Optimum Design of the Intake Tower of Rerervoir -With Application of Strength Design Method- (저수지 취수탑의 최적설계에 관한 연구(II) -강도설계법을 중심으로-)

  • 김종옥;고재군
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.30 no.3
    • /
    • pp.82-94
    • /
    • 1988
  • A growing attention has been paid to the optimum design of structures in recent years. Most studies on the optimum design of reinforced concrete structures has been mainly focussed to the design of structural members such as beams, slabs and columns, and there exist few studies that deal with the optimum design of large-scale concrete shell structures. The purpose of the present investigation is, therefore, to set up an efficient optimum design method for the large-scale reinforced concrete cylindrical shell structures like intake tower of reservoir. The major design variables are the dimensions and steel areas of each member of structures. The construction cost which is compo8ed of the concrete, steel, and form work costs, respectively, is taken as the objective function. The constraint equations for the design of intake-tower are derived on the basis of strength design method. The results obtained are summarized as follows 1. The efficient optimlzation algorithrns which can execute the automatic optimum design of reinforced concrete intake tower based on the strength design method were developed. 2. Since the objective function and design variables were converged to their optimum values within the first or second iteration, the optimization algorithms developed in this study seem to be efficient and stable. 3. When using the strength design method, the construction cost could be saved about 9% compared with working stress design method. Therefore, the reliability of algorithm was proved. 4. The difference in construction cost between the optimum designs with substructures and with entire structure was found to be small and thus the optimum design with substructures may conveniently be used in practical design. 5. The major active constraints of each structural member were found to be the 'bending moment constraint for slab, the minimum longitudinal steel ratio constraint for tower body and the shearing force, bending moment and maximum eccentricity constraints for footing, respectively. 6. The computer program developed in the present study can be effectively used even by an uneiperienced designer for the optimum design of reinforced concrete intake-tower on the basis of strength design method.

  • PDF

Interannual and Seasonal Fluctuations of Nutrients, Suspended Solids, Chlorophyll, and Trophic Sate along with Other General Water Quality Parameters Near Two Intake Towers of Daechung Dam

  • Lee, Sun-Goo;Han, Jeong-Ho;Lee, Jae-Hoon;An, Kwang-Guk
    • Korean Journal of Ecology and Environment
    • /
    • v.43 no.4
    • /
    • pp.492-502
    • /
    • 2010
  • The study objects were to analyze long-term and seasonal variations of nutrients (N, P), suspended solids, N:P ratios, algal chlorophyll, and trophic state along with general water quality parameters in four sampling sites including two intake tower sites supplying drinking water in Daechung Reservoir. For the analysis, we used water quality long-term data sampled during 1998~2007 by the Ministry of Environment, Korea. Interannual and seasonal trends in inflow and discharge near the intake tower facilities over the ten years were directly influenced by rainfall pattern. The distinct difference between wet year (2003) and dry year (2001) produced marked differences in water temperature, pH, dissolved oxygen, organic matter contents, nutrients, and these variables influenced algal biomass and trophic state. Values of TP varied depending on the year and locations sampled, but monthly mean TP always peaked during July~August when river inflow and precipitation were maxima. In contrast, TN varied little compared to TP, indicating lower influence by seasonal flow compared to phosphorus. The number of E. coli were highest in Site 2 (Chudong intake tower) and varied largely, whereas at other sites, the numbers were low and low variations. Contents of chlorophyll-${\alpha}$ (CHL), as an estimation of primary productivity, varied largely depending on the year and season. The maximum of CHL occurred at Muneu intake tower (S4) during 2006 when the precipitation and inflow were lowest. In contrast, another CHL peak was observed in Site 2 (Chudong intake tower) in 2006 when one of the largest typoons (Ewinia) occurred and river runoff were maximum. So the CHL maxima were associated with both wet year (high flow, high nutrient supply) and dry year (low flow, nutrient supply by littoral zone). Such conditions influenced trophic states, based on Trophic State Index of nutrients and CHL. Based on all analyses, we can provide some clues for management and protection strategies of two intake tower sites.

Korean Female Adolescents' Food Attitudes and Food Intake Relative to the Korean Food Tower (I) : Food Intake

  • Kim, Kyeung-Eun;Resalie J. Amos
    • Journal of Community Nutrition
    • /
    • v.4 no.3
    • /
    • pp.164-179
    • /
    • 2002
  • A survey was conducted to examine the food intake of 285 Korean female students attending a secondary school in Seoul. Food intake was assessed using a food frequency based on the Korean Food Tower which consists of five food groups, i.e., grain products, vegetables and fruits, meat, milk, and fats and sweets. To describe food intake descriptive statistics were obtained using SPSS. The food frequency analysis indicated that the participants ate rice, cabbage kimchi, radish, and soybean/red pepper paste most frequently along with milk, ice cream, tea, and seasonal fruits such as citrus fruits, apples, watermelon, and grapes for snacks. Distributions of the total standardized serving frequency for each food group indicated that approximately 84, 83, 45, 60, and 34%, respectively, of the respondents met the recommended serving frequency for grain products, vegetables and fruits, meat, milk, and fats and sweets groups(mean servings per day 5.5, 10.6, 5.5, 2.1, 3.5). Income was the only demographic factor that affected food intake, particularly with respect to meat, milk, and fats and sweets(p < .01). In Korea, these food groups are generally more expensive than the other ones. (J Community Nutrition 4(3) : 164∼179, 2002)

Development of a nonlinear seismic response capacity spectrum method for intake towers of dams

  • Cocco, Leonardo;Suarez, Luis E.;Matheu, Enrique E.
    • Structural Engineering and Mechanics
    • /
    • v.36 no.3
    • /
    • pp.321-341
    • /
    • 2010
  • The seismic-induced failure of a dam could have catastrophic consequences associated with the sudden release of the impounded reservoir. Depending on the severity of the seismic hazard, the characteristics and size of the dam-reservoir system, preventing such a failure scenario could be a problem of critical importance. In many cases, the release of water is controlled through a reinforced-concrete intake tower. This paper describes the application of a static nonlinear procedure known as the Capacity Spectrum Method (CSM) to evaluate the structural integrity of intake towers subject to seismic ground motion. Three variants of the CSM are considered: a multimodal pushover scheme, which uses the idea proposed by Chopra and Goel (2002); an adaptive pushover variant, in which the change in the stiffness of the structure is considered; and a combination of both approaches. The effects caused by the water surrounding the intake tower, as well as any water contained inside the hollow structure, are accounted for by added hydrodynamic masses. A typical structure is used as a case study, and the accuracy of the CSM analyses is assessed with time history analyses performed using commercial and structural analysis programs developed in Matlab.

Management of Water Quality of Embayments in Daechong Reservoir (대청호 정체수역의 수질예측과 관리)

  • Lee, Jong-Ho
    • Journal of Environmental Impact Assessment
    • /
    • v.3 no.2
    • /
    • pp.33-45
    • /
    • 1994
  • Water quality of Chongju and Daejeon Water Intake Tower Region, embayments in Daechong Reservoir was found to be worse than that of main lake after analysis of water which were sampled during April, July, October in 1993. Concentration of COD and SS at those two water intake tower sites were 2.8-5.6 mg/l and 2.2-3.2 mg/l, higher than that of main lake. T-N concentration of those two sites was 1.1-1.9 mg/l similar to that of main lake, and T-P concentration of those two sites was 0.14-0.18 mg/l, higher than that of main lake. This study used water quality model of embayment which can analyse pollutant loads from stream and surrounding land use, advection, decay, and diffusion transport between embayment and main lake. The model can predict water quality of embayment according to the change of pollutant load, water elevation of embayment, quantity of water intake in order to suggest water quality management. This study suggests embayment water quality management alternatives, 1) construction of waste water treatment facilities at embayment and main lake for the decrease of pollutant loading, 2) water intake at main lake less polluted or eutrophicated than embayment, and 3) outflow elevation selection for polluted hypolimnion water outflow during stratification.

  • PDF

Improving the natural ventilation in multi-housing units of tower-type buildings according to their shapes and directions (탑상형 공동주택의 주동형태와 배치각에 따른 주호의 자연환기 성능)

  • Yoo, Seon-Yong;Kim, Ji-Yoeng;Kim, Tae-Yeon;Leigh, Seung-Bok
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.897-902
    • /
    • 2006
  • Natural ventilation is an effective method for improving IAQ(Indoor Air Quality) and removing heats in buildings. In oder to use natural ventilation, many factors such as wind pressure around the buildings and possibility of air intake on different shapes need to be known. On this paper, the natural ventilation performance in multi-housing units of tower-type buildings was investigated. Tower-type multi-housing buildings are recently more and more constructed for they may change urban landscape and get more openness in multi-housing site. However, such housing buildings have problems with natural ventilation because of the various directions of the building units. The purpose of this paper is to find the proper building direction regarding to wind direction in order to optimize air intake in every units in the building.

  • PDF

Ecological Characteristics of Limnoperna fortunei in an Enclosed Facility of Water Supply Pipeline (폐쇄공간 송수관로 수역내 민물담치의 생태특성)

  • Shin, Yee-Sook;Chong, Sun-A;Shin, Jae-Ki
    • Journal of Korean Society on Water Environment
    • /
    • v.29 no.3
    • /
    • pp.420-427
    • /
    • 2013
  • In this study, the ecological characteristics of Limnoperna fortunei were surveyed as a preceding research to solve the problem such as biofouling or biowaste caused by those organisms in the closed water pipeline. Limnoperna fortunei was collected not in the main reaches of Somjin River but inside and outside of the intake tower which is located in the lower part of Sueo Reservoir. The dense populations were found at the inlet mouth and near part of the pipeline. Their byssuses were formed as a thick and tightly interwind mat. The rusted parts of the pipeline hold relatively more shells than those of the normal parts. Average count of the numbers ranged $12.1{\sim}136.5ind./m^2$ through the sampling stations (A,B and C). The amount of attached shells at each station were A=386, B=258, and C=71, respectively. The relationships of shell height-length and shell length-width were proportional. The majority sizes in each station ranged A=20.01~22.00 mm (33.9%), B=10.01~14.00 mm (51.2%), and C=18.01~20.00 mm (22.5%), 24.01~26.00 mm (21.1%), respectively. Most of the bigger size of shells on C station was found dead. The ecological habitat seemed less suitable for Limnoperna fortunei when they located farther away from the intake tower of reservoir. From now on, it is necessary to consider the continuous monitoring of this organism.

A Study on the Stability of Intake gate in a Dam (취수문비의 안정성에 관한 연구)

  • Kwack, Young-Kyun;Ko, Sung-Ho;Kang, Min-Koo
    • The KSFM Journal of Fluid Machinery
    • /
    • v.11 no.1
    • /
    • pp.46-51
    • /
    • 2008
  • A stability analysis has been made for a newly designed gate of intake tower of reservoir. The analysis is composed of finding the natural frequency of the gate and the frequency induced by water flowing over and through the gate. ANSYS is employed to calculate the natural frequency of the gate and SC/Tetra is utilized for calculating flow field around the gate, which in turn gives the frequency of pressure force fluctuation on the gate. In addition to the safety analysis, the present study presents how the gate selectively intakes a muddy water layer located in the middle depth of reservoir.