optical experiment.

Three-dimensional/two-dimensional convertible integral imaging display system using an active mask (동적 마스크를 이용한 3D/2D 변환 집적영상 디스플레이 시스템)

  • Oh, Yongseok;Shin, Donghak;Lee, Byung-Gook;Jeong, Shin-Il
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.12
    • /
    • pp.3055-3062
    • /
    • 2014
  • 3D integral imaging technique with an active mask is capable of displaying real 3D images with high resolution in space. In this paper, we present a novel 3D/2D convertible integral imaging display system using an active mask. For the proposed method, the principles of 3D, 2D, and 3D/2D composed operations are explained according to the displayed images through two LCD panels. In 3D mode, the elemental images and the mask images are displayed in two display panels. On the other hand, the light source image and 2D image are displayed in 2D mode. In addition, 3D/2D mode is obtained using the spatial separation for 3D and 2D modes. To show the feasibility of the proposed method, we carry out the preliminary experiments and present the optical results.

3D Visualization Technique for Occluded Objects in Integral Imaging Using Modified Smart Pixel Mapping

  • Lee, Min-Chul;Han, Jaeseung;Cho, Myungjin
    • Journal of information and communication convergence engineering
    • /
    • v.15 no.4
    • /
    • pp.256-261
    • /
    • 2017
  • In this paper, we propose a modified smart pixel mapping (SPM) to visualize occluded three-dimensional (3D) objects in real image fields. In integral imaging, orthoscopic real 3D images cannot be displayed because of lenslets and the converging light field from elemental images. Thus, pseudoscopic-to-orthoscopic conversion which rotates each elemental image by 180 degree, has been proposed so that the orthoscopic virtual 3D image can be displayed. However, the orthoscopic real 3D image cannot be displayed. Hence, a conventional SPM that recaptures elemental images for the orthoscopic real 3D image using virtual pinhole array has been reported. However, it has a critical limitation in that the number of pixels for each elemental image is equal to the number of elemental images. Therefore, in this paper, we propose a modified SPM that can solve this critical limitation in a conventional SPM and can also visualize the occluded objects efficiently.

Generation scheme of elemental images for full-direction-curved integral imaging (전방향 커브형 집적 영상에서의 요소 영상의 제작 방법)

  • Shin Dong-Hak;Cho Byung-Chul;Kim Eun-Soo
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.5
    • /
    • pp.905-909
    • /
    • 2006
  • Recently various types of curved integral imaging system have been reported for improvement of viewing angle. However, the optical implementation has been limited to only unidirectional system. In this paper, we propose a curved integral imaging (CII) system with additional use of a large-aperture ten in conventional II system and explain a generation scheme of elemental images in the proposed system. The proposed system provides full-directional curvature effect and has simple structure due to the use of well-fabricated flat devices. For the full-directional-curved II system, we perform my analysis based on Johns matrix and synthesize novel elemental images. To show the usefulness of synthesized elemental images, preliminary experiments were performed and some experimental results were presented.